메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 445-453

Squeaking in Third- and Fourth-Generation Ceramic-on-Ceramic Total Hip Arthroplasty. Meta-Analysis and Systematic Review

Author keywords

Arthroplasty; Ceramic; Hip; Meta analysis; Squeak

Indexed keywords

ALUMINUM OXIDE; TITANIUM;

EID: 84857115415     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2011.04.031     Document Type: Article
Times cited : (102)

References (48)
  • 1
    • 0032786064 scopus 로고    scopus 로고
    • Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement
    • Maloney W.J., Galante J.O., Anderson M., et al. Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement. Clin Orthop Relat Res 1999, 369:157.
    • (1999) Clin Orthop Relat Res , vol.369 , pp. 157
    • Maloney, W.J.1    Galante, J.O.2    Anderson, M.3
  • 2
    • 0032905720 scopus 로고    scopus 로고
    • The porous-coated anatomic total hip prosthesis, inserted without cement. A prospective study with a minimum of ten years of follow-up
    • Xenos J.S., Callaghan J.J., Heekin R.D., et al. The porous-coated anatomic total hip prosthesis, inserted without cement. A prospective study with a minimum of ten years of follow-up. J Bone Joint Surg Am 1999, 81:74.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 74
    • Xenos, J.S.1    Callaghan, J.J.2    Heekin, R.D.3
  • 3
    • 4344667565 scopus 로고    scopus 로고
    • Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model
    • Oonishi H., Clarke I.C., Good V., et al. Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model. J Biomed Mater Res A 2004, 70:4.
    • (2004) J Biomed Mater Res A , vol.70 , pp. 4
    • Oonishi, H.1    Clarke, I.C.2    Good, V.3
  • 4
    • 0035882726 scopus 로고    scopus 로고
    • Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions
    • Nevelos J.E., Ingham E., Doyle C., et al. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials 2001, 22:16.
    • (2001) Biomaterials , vol.22 , pp. 16
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3
  • 5
    • 0037657959 scopus 로고    scopus 로고
    • Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study
    • Allain J., Roudot-Thoraval F., Delecrin J., et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg Am 2003, 85-A:825.
    • (2003) J Bone Joint Surg Am , pp. 825
    • Allain, J.1    Roudot-Thoraval, F.2    Delecrin, J.3
  • 6
    • 0038005468 scopus 로고    scopus 로고
    • Massive metallosis after revision of a fractured ceramic head onto a metal head
    • Matziolis G., Perka C., Disch A. Massive metallosis after revision of a fractured ceramic head onto a metal head. Arch Orthop Trauma Surg 2003, 123:48.
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 48
    • Matziolis, G.1    Perka, C.2    Disch, A.3
  • 8
    • 0031758471 scopus 로고    scopus 로고
    • Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces
    • Yoon T.R., Rowe S.M., Jung S.T., et al. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg Am 1998, 80:1459.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1459
    • Yoon, T.R.1    Rowe, S.M.2    Jung, S.T.3
  • 10
    • 0036056821 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study
    • Hamadouche M., Boutin P., Daussange J., et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 2002, 84:69.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 69
    • Hamadouche, M.1    Boutin, P.2    Daussange, J.3
  • 11
    • 0033779539 scopus 로고    scopus 로고
    • Evolution of alumina-on-alumina implants: a review
    • Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res 2000, 379:48.
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 48
    • Sedel, L.1
  • 12
    • 21844437667 scopus 로고    scopus 로고
    • Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study
