-
1
-
-
34147150632
-
Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030
-
Kurtz S., Ong K., Lau E., Mowat F., Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg - Ser A 2007, 89:780-785.
-
(2007)
J Bone Joint Surg - Ser A
, vol.89
, pp. 780-785
-
-
Kurtz, S.1
Ong, K.2
Lau, E.3
Mowat, F.4
Halpern, M.5
-
2
-
-
51249109058
-
Knee implants - review of models and biomechanics
-
Carr B.C., Goswami T. Knee implants - review of models and biomechanics. Mater Des 2009, 30:398-413.
-
(2009)
Mater Des
, vol.30
, pp. 398-413
-
-
Carr, B.C.1
Goswami, T.2
-
4
-
-
0023868759
-
The results of revision total knee arthroplasty
-
Goldberg V.M., Figgie M.P., Figgie H.E., Sobel M. The results of revision total knee arthroplasty. Clin Orthop Relat Res 1988, 226:86-92.
-
(1988)
Clin Orthop Relat Res
, vol.226
, pp. 86-92
-
-
Goldberg, V.M.1
Figgie, M.P.2
Figgie, H.E.3
Sobel, M.4
-
5
-
-
55549108376
-
Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening?
-
Joshi N., Navarro-Quilis A. Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening?. J Arthroplasty 2008, 23:1204-1211.
-
(2008)
J Arthroplasty
, vol.23
, pp. 1204-1211
-
-
Joshi, N.1
Navarro-Quilis, A.2
-
6
-
-
33748801196
-
Failure analysis of total knee replacement: basics and methodological aspects of the damage analysis
-
Bader R., Mittelmeier W., Steinhauser E. Failure analysis of total knee replacement: basics and methodological aspects of the damage analysis. Orthopade 2006, 35:896-903.
-
(2006)
Orthopade
, vol.35
, pp. 896-903
-
-
Bader, R.1
Mittelmeier, W.2
Steinhauser, E.3
-
7
-
-
77952093799
-
Aseptic versus septic revision total knee arthroplasty: patient satisfaction, outcome and quality of life improvement
-
Patil N., Lee K., Huddleston J.I., Harris A.H.S., Goodman S.B. Aseptic versus septic revision total knee arthroplasty: patient satisfaction, outcome and quality of life improvement. Knee 2010, 17:200-203.
-
(2010)
Knee
, vol.17
, pp. 200-203
-
-
Patil, N.1
Lee, K.2
Huddleston, J.I.3
Harris, A.H.S.4
Goodman, S.B.5
-
8
-
-
0023890816
-
A comparison of primary and revision total knee arthroplasty using the kinematic stabilizer prosthesis
-
Hanssen A., Rand J. A comparison of primary and revision total knee arthroplasty using the kinematic stabilizer prosthesis. J Bone Joint Surg 1988, 70:491.
-
(1988)
J Bone Joint Surg
, vol.70
, pp. 491
-
-
Hanssen, A.1
Rand, J.2
-
9
-
-
0025284707
-
Results of revision total knee arthroplasty performed for aseptic loosening
-
Friedman R.J., Hirst P., Poss R., Kelley K., Sledge C.B. Results of revision total knee arthroplasty performed for aseptic loosening. Clin Orthop Relat Res 1990, 255:235-241.
-
(1990)
Clin Orthop Relat Res
, vol.255
, pp. 235-241
-
-
Friedman, R.J.1
Hirst, P.2
Poss, R.3
Kelley, K.4
Sledge, C.B.5
-
10
-
-
0032143529
-
Materials selection and design for orthopaedic implants with improved long-term performance
-
Sloten J.V., Labey L., Audekercke R.V., Perre G.V. Materials selection and design for orthopaedic implants with improved long-term performance. Biomaterials 1998, 19:1455-1459.
-
(1998)
Biomaterials
, vol.19
, pp. 1455-1459
-
-
Sloten, J.V.1
Labey, L.2
Audekercke, R.V.3
Perre, G.V.4
-
11
-
-
0036533211
-
Knee arthoplasty: recently developed ceramics offer new solutions
-
Heimke G., Leyen S., Willmann G. Knee arthoplasty: recently developed ceramics offer new solutions. Biomaterials 2002, 23:1539-1551.
-
(2002)
Biomaterials
, vol.23
, pp. 1539-1551
-
-
Heimke, G.1
Leyen, S.2
Willmann, G.3
-
12
-
-
0035145732
-
Changes in bone density after cemented total knee arthroplasty: influence of stem design
-
Lonner J., Klotz M., Levitz C., Lotke P. Changes in bone density after cemented total knee arthroplasty: influence of stem design. J Arthroplasty 2001, 16:107-111.
-
(2001)
J Arthroplasty
, vol.16
, pp. 107-111
-
-
Lonner, J.1
Klotz, M.2
Levitz, C.3
Lotke, P.4
-
14
-
-
0035171805
-
Problems with cementless total knee arthroplasty at 11years followup
-
Berger R.A., Lyon J.H., Jacobs J.J., Barden R.M., Berkson E.M., Sheinkop M.B., et al. Problems with cementless total knee arthroplasty at 11years followup. Clin Orthop Relat Res 2001, 392:196-207.
-
(2001)
Clin Orthop Relat Res
, vol.392
, pp. 196-207
-
-
Berger, R.A.1
Lyon, J.H.2
Jacobs, J.J.3
Barden, R.M.4
Berkson, E.M.5
Sheinkop, M.B.6
-
15
-
-
84903321223
-
Hybrid component fixation in total knee arthroplasty. Minimum of 10-year follow-up study
-
Yang J.H., Yoon J.R., Oh C.H., Kim T.S. Hybrid component fixation in total knee arthroplasty. Minimum of 10-year follow-up study. J Arthroplasty 2011.
-
(2011)
J Arthroplasty
-
-
Yang, J.H.1
Yoon, J.R.2
Oh, C.H.3
Kim, T.S.4
-
16
-
-
84863316462
-
Current concepts review-wear in total hip and knee replacements;
-
Thomas P.S., John J.C. Current concepts review-wear in total hip and knee replacements. J Bone Joint Surg (Am) 1999, 81:115-136.
-
(1999)
J Bone Joint Surg (Am)
, vol.81
, pp. 115-136
-
-
Thomas, P.S.1
John, J.C.2
-
17
-
-
1942434585
-
Review of wear mechanisms in hip implants: paper I - general
-
Buford A., Goswami T. Review of wear mechanisms in hip implants: paper I - general. Mater Des 2004, 25:385-393.
-
(2004)
Mater Des
, vol.25
, pp. 385-393
-
-
Buford, A.1
Goswami, T.2
-
18
-
-
0026550544
-
The mechanism of loosening of cemented acetabular components in total hip arthroplasty: analysis of specimens retrieved at autopsy
-
Schmalzried T.P., Kwong L.M., Jasty M., Sedlacek R.C., Haire T.C., O'Connor D.O., et al. The mechanism of loosening of cemented acetabular components in total hip arthroplasty: analysis of specimens retrieved at autopsy. Clin Orthop Relat Res 1992, 274:60-78.
-
(1992)
Clin Orthop Relat Res
, vol.274
, pp. 60-78
-
-
Schmalzried, T.P.1
Kwong, L.M.2
Jasty, M.3
Sedlacek, R.C.4
Haire, T.C.5
O'Connor, D.O.6
-
19
-
-
0024058346
-
Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report
-
Engh G.A. Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report. J Bone Joint Surg - Ser A 1988, 70:1093-1096.
-
(1988)
J Bone Joint Surg - Ser A
, vol.70
, pp. 1093-1096
-
-
Engh, G.A.1
-
20
-
-
0030345394
-
3-Dimensional sliding/contact computational simulation of total hip wear
-
Maxian T.A., Brown T.D., Pedersen D.R., Callaghan J.J. 3-Dimensional sliding/contact computational simulation of total hip wear. Clin Orthop Relat Res 1996, 333:41-50.
-
(1996)
Clin Orthop Relat Res
, vol.333
, pp. 41-50
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
21
-
-
1842297586
-
Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty
-
Engh C.A., Culpepper Ii W.J., Engh C.A. Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg - Ser A 1997, 79:177-184.
-
(1997)
J Bone Joint Surg - Ser A
, vol.79
, pp. 177-184
-
-
Engh, C.A.1
Culpepper Ii, W.J.2
Engh, C.A.3
-
22
-
-
0028929254
-
Isolation of predominantly submicron sized UHMWPE wear particles from periprosthetic tissues
-
Campbell P., Ma S., Yeom B., McKellop H., Schmalzried T., Amstutz H. Isolation of predominantly submicron sized UHMWPE wear particles from periprosthetic tissues. J Biomed Mater Res 1995, 29:127-131.
