메뉴 건너뛰기




Volumn 91, Issue 6, 2009, Pages 1344-1349

The squeaking hip: A phenomenon of ceramic-on-ceramic total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGE DISTRIBUTION; AGED; ARTICLE; BODY MASS; CERAMIC ON CERAMIC TOTAL HIP ARTHROPLASTY; CERAMIC PROSTHESIS; CONTROLLED STUDY; FEMALE; FOLLOW UP; HIP DISLOCATION; HIP RADIOGRAPHY; HUMAN; INCIDENCE; MAJOR CLINICAL STUDY; MALE; METAL ON POLYETHYLENE TOTAL HIP ARTHROPLASTY; OUTCOME ASSESSMENT; PAIN ASSESSMENT; PATIENT SATISFACTION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; PROSTHESIS FAILURE; QUESTIONNAIRE; SCORING SYSTEM; SELF REPORT; SEX RATIO; SQUEAKING HIP PROSTHESIS; TOTAL HIP PROSTHESIS; CASE CONTROL STUDY; CERAMICS; CHI SQUARE DISTRIBUTION; COMPARATIVE STUDY; EQUIPMENT; HIP; HIP PROSTHESIS; JOINT CHARACTERISTICS AND FUNCTIONS; MIDDLE AGED; PATHOPHYSIOLOGY; POSTOPERATIVE COMPLICATION; PROBABILITY; PROSTHESIS; SENSITIVITY AND SPECIFICITY; SOUND; SURFACE PROPERTY; TIME;

EID: 67649881919     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/JBJS.F.00970     Document Type: Article
Times cited : (222)

