1
-
-
11144236389
-
A BioMEMS review: MEMS technology for physiologically integrated devices
-
DOI 10.1109/JPROC.2003.820534, Biomedical Applications for Mems and Microfluidics
-
A. C. R. Grayson, R. S. Shawgo, A. M. Johnson, N. T. Flynn, L. I. Yawen, M. J. Cima, and R. Langer, "A BioMEMS review: MEMS technology for physiologically integrated devices," Proc. IEEE, vol. 92, no. 1, pp. 6-21, Jan. 2004. (Pubitemid 40890769)
-
(2004)
Proceedings of the IEEE
, vol.92
, Issue.1
, pp. 6-21
-
-
Grayson, A.C.R.1
Shawgo, R.S.2
Johnson, A.M.3
Flynn, N.T.4
Li, Y.5
Cima, M.J.6
Langer, R.7
-
2
-
-
0033611506
-
A controlled-release microchip
-
DOI 10.1038/16898
-
J. T. Santini, M. J. Cima, and R. Langer, "A controlled-release microchip," Nature, vol. 397, no. 6717, pp. 335-338, Jan. 28, 1999. (Pubitemid 29061643)
-
(1999)
Nature
, vol.397
, Issue.6717
, pp. 335-338
-
-
Santini Jr., J.T.1
Cima, M.J.2
Langer, R.3
-
3
-
-
0031214943
-
A multichannel neural probe for selective chemical delivery at the cellular level
-
DOI 10.1109/10.605435, PII S0018929497053548
-
J. K. Chen, K. D. Wise, J. F. Hetke, and S. C. Bledsoe, "A multichannel neural probe for selective chemical delivery at the cellular level," IEEE Trans. Biomed. Eng., vol. 44, no. 8, pp. 760-769, Aug. 1997. (Pubitemid 27314086)
-
(1997)
IEEE Transactions on Biomedical Engineering
, vol.44
, Issue.8
, pp. 760-769
-
-
Chen, J.1
Wise, K.D.2
Hetke, J.F.3
Bledsoe Jr., S.C.4
-
4
-
-
65949093542
-
In-plane bandpass regulation check valve in heatshrink packaging for drug delivery
-
R. Lo and E. Meng, "In-plane bandpass regulation check valve in heatshrink packaging for drug delivery," in Proc. IEEE 22nd Int. Conf. Micro Electro Mech. Syst., 2009, pp. 236-239.
-
(2009)
Proc. IEEE 22nd Int. Conf. Micro Electro Mech. Syst.
, pp. 236-239
-
-
Lo, R.1
Meng, E.2
-
5
-
-
40949113246
-
An electrochemical intraocular drug delivery device
-
DOI 10.1016/j.sna.2007.06.034, PII S0924424707005286
-
P. Y. Li, J. Shih, R. Lo, S. Saati, R. Agrawal, M. S. Humayun, Y. C. Tai, and E.Meng, "An electrochemical intraocular drug delivery device," Sens. Actuators A, Phys., vol. 143, pp. 41-48, May 2, 2008. (Pubitemid 351417358)
-
(2008)
Sensors and Actuators, A: Physical
, vol.143
, Issue.1
, pp. 41-48
-
-
Li, P.-Y.1
Shih, J.2
Lo, R.3
Saati, S.4
Agrawal, R.5
Humayun, M.S.6
Tai, Y.-C.7
Meng, E.8
-
6
-
-
70549096974
-
A passive MEMS drug delivery pump for treatment of ocular diseases
-
Oct
-
R. Lo, P.-Y. Li, S. Saati, R. N. Agrawal, M. S. Humayun, and E. Meng, "A passive MEMS drug delivery pump for treatment of ocular diseases," Biomed. Microdevices, vol. 11, no. 5, pp. 959-970, Oct 2009.