-
(1995)
J Biomed Mater Res
, vol.29
, pp. 127-131
-
-
Campbell, P.1
Ma, S.2
Yeom, B.3
McKellop, H.4
Schmalzried, T.5
Amstutz, H.6
-
23
-
-
0001084495
-
Wear debris in total joint replacements
-
Jacobs J.J., Shanbhag A., Glant T.T., Black J., Galante J.O. Wear debris in total joint replacements. J Am Acad Orthopaed Surg 1994, 2:212.
-
(1994)
J Am Acad Orthopaed Surg
, vol.2
, pp. 212
-
-
Jacobs, J.J.1
Shanbhag, A.2
Glant, T.T.3
Black, J.4
Galante, J.O.5
-
24
-
-
79751534986
-
Reliability assessment in advanced nanocomposite materials for orthopaedic applications
-
Chevalier J., Taddei P., Gremillard L., Deville S., Fantozzi G., Bartolomé J., et al. Reliability assessment in advanced nanocomposite materials for orthopaedic applications. J Mech Behav Biomed Mater 2011, 4:303-314.
-
(2011)
J Mech Behav Biomed Mater
, vol.4
, pp. 303-314
-
-
Chevalier, J.1
Taddei, P.2
Gremillard, L.3
Deville, S.4
Fantozzi, G.5
Bartolomé, J.6
-
26
-
-
0027304584
-
Bone resorption activity of particulate stimulated macrophages
-
Glant T.T., Jacobs J.J., Molnár G., Shanbhag A.S., Valyon M., Galante J.O. Bone resorption activity of particulate stimulated macrophages. J Bone Miner Res 1993, 8:1071-1079.
-
(1993)
J Bone Miner Res
, vol.8
, pp. 1071-1079
-
-
Glant, T.T.1
Jacobs, J.J.2
Molnár, G.3
Shanbhag, A.S.4
Valyon, M.5
Galante, J.O.6
-
27
-
-
4744355541
-
The role of macrophages in osteolysis of total joint replacement
-
Ingham E., Fisher J. The role of macrophages in osteolysis of total joint replacement. Biomaterials 2005, 26:1271-1286.
-
(2005)
Biomaterials
, vol.26
, pp. 1271-1286
-
-
Ingham, E.1
Fisher, J.2
-
28
-
-
0028580091
-
Osteolysis of the distal femur after total knee arthroplasty
-
Cadambi A., Engh G.A., Dwyer K.A., Vinh T.N. Osteolysis of the distal femur after total knee arthroplasty. J Arthroplasty 1994, 9:579-594.
-
(1994)
J Arthroplasty
, vol.9
, pp. 579-594
-
-
Cadambi, A.1
Engh, G.A.2
Dwyer, K.A.3
Vinh, T.N.4
-
29
-
-
0036898690
-
Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees
-
Huang C.H., Ma H.M., Liau J.J., Ho F.Y., Cheng C.K. Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees. J Bone Joint Surg Am 2002, 84:2224-2229.
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 2224-2229
-
-
Huang, C.H.1
Ma, H.M.2
Liau, J.J.3
Ho, F.Y.4
Cheng, C.K.5
-
30
-
-
34548421415
-
Review article: osteolysis after total knee arthroplasty
-
Gupta S.K., Chu A., Ranawat A.S., Slamin J., Ranawat C.S. Review article: osteolysis after total knee arthroplasty. J Arthroplasty 2007, 22:787-799.
-
(2007)
J Arthroplasty
, vol.22
, pp. 787-799
-
-
Gupta, S.K.1
Chu, A.2
Ranawat, A.S.3
Slamin, J.4
Ranawat, C.S.5
-
31
-
-
0028923420
-
Osteolysis around cementless porous-coated anatomic knee prostheses
-
Kim Y.H., Oh J.H., Oh S.H. Osteolysis around cementless porous-coated anatomic knee prostheses. J Bone Joint Surg - Br Vol 1995, 77:236.
-
(1995)
J Bone Joint Surg - Br Vol
, vol.77
, pp. 236
-
-
Kim, Y.H.1
Oh, J.H.2
Oh, S.H.3
-
33
-
-
0026863992
-
Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty
-
Cheal E.J., Spector M., Hayes W.C. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty. J Orthop Res 1992, 10:405-422.
-
(1992)
J Orthop Res
, vol.10
, pp. 405-422
-
-
Cheal, E.J.1
Spector, M.2
Hayes, W.C.3
-
34
-
-
0026604141
-
The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
-
Huiskes R., Weinans H., Van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop 1992, 274:124-134.
-
(1992)
Clin Orthop
, vol.274
, pp. 124-134
-
-
Huiskes, R.1
Weinans, H.2
Van Rietbergen, B.3
-
35
-
-
0033059331
-
Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty?
-
Seki T., Omori G., Koga Y., Suzuki Y., Ishii Y., Takahashi H.E. Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty?. J Orthopaed Sci 1999, 4:180-186.
-
(1999)
J Orthopaed Sci
, vol.4
, pp. 180-186
-
-
Seki, T.1
Omori, G.2
Koga, Y.3
Suzuki, Y.4
Ishii, Y.5
Takahashi, H.E.6
-
36
-
-
3142596304
-
Periprosthetic femoral bone loss after total knee arthroplasty: 1-year follow-up study of 69 patients
-
Soininvaara T., Miettinen H., Jurvelin J., Suomalainen O., Alhava E., Kröger H. Periprosthetic femoral bone loss after total knee arthroplasty: 1-year follow-up study of 69 patients. Knee 2004, 11:297-302.
-
(2004)
Knee
, vol.11
, pp. 297-302
-
-
Soininvaara, T.1
Miettinen, H.2
Jurvelin, J.3
Suomalainen, O.4
Alhava, E.5
Kröger, H.6
-
37
-
-
48249143594
-
Comparison of peri-prosthetic bone density in cemented and uncemented total knee arthroplasty
-
Kamath S., Chang W., Shaari E., Bridges A., Campbell A., McGill P. Comparison of peri-prosthetic bone density in cemented and uncemented total knee arthroplasty. Acta Orthop Belg 2008, 74:354-359.
-
(2008)
Acta Orthop Belg
, vol.74
, pp. 354-359
-
-
Kamath, S.1
Chang, W.2
Shaari, E.3
Bridges, A.4
Campbell, A.5
McGill, P.6
-
38
-
-
0033018157
-
Femoral bone loss in total knee arthroplasty: a review
-
Van Loon C.J.M., De Waal Malefijt M.C., Buma P., Verdonschot N., Veth R.P.H. Femoral bone loss in total knee arthroplasty: a review. Acta Orthop Belg 1999, 65:154-163.
-
(1999)
Acta Orthop Belg
, vol.65
, pp. 154-163
-
-
Van Loon, C.J.M.1
De Waal Malefijt, M.C.2
Buma, P.3
Verdonschot, N.4
Veth, R.P.H.5
-
39
-
-
0029802253
-
Decreased bone density of the distal femur after uncemented knee arthroplasty. A 1-year follow-up of 29 knees
-
Petersen M.M., Lauritzen J.B., Pedersen J.G., Lund B. Decreased bone density of the distal femur after uncemented knee arthroplasty. A 1-year follow-up of 29 knees. Acta Orthop Scand 1996, 67:339-344.
-
(1996)
Acta Orthop Scand
, vol.67
, pp. 339-344
-
-
Petersen, M.M.1
Lauritzen, J.B.2
Pedersen, J.G.3
Lund, B.4
-
40
-
-
0035000279
-
Distal femoral bone mineral density after total knee arthroplasty: a comparison with general bone mineral density
-
Van Loon C.J.M., Oyen W.J.G., De Waal Malefijt M.C., Verdonschot N. Distal femoral bone mineral density after total knee arthroplasty: a comparison with general bone mineral density. Arch Orthop Trauma Surg 2001, 121:282-285.
-
(2001)
Arch Orthop Trauma Surg
, vol.121
, pp. 282-285
-
-
Van Loon, C.J.M.1
Oyen, W.J.G.2
De Waal Malefijt, M.C.3
Verdonschot, N.4
-
41
-
-
77950928207
-
Distal femoral bone mineral density decreases following patellofemoral arthroplasty: 1-year follow-up study of 14 patients
-
Van Jonbergen H.P.W., Koster K., Labey L., Innocenti B., Van Kampen A. Distal femoral bone mineral density decreases following patellofemoral arthroplasty: 1-year follow-up study of 14 patients. BMC Musculoskelet Disord 2010, 11.
