-
1
-
-
84890682333
-
American Cancer, Society., Cancer Facts and Figures, 2006., Atlanta, American Cancer Society
-
American Cancer Society. Cancer Facts and Figures 2006. Atlanta: American Cancer Society; 2006.
-
(2006)
-
-
-
3
-
-
0001227793
-
Biosensors, recent advances
-
Collings AF and Caruso F. Biosensors: recent advances. Rep Prog Phys 1997;60: 1397-1445.
-
(1997)
Rep Prog Phys
, vol.60
, pp. 1397-1445
-
-
Collings, A.F.1
Caruso, F.2
-
4
-
-
10244223555
-
Electrode systems for continuous monitoring in cardiovascular surgery
-
Clark LC Jr and Lyons C. Electrode systems for continuous monitoring in cardiovascular surgery. Ann N Y Acad Sci 1962;102:29-45.
-
(1962)
Ann N Y Acad Sci
, vol.102
, pp. 29-45
-
-
Clark Jr., L.C.1
Lyons, C.2
-
6
-
-
11144239782
-
Nanotechnology and biosensors
-
Jianrong C, Yuqing M, Nongyue H, Xiaohua W, Sijiao L. Nanotechnology and biosensors. Biotechnol Adv 2004;22:505-518.
-
(2004)
Biotechnol Adv
, vol.22
, pp. 505-518
-
-
Jianrong, C.1
Yuqing, M.2
Nongyue, H.3
Xiaohua, W.4
Sijiao, L.5
-
7
-
-
0034802766
-
Soft lithography in biology and biochemistry
-
Whitesides GM, Ostuni E, Takayama S, Jiang XY, Ingber DE. Soft lithography in biology and biochemistry. Annu Rev Biomed Eng 2001;3:335-373.
-
(2001)
Annu Rev Biomed Eng
, vol.3
, pp. 335-373
-
-
Whitesides, G.M.1
Ostuni, E.2
Takayama, S.3
Jiang, X.Y.4
Ingber, D.E.5
-
9
-
-
12244252080
-
Optical fiber-based biosensors
-
Monk DJ and Walt DR. Optical fiber-based biosensors. Anal Bioanal Chem 2004;379:931-945.
-
(2004)
Anal Bioanal Chem
, vol.379
, pp. 931-945
-
-
Monk, D.J.1
Walt, D.R.2
-
10
-
-
0034158429
-
Biosensors and biochips, advances in biological and medical diagnostics
-
Vo-Dinh T and Cullum B. Biosensors and biochips: advances in biological and medical diagnostics. Fresenius J Anal Chem 2000;366:540-551.
-
(2000)
Fresenius J Anal Chem
, vol.366
, pp. 540-551
-
-
Vo-Dinh, T.1
Cullum, B.2
-
11
-
-
4544315689
-
Fabrication of single or aggregated bacteria arrays using host-parasite and virus-antibody interactions
-
Suh KY, Khademhosseini A, Yoo PJ, Langer R. Fabrication of single or aggregated bacteria arrays using host-parasite and virus-antibody interactions. Biomed Microdevices 2004;6:223-229.
-
(2004)
Biomed Microdevices
, vol.6
, pp. 223-229
-
-
Suh, K.Y.1
Khademhosseini, A.2
Yoo, P.J.3
Langer, R.4
-
12
-
-
33745745300
-
Direct confinement of individual viruses within polyethylene glycol (PEG) nanowells
-
Suh KY, Khademhosseini A, Jon S, Langer R. Direct confinement of individual viruses within polyethylene glycol (PEG) nanowells. Nano Lett 2006;6:1196-1201.
-
(2006)
Nano Lett
, vol.6
, pp. 1196-1201
-
-
Suh, K.Y.1
Khademhosseini, A.2
Jon, S.3
Langer, R.4
-
13
-
-
0034603154
-
Adaptive recognition by nucleic acid aptamers
-
Hermann T and Patel DJ. Adaptive recognition by nucleic acid aptamers. Science 2000;287:820-825.
-
(2000)
Science
, vol.287
, pp. 820-825
-
-
Hermann, T.1
Patel, D.J.2
-
14
-
-
0034902713
-
Principles and applications of thermal biosensors
-
Ramanathan K and Danielsson B. Principles and applications of thermal biosensors. Biosens Bioelectron 2001;16:417-423.
-
(2001)
Biosens Bioelectron
, vol.16
, pp. 417-423
-
-
Ramanathan, K.1
Danielsson, B.2
-
16
-
-
32044456409
-
Nanotechnologies for biomolecular detection and medical diagnostics
-
Cheng MM, et al. Nanotechnologies for biomolecular detection and medical diagnostics. Curr Opin Chem Biol 2006;10:11-19.
-
(2006)
Curr Opin Chem Biol
, vol.10
, pp. 11-19
-
-
Cheng, M.M.1
-
17
-
-
14844362642
-
Cantilever-based biosensors
-
Ziegler C. Cantilever-based biosensors. Anal Bioanal Chem 2004;379:946-959.
-
(2004)
Anal Bioanal Chem
, vol.379
, pp. 946-959
-
-
Ziegler, C.1
-
18
-
-
0037419876
-
Nerve agents detection using a Cu2+/L-cysteine bilayer-coated microcantilever
-
Yang Y, Ji HF, Thundat T. Nerve agents detection using a Cu2+/L-cysteine bilayer-coated microcantilever. J Am Chem Soc 2003;125:1124-1125.
-
(2003)
J Am Chem Soc
, vol.125
, pp. 1124-1125
-
-
Yang, Y.1
Ji, H.F.2
Thundat, T.3
-
19
-
-
0034874270
-
Bioassay of prostate-specific antigen (PSA) using microcantilevers
-
Wu G, et al. Bioassay of prostate-specific antigen (PSA) using microcantilevers. Nat Biotechnol 2001;19:856-860.
