1
-
-
78651468809
-
Percutaneous transarterial aortic valve implantation: What do we know?
-
J. Webb, and A. Cribier Percutaneous transarterial aortic valve implantation: what do we know? Eur Heart J 32 2011 104 107
-
(2011)
Eur Heart J
, vol.32
, pp. 104-107
-
-
Webb, J.1
Cribier, A.2
-
2
-
-
79251565276
-
Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
-
C. Tamburino, D. Capodanno, and A. Ramondo Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis Circulation 123 2011 299 308
-
(2011)
Circulation
, vol.123
, pp. 299-308
-
-
Tamburino, C.1
Capodanno, D.2
Ramondo, A.3
-
3
-
-
60849121992
-
Progress and current status of percutaneous aortic valve replacement: Results of three device generations of the CoreValve Revalving system
-
E. Grube, L. Buellesfeld, and R. Mueller Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system Circ Cardiovasc Interv 1 2008 167 175
-
(2008)
Circ Cardiovasc Interv
, vol.1
, pp. 167-175
-
-
Grube, E.1
Buellesfeld, L.2
Mueller, R.3
-
4
-
-
34547919242
-
Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis
-
DOI 10.1161/CIRCULATIONAHA.107.698258, PII 0000301720070814000014
-
J.G. Webb, S. Pasupati, and K. Humphries Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis Circulation 116 2007 755 763 (Pubitemid 47255993)
-
(2007)
Circulation
, vol.116
, Issue.7
, pp. 755-763
-
-
Webb, J.G.1
Pasupati, S.2
Humphries, K.3
Thompson, C.4
Altwegg, L.5
Moss, R.6
Sinhal, A.7
Carere, R.G.8
Munt, B.9
Ricci, D.10
Ye, J.11
Cheung, A.12
Lichtenstein, S.V.13
-
5
-
-
62949095752
-
Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve
-
N. Piazza, P. de Jaegere, C. Schultz, A.E. Becker, P.W. Serruys, and R.H. Anderson Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve Circ Cardiovasc Interv 1 2008 74 81
-
(2008)
Circ Cardiovasc Interv
, vol.1
, pp. 74-81
-
-
Piazza, N.1
De Jaegere, P.2
Schultz, C.3
Becker, A.E.4
Serruys, P.W.5
Anderson, R.H.6
-
6
-
-
77957064982
-
Cardiac CT: Necessary for precise sizing for transcatheter aortic implantation
-
C.J. Schultz, A.D. Moelker, and A. Tzikas Cardiac CT: necessary for precise sizing for transcatheter aortic implantation EuroIntervention 6 Suppl G 2010 G6 G13
-
(2010)
EuroIntervention
, vol.6
, Issue.SUPPL. G
-
-
Schultz, C.J.1
Moelker, A.D.2
Tzikas, A.3
-
7
-
-
43649086862
-
Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography. Implications for Transcatheter Aortic Valve Replacement
-
DOI 10.1016/j.jcmg.2007.12.006, PII S1936878X08000314
-
L.F. Tops, D.A. Wood, and V. Delgado Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement J Am Coll Cardiol Img 1 2008 321 330 (Pubitemid 351681425)
-
(2008)
JACC: Cardiovascular Imaging
, vol.1
, Issue.3
, pp. 321-330
-
-
Tops, L.F.1
Wood, D.A.2
Delgado, V.3
Schuijf, J.D.4
Mayo, J.R.5
Pasupati, S.6
Lamers, F.P.L.7
Van Der Wall, E.E.8
Schalij, M.J.9
Webb, J.G.10
Bax, J.J.11
-
8
-
-
65249147294
-
Role of multislice computed tomography in transcatheter aortic valve replacement
-
D.A. Wood, L.F. Tops, and J.R. Mayo Role of multislice computed tomography in transcatheter aortic valve replacement Am J Cardiol 103 2009 1295 1301
-
(2009)
Am J Cardiol
, vol.103
, pp. 1295-1301
-
-
Wood, D.A.1
Tops, L.F.2
Mayo, J.R.3
-
9
-
-
73649096192
-
Multimodal assessment of the aortic annulus diameter: Implications for transcatheter aortic valve implantation
-
D. Messika-Zeitoun, J.M. Serfaty, and E. Brochet Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation J Am Coll Cardiol 55 2010 186 194
-
(2010)
J Am Coll Cardiol
, vol.55
, pp. 186-194
-
-
Messika-Zeitoun, D.1
Serfaty, J.M.2
Brochet, E.3
-
10
-
-
79955470195
-
Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation
-
68675
-
A. Tzikas, C.J. Schultz, and N. Piazza Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation Catheter Cardiovasc Interv 77 2011 68675
-
(2011)
Catheter Cardiovasc Interv
, vol.77
-
-
Tzikas, A.1
Schultz, C.J.2
Piazza, N.3
-
11
-
-
77950501005
-
Three dimensional evaluation of the aortic annulus using multislice computer tomography: Are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?