    • D'Antonio J., Capello W., Manley M., et al. Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res 2005, 436:164.
    • (2005) Clin Orthop Relat Res , vol.436 , pp. 164
    • D'Antonio, J.1    Capello, W.2    Manley, M.3
  • 13
    • 33845411069 scopus 로고    scopus 로고
    • Two- to nine-year clinical results of alumina ceramic-on-ceramic THA
    • Murphy S.B., Ecker T.M., Tannast M. Two- to nine-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res 2006, 453:97.
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 97
    • Murphy, S.B.1    Ecker, T.M.2    Tannast, M.3
  • 14
    • 0035215635 scopus 로고    scopus 로고
    • Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty
    • Morlock M., Nassutt R., Janssen R., et al. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty 2001, 16:1071.
    • (2001) J Arthroplasty , vol.16 , pp. 1071
    • Morlock, M.1    Nassutt, R.2    Janssen, R.3
  • 15
    • 35948943543 scopus 로고    scopus 로고
    • The squeaking hip: a cause for concern-agrees
    • Ranawat AS, Ranawat CS. The squeaking hip: a cause for concern-agrees. Orthopedics. 2007;30(9):738,743.
    • (2007) Orthopedics. , vol.30 , Issue.9 , pp. 738-743
    • Ranawat, A.S.1    Ranawat, C.S.2
  • 16
    • 38449101029 scopus 로고    scopus 로고
    • The squeaking hip a cause for concern-disagrees
    • Yang C.C., Kim R.H., Dennis D.A. The squeaking hip a cause for concern-disagrees. Orthopedics 2007, 30:739.
    • (2007) Orthopedics , vol.30 , pp. 739
    • Yang, C.C.1    Kim, R.H.2    Dennis, D.A.3
  • 17
    • 34249933860 scopus 로고    scopus 로고
    • Squeaking in ceramic-on-ceramic hips. The importance of acetabular component orientation
    • Walter W.L., O'Toole G.C., Walter W.K., et al. Squeaking in ceramic-on-ceramic hips. The importance of acetabular component orientation. J Arthroplasty 2007, 22:496.
    • (2007) J Arthroplasty , vol.22 , pp. 496
    • Walter, W.L.1    O'Toole, G.C.2    Walter, W.K.3
  • 18
    • 36849075129 scopus 로고    scopus 로고
    • Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty
    • Lusty P.J., et al. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am 2007, 89:2676.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2676
    • Lusty, P.J.1
  • 19
    • 44949094495 scopus 로고    scopus 로고
    • High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings
    • Keurentjes J.C., Kuipers R.M., Wever D.J., et al. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res 2008, 466:1438.
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 1438
    • Keurentjes, J.C.1    Kuipers, R.M.2    Wever, D.J.3
  • 20
    • 44649167688 scopus 로고    scopus 로고
    • Cementless total hip arthroplasty with alumina bearings in patients younger then fifty with femoral head osteonecrosis
    • Baek S.H., Kim S.Y. Cementless total hip arthroplasty with alumina bearings in patients younger then fifty with femoral head osteonecrosis. J Bone Joint Surg Am 2008, 90:1314.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1314
    • Baek, S.H.1    Kim, S.Y.2
  • 21
    • 48949118899 scopus 로고    scopus 로고
    • The noisy ceramic hip: is component malpositioning the cause?
    • Restrepo C., Parvizi J., Kurtz S.M., et al. The noisy ceramic hip: is component malpositioning the cause?. J Arthroplasty 2008, 23:643.
    • (2008) J Arthroplasty , vol.23 , pp. 643
    • Restrepo, C.1    Parvizi, J.2    Kurtz, S.M.3
  • 23
    • 58149337269 scopus 로고    scopus 로고
    • Squeaking in total hip replacement: no cause for concern
    • Ecker T.M., Robbins C., van Flandern G., et al. Squeaking in total hip replacement: no cause for concern. Orthopedics 2008, 31:875.
    • (2008) Orthopedics , vol.31 , pp. 875
    • Ecker, T.M.1    Robbins, C.2    van Flandern, G.3