-
(2001)
Nat Biotechnol
, vol.19
, pp. 856-860
-
-
Wu, G.1
-
20
-
-
26644435999
-
Microcantilever biosensors
-
Hansen KM and Thundat T. Microcantilever biosensors. Methods 2005;37:57-64.
-
(2005)
Methods
, vol.37
, pp. 57-64
-
-
Hansen, K.M.1
Thundat, T.2
-
21
-
-
30644459606
-
Cantilever sensor for nanomechanical detection of specific protein conformations
-
Mukhopadhyay R, et al. Cantilever sensor for nanomechanical detection of specific protein conformations. Nano Lett 2005;5:2385-2388.
-
(2005)
Nano Lett
, vol.5
, pp. 2385-2388
-
-
Mukhopadhyay, R.1
-
22
-
-
3843119792
-
Cantilever transducers as a platform for chemical and biological sensors
-
Lavrik NV, Separiak M, Datskos PG. Cantilever transducers as a platform for chemical and biological sensors. Rev Sci Instrum 2004;75:2229-2253.
-
(2004)
Rev Sci Instrum
, vol.75
, pp. 2229-2253
-
-
Lavrik, N.V.1
Separiak, M.2
Datskos, P.G.3
-
23
-
-
3142755508
-
Forward-viewing CMUT arrays for medical imaging
-
Demirci U, Ergun A, Oralkan O, Karaman M, Khuri-Yakub B. Forward-viewing CMUT arrays for medical imaging. IEEE Trans Ultrason Ferroelectr Freq Control 2004;51:887-895.
-
(2004)
IEEE Trans Ultrason Ferroelectr Freq Control
, vol.51
, pp. 887-895
-
-
Demirci, U.1
Ergun, A.2
Oralkan, O.3
Karaman, M.4
Khuri-Yakub, B.5
-
24
-
-
0037815127
-
A B cell-based sensor for rapid identification of pathogens
-
Rider TH, et al. A B cell-based sensor for rapid identification of pathogens. Science 2003;301:213-215.
-
(2003)
Science
, vol.301
, pp. 213-215
-
-
Rider, T.H.1
-
25
-
-
18444370256
-
A microfabricated array bioreactor for perfused 3D liver culture
-
Powers MJ, et al. A microfabricated array bioreactor for perfused 3D liver culture. Biotechnol Bioeng 2002;78:257-269.
-
(2002)
Biotechnol Bioeng
, vol.78
, pp. 257-269
-
-
Powers, M.J.1
-
26
-
-
33644772060
-
Microelectrode array recordings of cardiac action potentials as a high throughput method to evaluate pesticide toxicity
-
Natarajan A, Molnar P, Sieverdes K, Jamshidi A, Hickman JJ. Microelectrode array recordings of cardiac action potentials as a high throughput method to evaluate pesticide toxicity. Toxicol In Vitro 2006;20:375-381.
-
(2006)
Toxicol In Vitro
, vol.20
, pp. 375-381
-
-
Natarajan, A.1
Molnar, P.2
Sieverdes, K.3
Jamshidi, A.4
Hickman, J.J.5
-
27
-
-
0034869051
-
Modification of the cell based assay for brevetoxins using human cardiac voltage dependent sodium channels expressed in HEK-293 cells
-
Fairey ER, Bottein Dechraoui MY, Sheets MF, Ramsdell JS. Modification of the cell based assay for brevetoxins using human cardiac voltage dependent sodium channels expressed in HEK-293 cells. Biosens Bioelectron 2001;16: 579-586.
-
(2001)
Biosens Bioelectron
, vol.16
, pp. 579-586
-
-
Fairey, E.R.1
Bottein Dechraoui, M.Y.2
Sheets, M.F.3
Ramsdell, J.S.4
-
28
-
-
0034861828
-
Design and demonstration of an automated cell-based biosensor
-
Gray SA, et al. Design and demonstration of an automated cell-based biosensor. Biosens Bioelectron 2001;16:535-542.
-
(2001)
Biosens Bioelectron
, vol.16
, pp. 535-542
-
-
Gray, S.A.1
-
29
-
-
2542533774
-
Large area two-dimensional B cell arrays for sensing and cell-sorting applications
-
Kim H, Doh J, Irvine DJ, Cohen RE, Hammond PT. Large area two-dimensional B cell arrays for sensing and cell-sorting applications. Biomacromolecules 2004;5:822-827.
-
(2004)
Biomacromolecules
, vol.5
, pp. 822-827
-
-
Kim, H.1
Doh, J.2
Irvine, D.J.3
Cohen, R.E.4
Hammond, P.T.5
-
30
-
-
33645837217
-
Immunological synapse arrays, patterned protein surfaces that modulate immunological synapse structure formation in T cells
-
Doh J and Irvine DJ. Immunological synapse arrays: patterned protein surfaces that modulate immunological synapse structure formation in T cells. Proc Natl Acad Sci USA 2006;103:5700-5705.
-
(2006)
Proc Natl Acad Sci USA
, vol.103
, pp. 5700-5705
-
-
Doh, J.1
Irvine, D.J.2
-
32
-
-
0242291123
-
Molding of hydrogel multiphenotype cell microstructures to create microarrays
-
Koh WG, Itle LJ, Pishko MV. Molding of hydrogel multiphenotype cell microstructures to create microarrays. Anal Chem 2003;75:5783-5789.
-
(2003)
Anal Chem
, vol.75
, pp. 5783-5789
-
-
Koh, W.G.1
Itle, L.J.2
Pishko, M.V.3
-
34
-
-
28944445545
-
Cell docking inside microwells within reversibly sealed microfluidic channels for fabricating multiphenotype cell arrays
-
Khademhosseini A, et al. Cell docking inside microwells within reversibly sealed microfluidic channels for fabricating multiphenotype cell arrays. Lab Chip 2005;5:1380-1386.