-
C.J. Schultz, A. Moelker, and N. Piazza Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 31 2010 849 856
-
(2010)
Eur Heart J
, vol.31
, pp. 849-856
-
-
Schultz, C.J.1
Moelker, A.2
Piazza, N.3
-
12
-
-
78449265988
-
Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation
-
R. Gurvitch, D.A. Wood, and J. Leipsic Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation J Am Coll Cardiol Intv 3 2010 1157 1165
-
(2010)
J Am Coll Cardiol Intv
, vol.3
, pp. 1157-1165
-
-
Gurvitch, R.1
Wood, D.A.2
Leipsic, J.3
-
13
-
-
79952200980
-
The use of MSCT for the evaluation of the aortic root before transcutaneous aortic valve implantation: The Rotterdam approach
-
C. Schultz, A. Moelker, and A. Tzikas The use of MSCT for the evaluation of the aortic root before transcutaneous aortic valve implantation: the Rotterdam approach Euro Intervention 6 2010 505 511
-
(2010)
Euro Intervention
, vol.6
, pp. 505-511
-
-
Schultz, C.1
Moelker, A.2
Tzikas, A.3
-
14
-
-
78650517239
-
Transcatheter aortic valve implantation in aortic stenosis: The role of echocardiography
-
C. Jayasuriya, R.R. Moss, and B. Munt Transcatheter aortic valve implantation in aortic stenosis: the role of echocardiography J Am Soc Echocardiogr 24 2011 15 27
-
(2011)
J Am Soc Echocardiogr
, vol.24
, pp. 15-27
-
-
Jayasuriya, C.1
Moss, R.R.2
Munt, B.3
-
15
-
-
41249087660
-
Role of Echocardiography in Percutaneous Aortic Valve Implantation
-
DOI 10.1016/j.jcmg.2007.09.004, PII S1936878X07000149
-
R.R. Moss, E. Ivens, and S. Pasupati Role of echocardiography in percutaneous aortic valve implantation J Am Coll Cardiol Img 1 2008 15 24 (Pubitemid 351445392)
-
(2008)
JACC: Cardiovascular Imaging
, vol.1
, Issue.1
, pp. 15-24
-
-
Moss, R.R.1
Ivens, E.2
Pasupati, S.3
Humphries, K.4
Thompson, C.R.5
Munt, B.6
Sinhal, A.7
Webb, J.G.8
-
16
-
-
33644860328
-
Percutaneous aortic valve implantation retrograde from the femoral artery
-
J.G. Webb, M. Chandavimol, and C.R. Thompson Percutaneous aortic valve implantation retrograde from the femoral artery Circulation 113 2006 842 850
-
(2006)
Circulation
, vol.113
, pp. 842-850
-
-
Webb, J.G.1
Chandavimol, M.2
Thompson, C.R.3
-
17
-
-
65149100302
-
A new transcatheter aortic valve and percutaneous valve delivery system
-
J.G. Webb, L. Altwegg, J.B. Masson, S. Al Bugami, A. Al Ali, and R.A. Boone A new transcatheter aortic valve and percutaneous valve delivery system J Am Coll Cardiol 53 2009 1855 1858
-
(2009)
J Am Coll Cardiol
, vol.53
, pp. 1855-1858
-
-
Webb, J.G.1
Altwegg, L.2
Masson, J.B.3
Al Bugami, S.4
Al Ali, A.5
Boone, R.A.6
-
18
-
-
57749202934
-
Transapical aortic valve implantation: Step by step
-
T. Walther, T. Dewey, and M.A. Borger Transapical aortic valve implantation: step by step Ann Thorac Surg 87 2009 276 283
-
(2009)
Ann Thorac Surg
, vol.87
, pp. 276-283
-
-
Walther, T.1
Dewey, T.2
Borger, M.A.3
-
19
-
-
58149204388
-
Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
-
quiz 1012
-
H. Baumgartner, J. Hung, and J. Bermejo Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice J Am Soc Echocardiogr 22 2009 1 23 quiz 1012
-
(2009)
J Am Soc Echocardiogr
, vol.22
, pp. 1-23
-
-
Baumgartner, H.1
Hung, J.2
Bermejo, J.3
-
20
-
-
0029145660
-
Reproducibility of plasma hormone levels in postmenopausal women over a 23-year period
-
S.E. Hankinson, J.E. Manson, D. Spiegelman, W.C. Willett, C. Longcope, and F.E. Speizer Reproducibility of plasma hormone levels in postmenopausal women over a 23-year period Cancer Epidemiol Biomarkers Prev 4 1995 649 654
-
(1995)
Cancer Epidemiol Biomarkers Prev
, vol.4
, pp. 649-654
-
-
Hankinson, S.E.1
Manson, J.E.2
Spiegelman, D.3
Willett, W.C.4
Longcope, C.5
Speizer, F.E.6
-
21
-
-
54049102823
-
Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size?
-
V.C. Babaliaros, D. Liff, and E.P. Chen Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size? J Am Coll Cardiol Intv 1 2008 580 586
-
(2008)
J Am Coll Cardiol Intv
, vol.1
, pp. 580-586
-
-
Babaliaros, V.C.1
Liff, D.2
Chen, E.P.3
-
22
-
-
62449238365
-
Accuracy and reproducibility of left ventricular outflow tract diameter measurement using transthoracic when compared with transesophageal echocardiography in systole and diastole
-
A. Shiran, S. Adawi, M. Ganaeem, and E. Asmer Accuracy and reproducibility of left ventricular outflow tract diameter measurement using transthoracic when compared with transesophageal echocardiography in systole and diastole Eur J Echocardiogr 10 2009 319 324
-
(2009)
Eur J Echocardiogr
, vol.10
, pp. 319-324
-
-
Shiran, A.1
Adawi, S.2
Ganaeem, M.3
Asmer, E.4
|