메뉴 건너뛰기




Volumn 14, Issue 3, 2012, Pages 483-496

An implantable MEMS micropump system for drug delivery in small animals

Author keywords

Drug delivery; Electrochemical bellows actuator; Implants; Micropump

Indexed keywords

ANTI-CANCER DRUG DELIVERY; CONSTANT CURRENT; DRUG RESERVOIR; FULLY INTEGRATED; GLASS SUBSTRATES; IMPLANTABLE DRUG DELIVERY; IMPLANTABLE DRUG DELIVERY SYSTEMS; IN-VIVO; MICRO PUMP; PARYLENES; SMALL ANIMAL;

EID: 84861460408     PISSN: 13872176     EISSN: 15728781     Source Type: Journal    
DOI: 10.1007/s10544-011-9625-4     Document Type: Article
Times cited : (133)

References (59)
  • 1
    • 84861457659 scopus 로고    scopus 로고
    • Alzet. ALZET® Osmotic Pumps-Implantable pumps for research.Available at: Accessed October 19
    • Alzet. ALZET® Osmotic Pumps-Implantable pumps for research. Available at: http://www.alzet.com/[Accessed October 19, 2011a]
    • (2011)
  • 3
    • 62249096225 scopus 로고    scopus 로고
    • Current micropump technologies and their biomedical applications
    • F. Amirouche, Y. Zhou, T. Johnson, Current micropump technologies and their biomedical applications. Microsyst Technol 15, 647-666 (2009)
    • (2009) Microsyst Technol , vol.15 , pp. 647-666
    • Amirouche, F.1    Zhou, Y.2    Johnson, T.3
  • 5
    • 0028445623 scopus 로고
    • Coplanar interdigitated band electrodes for synthesis Part I: Ohmic loss evaluation
    • C. Belmont, H.H. Girault, Coplanar interdigitated band electrodes for synthesis Part I: Ohmic loss evaluation. J Appl Electrochem 24, 475-480 (1994)
    • (1994) J Appl Electrochem , vol.24 , pp. 475-480
    • Belmont, C.1    Girault, H.H.2
  • 6
    • 67649878812 scopus 로고    scopus 로고
    • The rat as an animal model of Alzheimer's disease
    • E. Benedikz, E. Kloskowska, B. Winblad, The rat as an animal model of Alzheimer's disease. J Cell Mol Med 13, 1034-1042 (2009)
    • (2009) J Cell Mol Med , vol.13 , pp. 1034-1042
    • Benedikz, E.1    Kloskowska, E.2    Winblad, B.3
  • 7
    • 0000701749 scopus 로고    scopus 로고
    • An integrated micromachined electrochemical pump and dosing system
    • DOI 10.1023/A:1009996407848
    • S. Böhm, W. Olthuis, P. Bergveld, An integrated micromachined electrochemical pump and dosing system. Biomed Microdevices 1(2), 121-130 (1999) (Pubitemid 129645133)
    • (1999) Biomedical Microdevices , vol.1 , Issue.2 , pp. 121-130
    • Bohm, S.1    Olthuis, W.2    Bergveld, P.3
  • 8
    • 84861459936 scopus 로고    scopus 로고
    • Debiotech. Debiotech-Medical Devices-Switzerland. Available at:Accessed November 18
    • Debiotech. Debiotech-Medical Devices-Switzerland. Available at: http://www.debiotech.com/[Accessed November 18, 2011b]
    • (2011)
  • 9
    • 33645148088 scopus 로고    scopus 로고
    • The silent treatment: SiRNAs as small molecule drugs
    • D.M. Dykxhoorn, D. Palliser, J. Lieberman, The silent treatment: SiRNAs as small molecule drugs. Gene Ther 13(6), 541-552 (2006)
    • (2006) Gene Ther , vol.13 , Issue.6 , pp. 541-552
    • Dykxhoorn, D.M.1    Palliser, D.2    Lieberman, J.3
  • 10
    • 67349140642 scopus 로고    scopus 로고
    • The next generation of drug-delivery microdevices
