메뉴 건너뛰기




Volumn 4, Issue 8, 2011, Pages 851-858

Transfemoral aortic valve implantation: New criteria to predict vascular complications

Author keywords

aortic stenosis; balloon valvuloplasty; risk factors; transcatheter aortic valve implantation; vascular complications

Indexed keywords

AGED; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; ARTERY CALCIFICATION; FEMALE; FEMORAL ARTERY; HUMAN; INCIDENCE; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE COMPLICATION; PREDICTOR VARIABLE; PRIORITY JOURNAL; REVIEW; SCORING SYSTEM; SURGICAL APPROACH; SURGICAL MORTALITY; SURGICAL TECHNIQUE;

EID: 84860389030     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2011.03.019     Document Type: Article
Times cited : (471)

References (20)
  • 1
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, and M. Mack Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3
  • 2
    • 78651520483 scopus 로고    scopus 로고
    • One year follow-up of the multi-centre European PARTNER transcatheter heart valve study
    • T. Lefvre, A.P. Kappetein, and E. Wolner One year follow-up of the multi-centre European PARTNER transcatheter heart valve study Eur Heart J 32 2010 148 157
    • (2010) Eur Heart J , vol.32 , pp. 148-157
    • Lefvre, T.1    Kappetein, A.P.2    Wolner, E.3
  • 3
    • 77649212932 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: Acute and late outcomes of the multicenter Canadian experience
    • J. Rodés-Cabau, J.G. Webb, and A. Cheung Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience J Am Coll Cardiol 55 2010 1080 1090
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1080-1090
    • Rodés-Cabau, J.1    Webb, J.G.2    Cheung, A.3
  • 4
    • 33644860328 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation retrograde from the femoral artery
    • J.G. Webb, M. Chandavimol, and C.R. Thompson Percutaneous aortic valve implantation retrograde from the femoral artery Circulation 113 2006 842 850
    • (2006) Circulation , vol.113 , pp. 842-850
    • Webb, J.G.1    Chandavimol, M.2    Thompson, C.R.3
  • 5
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • N. Piazza, E. Grube, and U. Gerckens Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval EuroIntervention 4 2008 242 249
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3
  • 6
    • 77956622290 scopus 로고    scopus 로고
    • Thirty-day outcome and vascular complications after transarterial aortic valve implantation using both Edwards Sapien and Medtronic CoreValve bioprostheses in a mixed population
    • D. Tchetche, N. Dumonteil, and A. Sauguet Thirty-day outcome and vascular complications after transarterial aortic valve implantation using both Edwards Sapien and Medtronic CoreValve bioprostheses in a mixed population EuroIntervention 5 2010 659 665
    • (2010) EuroIntervention , vol.5 , pp. 659-665
    • Tchetche, D.1    Dumonteil, N.2    Sauguet, A.3
  • 7
    • 77956623683 scopus 로고    scopus 로고
    • Vascular complications with transcatheter aortic valve implantation using the 18 Fr Medtronic CoreValve System: The Rotterdam experience
    • N.M. Van Mieghem, R.J. Nuis, and N. Piazza Vascular complications with transcatheter aortic valve implantation using the 18 Fr Medtronic CoreValve System: the Rotterdam experience EuroIntervention 5 2010 673 679
    • (2010) EuroIntervention , vol.5 , pp. 673-679
    • Van Mieghem, N.M.1    Nuis, R.J.2    Piazza, N.3
  • 8
    • 77954141480 scopus 로고    scopus 로고
    • Vascular complications of transfemoral aortic valve implantation with the Edwards SAPIEN prosthesis: Incidence and impact on outcome
    • G. Ducrocq, F. Francis, and J.M. Serfaty Vascular complications of transfemoral aortic valve implantation with the Edwards SAPIEN prosthesis: incidence and impact on outcome EuroIntervention 5 2010 666 672
    • (2010) EuroIntervention , vol.5 , pp. 666-672
    • Ducrocq, G.1    Francis, F.2    Serfaty, J.M.3
  • 9