-
(2010)
BMC Musculoskelet Disord
, vol.11
-
-
Van Jonbergen, H.P.W.1
Koster, K.2
Labey, L.3
Innocenti, B.4
Van Kampen, A.5
-
42
-
-
33750520524
-
Posterior stabilized component increased femoral bone loss after total knee replacement. 5-year follow-up of 47 knees using dual energy X-ray absorptiometry
-
Saari T., Uvehammer J., Carlsson L.V., Regnér L., Kärrholm J. Posterior stabilized component increased femoral bone loss after total knee replacement. 5-year follow-up of 47 knees using dual energy X-ray absorptiometry. Knee 2006, 13:435-439.
-
(2006)
Knee
, vol.13
, pp. 435-439
-
-
Saari, T.1
Uvehammer, J.2
Carlsson, L.V.3
Regnér, L.4
Kärrholm, J.5
-
43
-
-
0029561778
-
Periprosthetic bone mineral density of the distal femur after total knee arthroplasty
-
Liu T.K., Yang R.S., Chieng P.U., Shee B.W. Periprosthetic bone mineral density of the distal femur after total knee arthroplasty. Int Orthop 1995, 19:346-351.
-
(1995)
Int Orthop
, vol.19
, pp. 346-351
-
-
Liu, T.K.1
Yang, R.S.2
Chieng, P.U.3
Shee, B.W.4
-
44
-
-
0031016563
-
Stress shielding after total knee replacement may cause bone resorption in the distal femur
-
Van Lenthe G., De Waal Malefijt M., Huiskes R. Stress shielding after total knee replacement may cause bone resorption in the distal femur. J Bone Joint Surg - Br Vol 1997, 79:117-122.
-
(1997)
J Bone Joint Surg - Br Vol
, vol.79
, pp. 117-122
-
-
Van Lenthe, G.1
De Waal Malefijt, M.2
Huiskes, R.3
-
45
-
-
0028453984
-
The effects of micromotion and particulate materials on tissue differentiation. Bone chamber studies in rabbits
-
Goodman S.B. The effects of micromotion and particulate materials on tissue differentiation. Bone chamber studies in rabbits. Acta Orthop Scand Suppl 1994, 258:1-43.
-
(1994)
Acta Orthop Scand Suppl
, vol.258
, pp. 1-43
-
-
Goodman, S.B.1
-
46
-
-
33645776769
-
Aseptic loosening, not only a question of wear: a review of different theories
-
Sundfeldt M., Carlsson L.V., Johansson C.B., Thomsen P., Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop 2006, 77:177-197.
-
(2006)
Acta Orthop
, vol.77
, pp. 177-197
-
-
Sundfeldt, M.1
Carlsson, L.V.2
Johansson, C.B.3
Thomsen, P.4
Gretzer, C.5
-
47
-
-
61649127532
-
Ceramics for medical applications: a picture for the next 20years
-
Chevalier J., Gremillard L. Ceramics for medical applications: a picture for the next 20years. J Eur Ceram Soc 2009, 29:1245-1255.
-
(2009)
J Eur Ceram Soc
, vol.29
, pp. 1245-1255
-
-
Chevalier, J.1
Gremillard, L.2
-
48
-
-
0026536059
-
The effect of cement fixation on initial micromotion of the femoral component in condylar knee replacement
-
Wackerhagen A., Bodem F., Hopf C. The effect of cement fixation on initial micromotion of the femoral component in condylar knee replacement. Int Orthop 1992, 16:25-28.
-
(1992)
Int Orthop
, vol.16
, pp. 25-28
-
-
Wackerhagen, A.1
Bodem, F.2
Hopf, C.3
-
49
-
-
0029062186
-
Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller Galante I design
-
Nilsson K.G., Kärrholm J., Linder L. Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller Galante I design. J Orthop Res 1995, 13:347-356.
-
(1995)
J Orthop Res
, vol.13
, pp. 347-356
-
-
Nilsson, K.G.1
Kärrholm, J.2
Linder, L.3
-
50
-
-
58649112379
-
Implant fixation in knee replacement: preliminary in vitro comparison of ceramic and metal cemented femoral components
-
Cristofolini L., Affatato S., Erani P., Tigani D., Viceconti M. Implant fixation in knee replacement: preliminary in vitro comparison of ceramic and metal cemented femoral components. Knee 2009, 16:101-108.
-
(2009)
Knee
, vol.16
, pp. 101-108
-
-
Cristofolini, L.1
Affatato, S.2
Erani, P.3
Tigani, D.4
Viceconti, M.5
-
51
-
-
0033694357
-
The outcome of cemented vs. cementless fixation of a femoral component in total knee replacement (TKR) with the identification of radiological signs for the prediction of failure
-
Chockalingam S., Scott G. The outcome of cemented vs. cementless fixation of a femoral component in total knee replacement (TKR) with the identification of radiological signs for the prediction of failure. Knee 2000, 7:233-238.
-
(2000)
Knee
, vol.7
, pp. 233-238
-
-
Chockalingam, S.1
Scott, G.2
-
52
-
-
79957876576
-
Material selection for femoral component of total knee replacement using comprehensive VIKOR
-
Bahraminasab M., Jahan A. Material selection for femoral component of total knee replacement using comprehensive VIKOR. Mater Des 2011, 32:4471-4477.
-
(2011)
Mater Des
, vol.32
, pp. 4471-4477
-
-
Bahraminasab, M.1
Jahan, A.2
-
53
-
-
33751223851
-
Corrosion performance of the plasma nitrided 316L stainless steel
-
Gil L., Brühl S., Jimenez L., Leon O., Guevara R., Staia M.H. Corrosion performance of the plasma nitrided 316L stainless steel. Surf Coat Technol 2006, 201:4424-4429.
-
(2006)
Surf Coat Technol
, vol.201
, pp. 4424-4429
-
-
Gil, L.1
Brühl, S.2
Jimenez, L.3
Leon, O.4
Guevara, R.5
Staia, M.H.6
-
54
-
-
34248670151
-
Corrosion degradation and prevention by surface modification of biometallic materials
-
Singh R., Dahotre N.B. Corrosion degradation and prevention by surface modification of biometallic materials. J Mater Sci - Mater Med 2007, 18:725-751.
-
(2007)
J Mater Sci - Mater Med
, vol.18
, pp. 725-751
-
-
Singh, R.1
Dahotre, N.B.2
-
55
-
-
77954914721
-
Wear behaviour of UHMWPE against DC-pulsed plasma nitrided and duplex treated AISI 316L used in hip joint replacements
-
Perez E., Pazos L., Heras E.D.L., Parodi B., Corengia P., Braceras I. Wear behaviour of UHMWPE against DC-pulsed plasma nitrided and duplex treated AISI 316L used in hip joint replacements. Plasma Processes Polym 2009, 6:S75-S80.
-
(2009)
Plasma Processes Polym
, vol.6
-
-
Perez, E.1
Pazos, L.2
Heras, E.D.L.3
Parodi, B.4
Corengia, P.5
Braceras, I.6
-
56
-
-
79952192390
-
Wear assessment of plasma nitrided AISI H11 steel
-
Forati Rad H., Amadeh A., Moradi H. Wear assessment of plasma nitrided AISI H11 steel. Mater Des 2011, 32:2635-2643.
-
(2011)
Mater Des
, vol.32
, pp. 2635-2643
-
-
Forati Rad, H.1
Amadeh, A.2
Moradi, H.3
-
57
-
-
76949085274
-
Experimental investigation on corrosion and hardness of ion implanted AISI 316L stainless steel
-
Muthukumaran V., Selladurai V., Nandhakumar S., Senthilkumar M. Experimental investigation on corrosion and hardness of ion implanted AISI 316L stainless steel. Mater Des 2010, 31:2813-2817.
-
(2010)
Mater Des
, vol.31
, pp. 2813-2817
-
-
Muthukumaran, V.1
Selladurai, V.2
Nandhakumar, S.3
Senthilkumar, M.4
-
58
-
-
29244449606
-
Glow-discharge nitriding of AISI 316L austenitic stainless steel: influence of treatment temperature
-
Borgioli F., Fossati A., Galvanetto E., Bacci T. Glow-discharge nitriding of AISI 316L austenitic stainless steel: influence of treatment temperature. Surf Coat Technol 2005, 200:2474-2480.
-
(2005)
Surf Coat Technol
, vol.200
, pp. 2474-2480
-
-
Borgioli, F.1
Fossati, A.2
Galvanetto, E.3
Bacci, T.4
-
59
-
-
84855535901
-
The role of target-to-substrate distance on the DC magnetron sputtered zirconia thin films' bioactivity
-
Thaveedeetrakul A., Witit-Anun N., Boonamnuayvitaya V. The role of target-to-substrate distance on the DC magnetron sputtered zirconia thin films' bioactivity. Appl Surf Sci 2012, 258:2612-2619.