-
(2009)
Biomed. Microdevices
, vol.11
, Issue.5
, pp. 959-970
-
-
Lo, R.1
Li, P.-Y.2
Saati, S.3
Agrawal, R.N.4
Humayun, M.S.5
Meng, E.6
-
7
-
-
0003738464
-
-
St. Louis, MO: Mosby
-
R. Ritch,M. B. Shields, and T. Krupin, The Glaucomas, vol. 2. St. Louis, MO: Mosby, 1989.
-
(1989)
The Glaucomas
, vol.2
-
-
Ritch, R.1
Shields, M.B.2
Krupin, T.3
-
8
-
-
0032782688
-
The role of medical therapy in the rank order of glaucoma treatment
-
DOI 10.1097/00055735-199904000-00005
-
J. T. Wilensky, "The role of medical therapy in the rank order of glaucoma treatment," Curr. Opin. Ophthalmol., vol. 10, no. 2, pp. 109-111, Apr. 1999. (Pubitemid 29342531)
-
(1999)
Current Opinion in Ophthalmology
, vol.10
, Issue.2
, pp. 109-111
-
-
Wilensky, J.T.1
-
9
-
-
33744461297
-
A review of microvalves
-
DOI 10.1088/0960-1317/16/5/R01, PII S0960131706074213
-
K. W. Oh and C. H. Ahn, "A review of microvalves," J. Micromech. Microeng., vol. 16, no. 5, pp. R13-R39, May 2006. (Pubitemid 43803185)
-
(2006)
Journal of Micromechanics and Microengineering
, vol.16
, Issue.5
-
-
Oh, K.W.1
Ahn, C.H.2
-
10
-
-
65949120027
-
Minimally invasive Parylene dual-valved flow drainage shunt for glaucoma implant
-
J. C.-H. Lin, P.-J. Chen, B. Yu, M. Humayun, and Y.-C. Tai, "Minimally invasive Parylene dual-valved flow drainage shunt for glaucoma implant," in Proc. IEEE 22nd Int. Conf. Micro Electro Mech. Syst., 2009, pp. 196-199.
-
(2009)
Proc. IEEE 22nd Int. Conf. Micro Electro Mech. Syst.
, pp. 196-199
-
-
Lin, J.C.-H.1
Chen, P.-J.2
Yu, B.3
Humayun, M.4
Tai, Y.-C.5
-
12
-
-
50149091974
-
Miniaturization of on-wall in-tube flexible thermal flow sensor using heat shrinkable tube
-
Tucson, AZ
-
J. Naito, M. Shikida, M. Hirota, Z. Y. Tan, and K. Sato, "Miniaturization of on-wall in-tube flexible thermal flow sensor using heat shrinkable tube," in Proc. IEEE Int. Conf. Micro Electro Mech. Syst., Tucson, AZ, 2008, pp. 924-927.
-
(2008)
Proc. IEEE Int. Conf. Micro Electro Mech. Syst.
, pp. 924-927
-
-
Naito, J.1
Shikida, M.2
Hirota, M.3
Tan, Z.Y.4
Sato, K.5
-
13
-
-
34047163118
-
An artificial nano-drainage implant (ANDI) for glaucoma treatment
-
DOI 10.1109/IEMBS.2006.260147, 4029571, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
-
T. Pan, J. D. Brown, and B. Ziaie, "An artificial nano-drainage implant (ANDI) for glaucoma treatment," in Proc. IEEE Eng. Med. Biol. Soc., Piscataway, NJ, 2006, pp. 3174-3177. (Pubitemid 46520583)
-
(2006)
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
, pp. 3174-3177
-
-
Pan, T.1
Brown, J.D.2
Ziaie, B.3
-
14
-
-
0037400556
-
Biocompatibility and biofouling of MEMS drug delivery devices
-
DOI 10.1016/S0142-9612(02)00565-3
-
G. Voskerician, M. S. Shive, R. S. Shawgo, H. V. Recum, J. M. Anderson, M. J. Cima, and R. Langer, "Biocompatibility and biofouling of MEMS drug delivery devices," Biomaterials, vol. 24, no. 11, pp. 1959-1967, May 2003. (Pubitemid 36297040)
-
(2003)
Biomaterials
, vol.24
, Issue.11
, pp. 1959-1967
-
-
Voskerician, G.1
Shive, M.S.2
Shawgo, R.S.3
Von Recum, H.4
Anderson, J.M.5
Cima, M.J.6
Langer, R.7
-
15
-
-
80053571707
-
-
Zeus Industrial Products, Inc., Orangeburg, SC, FEP Resin Properties
-
Zeus Industrial Products, Inc., Orangeburg, SC, FEP Resin Properties.