    • N. Elman et al., The next generation of drug-delivery microdevices. Clin Pharmacol Ther 85(5), 544-547 (2009)
    • (2009) Clin Pharmacol Ther , vol.85 , Issue.5 , pp. 544-547
    • Elman, N.1
  • 11
    • 79551597266 scopus 로고    scopus 로고
    • A multidrug delivery system using a piezoelectrically actuated silicon valve manifold with embedded sensors
    • A.T. Evans, S. Chiravuri, Y.B. Gianchandani, A multidrug delivery system using a piezoelectrically actuated silicon valve manifold with embedded sensors. J Microelectromechanical Syst 20, 231-238 (2011)
    • (2011) J Microelectromechanical Syst , vol.20 , pp. 231-238
    • Evans, A.T.1    Chiravuri, S.2    Gianchandani, Y.B.3
  • 12
    • 61849153021 scopus 로고    scopus 로고
    • Impact of nanotechnology on drug delivery
    • O.C. Farokhzad, R. Langer, Impact of nanotechnology on drug delivery. ACS Nano 3, 16-20 (2009)
    • (2009) ACS Nano , vol.3 , pp. 16-20
    • Farokhzad, O.C.1    Langer, R.2
  • 14
    • 77952759689 scopus 로고    scopus 로고
    • Implantable MEMS drug delivery device for cancer radiation reduction
    • IEEE Int. Conf. MEMS Hong Kong, SAR, China
    • H. Gensler et al., Implantable MEMS drug delivery device for cancer radiation reduction. In Proc. IEEE Int. Conf. MEMS, (IEEE Int. Conf. MEMS, Hong Kong, SAR, China, 2010), pp. 23-26
    • (2010) Proc. IEEE Int. Conf. MEMS , pp. 23-26
    • Gensler, H.1
  • 15
    • 80052122884 scopus 로고    scopus 로고
    • Rapid non-lithography based fabrication process and characterization of Parylene C bellows for applications in MEMS electrochemical actuators
    • IEEE Int. Conf. TRANSDUCERS, Beijing, China
    • H. Gensler, R. Sheybani, E. Meng, Rapid non-lithography based fabrication process and characterization of Parylene C bellows for applications in MEMS electrochemical actuators. In Proc. IEEE Int. Conf. TRANSDUCERS, (IEEE Int. Conf. TRANSDUCERS, Beijing, China, 2011), pp. 2347-2350
    • (2011) Proc. IEEE Int. Conf. TRANSDUCERS , pp. 2347-2350
    • Gensler, H.1    Sheybani, R.2    Meng, E.3
  • 16
    • 0242499354 scopus 로고    scopus 로고
    • Multi-pulse drug delivery from a resorbable polymeric microchip device
    • A.C.R. Grayson et al., Multi-pulse drug delivery from a resorbable polymeric microchip device. Nat Mater 2, 767-772 (2003)
    • (2003) Nat Mater , vol.2 , pp. 767-772
    • Grayson, A.C.R.1
  • 17
    • 84861462428 scopus 로고    scopus 로고
    • iPrecio. iPRECIO®, Innovative Drug Infusion Technology for Laboratory Animals Available at:Accessed October 19
    • iPrecio. iPRECIO®, Innovative Drug Infusion Technology for Laboratory Animals. Available at: Accessed October 19 2011 http://www.iprecio.com/
    • (2011)
  • 19
    • 29144535795 scopus 로고    scopus 로고
    • Impedance spectroscopy: A powerful tool for rapid biomolecular screening and cell culture monitoring
    • DOI 10.1002/elan.200503371
    • I.O. K'Owino, O.A. Sadik, Impedance spectroscopy: A powerful tool for rapid biomolecular screening and cell culture monitoring. Electroanalysis 17, 2101-2113 (2005) (Pubitemid 41810053)
    • (2005) Electroanalysis , vol.17 , Issue.23 , pp. 2101-2113
    • K'Owino, I.O.1    Sadik, O.A.2
  • 23
    • 4344607723 scopus 로고    scopus 로고