-
(2012)
Appl Surf Sci
, vol.258
, pp. 2612-2619
-
-
Thaveedeetrakul, A.1
Witit-Anun, N.2
Boonamnuayvitaya, V.3
-
60
-
-
76949102097
-
Improving the osteointegration and bone-implant interface by incorporation of bioactive particles in sol-gel coatings of stainless steel implants
-
Ballarre J., Manjubala I., Schreiner W.H., Orellano J.C., Fratzl P., Cere S. Improving the osteointegration and bone-implant interface by incorporation of bioactive particles in sol-gel coatings of stainless steel implants. Acta Biomater 2010, 6:1601-1609.
-
(2010)
Acta Biomater
, vol.6
, pp. 1601-1609
-
-
Ballarre, J.1
Manjubala, I.2
Schreiner, W.H.3
Orellano, J.C.4
Fratzl, P.5
Cere, S.6
-
61
-
-
9144249321
-
Biomaterials in total joint replacement
-
Kalpana S.K. Biomaterials in total joint replacement. Colloids Surf, B: Biointerf 2004, 39:133-142.
-
(2004)
Colloids Surf, B: Biointerf
, vol.39
, pp. 133-142
-
-
Kalpana, S.K.1
-
62
-
-
0742319175
-
Effects of Ni and Mo on the microstructure and some other properties of Co-Cr dental alloys
-
Matkovic T., Matkovic P., Malina J. Effects of Ni and Mo on the microstructure and some other properties of Co-Cr dental alloys. J Alloys Compd 2004, 366:293-297.
-
(2004)
J Alloys Compd
, vol.366
, pp. 293-297
-
-
Matkovic, T.1
Matkovic, P.2
Malina, J.3
-
63
-
-
0032605637
-
A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements
-
Dearnley P.A. A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements. Proc Inst Mech Eng Part H: J Eng Med 1999, 213:107-135.
-
(1999)
Proc Inst Mech Eng Part H: J Eng Med
, vol.213
, pp. 107-135
-
-
Dearnley, P.A.1
-
64
-
-
33645767941
-
Metal ion release from nitrogen ion implanted CoCrMo orthopedic implant material
-
Öztürk O., Türkan U., Eroglu A.E. Metal ion release from nitrogen ion implanted CoCrMo orthopedic implant material. Surf Coat Technol 2006, 200:5687-5697.
-
(2006)
Surf Coat Technol
, vol.200
, pp. 5687-5697
-
-
Öztürk, O.1
Türkan, U.2
Eroglu, A.E.3
-
65
-
-
0035882642
-
Examination of in vivo influences on bioluminescent microbial assessment of corrosion product toxicity
-
Shettlemore M.G., Bundy K.J. Examination of in vivo influences on bioluminescent microbial assessment of corrosion product toxicity. Biomaterials 2001, 22:2215-2228.
-
(2001)
Biomaterials
, vol.22
, pp. 2215-2228
-
-
Shettlemore, M.G.1
Bundy, K.J.2
-
66
-
-
3042786380
-
Cobalt-based alloys for orthopaedic applications studied by electrochemical and XPS analysis
-
Kocijan A., MiloÅev I., Pihlar B. Cobalt-based alloys for orthopaedic applications studied by electrochemical and XPS analysis. J Mater Sci - Mater Med 2004, 15:643-650.
-
(2004)
J Mater Sci - Mater Med
, vol.15
, pp. 643-650
-
-
Kocijan, A.1
MiloÅev, I.2
Pihlar, B.3
-
67
-
-
20444396175
-
The design and production of Co-Cr alloy implants with controlled surface topography by CAD-CAM method and their effects on osseointegration
-
Hunt J.A., Callaghan J.T., Sutcliffe C.J., Morgan R.H., Halford B., Black R.A. The design and production of Co-Cr alloy implants with controlled surface topography by CAD-CAM method and their effects on osseointegration. Biomaterials 2005, 26:5890-5897.
-
(2005)
Biomaterials
, vol.26
, pp. 5890-5897
-
-
Hunt, J.A.1
Callaghan, J.T.2
Sutcliffe, C.J.3
Morgan, R.H.4
Halford, B.5
Black, R.A.6
-
68
-
-
79954449535
-
Improved adhesion of ultra-hard carbon films on cobalt-chromium orthopaedic implant alloy
-
Catledge S.A., Vaid R., Diggins Iv P., Weimer J.J., Koopman M., Vohra Y.K. Improved adhesion of ultra-hard carbon films on cobalt-chromium orthopaedic implant alloy. J Mater Sci: Mater Med 2011, 22:307-316.
-
(2011)
J Mater Sci: Mater Med
, vol.22
, pp. 307-316
-
-
Catledge, S.A.1
Vaid, R.2
Diggins Iv, P.3
Weimer, J.J.4
Koopman, M.5
Vohra, Y.K.6
-
69
-
-
84856467933
-
Microstructure and tribological characteristics of aged Co-28Cr-Mo-0.3C alloy
-
Zangeneh S., Lashgari H.R., Roshani A. Microstructure and tribological characteristics of aged Co-28Cr-Mo-0.3C alloy. Mater Des 2012, 37:292-303.
-
(2012)
Mater Des
, vol.37
, pp. 292-303
-
-
Zangeneh, S.1
Lashgari, H.R.2
Roshani, A.3
-
70
-
-
58649109179
-
Characterization of novel borides in Ti-Nb-Zr-Ta-2B metal-matrix composites
-
Nag S., Samuel S., Puthucode A., Banerjee R. Characterization of novel borides in Ti-Nb-Zr-Ta-2B metal-matrix composites. Mater Charact 2009, 60:106-113.
-
(2009)
Mater Charact
, vol.60
, pp. 106-113
-
-
Nag, S.1
Samuel, S.2
Puthucode, A.3
Banerjee, R.4
-
71
-
-
0025642529
-
Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces: a human retrieval analysis
-
Nasser S.A.M., Campbell P.A.T.A., Kilgus D., Kossovsky N.I.R., Amstutz H.C. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces: a human retrieval analysis. Clin Orthop Relat Res 1990, 261:171.
-
(1990)
Clin Orthop Relat Res
, vol.261
, pp. 171
-
-
Nasser, S.A.M.1
Campbell, P.A.T.A.2
Kilgus, D.3
Kossovsky, N.I.R.4
Amstutz, H.C.5
-
72
-
-
0019850049
-
The influence of titanium surface treatments on the wear of medical grade polyethylene
-
Rostoker W., Galante J.O. The influence of titanium surface treatments on the wear of medical grade polyethylene. Biomaterials 1981, 2:221.
-
(1981)
Biomaterials
, vol.2
, pp. 221
-
-
Rostoker, W.1
Galante, J.O.2
-
73
-
-
49949095955
-
Biomaterials in orthopaedics
-
Navarro M., Michiardi A., Castao O., Planell J.A. Biomaterials in orthopaedics. J Roy Soc Interface 2008, 5:1137-1158.
-
(2008)
J Roy Soc Interface
, vol.5
, pp. 1137-1158
-
-
Navarro, M.1
Michiardi, A.2
Castao, O.3
Planell, J.A.4
-
74
-
-
84875686716
-
Ti based biomaterials, the ultimate choice for orthopaedic implants - a review
-
Geetha M., Singh A.K., Asokamani R., Gogia A.K. Ti based biomaterials, the ultimate choice for orthopaedic implants - a review. Prog Mater Sci 2008, 54:397-425.
-
(2008)
Prog Mater Sci
, vol.54
, pp. 397-425
-
-
Geetha, M.1
Singh, A.K.2
Asokamani, R.3
Gogia, A.K.4
-
75
-
-
2942613210
-
Comparison of metal release from various metallic biomaterials in vitro
-
Okazaki Y., Gotoh E. Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 2005, 26:11-21.
-
(2005)
Biomaterials
, vol.26
, pp. 11-21
-
-
Okazaki, Y.1
Gotoh, E.2
-
76
-
-
80051502285
-
Alloy design and property evaluation of new Ti-Cr-Nb alloys
-
Slokar L., Matkovic T., Matkovic P. Alloy design and property evaluation of new Ti-Cr-Nb alloys. Mater Des 2012, 33:26-30.
-
(2012)
Mater Des
, vol.33
, pp. 26-30
-
-
Slokar, L.1
Matkovic, T.2
Matkovic, P.3
-
77
-
-
84903320821
-
Titanium nitride coatings on Ti alloys by PIRAC for orthopedic implants Key Engineering Materials
-
Wu S., Gutmanas E.Y., Gotman I. Titanium nitride coatings on Ti alloys by PIRAC for orthopedic implants Key Engineering Materials. Harbin 2010, 23:481-484.