  • 25
    • 76249109227 scopus 로고    scopus 로고
    • THA with Delta ceramic on ceramic results of a multicenter investigational device exemption trial
    • Hamilton W.G., McAuley J.P., Dennis D.A., et al. THA with Delta ceramic on ceramic results of a multicenter investigational device exemption trial. Clin Orthop Relat Res 2009, 468:358.
    • (2009) Clin Orthop Relat Res , vol.468 , pp. 358
    • Hamilton, W.G.1    McAuley, J.P.2    Dennis, D.A.3
  • 26
    • 78549292127 scopus 로고    scopus 로고
    • Cementless total hip arthroplasty with ceramic-on-ceramic bearings in patients younger than 45 years with femoral-head osteonecrosis
    • Kim Y.H., Choi Y., Kim J.S. Cementless total hip arthroplasty with ceramic-on-ceramic bearings in patients younger than 45 years with femoral-head osteonecrosis. Int Orthop 2010, 34:1123.
    • (2010) Int Orthop , vol.34 , pp. 1123
    • Kim, Y.H.1    Choi, Y.2    Kim, J.S.3
  • 27
    • 67649881919 scopus 로고    scopus 로고
    • The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty
    • Jarrett C.A., Ranawat A.S., Bruzzone M., et al. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am 2009, 91:1344.
    • (2009) J Bone Joint Surg Am , vol.91 , pp. 1344
    • Jarrett, C.A.1    Ranawat, A.S.2    Bruzzone, M.3
  • 28
    • 76249108168 scopus 로고    scopus 로고
    • Incidence of "squeaking" after ceramic-on-ceramic total hip arhtroplasty
    • Mai K., Verioti C., Exet K., et al. Incidence of "squeaking" after ceramic-on-ceramic total hip arhtroplasty. Clin Orthop Relat Res 2010, 468:413.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 413
    • Mai, K.1    Verioti, C.2    Exet, K.3
  • 29
    • 85100415918 scopus 로고    scopus 로고
    • The Cochrane Collaboration, Version 5.0.2 [updated September 2009] Available from, J.P.T. Higgins, S. Green (Eds.)
    • Cochrane handbook for systematic reviews of interventions 2009, The Cochrane Collaboration, Version 5.0.2 [updated September 2009] Available from. http://www.cochrane-handbook.org, J.P.T. Higgins, S. Green (Eds.).
    • (2009) Cochrane handbook for systematic reviews of interventions
  • 30
    • 0033610734 scopus 로고    scopus 로고
    • Improving the quality of reports of meta-analyses of randomised controlled trials: the QUOROM statement. Quality of Reporting of Meta-analyses
    • Moher D., Cook D.J., Eastwood S., et al. Improving the quality of reports of meta-analyses of randomised controlled trials: the QUOROM statement. Quality of Reporting of Meta-analyses. Lancet 1999, 354:1896.
    • (1999) Lancet , vol.354 , pp. 1896
    • Moher, D.1    Cook, D.J.2    Eastwood, S.3
  • 31
    • 0035857966 scopus 로고    scopus 로고
    • The CONSORT statement: revised recommendations for improving the quality of reports of parallel-group randomised trials
    • Moher D., Schulz K.F., Altman D.G. The CONSORT statement: revised recommendations for improving the quality of reports of parallel-group randomised trials. Lancet 2001, 357:1191.
    • (2001) Lancet , vol.357 , pp. 1191
    • Moher, D.1    Schulz, K.F.2    Altman, D.G.3
  • 32
    • 21544449115 scopus 로고    scopus 로고
    • Estimating the mean and variance from the median, range, and the size of a sample
    • Hozo S.P., Djulbegovic B., Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 2005, 5:13.
    • (2005) BMC Med Res Methodol , vol.5 , pp. 13
    • Hozo, S.P.1    Djulbegovic, B.2    Hozo, I.3
  • 33
    • 84959801619 scopus 로고
    • Statistical aspects of the analysis of data from retrospective studies of disease
    • Mantel N., Haenszel W. Statistical aspects of the analysis of data from retrospective studies of disease. J Natl Cancer Inst 1959, 22:719.
    • (1959) J Natl Cancer Inst , vol.22 , pp. 719