-
(2005)
Lab Chip
, vol.5
, pp. 1380-1386
-
-
Khademhosseini, A.1
-
35
-
-
0036894488
-
Nine-analyte detection using an array-based biosensor
-
Taitt CR, Anderson GP, Lingerfelt BM, Feldstein MJ, Ligler FS. Nine-analyte detection using an array-based biosensor. Anal Chem 2002;74:6114-6120.
-
(2002)
Anal Chem
, vol.74
, pp. 6114-6120
-
-
Taitt, C.R.1
Anderson, G.P.2
Lingerfelt, B.M.3
Feldstein, M.J.4
Ligler, F.S.5
-
36
-
-
2342460864
-
A portable array biosensor for detecting multiple analytes in complex samples
-
Taitt CR, et al. A portable array biosensor for detecting multiple analytes in complex samples. Microb Ecol 2004;47:175-185.
-
(2004)
Microb Ecol
, vol.47
, pp. 175-185
-
-
Taitt, C.R.1
-
37
-
-
0842281371
-
Array biosensor for detection of toxins
-
Ligler FS, et al. Array biosensor for detection of toxins. Anal Bioanal Chem 2003;377:469-477.
-
(2003)
Anal Bioanal Chem
, vol.377
, pp. 469-477
-
-
Ligler, F.S.1
-
38
-
-
0141765891
-
The 'right' size in nanobiotechnology
-
Whitesides GM. The 'right' size in nanobiotechnology. Nat Biotechnol 2003; 21:1161-1165.
-
(2003)
Nat Biotechnol
, vol.21
, pp. 1161-1165
-
-
Whitesides, G.M.1
-
39
-
-
85011235155
-
PEBBLE nanosensors for in vitro analysis
-
Vo-Dinh T, editor. Boca Raton, FL, CRC Press
-
Monson E, Brasuel MA, Philbert A, Kopelman R. PEBBLE nanosensors for in vitro analysis. In: Vo-Dinh T, editor. Biomedical Photonics Handbook. Boca Raton, FL: CRC Press; 2003.
-
(2003)
Biomedical Photonics Handbook
-
-
Monson, E.1
Brasuel, M.A.2
Philbert, A.3
Kopelman, R.4
-
40
-
-
4344647114
-
Poly(decyl methacrylate)-based fluorescent PEBBLE swarm nanosensors for measuring dissolved oxygen in biosamples
-
Cao Y, Lee Koo YE, Kopelman R. Poly(decyl methacrylate)-based fluorescent PEBBLE swarm nanosensors for measuring dissolved oxygen in biosamples. Analyst 2004;129:745-750.
-
(2004)
Analyst
, vol.129
, pp. 745-750
-
-
Cao, Y.1
Lee Koo, Y.E.2
Kopelman, R.3
-
41
-
-
0042563228
-
Ratiometric optical PEBBLE nanosensors for real-time magnesium ion concentrations inside viable cells
-
Park EJ, Brasuel M, Behrend C, Philbert MA, Kopelman R. Ratiometric optical PEBBLE nanosensors for real-time magnesium ion concentrations inside viable cells. Anal Chem 2003;75:3784-3791.
-
(2003)
Anal Chem
, vol.75
, pp. 3784-3791
-
-
Park, E.J.1
Brasuel, M.2
Behrend, C.3
Philbert, M.A.4
Kopelman, R.5
-
42
-
-
0036854369
-
Fluorescent nano-PEBBLE sensors designed for intracellular glucose imaging
-
Xu H, Aylott JW, Kopelman R. Fluorescent nano-PEBBLE sensors designed for intracellular glucose imaging. Analyst 2002;127:1471-1477.
-
(2002)
Analyst
, vol.127
, pp. 1471-1477
-
-
Xu, H.1
Aylott, J.W.2
Kopelman, R.3
-
43
-
-
0036141883
-
A fluorescent PEBBLE nanosensor for intracellular free zinc
-
Sumner JP, Aylott JW, Monson E, Kopelman R. A fluorescent PEBBLE nanosensor for intracellular free zinc. Analyst 2002;127:11-16.
-
(2002)
Analyst
, vol.127
, pp. 11-16
-
-
Sumner, J.P.1
Aylott, J.W.2
Monson, E.3
Kopelman, R.4
-
44
-
-
0033231311
-
Optical nanosensors for chemical analysis inside single living cells. 1. Fabrication, characterization, and methods for intracellular delivery of PEBBLE sensors
-
Clark HA, Hoyer M, Philbert MA, Kopelman R. Optical nanosensors for chemical analysis inside single living cells. 1. Fabrication, characterization, and methods for intracellular delivery of PEBBLE sensors,Anal Chem 1999;71: 4831-4836.
-
(1999)
Anal Chem
, vol.71
, pp. 4831-4836
-
-
Clark, H.A.1
Hoyer, M.2
Philbert, M.A.3
Kopelman, R.4
-
45
-
-
0033230266
-
Optical nanosensors for chemical analysis inside single living cells 2. Sensors for pH and calcium and the intracellular application of PEBBLE sensors
-
Clark HA, Kopelman R, Tjalkens R, Philbert MA. Optical nanosensors for chemical analysis inside single living cells. 2. Sensors for pH and calcium and the intracellular application of PEBBLE sensors. Anal Chem 1999;71:4837-4843.