-
(2010)
Harbin
, vol.23
, pp. 481-484
-
-
Wu, S.1
Gutmanas, E.Y.2
Gotman, I.3
-
78
-
-
35548990650
-
Novel technique for preparing Ca- and P-containing ceramic coating on Ti-6Al-4V by micro-arc oxidation
-
Yu S., Yang X., Yang L., Liu Y., Yu Y. Novel technique for preparing Ca- and P-containing ceramic coating on Ti-6Al-4V by micro-arc oxidation. J Biomed Mater Res - Part B Appl Biomater 2007, 83:623-627.
-
(2007)
J Biomed Mater Res - Part B Appl Biomater
, vol.83
, pp. 623-627
-
-
Yu, S.1
Yang, X.2
Yang, L.3
Liu, Y.4
Yu, Y.5
-
79
-
-
56249105409
-
Effect of surface structure on biomechanical properties and osseointegration
-
Lee B.H., Lee C., Kim D.G., Choi K., Lee K.H., Kim Y.D. Effect of surface structure on biomechanical properties and osseointegration. Mater Sci Eng, C 2008, 28:1448-1461.
-
(2008)
Mater Sci Eng, C
, vol.28
, pp. 1448-1461
-
-
Lee, B.H.1
Lee, C.2
Kim, D.G.3
Choi, K.4
Lee, K.H.5
Kim, Y.D.6
-
81
-
-
0000689059
-
Recent metallic materials for biomedical applications
-
Niinomi M. Recent metallic materials for biomedical applications. Metall Mater Trans A 2002, 33:477-486.
-
(2002)
Metall Mater Trans A
, vol.33
, pp. 477-486
-
-
Niinomi, M.1
-
82
-
-
0032170254
-
Titanium alloys in total joint replacement-a materials science perspective
-
Long M., Rack H.J. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials 1998, 19:1621-1639.
-
(1998)
Biomaterials
, vol.19
, pp. 1621-1639
-
-
Long, M.1
Rack, H.J.2
-
84
-
-
33746958974
-
Theoretical investigation of wear-resistance mechanism of superelastic shape memory alloy NiTi
-
Yan W. Theoretical investigation of wear-resistance mechanism of superelastic shape memory alloy NiTi. Mater Sci Eng, A 2006, 427:348-355.
-
(2006)
Mater Sci Eng, A
, vol.427
, pp. 348-355
-
-
Yan, W.1
-
85
-
-
67649410126
-
Tribological behavior of NiTi alloy in martensitic and austenitic states
-
Abedini M., Ghasemi H.M., Nili Ahmadabadi M. Tribological behavior of NiTi alloy in martensitic and austenitic states. Mater Des 2009, 30:4493-4497.
-
(2009)
Mater Des
, vol.30
, pp. 4493-4497
-
-
Abedini, M.1
Ghasemi, H.M.2
Nili Ahmadabadi, M.3
-
86
-
-
0030270078
-
Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing
-
Berger-Gorbet M., Broxup B., Rivard C., Yahia L.H. Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing. J Biomed Mater Res 1996, 32:243-248.
-
(1996)
J Biomed Mater Res
, vol.32
, pp. 243-248
-
-
Berger-Gorbet, M.1
Broxup, B.2
Rivard, C.3
Yahia, L.H.4
-
87
-
-
2442447286
-
Bioactive NiTi shape memory alloy used as bone bonding implants
-
Chen M.F., Yang X.J., Hu R.X., Cui Z.D., Man H.C. Bioactive NiTi shape memory alloy used as bone bonding implants. Mater Sci Eng, C 2004, 24:497-502.
-
(2004)
Mater Sci Eng, C
, vol.24
, pp. 497-502
-
-
Chen, M.F.1
Yang, X.J.2
Hu, R.X.3
Cui, Z.D.4
Man, H.C.5
-
88
-
-
0016993584
-
Biocompatibility of nitinol alloy as an implant material
-
Castleman L.S., Motzkin S.M., Alicandri F.P., Bonawit V.L. Biocompatibility of nitinol alloy as an implant material. J Biomed Mater Res 1976, 10:695-731.
-
(1976)
J Biomed Mater Res
, vol.10
, pp. 695-731
-
-
Castleman, L.S.1
Motzkin, S.M.2
Alicandri, F.P.3
Bonawit, V.L.4
-
89
-
-
0032487124
-
In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness
-
Ryhaenen J., Kallioinen M., Tuukkanen J., Junila J., Niemelae E., Sandvik P., et al. In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness. J Biomed Mater Res 1998, 41:481-488.
-
(1998)
J Biomed Mater Res
, vol.41
, pp. 481-488
-
-
Ryhaenen, J.1
Kallioinen, M.2
Tuukkanen, J.3
Junila, J.4
Niemelae, E.5
Sandvik, P.6
-
90
-
-
0034901371
-
Effect of nickel-titanium shape memory metal alloy on bone formation
-
Kapanen A., Ryhanen J., Danilov A., Tuukkanen J. Effect of nickel-titanium shape memory metal alloy on bone formation. Biomaterials 2001, 22:2475-2480.
-
(2001)
Biomaterials
, vol.22
, pp. 2475-2480
-
-
Kapanen, A.1
Ryhanen, J.2
Danilov, A.3
Tuukkanen, J.4
-
91
-
-
0030340747
-
On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
-
Shabalovskaya S.A. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys. Bio-Med Mater Eng 1996, 6:267-289.
-
(1996)
Bio-Med Mater Eng
, vol.6
, pp. 267-289
-
-
Shabalovskaya, S.A.1
-
93
-
-
15044364236
-
Assessing the biocompatibility of NiTi shape memory alloys used for medical applications
-
Es-Souni M., Fischer-Brandies H. Assessing the biocompatibility of NiTi shape memory alloys used for medical applications. Anal Bioanal Chem 2005, 381:557-567.
-
(2005)
Anal Bioanal Chem
, vol.381
, pp. 557-567
-
-
Es-Souni, M.1
Fischer-Brandies, H.2
-
94
-
-
33847051969
-
Electrochemical behaviour of oxidized NiTi shape memory alloys for biomedical applications
-
Michiardi A., Aparicio C., Planell J.A., Gil F.J. Electrochemical behaviour of oxidized NiTi shape memory alloys for biomedical applications. Surf Coat Technol 2007, 201:6484-6488.
-
(2007)
Surf Coat Technol
, vol.201
, pp. 6484-6488
-
-
Michiardi, A.1
Aparicio, C.2
Planell, J.A.3
Gil, F.J.4
-
96
-
-
78651074480
-
(Ti, O)/Ti and (Ti, O, N)/Ti composite coatings fabricated via PIIID for the medical application of NiTi shape memory alloy
-
Sun T., Wang L.P., Wang M. (Ti, O)/Ti and (Ti, O, N)/Ti composite coatings fabricated via PIIID for the medical application of NiTi shape memory alloy. J Biomed Mater Res - Part B Appl Biomater 2011, 96B:249-260.
-
(2011)
J Biomed Mater Res - Part B Appl Biomater
, vol.96 B
, pp. 249-260
-
-
Sun, T.1
Wang, L.P.2
Wang, M.3
-
97
-
-
67349159344
-
Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy
-
Chu C.L., Guo C., Sheng X.B., Dong Y.S., Lin P.H., Yeung K.W.K., et al. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy. Acta Biomater 2009, 5:2238-2245.
-
(2009)
Acta Biomater
, vol.5
, pp. 2238-2245
-
-
Chu, C.L.1
Guo, C.2
Sheng, X.B.3
Dong, Y.S.4
Lin, P.H.5
Yeung, K.W.K.6
-
98
-
-
80051876620
-
Finite element analysis of the effect of shape memory alloy on the stress distribution and contact pressure in total knee replacement
-
Bahraminasab M., Sahari B.B., Hassan M.R., Arumugam M. Finite element analysis of the effect of shape memory alloy on the stress distribution and contact pressure in total knee replacement. Trends Biomater Artif Organs 2011, 25:95-100.
-
(2011)
Trends Biomater Artif Organs
, vol.25
, pp. 95-100
-
-
Bahraminasab, M.1
Sahari, B.B.2
Hassan, M.R.3
Arumugam, M.4
-
99
-
-
37349093638
-
Mechanical properties of nickel-titanium foams for reconstructive orthopaedics
-
Barrabes M., Sevilla P., Planell J.A., Gil F.J. Mechanical properties of nickel-titanium foams for reconstructive orthopaedics. Mater Sci Eng, C 2008, 28:23-27.
-
(2008)
Mater Sci Eng, C
, vol.28
, pp. 23-27
-
-
Barrabes, M.1
Sevilla, P.2
Planell, J.A.3
Gil, F.J.4
-
100
-
-
75049084111
-
Application of Laser Engineered Net Shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants
-
Bandyopadhyay A., Krishna B.V., Xue W., Bose S. Application of Laser Engineered Net Shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants. J Mater Sci - Mater Med 2009, 20:29-34.