    • Microstructure and adhesion of Au deposited on Parylene-c substrate with surface modification for potential immunoassay application
    • J.H.Lee et al., Microstructure and adhesion of Au deposited on Parylene-c substrate with surface modification for potential immunoassay application. IEEE Trans Plasma Sci 32, 505-509 (2004)
    • (2004) IEEE Trans Plasma Sci , vol.32 , pp. 505-509
    • Lee, J.H.1
  • 24
    • 84861456372 scopus 로고    scopus 로고
    • Ph.D. Dissertation Dept. Biomed. Eng., University of Southern California, Los Angeles
    • P.-Y. Li, Implantable bioMEMS drug delivery systems. Ph.D. Dissertation (Dept. Biomed. Eng., University of Southern California, Los Angeles, 2009)
    • (2009) Implantable Bio MEMS Drug Delivery Systems
    • Li, P.-Y.1
  • 27
    • 71449127775 scopus 로고    scopus 로고
    • A Parylene bellows electrochemical actuator for intraocular drug delivery
    • TRANSDUCERS, (IEEE Int. Conf. TRANSDUCERS, Denver, CO, USA
    • P.-Y. Li, et al., A Parylene bellows electrochemical actuator for intraocular drug delivery, in Proc. IEEE Int. Conf. TRANSDUCERS, (IEEE Int. Conf. TRANSDUCERS, Denver, CO, USA, 2009), pp. 1461-1464
    • (2009) Proc. IEEE Int. Conf. , pp. 1461-1464
    • Li, P.-Y.1
  • 28
    • 76349121304 scopus 로고    scopus 로고
    • A Parylene bellows electrochemical actuator
    • P.-Y. Li et al., A Parylene bellows electrochemical actuator. J Microelectromechanical Syst 19(1), 215-228 (2010)
    • (2010) J Microelectromechanical Syst , vol.19 , Issue.1 , pp. 215-228
    • Li, P.-Y.1
  • 29
    • 80053573150 scopus 로고    scopus 로고
    • A modular heat-shrink-packaged check valve with high pressure shutoff
    • R. Lo, E. Meng, A modular heat-shrink-packaged check valve with high pressure shutoff. J Microelectromechanical Syst 20, 1163-1173 (2011)
    • (2011) J Microelectromechanical Syst , vol.20 , pp. 1163-1173
    • Lo, R.1    Meng, E.2
  • 30
    • 65949093542 scopus 로고    scopus 로고
    • In-plane bandpass regulation check valve in heat-shrink packaging for drug delivery
    • IEEE Int. Conf. MEMS, Sorrento, Italy
    • R. Lo, E. Meng, In-plane Bandpass Regulation Check Valve in Heat-Shrink Packaging for Drug Delivery. In Proc. IEEE Int. Conf. MEMS. (IEEE Int. Conf. MEMS, Sorrento, Italy, 2009), pp. 236-239
    • (2009) Proc.IEEE Int. Conf. MEMS. , pp. 236-239
    • Lo, R.1    Meng, E.2
  • 31
    • 70549096974 scopus 로고    scopus 로고
    • A passive MEMS drug delivery pump for treatment of ocular diseases
    • R. Lo et al., A passive MEMS drug delivery pump for treatment of ocular diseases. Biomed Microdevices 11, 959-970 (2009)
    • (2009) Biomed Microdevices , vol.11 , pp. 959-970
    • Lo, R.1
  • 32
    • 0032674333 scopus 로고    scopus 로고
    • A high-performance silicon micropump for an implantable drug delivery system
    • IEEE, Orlando, FL, USA
    • D. Maillefer et al., A high-performance silicon micropump for an implantable drug delivery system, in Proc. IEEE Int. Conf. MEMS. IEEE Int. Conf. MEMS, (IEEE, Orlando, FL, USA, 1999), pp. 541-546
    • (1999) Proc. IEEE Int. Conf. MEMS. IEEE Int. Conf. MEMS , pp. 541-546
    • Maillefer, D.1
  • 34
    • 84861460308 scopus 로고    scopus 로고