-
(1999)
Anal Chem
, vol.71
, pp. 4837-4843
-
-
Clark, H.A.1
Kopelman, R.2
Tjalkens, R.3
Philbert, M.A.4
-
46
-
-
4644251997
-
Optochemical nanosensor PEBBLEs, photonic explorers for bioanalysis with biologically localized embedding
-
Buck SM, et al. Optochemical nanosensor PEBBLEs: photonic explorers for bioanalysis with biologically localized embedding. Curr Opin Chem Biol 2004;8:540-546.
-
(2004)
Curr Opin Chem Biol
, vol.8
, pp. 540-546
-
-
Buck, S.M.1
-
47
-
-
0034659211
-
Fiber-optic chemical sensors and biosensors
-
Wolfbeis OS. Fiber-optic chemical sensors and biosensors. Anal Chem 2000; 72:81R-89R.
-
(2000)
Anal Chem
, vol.72
-
-
Wolfbeis, O.S.1
-
48
-
-
0035872320
-
Fluorescent nanosensors for intracellular chemical analysis, decyl methacrylate liquid polymer matrix and ion-exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells
-
Brasuel M, Kopelman R, Miller TJ, Tjalkens R, Philbert MA. Fluorescent nanosensors for intracellular chemical analysis: decyl methacrylate liquid polymer matrix and ion-exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells. Anal Chem 2001;73:2221-2228.
-
(2001)
Anal Chem
, vol.73
, pp. 2221-2228
-
-
Brasuel, M.1
Kopelman, R.2
Miller, T.J.3
Tjalkens, R.4
Philbert, M.A.5
-
49
-
-
0035448944
-
A real-time ratiometric method for the determination of molecular oxygen inside living cells using sol-gelbased spherical optical nanosensors with applications to rat C6 glioma
-
Xu H, Aylott JW, Kopelman R, Miller TJ, Philbert MA. A real-time ratiometric method for the determination of molecular oxygen inside living cells using sol-gelbased spherical optical nanosensors with applications to rat C6 glioma. Anal Chem 2001;73:4124-4133.
-
(2001)
Anal Chem
, vol.73
, pp. 4124-4133
-
-
Xu, H.1
Aylott, J.W.2
Kopelman, R.3
Miller, T.J.4
Philbert, M.A.5
-
51
-
-
0347004627
-
In vitro sliding of actin filaments labelled with single quantum dots
-
Mansson A, et al. In vitro sliding of actin filaments labelled with single quantum dots. Biochem Biophys Res Commun 2004;314:529-534.
-
(2004)
Biochem Biophys Res Commun
, vol.314
, pp. 529-534
-
-
Mansson, A.1
-
52
-
-
33745497495
-
Multicolor quantum dots for molecular diagnostics of cancer
-
Smith AM, Dave S, Nie S, True L, Gao X. Multicolor quantum dots for molecular diagnostics of cancer. Expert Rev Mol Diagn 2006;6:231-244.
-
(2006)
Expert Rev Mol Diagn
, vol.6
, pp. 231-244
-
-
Smith, A.M.1
Dave, S.2
Nie, S.3
True, L.4
Gao, X.5
-
53
-
-
22844437953
-
Peptide-conjugated quantum dots, imaging the angiotensin type 1 receptor in living cells
-
Tomlinson ID, Mason JN, Blakely RD, Rosenthal SJ. Peptide-conjugated quantum dots: imaging the angiotensin type 1 receptor in living cells. Methods Mol Biol 2005;303:51-60.
-
(2005)
Methods Mol Biol
, vol.303
, pp. 51-60
-
-
Tomlinson, I.D.1
Mason, J.N.2
Blakely, R.D.3
Rosenthal, S.J.4
-
54
-
-
33748565326
-
Colloidal CdSe nanocrystals synthesized in noncoordinating solvents with the addition of a secondary ligand, exceptional growth kinetics
-
Dai Q, et al. Colloidal CdSe nanocrystals synthesized in noncoordinating solvents with the addition of a secondary ligand: exceptional growth kinetics. J Phys Chem B Condens Matter Mater Surf Interfaces Biophys 2006;110:16508-16513.
-
(2006)
J Phys Chem B Condens Matter Mater Surf Interfaces Biophys
, vol.110
, pp. 16508-16513
-
-
Dai, Q.1
-
55
-
-
0346250142
-
High quality CdSeS nanocrystals synthesized by facile single injection process and their electroluminescence
-
Jang E, Jun S, Pu L. High quality CdSeS nanocrystals synthesized by facile single injection process and their electroluminescence. Chem Commun (Camb) 2003: 2964-2965.
-
(2003)
Chem Commun (Camb)
, pp. 2964-2965
-
-
Jang, E.1
Jun, S.2
Pu, L.3
-
56
-
-
4544322054
-
Quantum dots tailored with poly(para-phenylene vinylene)
-
Skaff H, Sill K, Emrick T. Quantum dots tailored with poly(para-phenylene vinylene). J Am Chem Soc 2004;126:11322-11325.
-
(2004)
J Am Chem Soc
, vol.126
, pp. 11322-11325
-
-
Skaff, H.1
Sill, K.2
Emrick, T.3
-
57
-
-
0141922795
-
New synthetic routes for quantum dots
-
discussion 310
-
Crouch D, Norager S, O'Brien P, Park JH, Pickett N. New synthetic routes for quantum dots. Philos Trans A Math Phys Eng Sci 2003;361.297-310. discussion 310
-
(2003)
Philos Trans A Math Phys Eng Sci
, vol.361
, pp. 297-310
-
-
Crouch, D.1
Norager, S.2
O'Brien, P.3
Park, J.H.4
Pickett, N.5
-
58
-
-
0346725932
-
The use of nanocrystals in biological detection
-
Alivisatos P. The use of nanocrystals in biological detection. Nat Biotechnol 2004;22:47-52.