-
(2009)
J Mater Sci - Mater Med
, vol.20
, pp. 29-34
-
-
Bandyopadhyay, A.1
Krishna, B.V.2
Xue, W.3
Bose, S.4
-
101
-
-
56249083131
-
Effect of porous NiTi alloy on bone formation: a comparative investigation with bulk NiTi alloy for 15weeks in vivo
-
Zhu S.L., Yang X.J., Chen M.F., Li C.Y., Cui Z.D. Effect of porous NiTi alloy on bone formation: a comparative investigation with bulk NiTi alloy for 15weeks in vivo. Mater Sci Eng, C 2008, 28:1271-1275.
-
(2008)
Mater Sci Eng, C
, vol.28
, pp. 1271-1275
-
-
Zhu, S.L.1
Yang, X.J.2
Chen, M.F.3
Li, C.Y.4
Cui, Z.D.5
-
102
-
-
44549083121
-
Porous NiTi for bone implants: a review
-
Bansiddhi A., Sargeant T.D., Stupp S.I., Dunand D.C. Porous NiTi for bone implants: a review. Acta Biomater 2008, 4:773-782.
-
(2008)
Acta Biomater
, vol.4
, pp. 773-782
-
-
Bansiddhi, A.1
Sargeant, T.D.2
Stupp, S.I.3
Dunand, D.C.4
-
103
-
-
20444426490
-
Morphological characterization and in vitro biocompatibility of a porous nickel-titanium alloy
-
Prymak O., Bogdanski D., Köller M., Esenwein S.A., Muhr G., Beckmann F., et al. Morphological characterization and in vitro biocompatibility of a porous nickel-titanium alloy. Biomaterials 2005, 26:5801-5807.
-
(2005)
Biomaterials
, vol.26
, pp. 5801-5807
-
-
Prymak, O.1
Bogdanski, D.2
Köller, M.3
Esenwein, S.A.4
Muhr, G.5
Beckmann, F.6
-
104
-
-
0028410987
-
Mechanical properties and shape memory of porous nitinol
-
Itin V.I., Gyunter V.E., Shabalovskaya S.A., Sachdeva R.L.C. Mechanical properties and shape memory of porous nitinol. Mater Charact 1994, 32:179-187.
-
(1994)
Mater Charact
, vol.32
, pp. 179-187
-
-
Itin, V.I.1
Gyunter, V.E.2
Shabalovskaya, S.A.3
Sachdeva, R.L.C.4
-
105
-
-
0036013823
-
Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model
-
Thierry B., Merhi Y., Bilodeau L., Trepanier C., Tabrizian M. Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model. Biomaterials 2002, 23:2997-3005.
-
(2002)
Biomaterials
, vol.23
, pp. 2997-3005
-
-
Thierry, B.1
Merhi, Y.2
Bilodeau, L.3
Trepanier, C.4
Tabrizian, M.5
-
106
-
-
33846512167
-
Oxygen plasma treatment to restrain nickel out-diffusion from porous nickel titanium orthopedic materials
-
Ho J.P.Y., Wu S.L., Poon R.W.Y., Chung C.Y., Tjong S.C., Chu P.K., et al. Oxygen plasma treatment to restrain nickel out-diffusion from porous nickel titanium orthopedic materials. Surf Coat Technol 2007, 201:4893-4896.
-
(2007)
Surf Coat Technol
, vol.201
, pp. 4893-4896
-
-
Ho, J.P.Y.1
Wu, S.L.2
Poon, R.W.Y.3
Chung, C.Y.4
Tjong, S.C.5
Chu, P.K.6
-
107
-
-
80255132964
-
Remarkable biocompatibility enhancement of porous NiTi alloys by a new surface modification approach: in-situ nitriding and in vitro and in vivo evaluation
-
Li H., Yuan B., Gao Y., Chung C.Y., Zhu M. Remarkable biocompatibility enhancement of porous NiTi alloys by a new surface modification approach: in-situ nitriding and in vitro and in vivo evaluation. J Biomed Mater Res - Part A 2011, 99A:544-553.
-
(2011)
J Biomed Mater Res - Part A
, vol.99 A
, pp. 544-553
-
-
Li, H.1
Yuan, B.2
Gao, Y.3
Chung, C.Y.4
Zhu, M.5
-
108
-
-
79952282923
-
Synthesis and characterization of sol gel hydroxyapatite coatings deposited on porous NiTi alloys
-
Zhang J.X., Guan R.F., Zhang X.P. Synthesis and characterization of sol gel hydroxyapatite coatings deposited on porous NiTi alloys. J Alloys Compd 2011, 509:4643-4648.
-
(2011)
J Alloys Compd
, vol.509
, pp. 4643-4648
-
-
Zhang, J.X.1
Guan, R.F.2
Zhang, X.P.3
-
109
-
-
0018761665
-
Nickel sensitivity in the general population
-
Peltonen L. Nickel sensitivity in the general population. Contact Dermatitis 1979, 5:27-32.
-
(1979)
Contact Dermatitis
, vol.5
, pp. 27-32
-
-
Peltonen, L.1
-
110
-
-
33845372992
-
Ceramic materials in total joint arthroplasty
-
Bal B.S., Garino J., Ries M., Rahaman M.N. Ceramic materials in total joint arthroplasty. Semin Arthroplasty 2006, 17:94-101.
-
(2006)
Semin Arthroplasty
, vol.17
, pp. 94-101
-
-
Bal, B.S.1
Garino, J.2
Ries, M.3
Rahaman, M.N.4
-
111
-
-
0036913829
-
Ceramic-on-ceramic bearings in total hip arthroplasty
-
Bierbaum B.E., Nairus J., Kuesis D., Morrison J.C., Ward D. Ceramic-on-ceramic bearings in total hip arthroplasty. Clin Orthop Relat Res 2002, 405:158-163.
-
(2002)
Clin Orthop Relat Res
, vol.405
, pp. 158-163
-
-
Bierbaum, B.E.1
Nairus, J.2
Kuesis, D.3
Morrison, J.C.4
Ward, D.5
-
112
-
-
84903350103
-
Ceramic femoral prosthesis in TKA-present and future bioceramics and alternative bearings in joint arthroplasty
-
Chang J.-D., Billau K., Lee M.-C., Ahn J.W. Ceramic femoral prosthesis in TKA-present and future bioceramics and alternative bearings in joint arthroplasty. Steinkopff 2007, 123-132.
-
(2007)
Steinkopff
, pp. 123-132
-
-
Chang, J.-D.1
Billau, K.2
Lee, M.-C.3
Ahn, J.W.4
-
113
-
-
33845359377
-
The use of a ceramic surfaced oxinium™ implant in total knee replacement
-
Laskin R.S. The use of a ceramic surfaced oxinium™ implant in total knee replacement. Tech Knee Surg 2004, 3:187-192.
-
(2004)
Tech Knee Surg
, vol.3
, pp. 187-192
-
-
Laskin, R.S.1
-
115
-
-
33750363656
-
Hip implants - paper VI - ion concentrations
-
Sargeant A., Goswami T. Hip implants - paper VI - ion concentrations. Mater Des 2007, 28:155-171.
-
(2007)
Mater Des
, vol.28
, pp. 155-171
-
-
Sargeant, A.1
Goswami, T.2
-
117
-
-
11844255625
-
Ceramics in total hip replacement
-
Hannouche D., Hamadouche M., Nizard R., Bizot P., Meunier A., Sedel L. Ceramics in total hip replacement. Clin Orthop Relat Res 2005, 430:62-71.
-
(2005)
Clin Orthop Relat Res
, vol.430
, pp. 62-71
-
-
Hannouche, D.1
Hamadouche, M.2
Nizard, R.3
Bizot, P.4
Meunier, A.5
Sedel, L.6
-
118
-
-
0018348212
-
Tissue reaction to ceramic implant material
-
Harms J., Mausle E. Tissue reaction to ceramic implant material. J Biomed Mater Res 1979, 13:67-87.
-
(1979)
J Biomed Mater Res
, vol.13
, pp. 67-87
-
-
Harms, J.1
Mausle, E.2
-
119
-
-
0015233325
-
Alumina and its use in surgery of the hip (Experimental study)
-
Boutin P. Alumina and its use in surgery of the hip (Experimental study). La Presse Méd 1971, 79:639-640.
-
(1971)
La Presse Méd
, vol.79
, pp. 639-640
-
-
Boutin, P.1
-
120
-
-
62349114287
-
PE wear in ceramic/PE bearing surface in total knee arthroplasty: clinical experiences of more than 24years
-
Oonishi H., Kim S., Kyomoto M., Iwamoto M., Ueno M. PE wear in ceramic/PE bearing surface in total knee arthroplasty: clinical experiences of more than 24years. Bioceram Altern Bearings Joint Arthroplasty 2006, 101-110.