-
-
-
-
17
-
-
0035392006
-
Micro-electro-mechanical system fabrication technology applied to large area x-ray image sensor arrays
-
DOI 10.1116/1.1380226
-
J. H. Daniel, B. Krusor, R. B. Apte, M. Mulato, K. V. Schuylenbergh, R. Lau, T. Do, R. A. Street, A. Goredema, D. C. Boils-Boissier, and P. M. Kazmaier, "Micro-electro-mechanical system fabrication technology applied to large area X-ray image sensor arrays," J. Vac. Sci. Technol. A, vol. 19, no. 4, pp. 1219-1223, Jul. 2001. (Pubitemid 32704970)
-
(2001)
Journal of Vacuum Science and Technology, Part A: Vacuum, Surfaces and Films
, vol.19
, Issue.4
, pp. 1219-1223
-
-
Daniel, J.H.1
Krusor, B.2
Apte, R.B.3
Mulato, M.4
Van Schuylenbergh, K.5
Lau, R.6
Do, T.7
Street, R.A.8
Goredema, A.9
Boils-Boissier, D.C.10
Kazmaier, P.M.11
-
18
-
-
78649736162
-
UV-LIGA microfabrication of 220 GHz sheet beam amplifier gratings with SU-8 photoresists
-
Dec.
-
C. D. Joye, J. P. Calame, M. Garven, and B. Levush, "UV-LIGA microfabrication of 220 GHz sheet beam amplifier gratings with SU-8 photoresists," J. Micromech. Microeng., vol. 20, no. 12, p. 125 016, Dec. 2010.
-
(2010)
J. Micromech. Microeng.
, vol.20
, Issue.12
, pp. 125016
-
-
Joye, C.D.1
Calame, J.P.2
Garven, M.3
Levush, B.4
-
19
-
-
4344680330
-
A method for precision patterning of silicone elastomer and its applications
-
Aug.
-
R. K. Suk,W. Xuefeng, K. Shaikh, and L. Chang, "A method for precision patterning of silicone elastomer and its applications," J. Microelectromech. Syst., vol. 13, no. 4, pp. 568-575, Aug. 2004.
-
(2004)
J. Microelectromech. Syst.
, vol.13
, Issue.4
, pp. 568-575
-
-
Suk, R.K.1
Xuefeng, W.2
Shaikh, K.3
Chang, L.4
-
20
-
-
0032665520
-
A Parylene micro check valve
-
X.-Q. Wang, Q. Lin, and Y.-C. Tai, "A Parylene micro check valve," in Proc. 12th IEEE Int. Conf. Micro Electro Mech. Syst., 1999, pp. 177-182.
-
(1999)
Proc. 12th IEEE Int. Conf. Micro Electro Mech. Syst.
, pp. 177-182
-
-
Wang, X.-Q.1
Lin, Q.2
Tai, Y.-C.3
-
21
-
-
2342636454
-
Removable tubing interconnects for glass-based micro-fluidic systems made using ECDM
-
Apr.
-
E. S. Lee, D. Howard, E. Liang, S. D. Collins, and R. L. Smith, "Removable tubing interconnects for glass-based micro-fluidic systems made using ECDM," J. Micromech. Microeng., vol. 14, no. 4, pp. 535-541, Apr. 2004.
-
(2004)
J. Micromech. Microeng.
, vol.14
, Issue.4
, pp. 535-541
-
-
Lee, E.S.1
Howard, D.2
Liang, E.3
Collins, S.D.4
Smith, R.L.5
-
22
-
-
0036152932
-
Self-aligning microfluidic interconnects for glass- and plastic-based microfluidic systems
-
DOI 10.1088/0960-1317/12/1/306, PII S0960131702262440
-
A. Puntambekar and C. H. Ahn, "Self-aligning microfluidic interconnects for glass-and plastic-based microfluidic systems," J. Micromech. Microeng., vol. 12, no. 1, pp. 35-40, Jan. 2002. (Pubitemid 34090232)
-
(2002)
Journal of Micromechanics and Microengineering
, vol.12
, Issue.1
, pp. 35-40
-
-
Puntambekar, A.1
Ahn, C.H.2
-
23
-
-
0035443908
-
Micro-to-macro fluidic interconnectors with an integrated polymer sealant
-
Sep.
-
J. H. Tsai and L. W. Lin, "Micro-to-macro fluidic interconnectors with an integrated polymer sealant," J. Micromech. Microeng., vol. 11, no. 5, pp. 577-581, Sep. 2001.
-
(2001)
J. Micromech. Microeng.
, vol.11
, Issue.5
, pp. 577-581
-
-
Tsai, J.H.1
Lin, L.W.2
|