-
(2004)
Nat Biotechnol
, vol.22
, pp. 47-52
-
-
Alivisatos, P.1
-
59
-
-
0032566763
-
Quantum dot bioconjugates for ultrasensitive nonisotopic detection
-
Chan WC and Nie S. Quantum dot bioconjugates for ultrasensitive nonisotopic detection. Science 1998;281:2016-2018.
-
(1998)
Science
, vol.281
, pp. 2016-2018
-
-
Chan, W.C.1
Nie, S.2
-
60
-
-
3543022686
-
In vivo cancer targeting and imaging with semiconductor quantum dots
-
Gao X, Cui Y, Levenson RM, Chung LW, Nie S. In vivo cancer targeting and imaging with semiconductor quantum dots. Nat Biotechnol 2004;22:969-976
-
(2004)
Nat Biotechnol
, vol.22
, pp. 969-976
-
-
Gao, X.1
Cui, Y.2
Levenson, R.M.3
Chung, L.W.4
Nie, S.5
-
61
-
-
0037225979
-
Immunofluorescent labeling of cancer marker Her2 and other cellular targets with semiconductor quantum dots
-
Wu X, et al. Immunofluorescent labeling of cancer marker Her2 and other cellular targets with semiconductor quantum dots. Nat Biotechnol 2003;21:41-46.
-
(2003)
Nat Biotechnol
, vol.21
, pp. 41-46
-
-
Wu, X.1
-
62
-
-
0348087040
-
Long-term multiple color imaging of live cells using quantum dot bioconjugates
-
Jaiswal JK, Mattoussi H, Mauro JM, Simon SM. Long-term multiple color imaging of live cells using quantum dot bioconjugates. Nat Biotechnol 2003;21:47-51.
-
(2003)
Nat Biotechnol
, vol.21
, pp. 47-51
-
-
Jaiswal, J.K.1
Mattoussi, H.2
Mauro, J.M.3
Simon, S.M.4
-
63
-
-
3142782243
-
Intracellular delivery of quantum dots for live cell labeling and organelle tracking
-
Derfus AM, Chan WCW, Bhatia SN. Intracellular delivery of quantum dots for live cell labeling and organelle tracking. Adv Mater 2004;16:961-966.
-
(2004)
Adv Mater
, vol.16
, pp. 961-966
-
-
Derfus, A.M.1
Chan, W.C.W.2
Bhatia, S.N.3
-
64
-
-
0037059050
-
Monitoring of implanted stem cell migration in vivo, a highly resolved in vivo magnetic resonance imaging investigation of experimental stroke in rat
-
Hoehn M, et al. Monitoring of implanted stem cell migration in vivo: a highly resolved in vivo magnetic resonance imaging investigation of experimental stroke in rat. Proc Natl Acad Sci USA 2002;99:16267-16272.
-
(2002)
Proc Natl Acad Sci USA
, vol.99
, pp. 16267-16272
-
-
Hoehn, M.1
-
65
-
-
0028857592
-
In vivo dynamic MRI tracking of rat T-cells labeled with superparamagnetic iron-oxide particles
-
Yeh TC, Zhang W, Ildstad ST, Ho C. In vivo dynamic MRI tracking of rat T-cells labeled with superparamagnetic iron-oxide particles. Magn Reson Med 1995;33: 200-208.
-
(1995)
Magn Reson Med
, vol.33
, pp. 200-208
-
-
Yeh, T.C.1
Zhang, W.2
Ildstad, S.T.3
Ho, C.4
-
66
-
-
0035659557
-
MR imaging of murine arthritis using ultrasmall superparamagnetic iron oxide particles
-
Dardzinski BJ, et al. MR imaging of murine arthritis using ultrasmall superparamagnetic iron oxide particles. Magn Reson Imaging 2001;19:1209-1216.
-
(2001)
Magn Reson Imaging
, vol.19
, pp. 1209-1216
-
-
Dardzinski, B.J.1
-
67
-
-
27644542061
-
Medical application of functionalized magnetic nanoparticles
-
Ito A, Shinkai M, Honda H, Kobayashi T. Medical application of functionalized magnetic nanoparticles. J Biosci Bioeng 2005;100:1-11.
-
(2005)
J Biosci Bioeng
, vol.100
, pp. 1-11
-
-
Ito, A.1
Shinkai, M.2
Honda, H.3
Kobayashi, T.4
-
68
-
-
0043245963
-
Highly efficient endosomal labeling of progenitor and stem cells with large magnetic particles allows magnetic resonance imaging of single cells
-
Hinds KA, et al. Highly efficient endosomal labeling of progenitor and stem cells with large magnetic particles allows magnetic resonance imaging of single cells. Blood 2003;102:867-872.
-
(2003)
Blood
, vol.102
, pp. 867-872
-
-
Hinds, K.A.1
-
69
-
-
3342929290
-
MRI detection of single particles for cellular imaging
-
Shapiro EM, et al. MRI detection of single particles for cellular imaging. Proc Natl Acad Sci USA 2004;101:10901-10906.
-
(2004)
Proc Natl Acad Sci USA
, vol.101
, pp. 10901-10906
-
-
Shapiro, E.M.1
-
70
-
-
0042092068
-
Combination of transfection agents and magnetic resonance contrast agents for cellular imaging, relationship between relaxivities, electrostatic forces, and chemical composition
-
Kalish H, et al. Combination of transfection agents and magnetic resonance contrast agents for cellular imaging: relationship between relaxivities, electrostatic forces, and chemical composition. Magn Reson Med 2003;50:275-282.
-
(2003)
Magn Reson Med
, vol.50
, pp. 275-282
-
-
Kalish, H.1
-
71
-
-
0032860381
-
In vitro diagnostics in diabetes, meeting the challenge
-
Turner AP, Chen B, Piletsky SA. In vitro diagnostics in diabetes: meeting the challenge. Clin Chem 1999;45:1596-1601.