-
(2006)
Bioceram Altern Bearings Joint Arthroplasty
, pp. 101-110
-
-
Oonishi, H.1
Kim, S.2
Kyomoto, M.3
Iwamoto, M.4
Ueno, M.5
-
121
-
-
0017513553
-
New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramic/metal
-
Semlitsch M., Lehmann M., Weber H. New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramic/metal. J Biomed Mater Res 1977, 11:537-552.
-
(1977)
J Biomed Mater Res
, vol.11
, pp. 537-552
-
-
Semlitsch, M.1
Lehmann, M.2
Weber, H.3
-
122
-
-
0036167153
-
Surface analysis on retrieved ceramic total knee prosthesis
-
Palm Springs, CA, S. Brown, I. Clarke, P. Williams (Eds.)
-
Oonishi H., Fujita H., Itoh S., Kin S., Amino H., Tsuji E. Surface analysis on retrieved ceramic total knee prosthesis. Key engineering materials 2002, 499-502. Palm Springs, CA. S. Brown, I. Clarke, P. Williams (Eds.).
-
(2002)
Key engineering materials
, pp. 499-502
-
-
Oonishi, H.1
Fujita, H.2
Itoh, S.3
Kin, S.4
Amino, H.5
Tsuji, E.6
-
123
-
-
0036166729
-
Development and improvement of ceramic TKP for 19years and clinical results
-
Palm Springs, CA, S. Brown, I. Clarke, P. Williams (Eds.)
-
Oonishi H., Fujita H., Itoh S., Kin S., Amino H. Development and improvement of ceramic TKP for 19years and clinical results. Key engineering materials 2002, 479-482. Palm Springs, CA. S. Brown, I. Clarke, P. Williams (Eds.).
-
(2002)
Key engineering materials
, pp. 479-482
-
-
Oonishi, H.1
Fujita, H.2
Itoh, S.3
Kin, S.4
Amino, H.5
-
124
-
-
0035151489
-
3 to 18year clinical results of total knee replacement with ceramic components
-
Oonishi H., Murata N., Saito M., Wakitani S., Imoto K., Kin S., et al. 3 to 18year clinical results of total knee replacement with ceramic components. Key Eng Mater 2001, 192-195:999-1002.
-
(2001)
Key Eng Mater
, pp. 999-1002
-
-
Oonishi, H.1
Murata, N.2
Saito, M.3
Wakitani, S.4
Imoto, K.5
Kin, S.6
-
125
-
-
0024255826
-
The use of dense alumina-alumina ceramic combination in total hip replacement
-
Boutin P., Christel P., Dorlot J.M., Meunier A., De Roquancourt A., Blanquaert D., et al. The use of dense alumina-alumina ceramic combination in total hip replacement. J Biomed Mater Res 1988, 22:1203-1232.
-
(1988)
J Biomed Mater Res
, vol.22
, pp. 1203-1232
-
-
Boutin, P.1
Christel, P.2
Dorlot, J.M.3
Meunier, A.4
De Roquancourt, A.5
Blanquaert, D.6
-
126
-
-
0345491958
-
Fractures of ceramic bearings: history and present status
-
Hannouche D., Nich C., Bizot P., Meunier A., Nizard R., Sedel L. Fractures of ceramic bearings: history and present status. Clin Orthop Relat Res 2003, 19-26.
-
(2003)
Clin Orthop Relat Res
, pp. 19-26
-
-
Hannouche, D.1
Nich, C.2
Bizot, P.3
Meunier, A.4
Nizard, R.5
Sedel, L.6
-
127
-
-
39049171221
-
Clinical results of posterior cruciate ligament retaining TKA with alumina ceramic condylar prosthesis: comparison to Co-Cr alloy prosthesis
-
Majima T., Yasuda K., Tago H., Aoki Y., Minami A. Clinical results of posterior cruciate ligament retaining TKA with alumina ceramic condylar prosthesis: comparison to Co-Cr alloy prosthesis. Knee Surg Sports Traumatol Arthrosc 2008, 16:152-156.
-
(2008)
Knee Surg Sports Traumatol Arthrosc
, vol.16
, pp. 152-156
-
-
Majima, T.1
Yasuda, K.2
Tago, H.3
Aoki, Y.4
Minami, A.5
-
128
-
-
10744222195
-
Current status of zirconia used in total hip implants
-
Clarke I.C., Manaka M., Green D.D., Williams P., Pezzotti G., Kim Y.H., et al. Current status of zirconia used in total hip implants. J Bone Joint Surg - Ser A 2003, 85:73-84.
-
(2003)
J Bone Joint Surg - Ser A
, vol.85
, pp. 73-84
-
-
Clarke, I.C.1
Manaka, M.2
Green, D.D.3
Williams, P.4
Pezzotti, G.5
Kim, Y.H.6
-
129
-
-
33744999193
-
Primary TKA with a zirconia ceramic femoral component
-
Bal B.S., Greenberg D.D., Buhrmester L., Aleto T.J. Primary TKA with a zirconia ceramic femoral component. J Knee Surg 2006, 19:89-93.
-
(2006)
J Knee Surg
, vol.19
, pp. 89-93
-
-
Bal, B.S.1
Greenberg, D.D.2
Buhrmester, L.3
Aleto, T.J.4
-
132
-
-
84985142539
-
Crystalline phase change in yttria partially stabilized zirconia by low temperature annealing
-
Sato T., Shimada M. Crystalline phase change in yttria partially stabilized zirconia by low temperature annealing. J Am Ceram Soc 1984, 67:C212-C213.
-
(1984)
J Am Ceram Soc
, vol.67
-
-
Sato, T.1
Shimada, M.2
-
133
-
-
0022077265
-
2 polycrystals by annealing in water
-
2 polycrystals by annealing in water. J Am Ceram Soc 1985, 68:356.
-
(1985)
J Am Ceram Soc
, vol.68
, pp. 356
-
-
Sato, T.1
Shimada, M.2
-
134
-
-
33845366576
-
Oxidized zirconium in total joint arthroplasty
-
Ries M.D. Oxidized zirconium in total joint arthroplasty. Semin Arthroplasty 2006, 17:161-164.
-
(2006)
Semin Arthroplasty
, vol.17
, pp. 161-164
-
-
Ries, M.D.1
-
135
-
-
0035144270
-
2 fraction on the wear of ceramic on ceramic hip joint prostheses. A long-term in vitro wear study
-
2 fraction on the wear of ceramic on ceramic hip joint prostheses. A long-term in vitro wear study. Biomaterials 2001, 22:717-723.
-
(2001)
Biomaterials
, vol.22
, pp. 717-723
-
-
Affatato, S.1
Goldoni, M.2
Testoni, M.3
Toni, A.4
-
138
-
-
0025124253
-
Mechanical behaviour of zirconia and zirconia-toughened alumina in a simulated body environment
-
Thompson I., Rawlings R. Mechanical behaviour of zirconia and zirconia-toughened alumina in a simulated body environment. Biomaterials 1990, 11:505-508.
-
(1990)
Biomaterials
, vol.11
, pp. 505-508
-
-
Thompson, I.1
Rawlings, R.2
-
139
-
-
74849138632
-
In vitro and in vivo evaluation of an alumina-zirconia composite for arthroplasty applications
-
Roualdes O., Duclos M.E., Gutknecht D., Frappart L., Chevalier J., Hartmann D.J. In vitro and in vivo evaluation of an alumina-zirconia composite for arthroplasty applications. Biomaterials 2010, 31:2043-2054.
-
(2010)
Biomaterials
, vol.31
, pp. 2043-2054
-
-
Roualdes, O.1
Duclos, M.E.2
Gutknecht, D.3
Frappart, L.4
Chevalier, J.5
Hartmann, D.J.6
-
140
-
-
0343773951
-
Biocompatibility of a new alumina matrix biocomposite AMC
-
Willmann G., Von Chamier W., Pfaff H.G., Rack R. Biocompatibility of a new alumina matrix biocomposite AMC. Key Eng Mater 2000, 192:569-574.
-
(2000)
Key Eng Mater
, vol.192
, pp. 569-574
-
-
Willmann, G.1
Von Chamier, W.2
Pfaff, H.G.3
Rack, R.4
-
141
-
-
84865334583
-
-
A new ceramic material for orthopaedics 5th international CeramTec symposium Plochingen, Germany
-
Rack R, Pfaff HG. A new ceramic material for orthopaedics 5th international CeramTec symposium Plochingen, Germany; 2000. p. 141-5.
-
(2000)
, pp. 141-5
-
-
Rack, R.1
Pfaff, H.G.2
-
142
-
-
0242606961
-
Reduced wear with oxidized zirconium femoral heads
-
Good V., Ries M., Barrack R., Widding K., Hunter G., Heuer D. Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg Am 2003, 85:105-110.