    • Available at: Med-e-Cell.Welcome toMed-e-Cell: Infusion pumps, fluid delivery devices, oxygen generation/control and fuel cell technology for licensing and development partnerships. Accessed October 19
    • Med-e-Cell.Welcome toMed-e-Cell: Infusion pumps, fluid delivery devices, oxygen generation/control and fuel cell technology for licensing and development partnerships. Available at: http://medecell.com/[Accessed October 19, 2011d
    • (2011)
  • 35
    • 42949130010 scopus 로고    scopus 로고
    • A biocompatible Parylene thermal flow sensing array
    • DOI 10.1016/j.sna.2007.12.010, PII S0924424707009004
    • E. Meng, P.-Y. Li, Y.-C. Tai, A biocompatible Parylene thermal flow sensing array. Sens Actuators A Phys 144, 18-28 (2008) (Pubitemid 351608054)
    • (2008) Sensors and Actuators, A: Physical , vol.144 , Issue.1 , pp. 18-28
    • Meng, E.1    Li, P.-Y.2    Tai, Y.-C.3
  • 37
    • 0033736885 scopus 로고    scopus 로고
    • The electrolysis of water: An actuation principle for MEMS with a big opportunity
    • C.R. Neagu, The electrolysis of water: An actuation principle for MEMS with a big opportunity. Mechatronics 10, 571-581 (2000)
    • (2000) Mechatronics , vol.10 , pp. 571-581
    • Neagu, C.R.1
  • 40
    • 0026880981 scopus 로고
    • The platinum microelectrode/Nafion interface: An electrochemical impedance spectroscopic analysis of oxygen reduction kinetics and Nafion characteristics
    • A. Parthasarathy, The platinum microelectrode/Nafion interface: An electrochemical impedance spectroscopic analysis of oxygen reduction kinetics and Nafion characteristics. J Electrochem Soc 139, 1634 (1992)
    • (1992) J Electrochem Soc , vol.139 , pp. 1634
    • Parthasarathy, A.1
  • 41
    • 16544371952 scopus 로고    scopus 로고
    • Rat genome sequence reignites preclinical model debate
    • S. Petit-Zeman, Rat genome sequence reignites preclinical model debate. Nat Rev Drug Discov 3, 287-288 (2004)
    • (2004) Nat Rev Drug Discov , vol.3 , pp. 287-288
    • Petit-Zeman, S.1
  • 42
    • 34147165134 scopus 로고    scopus 로고
    • Drug-related side effects of long-term intrathecal morphine therapy
    • X. Ruan, Drug-related side effects of long-term intrathecal morphine therapy. Pain Physician 10(2), 357-366 (2007)
    • (2007) Pain Physician , vol.10 , Issue.2 , pp. 357-366
    • Ruan, X.1
  • 45
    • 79953798413 scopus 로고    scopus 로고
    • High efficiency wireless electrochemical actuators: Design fabrication and characterization by electrochemical impedance spectroscopy
    • IEEE Int. Conf. MEMS, Cancun, Mexico
    • R. Sheybani, E. Meng, High efficiency wireless electrochemical actuators: Design, fabrication and characterization by electrochemical impedance spectroscopy, in Proc. IEEE Int. Conf. MEMS. (IEEE Int. Conf. MEMS, Cancun, Mexico, 2011), pp. 1233-1236
    • (2011) Proc. IEEE Int. Conf. MEMS. , pp. 1233-1236
    • Sheybani, R.1    Meng, E.2
  • 46
    • 80052104810 scopus 로고    scopus 로고
    • Rapid and repeated bolus drug delivery enabled by high efficiency electrochemical bellows actuators
    • TRANSDUCERS, IEEE, Beijing, China
    • R. Sheybani, H. Gensler, E. Meng, Rapid and repeated bolus drug delivery enabled by high efficiency electrochemical bellows actuators, in Proc. IEEE Int. Conf. TRANSDUCERS. IEEE Int. Conf. TRANSDUCERS, (IEEE, Beijing, China, 2011), pp. 490493