References (31)
  • 1
    • 9644290786 scopus 로고    scopus 로고
    • Metal-on-metal total hip arthroplasty: The concerns
    • DOI 10.1097/01.blo.0000150309.48474.8b
    • MacDonald SJ. Metal on metal total hip arthroplasty: the concerns. Clin Orthop Relat Res. 2004;429:86-93. (Pubitemid 39579197)
    • (2004) Clinical Orthopaedics and Related Research , Issue.429 , pp. 86-93
    • MacDonald, S.J.1
  • 4
    • 70349915911 scopus 로고    scopus 로고
    • Modern ceramic-on-ceramic bearings in total hip arthroplasty - Minimum five-year follow-up
    • Walter WK, Zicat B, O'Sullivan M, Walter WL. Modern ceramic-on-ceramic bearings in total hip arthroplasty - minimum five-year follow-up. J Bone Joint Surg Br. 2005;87 Suppl 3:361-362
    • (2005) J Bone Joint Surg Br , vol.87 , Issue.SUPPL. 3 , pp. 361-362
    • Walter, W.K.1    Zicat, B.2    O'Sullivan, M.3    Walter, W.L.4
  • 7
    • 0015319816 scopus 로고
    • Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications
    • French
    • Boutin P. [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]. Rev Chir Orthop Reparatrice Appar Mot. 1972;58:229-246 French.
    • (1972) Rev Chir Orthop Reparatrice Appar Mot , vol.58 , pp. 229-246
    • Boutin, P.1
  • 9
    • 0033779539 scopus 로고    scopus 로고
    • Evolution of alumina-on-alumina implants: A review
    • Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000;379:48-54.
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 48-54
    • Sedel, L.1
  • 10
    • 0000809293 scopus 로고    scopus 로고
    • Perspective on a 20-year experience with ceramic-on-ceramic articulation in total hip replacement
    • Sedel L, Nizard R, Bizot P, Meunier A. Perspective on a 20-year experience with ceramic-on-ceramic articulation in total hip replacement. Semin Arthroplasty. 1999;9:123-134
    • (1999) Semin Arthroplasty , vol.9 , pp. 123-134
    • Sedel, L.1    Nizard, R.2    Bizot, P.3    Meunier, A.4
  • 11
    • 0026782886 scopus 로고
    • Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic to ceramic bearings
    • Clarke IC. Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic to ceramic bearings. Clin Orthop Relat Res. 1992;282:19-30.
    • (1992) Clin Orthop Relat Res , vol.282 , pp. 19-30
    • Clarke, I.C.1
  • 12
    • 0033779502 scopus 로고    scopus 로고
    • Modern ceramic-on-ceramic total hip systems in the United States: Early results
    • Garino JP. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res. 2000;379:41-47
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 41-47
    • Garino, J.P.1
  • 13
    • 0001549373 scopus 로고    scopus 로고
    • Ceramics in total hip arthroplasty: History, mechanical properties, clinical results, and current manufacturing state of the art
    • Heros RJ, Willmann G. Ceramics in total hip arthroplasty: history, mechanical properties, clinical results, and current manufacturing state of the art. Semin Arthroplasty. 1998;9:114-122
    • (1998) Semin Arthroplasty , vol.9 , pp. 114-122
    • Heros, R.J.1    Willmann, G.2
  • 14
    • 21844437667 scopus 로고    scopus 로고
    • Alumina ceramic bearings for total hip arthroplasty: Five-year results of a prospective randomized study
    • DOI 10.1097/01.blo.0000162995.50971.39
    • D'Antonio J, Capello W, Manley M, Naughton M, Sutton K. Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res. 2005;436:164-171 (Pubitemid 40961043)
    • (2005) Clinical Orthopaedics and Related Research , Issue.436 , pp. 164-171
    • D'Antonio, J.1    Capello, W.2    Manley, M.3    Naughton, M.4    Sutton, K.5
  • 16
    • 0037248995 scopus 로고    scopus 로고
    • Ceramic on ceramic bearings in total hip arthroplasty
    • Buchanan JM. Ceramic on ceramic bearings in total hip arthroplasty. Key Eng Mater. 2003;240-2:793-796
    • (2003) Key Eng Mater , vol.240-242 , pp. 793-796
    • Buchanan, J.M.1
  • 19
    • 0035215635 scopus 로고    scopus 로고
    • Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty
    • DOI 10.1054/arth.2001.27233
    • Morlock M, Nassutt R, Janssen R, Willmann G, Honl M. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty. 2001;16:1071-1074 (Pubitemid 33151887)
    • (2001) Journal of Arthroplasty , vol.16 , Issue.8 , pp. 1071-1074
    • Morlock, M.1    Nassutt, R.2    Janssen, R.3    Willmann, G.4    Honl, M.5
  • 20
    • 0001566619 scopus 로고    scopus 로고
    • Clinical wear performance of metal-on-metal hip arthroplasties
    • Jacobs JJ, Craig TL, editors. Alternative bearing surfaces in total joint replacement. West Conshohocken, PA: American Society for Testing and Materials
    • Rieker CB, Koettig P, Schoen R, Windler M, Wyess UP. Clinical wear performance of metal-on-metal hip arthroplasties. In: Jacobs JJ, Craig TL, editors. Alternative bearing surfaces in total joint replacement. ASTM Spec Tech Publ 1346. West Conshohocken, PA: American Society for Testing and Materials; 1998. p 144.
    • (1998) ASTM Spec Tech Publ 1346 , pp. 144
    • Rieker, C.B.1    Koettig, P.2    Schoen, R.3    Windler, M.4    Wyess, U.P.5
  • 22
    • 33644794333 scopus 로고    scopus 로고
    • A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- To 5-year results
    • DOI 10.1097/01.blo.0000194084.67364.6c, PII 0000308620051200000025
    • D'Antonio JA, Capello WN, Manley MT, Naughton M, Sutton K. A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results. Clin Orthop Relat Res. 2005;441:151-158 (Pubitemid 44384217)
    • (2005) Clinical Orthopaedics and Related Research , Issue.441 , pp. 151-158
    • D'Antonio, J.A.1    Capello, W.N.2    Manley, M.T.3    Naughton, M.4    Sutton, K.5
  • 24
    • 0015304601 scopus 로고
    • Total hip replacement with fixation by acrylic cement. a preliminary study of 100 consecutive McKee-Farrar prosthetic replacements
    • Wilson PD Jr, Amstutz HC, Czerniecki A, Salvati EA, Mendes DG. Total hip replacement with fixation by acrylic cement. A preliminary study of 100 consecutive McKee-Farrar prosthetic replacements. J Bone Joint Surg Am. 1972;54:207-236
    • (1972) J Bone Joint Surg Am , vol.54 , pp. 207-236
    • Wilson Jr., P.D.1    Amstutz, H.C.2    Czerniecki, A.3    Salvati, E.A.4    Mendes, D.G.5
  • 25
    • 0030669292 scopus 로고    scopus 로고
    • Determination of polyethylene wear in total hip replacements with use of digital radiographs
    • Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635-1641 (Pubitemid 27508522)
    • (1997) Journal of Bone and Joint Surgery - Series a , vol.79 , Issue.11 , pp. 1635-1641
    • Martell, J.M.1    Berdia, S.2
  • 26
    • 0031034439 scopus 로고    scopus 로고
    • Fracture of a ceramic femoral head after a revision operation. a case report
    • Pulliam IT, Trousdale RT. Fracture of a ceramic femoral head after a revision operation. A case report. J Bone Joint Surg Am. 1997;79:118-121
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 118-121
    • Pulliam, I.T.1    Trousdale, R.T.2
  • 27
    • 34848915750 scopus 로고    scopus 로고
    • The Role of Stripe Wear in Causing Acoustic Emissions from Alumina Ceramic-On-Ceramic Bearings
    • DOI 10.1016/j.arth.2007.05.038, PII S088354030700318X
    • Taylor S, Manley MT, Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty. 2007;22(7 Suppl 3):47-51. (Pubitemid 47494618)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.7 SUPPL. , pp. 47-51
    • Taylor, S.1    Manley, M.T.2    Sutton, K.3
  • 28
    • 0035034742 scopus 로고    scopus 로고
    • Outcomes evaluation in orthopaedics
    • Dawson J, Carr A. Outcomes evaluation in orthopaedics. J Bone Joint Surg Br. 2001;83:313-315
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 313-315
    • Dawson, J.1    Carr, A.2
  • 29
    • 0026625069 scopus 로고
    • A self-administered hip-rating questionnaire for the assessment of outcome after total hip replacement
    • Johanson NA, Charlson ME, Szatrowski TP, Ranawat CS. A self-administered hip-rating questionnaire for the assessment of outcome after total hip replacement. J Bone Joint Surg Am. 1992;74:587-597
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 587-597
    • Johanson, N.A.1    Charlson, M.E.2    Szatrowski, T.P.3    Ranawat, C.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.