-
(2003)
J Bone Joint Surg Am
, vol.85
, pp. 105-110
-
-
Good, V.1
Ries, M.2
Barrack, R.3
Widding, K.4
Hunter, G.5
Heuer, D.6
-
143
-
-
21944457757
-
Creation of oxidized zirconium orthopaedic implants
-
Hunter G., Dickinson J., Herb B., Graham R. Creation of oxidized zirconium orthopaedic implants. J ASTM Int 2005, 2:409-422.
-
(2005)
J ASTM Int
, vol.2
, pp. 409-422
-
-
Hunter, G.1
Dickinson, J.2
Herb, B.3
Graham, R.4
-
144
-
-
0027244880
-
Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear
-
Davidson J.A. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. Clin Orthop Relat Res 1993, 294:361.
-
(1993)
Clin Orthop Relat Res
, vol.294
, pp. 361
-
-
Davidson, J.A.1
-
145
-
-
2942571690
-
Alternative femoral bearing surface options for knee replacement in young patients
-
Hernigou P., Nogier A., Manicom O., Poignard A., De Abreu L., Filippini P. Alternative femoral bearing surface options for knee replacement in young patients. Knee 2004, 11:169-172.
-
(2004)
Knee
, vol.11
, pp. 169-172
-
-
Hernigou, P.1
Nogier, A.2
Manicom, O.3
Poignard, A.4
De Abreu, L.5
Filippini, P.6
-
146
-
-
21944433384
-
Mechanical behavior of zirconia, alumina, and oxidized zirconium modular heads
-
Sprague J., Salehi A., Tsai S., Pawar V., Thomas R., Hunter G. Mechanical behavior of zirconia, alumina, and oxidized zirconium modular heads. Int Soc Technol Arthoplasty 2003, 23:31-36.
-
(2003)
Int Soc Technol Arthoplasty
, vol.23
, pp. 31-36
-
-
Sprague, J.1
Salehi, A.2
Tsai, S.3
Pawar, V.4
Thomas, R.5
Hunter, G.6
-
147
-
-
77953287397
-
The 5-year results of an oxidized zirconium femoral component for TKA
-
Innocenti M., Civinini R., Carulli C., Matassi F., Villano M. The 5-year results of an oxidized zirconium femoral component for TKA. Clin Orthopaed Relat Res® 2010, 468:1258-1263.
-
(2010)
Clin Orthopaed Relat Res®
, vol.468
, pp. 1258-1263
-
-
Innocenti, M.1
Civinini, R.2
Carulli, C.3
Matassi, F.4
Villano, M.5
-
148
-
-
0028594009
-
Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components
-
White S.E., Whiteside L.A., McCarthy D.S., Anthony M., Poggie R.A. Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components. Clin Orthop Relat Res 1994, 309:176.
-
(1994)
Clin Orthop Relat Res
, vol.309
, pp. 176
-
-
White, S.E.1
Whiteside, L.A.2
McCarthy, D.S.3
Anthony, M.4
Poggie, R.A.5
-
149
-
-
37349075791
-
The use of a ceramic surfaced oxidized zirconium implant in total knee replacement
-
Laskin R.S. The use of a ceramic surfaced oxidized zirconium implant in total knee replacement. Tech Knee Surg 2007, 6:220-226.
-
(2007)
Tech Knee Surg
, vol.6
, pp. 220-226
-
-
Laskin, R.S.1
-
150
-
-
0035175965
-
Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components
-
Spector B., Ries M.D., Bourne R.B., Sauer W.S., Long M., Hunter G. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J Bone Joint Surg Am 2001, 83:80-86.
-
(2001)
J Bone Joint Surg Am
, vol.83
, pp. 80-86
-
-
Spector, B.1
Ries, M.D.2
Bourne, R.B.3
Sauer, W.S.4
Long, M.5
Hunter, G.6
-
151
-
-
0031106697
-
Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplasty
-
Patel A., Spector M. Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplasty. Biomaterials 1997, 18:441-447.
-
(1997)
Biomaterials
, vol.18
, pp. 441-447
-
-
Patel, A.1
Spector, M.2
-
152
-
-
36348971818
-
UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation
-
DesJardins J.D., Burnikel B., LaBerge M. UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation. Wear 2008, 264:245-256.
-
(2008)
Wear
, vol.264
, pp. 245-256
-
-
DesJardins, J.D.1
Burnikel, B.2
LaBerge, M.3
-
153
-
-
33846528442
-
Structure and bioactivity of micro-arc oxidized zirconia films
-
Yan Y., Han Y. Structure and bioactivity of micro-arc oxidized zirconia films. Surf Coat Technol 2007, 201:5692-5695.
-
(2007)
Surf Coat Technol
, vol.201
, pp. 5692-5695
-
-
Yan, Y.1
Han, Y.2
-
154
-
-
0031838759
-
Can a total knee replacement prosthesis be made entirely of polymers?
-
Moore D.J., Freeman M.A.R., Revell P.A., Bradley G.W., Tuke M. Can a total knee replacement prosthesis be made entirely of polymers?. J Arthroplasty 1998, 13:388-395.
-
(1998)
J Arthroplasty
, vol.13
, pp. 388-395
-
-
Moore, D.J.1
Freeman, M.A.R.2
Revell, P.A.3
Bradley, G.W.4
Tuke, M.5
-
155
-
-
0031995388
-
A designers' guide to engineering polymer technology
-
Edwards K.L. A designers' guide to engineering polymer technology. Mater Des 1998, 19:57-67.
-
(1998)
Mater Des
, vol.19
, pp. 57-67
-
-
Edwards, K.L.1
-
156
-
-
80255132041
-
Polyoxymethylene-homopolymer/hydroxyapatite nanocomposites for biomedical applications
-
Pielichowska K. Polyoxymethylene-homopolymer/hydroxyapatite nanocomposites for biomedical applications. J Appl Polym Sci 2012, 123:2234-2243.
-
(2012)
J Appl Polym Sci
, vol.123
, pp. 2234-2243
-
-
Pielichowska, K.1
-
157
-
-
0027486304
-
Evaluation of wear in an all-polymer total knee replacement. Part 1: Laboratory testing of polyethylene on polyacetal bearing surfaces
-
McKellop H.A., Rostlund T., Bradley G. Evaluation of wear in an all-polymer total knee replacement. Part 1: Laboratory testing of polyethylene on polyacetal bearing surfaces. Clin Mater 1993, 14:117-126.
-
(1993)
Clin Mater
, vol.14
, pp. 117-126
-
-
McKellop, H.A.1
Rostlund, T.2
Bradley, G.3
-
158
-
-
0027490729
-
Evaluation of wear in an all-polymer total knee replacement. Part 2: Clinical evaluation of wear in a polyethylene on polyacetal total knee
-
Bradley G.W., Freeman M.A.R., Tuke M.A., McKellop H.A. Evaluation of wear in an all-polymer total knee replacement. Part 2: Clinical evaluation of wear in a polyethylene on polyacetal total knee. Clin Mater 1993, 14:127-132.
-
(1993)
Clin Mater
, vol.14
, pp. 127-132
-
-
Bradley, G.W.1
Freeman, M.A.R.2
Tuke, M.A.3
McKellop, H.A.4
-
159
-
-
0035683955
-
Tensile mechanical properties of polyacetal after one and six months' immersion in Ringer's solution
-
Thompson M.S., Northmore-Ball M.D., Tanner K.E. Tensile mechanical properties of polyacetal after one and six months' immersion in Ringer's solution. J Mater Sci - Mater Med 2001, 12:883-887.
-
(2001)
J Mater Sci - Mater Med
, vol.12
, pp. 883-887
-
-
Thompson, M.S.1
Northmore-Ball, M.D.2
Tanner, K.E.3
-
160
-
-
80053414071
-
Bioactive polymer/hydroxyapatite (nano)composites for bone tissue regeneration.
-
In: Akihiro A, Dusek K, Kobayashi S, editors. Advances in Polymer Science
-
Pielichowska K, Blazewicz S. Bioactive polymer/hydroxyapatite (nano)composites for bone tissue regeneration. In: Akihiro A, Dusek K, Kobayashi S, editors. Advances in Polymer Science; 2010. p. 97-207.
-
(2010)
, pp. 97-207
-
-
Pielichowska, K.1
Blazewicz, S.2
-
161
-
-
84857002033
-
The influence of molecular weight on the properties of polyacetal/hydroxyapatite nanocomposites. Part 2: In vitro assessment
-
Pielichowska K. The influence of molecular weight on the properties of polyacetal/hydroxyapatite nanocomposites. Part 2: In vitro assessment. J Polym Res 2012, 19:1-10.
-
(2012)
J Polym Res
, vol.19
, pp. 1-10
-
-
Pielichowska, K.1
|