    • Mantel, N.1    Haenszel, W.2
  • 34
    • 0041876133 scopus 로고    scopus 로고
    • Measuring inconsistency in meta-analyses
    • Higgins J.P., Thompson S.G., Deeks J.J., et al. Measuring inconsistency in meta-analyses. BMJ 2003, 327:557.
    • (2003) BMJ , vol.327 , pp. 557
    • Higgins, J.P.1    Thompson, S.G.2    Deeks, J.J.3
  • 38
    • 33644794333 scopus 로고    scopus 로고
    • A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3 to 5 year results
    • D'Antonio J.A., Capello W.N., Manley M.T., et al. A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3 to 5 year results. Clin Orthop Relat Res 2005, 441:151.
    • (2005) Clin Orthop Relat Res , vol.441 , pp. 151
    • D'Antonio, J.A.1    Capello, W.N.2    Manley, M.T.3
  • 40
    • 0348136065 scopus 로고    scopus 로고
    • Clinical and simulator wear study of alumina ceramic THR to 17 years and beyond
    • Shishido T., Clarke I., Williams P., et al. Clinical and simulator wear study of alumina ceramic THR to 17 years and beyond. J Biomed Mater Res B Allp Biomater 2003, 67:638.
    • (2003) J Biomed Mater Res B Allp Biomater , vol.67 , pp. 638
    • Shishido, T.1    Clarke, I.2    Williams, P.3
  • 41
    • 55849087920 scopus 로고    scopus 로고
    • Clicking and squeaking: in vivo correlation of sound and separation for different bearing surfaces
    • Glaser D., Komistek R.D., Cates H.E., et al. Clicking and squeaking: in vivo correlation of sound and separation for different bearing surfaces. J Bone Joint Surg Am 2008, 90:112.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 112
    • Glaser, D.1    Komistek, R.D.2    Cates, H.E.3
  • 42
    • 72549086280 scopus 로고    scopus 로고
    • Three-dimensional modeling of in vitro hip kinematics under micro-separation regime for ceramic on ceramic total hip prosthesis: an analysis of vibration and noise
    • Sariali E., Stewart T., Jin Z., et al. Three-dimensional modeling of in vitro hip kinematics under micro-separation regime for ceramic on ceramic total hip prosthesis: an analysis of vibration and noise. J Biomech 2010, 43:326.
    • (2010) J Biomech , vol.43 , pp. 326
    • Sariali, E.1    Stewart, T.2    Jin, Z.3
  • 43
    • 34848915750 scopus 로고    scopus 로고
    • The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings
    • Taylor S., Manley M.T., Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty 2007, 22(Supp 3):47.
    • (2007) J Arthroplasty , vol.22 , Issue.SUPPL. 3 , pp. 47
    • Taylor, S.1    Manley, M.T.2    Sutton, K.3
  • 44
    • 76249101648 scopus 로고    scopus 로고
    • The 2009 Frank Stinchfield award: "hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces
    • Chevillotte C., Trousdale R.T., Chen Q., et al. The 2009 Frank Stinchfield award: "hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces. Clin Orthop Relat Res 2010, 468:345.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 345
    • Chevillotte, C.1    Trousdale, R.T.2    Chen, Q.3
  • 46
    • 52449134811 scopus 로고    scopus 로고
    • How do altervative bearing surfaces influence wear behavior?
    • Implant Wear Symposium 2007 Engineering Work Group
    • Clarke I.C., Manley M.T. How do altervative bearing surfaces influence wear behavior?. J Am Acad Orthop Surg. 2008, 16(Supp 1):S86. Implant Wear Symposium 2007 Engineering Work Group.
    • (2008) J Am Acad Orthop Surg. , vol.16 , Issue.SUPPL. 1
    • Clarke, I.C.1    Manley, M.T.2
  • 48
    • 58149359138 scopus 로고    scopus 로고
    • Squeaking in total hip replacement: a cause for concern
    • Rodriguez J.A., DelaValle A.G., McCook N. Squeaking in total hip replacement: a cause for concern. Orthopedics 2008, 31:874.
    • (2008) Orthopedics , vol.31 , pp. 874
    • Rodriguez, J.A.1    DelaValle, A.G.2    McCook, N.3