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, and E. Nikolsky Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium J Am Coll Cardiol 57 2011 253 269
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 10
    • 33644910414 scopus 로고    scopus 로고
    • Treatment of calcific aortic stenosis with the percutaneous heart valve: Mid-term follow-up from the initial feasibility studies: The French experience
    • A. Cribier, H. Eltchaninoff, and C. Tron Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience J Am Coll Cardiol 47 2006 1214 1223
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1214-1223
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3
  • 13
    • 74949120850 scopus 로고    scopus 로고
    • Percutaneous endovascular aortic aneurysm repair: A prospective evaluation of safety, efficiency, and risk factors
    • M. Eisenack, T. Umscheid, J. Tessarek, G.F. Torsello, and G.B. Torsello Percutaneous endovascular aortic aneurysm repair: a prospective evaluation of safety, efficiency, and risk factors J Endovasc Ther 16 2009 708 713
    • (2009) J Endovasc Ther , vol.16 , pp. 708-713
    • Eisenack, M.1    Umscheid, T.2    Tessarek, J.3    Torsello, G.F.4    Torsello, G.B.5
  • 15
    • 77950503224 scopus 로고    scopus 로고
    • Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis
    • H. Eltchaninoff, M. Kerkeni, and A. Zajarias Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis EuroIntervention 5 2009 438 442
    • (2009) EuroIntervention , vol.5 , pp. 438-442
    • Eltchaninoff, H.1    Kerkeni, M.2    Zajarias, A.3
  • 16
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • J.G. Webb, L. Altwegg, and R.H. Boone Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes Circulation 119 2009 3009 3016
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3
  • 17
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-day results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • M. Thomas, G. Schymik, and T. Walther Thirty-day results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve Circulation 122 2010 62 69
    • (2010) Circulation , vol.122 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 18
    • 72049095572 scopus 로고    scopus 로고
    • Survival after transapical and transfemoral aortic valve implantation: Talking about two different patient populations
    • S. Bleiziffer, H. Ruge, and D. Mazzitelli Survival after transapical and transfemoral aortic valve implantation: talking about two different patient populations J Thorac Cardiovasc Surg 138 2009 1073 1080
    • (2009) J Thorac Cardiovasc Surg , vol.138 , pp. 1073-1080
    • Bleiziffer, S.1    Ruge, H.2    Mazzitelli, D.3
  • 19
    • 0038108853 scopus 로고    scopus 로고
    • Endovascular suture versus cutdown for endovascular aneurysm repair: A prospective randomized pilot study
    • DOI 10.1016/S0741-5214(02)75454-2
    • G.B. Torsello, B. Kasprzak, E. Klenk, J. Tessarek, N. Osada, and G.F. Torsello Endovascular suture versus cut-down for endovascular aneurysm repair: a prospective randomized pilot study J Vasc Surg 38 2003 78 82 (Pubitemid 41123291)
    • (2003) Journal of Vascular Surgery , vol.38 , Issue.1 , pp. 78-82
    • Torsello, G.B.1    Kasprzak, B.2    Klenk, E.3    Tessarek, J.4    Osada, N.5    Torsello, G.F.6
  • 20
    • 0036200791 scopus 로고    scopus 로고
    • Percutaneous repair of abdominal aortic aneurysms using the ANeuRx stent graft and the Percutaneous Vascular Surgery Device
    • DOI 10.1002/ccd.10072
    • M. Howell, K. Doughtery, N. Strickman, and Z. Krajcer Percutaneous repair of abdominal aortic aneurysms using the AneuRx stent graft and the percutaneous vascular surgery device Catheter Cardiovasc Interv 55 2002 281 287 (Pubitemid 34204864)
    • (2002) Catheterization and Cardiovascular Interventions , vol.55 , Issue.3 , pp. 281-287
    • Howell, M.1    Doughtery, K.2    Strickman, N.3    Krajcer, Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.