-
(1999)
Clin Chem
, vol.45
, pp. 1596-1601
-
-
Turner, A.P.1
Chen, B.2
Piletsky, S.A.3
-
72
-
-
0034225190
-
Enzyme-based biosensors for in vivo measurements
-
Wilson GS and Hu Y. Enzyme-based biosensors for in vivo measurements. Chem Rev 2000;100:2693-2704.
-
(2000)
Chem Rev
, vol.100
, pp. 2693-2704
-
-
Wilson, G.S.1
Hu, Y.2
-
73
-
-
18044389554
-
Home blood glucose biosensors, a commercial perspective
-
Newman JD and Turner AP. Home blood glucose biosensors: a commercial perspective. Biosens Bioelectron 2005;20:2435-2453.
-
(2005)
Biosens Bioelectron
, vol.20
, pp. 2435-2453
-
-
Newman, J.D.1
Turner, A.P.2
-
74
-
-
14644392814
-
In vivo glucose monitoring, the clinical reality and the promise
-
Pickup JC, Hussain F, Evans ND, Sachedina N. In vivo glucose monitoring: the clinical reality and the promise. Biosens Bioelectron 2005;20:1897-1902.
-
(2005)
Biosens Bioelectron
, vol.20
, pp. 1897-1902
-
-
Pickup, J.C.1
Hussain, F.2
Evans, N.D.3
Sachedina, N.4
-
75
-
-
0026452076
-
Microdialysis measurement of the absolute glucose concentration in subcutaneous adipose tissue allowing glucose monitoring in diabetic patients
-
Bolinder J, Ungerstedt U, Arner P. Microdialysis measurement of the absolute glucose concentration in subcutaneous adipose tissue allowing glucose monitoring in diabetic patients. Diabetologia 1992;35:1177-1180.
-
(1992)
Diabetologia
, vol.35
, pp. 1177-1180
-
-
Bolinder, J.1
Ungerstedt, U.2
Arner, P.3
-
76
-
-
0001023689
-
Epidemiology of urinary tract infection
-
Nicolle L. Epidemiology of urinary tract infection. Infect Med 2001;18:153-162.
-
(2001)
Infect Med
, vol.18
, pp. 153-162
-
-
Nicolle, L.1
-
77
-
-
32344432775
-
Use of electrochemical DNA biosensors for rapid molecular identification of uropathogens in clinical urine specimens
-
Liao JC, et al. Use of electrochemical DNA biosensors for rapid molecular identification of uropathogens in clinical urine specimens. J Clin Microbiol 2006;44:561-570.
-
(2006)
J Clin Microbiol
, vol.44
, pp. 561-570
-
-
Liao, J.C.1
-
78
-
-
0037179938
-
Electrochemical nucleic acid biosensors
-
Wang J. Electrochemical nucleic acid biosensors. Anal Chim Acta 2002;469: 63-71.
-
(2002)
Anal Chim Acta
, vol.469
, pp. 63-71
-
-
Wang, J.1
-
80
-
-
0036137922
-
Enzyme-amplified amperometric sandwich test for RNA and DNA
-
Campbell CN, Gal D, Cristler N, Banditrat C, Heller A. Enzyme-amplified amperometric sandwich test for RNA and DNA. Anal Chem 2002;74:158-162
-
(2002)
Anal Chem
, vol.74
, pp. 158-162
-
-
Campbell, C.N.1
Gal, D.2
Cristler, N.3
Banditrat, C.4
Heller, A.5
-
81
-
-
0842329030
-
An integrated approach to a portable and low-cost immunoassay for resource-poor settings
-
Sia SK, Linder V, Parviz BA, Siegel A, Whitesides GM. An integrated approach to a portable and low-cost immunoassay for resource-poor settings. Angew Chem Int Ed Engl 2004;43:498-502.
-
(2004)
Angew Chem Int Ed Engl
, vol.43
, pp. 498-502
-
-
Sia, S.K.1
Linder, V.2
Parviz, B.A.3
Siegel, A.4
Whitesides, G.M.5
-
82
-
-
0036646556
-
A microchip-based multianalyte assay system for the assessment of cardiac risk
-
Christodoulides N, et al. A microchip-based multianalyte assay system for the assessment of cardiac risk. Anal Chem 2002;74:3030-3036.
-
(2002)
Anal Chem
, vol.74
, pp. 3030-3036
-
-
Christodoulides, N.1
-
83
-
-
29144481982
-
A 5'-nuclease real-time reverse transcriptasepolymerase chain reaction assay for the detection of a broad range of influenza A subtypes, including H5N1
-
Whiley DM and Sloots TP. A 5'-nuclease real-time reverse transcriptasepolymerase chain reaction assay for the detection of a broad range of influenza A subtypes, including H5N1. Diagn Microbiol Infect Dis 2005;53:335-337.
-
(2005)
Diagn Microbiol Infect Dis
, vol.53
, pp. 335-337
-
-
Whiley, D.M.1
Sloots, T.P.2
-
84
-
-
17144390763
-
ELISA as a possible alternative to the neutralization test for evaluating the immune response to poliovirus vaccines
-
Ivanov AP and Dragunsky EM. ELISA as a possible alternative to the neutralization test for evaluating the immune response to poliovirus vaccines. Expert Rev Vaccines 2005;4:167-172.
-
(2005)
Expert Rev Vaccines
, vol.4
, pp. 167-172
-
-
Ivanov, A.P.1
Dragunsky, E.M.2
-
85
-
-
0032915408
-
Misdiagnosis of HIV infection by HIV-1 plasma viral load testing, a case series
-
Rich JD, et al. Misdiagnosis of HIV infection by HIV-1 plasma viral load testing: a case series. Ann Intern Med 1999;130:37-39.