    • (2011) Proc. IEEE Int. Conf. TRANSDUCERS. IEEE Int. Conf. , pp. 490493
    • Sheybani, R.1    Gensler, H.2    Meng, E.3
  • 47
    • 0024897405 scopus 로고
    • Piezoelectric micropump with microvalves
    • University/Government/Industry Microelectronics Symposium, IEEE
    • J.G. Smits, Piezoelectric micropump with microvalves, in Proc. University/Government/Industry Microelectronics Symposium. University/ Government/Industry Microelectronics Symposium, (IEEE 1989), pp. 92-94
    • (1989) Proc. University/Government/Industry Microelectronics Symposium , pp. 92-94
    • Smits, J.G.1
  • 48
    • 34948846146 scopus 로고    scopus 로고
    • Chronobiology, drug delivery, and chronotherapeutics
    • DOI 10.1016/j.addr.2007.07.001, PII S0169409X0700124X, Chronobiology, Drug-delivery, and Chronotherapeutics
    • M.H. Smolensky, N.A. Peppas, Chronobiology, drug delivery, and chronotherapeutics. Adv Drug Deliv Rev 59(9-10), 828-851 (2007) (Pubitemid 47542291)
    • (2007) Advanced Drug Delivery Reviews , vol.59 , Issue.9-10 , pp. 828-851
    • Smolensky, M.H.1    Peppas, N.A.2
  • 49
  • 50
    • 0033612236 scopus 로고    scopus 로고
    • More regulation of rodents
    • DOI 10.1126/science.284.5419.1463
    • F.L. Trull, B.A. Rich, More regulation of rodents. Science 284, 1463 (1999) (Pubitemid 29291380)
    • (1999) Science , vol.284 , Issue.5419 , pp. 1463
    • Trull, F.L.1    Rich, B.A.2
  • 51
    • 33847359977 scopus 로고    scopus 로고
    • Review of MEMS-based drug delivery and dosing systems
    • N.C. Tsai, C.Y. Sue, Review of MEMS-based drug delivery and dosing systems. Sens Actuators A Phys 134(2), 555-564 (2007)
    • (2007) Sens Actuators A Phys , vol.134 , Issue.2 , pp. 555-564
    • Tsai, N.C.1    Sue, C.Y.2
  • 53
    • 84855704830 scopus 로고    scopus 로고
    • Atomistic modeling of Parylene-metal interactions for surface micro-structuring
    • A.V. Vasenkov, Atomistic modeling of Parylene-metal interactions for surface micro-structuring. J Mol Model 17(12), 3219-3228 (2011)
    • (2011) J Mol Model , vol.17 , Issue.12 , pp. 3219-228
    • Vasenkov, A.V.1
  • 54
    • 13244251242 scopus 로고    scopus 로고
    • Micropumps-past, progress and future prospects
    • P. Woias, Micropumps-past, progress and future prospects. Sens Actuators B Chem 105(1), 28-38 (2005)
    • (2005) Sens Actuators B Chem , vol.105 , Issue.1 , pp. 28-38
    • Woias, P.1
  • 55
  • 56
    • 3142571514 scopus 로고    scopus 로고
    • Metal/polymer interface adhesion by partially ionized beam deposition
    • P.K. Wu et al., Metal/polymer interface adhesion by partially ionized beam deposition. J Appl Phys 80, 5759 (1996)
    • (1996) J Appl Phys , vol.80 , pp. 5759
    • Wu, P.K.1
  • 57
    • 4143114457 scopus 로고    scopus 로고
    • Chronopharmaceutics: Gimmick or clinically relevant approach to drug delivery?
    • B.B. Youan, Chronopharmaceutics: Gimmick or clinically relevant approach to drug delivery? J Control Release 98(3), 337-353 (2004)
    • (2004) J Control Release , vol.98 , Issue.3 , pp. 337-353
    • Youan, B.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.