-
(1999)
Ann Intern Med
, vol.130
, pp. 37-39
-
-
Rich, J.D.1
-
86
-
-
0035166438
-
Simultaneous detection of influenza viruses A and B using real-time quantitative PCR
-
van Elden LJ, Nijhuis M, Schipper P, Schuurman R, van Loon AM. Simultaneous detection of influenza viruses A and B using real-time quantitative PCR. J Clin Microbiol 2001;39:196-200.
-
(2001)
J Clin Microbiol
, vol.39
, pp. 196-200
-
-
van Elden, L.J.1
Nijhuis, M.2
Schipper, P.3
Schuurman, R.4
van Loon, A.M.5
-
88
-
-
0034282271
-
Implementing surface plasmon resonance biosensors in drug discovery
-
Myszka DG and Rich RL. Implementing surface plasmon resonance biosensors in drug discovery. Pharm Sci Technol Today 2000;3:310-317.
-
(2000)
Pharm Sci Technol Today
, vol.3
, pp. 310-317
-
-
Myszka, D.G.1
Rich, R.L.2
-
89
-
-
0025502197
-
Detection of antigen-antibody interactions by surface plasmon resonance
-
Fagerstam LG, et al. Detection of antigen-antibody interactions by surface plasmon resonance. Application to epitope mapping. J Mol Recognit 1990;3: 208-214.
-
(1990)
Application to epitope mapping. J Mol Recognit
, vol.3
, pp. 208-214
-
-
Fagerstam, L.G.1
-
90
-
-
0034744992
-
P1/P10 modified HIV protease inhibitors as tools in two new sensitive surface plasmon resonance biosensor screening assays
-
Alterman M, et al. P1/P10 modified HIV protease inhibitors as tools in two new sensitive surface plasmon resonance biosensor screening assays. Eur J Pharm Sci 2001;13:203-212.
-
(2001)
Eur J Pharm Sci
, vol.13
, pp. 203-212
-
-
Alterman, M.1
-
92
-
-
33745959582
-
Nanotechnology for cancer diagnostics, promises and challenges
-
Grodzinski P, Silver M, Molnar LK. Nanotechnology for cancer diagnostics: promises and challenges. Expert Rev Mol Diagn 2006;6:307-318.
-
(2006)
Expert Rev Mol Diagn
, vol.6
, pp. 307-318
-
-
Grodzinski, P.1
Silver, M.2
Molnar, L.K.3
-
93
-
-
0035992272
-
Cytogenetic evidence that circulating epithelial cells in patients with carcinoma are malignant
-
Fehm T, et al. Cytogenetic evidence that circulating epithelial cells in patients with carcinoma are malignant. Clin Cancer Res 2002;8:2073-2084.
-
(2002)
Clin Cancer Res
, vol.8
, pp. 2073-2084
-
-
Fehm, T.1
-
94
-
-
4143094988
-
Circulating tumor cells, disease progression, and survival in metastatic breast cancer
-
Cristofanilli M, et al. Circulating tumor cells, disease progression, and survival in metastatic breast cancer. N Engl J Med 2004;351:781-791.
-
(2004)
N Engl J Med
, vol.351
, pp. 781-791
-
-
Cristofanilli, M.1
-
95
-
-
0242352423
-
Preoperative detection of peripherally circulating cancer cells and its prognostic significance in ovarian cancer
-
Judson PL, et al. Preoperative detection of peripherally circulating cancer cells and its prognostic significance in ovarian cancer. Gynecol Oncol 2003;91:389-394
-
(2003)
Gynecol Oncol
, vol.91
, pp. 389-394
-
-
Judson, P.L.1
-
96
-
-
0034867029
-
Changes in circulating carcinoma cells in patients with metastatic prostate cancer correlate with disease status
-
Moreno JG, et al. Changes in circulating carcinoma cells in patients with metastatic prostate cancer correlate with disease status. Urology 2001;58:386-392.
-
(2001)
Urology
, vol.58
, pp. 386-392
-
-
Moreno, J.G.1
-
98
-
-
0742276712
-
Optimisation of the RT-PCR detection of immunomagnetically enriched carcinoma cells
-
Raynor M, Stephenson SA, Walsh DC, Pittman KB, Dobrovic A. Optimisation of the RT-PCR detection of immunomagnetically enriched carcinoma cells. BMC Cancer 2002;2:14.
-
(2002)
BMC Cancer
, vol.2
, pp. 14
-
-
Raynor, M.1
Stephenson, S.A.2
Walsh, D.C.3
Pittman, K.B.4
Dobrovic, A.5
-
99
-
-
20444477166
-
Global gene expression profiling of circulating tumor cells
-
Smirnov DA, et al. Global gene expression profiling of circulating tumor cells. Cancer Res 2005;65:4993-4997.
-
(2005)
Cancer Res
, vol.65
, pp. 4993-4997
-
-
Smirnov, D.A.1
-
100
-
-
20044364940
-
Clinical and biological features associated with epidermal growth factor receptor gene mutations in lung cancers
-
Shigematsu H, et al. Clinical and biological features associated with epidermal growth factor receptor gene mutations in lung cancers. J Natl Cancer Inst 2005;97:339-346.
-
(2005)
J Natl Cancer Inst
, vol.97
, pp. 339-346
-
-
Shigematsu, H.1
-
101
-
-
17144426134
-
Circulating tumor cells predict survival in patients with metastatic prostate cancer
-
Moreno JG, et al. Circulating tumor cells predict survival in patients with metastatic prostate cancer. Urology 2005;65:713-718.
-
(2005)
Urology
, vol.65
, pp. 713-718
-
-
Moreno, J.G.1
-
102
-
-
12144287967
-
Impact of cytomorphological detection of circulating tumor cells in patients with liver cancer
-
Vona G, et al. Impact of cytomorphological detection of circulating tumor cells in patients with liver cancer. Hepatology 2004;39:792-797.
-
(2004)
Hepatology
, vol.39
, pp. 792-797
-
-
Vona, G.1
-
103
-
-
0036091226
-
Detection of circulating cytokeratin-positive cells in the blood of breast cancer patients using immunomagnetic enrichment and digital microscopy
-
Witzig T.E, et al. Detection of circulating cytokeratin-positive cells in the blood of breast cancer patients using immunomagnetic enrichment and digital microscopy. Clin Cancer Res 2002;8:1085-1091.
-
(2002)
Clin Cancer Res
, vol.8
, pp. 1085-1091
-
-
Witzig, T.E.1
-
105
-
-
27444444117
-
Increase in number of circulating disseminated epithelial cells after surgery for non-small cell lung cancer monitored by MAINTRAC is a predictor for relapse, a preliminary report
-
Rolle A, et al. Increase in number of circulating disseminated epithelial cells after surgery for non-small cell lung cancer monitored by MAINTRAC is a predictor for relapse: a preliminary report. World J Surg Oncol 2005;3:18.
-
(2005)
World J Surg Oncol
, vol.3
, pp. 18
-
-
Rolle, A.1
-
106
-
-
2142822261
-
Multigene reverse transcription-PCR profiling of circulating tumor cells in hormone-refractory prostate cancer
-
O'Hara SM, et al. Multigene reverse transcription-PCR profiling of circulating tumor cells in hormone-refractory prostate cancer. Clin Chem 2004;50:826-835.
-
(2004)
Clin Chem
, vol.50
, pp. 826-835
-
-
O'Hara, S.M.1
-
107
-
-
0023180716
-
Immunohistochemical study of the expression of a Mr 34 000 human epithelium-specific surface glycoprotein in normal and malignant tissues
-
Momburg F, Moldenhauer G, Hammerling GJ, Moller P. Immunohistochemical study of the expression of a Mr 34,000 human epithelium-specific surface glycoprotein in normal and malignant tissues. Cancer Res 1987;47:2883-2891.
-
(1987)
Cancer Res
, vol.47
, pp. 2883-2891
-
-
Momburg, F.1
Moldenhauer, G.2
Hammerling, G.J.3
Moller, P.4
-
108
-
-
0026441539
-
Identification of malignant cells in serous effusions using a panel of monoclonal antibodies Ber-EP4 MCA-b-12 and EMA
-
Stoop JA, Hendriks JG, Berends D. Identification of malignant cells in serous effusions using a panel of monoclonal antibodies Ber-EP4, MCA-b-12 and EMA. Cytopathology 1992;3:297-302.
-
(1992)
Cytopathology
, vol.3
, pp. 297-302
-
-
Stoop, J.A.1
Hendriks, J.G.2
Berends, D.3
-
109
-
-
0026734507
-
Immunoreactivity for BER-EP4 in adenocarcinomas, adenomatoid tumors, and malignant mesotheliomas
-
Gaffey MJ, et al. Immunoreactivity for BER-EP4 in adenocarcinomas, adenomatoid tumors, and malignant mesotheliomas. Am J Surg Pathol 1992;16: 593-599.
-
(1992)
Am J Surg Pathol
, vol.16
, pp. 593-599
-
-
Gaffey, M.J.1
-
110
-
-
24644451986
-
Expression of epithelial cell adhesion molecule in carcinoma cells present in blood and primary and metastatic tumors
-
Rao CG, et al. Expression of epithelial cell adhesion molecule in carcinoma cells present in blood and primary and metastatic tumors. Int J Oncol 2005;27:49-57.
-
(2005)
Int J Oncol
, vol.27
, pp. 49-57
-
-
Rao, C.G.1
-
111
-
-
10644285795
-
Development of a rare cell fractionation device, application for cancer detection
-
Mohamed H, et al. Development of a rare cell fractionation device: application for cancer detection. IEEE Trans Nanobiosci 2004;3:251-256.
-
(2004)
IEEE Trans Nanobiosci
, vol.3
, pp. 251-256
-
-
Mohamed, H.1
-
112
-
-
0345166901
-
-
Shelby JP, White J, Ganesan K, Rathod PK, Chiu DT. A microfluidic model for single-cell capillary obstruction by Plasmodium falciparum-infected erythrocytes. Proc Natl Acad Sci USA 2003;100:14618-14622.
-
(2003)
A microfluidic model for single-cell capillary obstruction by Plasmodium falciparum-infected erythrocytes. Proc Natl Acad Sci USA
, vol.100
, pp. 14618-14622
-
-
Shelby, J.P.1
White, J.2
Ganesan, K.3
Rathod, P.K.4
Chiu, D.T.5
-
113
-
-
7444223607
-
Nanoparticle-aptamer bioconjugates, a new approach for targeting prostate cancer cells
-
Farokhzad OC, et al. Nanoparticle-aptamer bioconjugates: a new approach for targeting prostate cancer cells. Cancer Res 2004;64:7668-7672.
-
(2004)
Cancer Res
, vol.64
, pp. 7668-7672
-
-
Farokhzad, O.C.1
-
114
-
-
0038469746
-
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
-
Harishinghani MG, et al. Noninvasive detection of clinically occult lymph-node metastases in prostate cancer. N Engl J Med 2003; 348:2491-2499.
-
(2003)
N Engl J Med
, vol.348
, pp. 2491-2499
-
-
Harishinghani, M.G.1
-
115
-
-
0035876435
-
A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout
-
Battiston FM, et al. A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout. Sens Actuators 2001;77:122-131.
-
(2001)
Sens Actuators
, vol.77
, pp. 122-131
-
-
Battiston, F.M.1
|