메뉴 건너뛰기




Volumn 70, Issue 4, 2004, Pages 523-532

Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model

Author keywords

Alumina; Ceramic; Hip arthroplasty; Simulator; Wear

Indexed keywords

ALUMINA; BODY FLUIDS; IMPLANTS (SURGICAL); JOINTS (ANATOMY);

EID: 4344667565     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.a.30021     Document Type: Article
Times cited : (48)

References (37)
  • 1
    • 0015319816 scopus 로고
    • Arthroplastie totale de la hanche par prothese en alumine frittee
    • Boutin P. Arthroplastie totale de la hanche par prothese en alumine frittee. Revue Chirurgie Orthoped Reparat Appareil Moteur 1972;58:229-246.
    • (1972) Revue Chirurgie Orthoped Reparat Appareil Moteur , vol.58 , pp. 229-246
    • Boutin, P.1
  • 2
    • 0026761335 scopus 로고
    • On the material and the tribology of alumina-alumina couplings for hip joint prostheses
    • Walter A. On the material and the tribology of alumina-alumina couplings for hip joint prostheses. Clin Orthop Rel Res 1992;282:31-46.
    • (1992) Clin Orthop Rel Res , vol.282 , pp. 31-46
    • Walter, A.1
  • 3
    • 0012790787 scopus 로고
    • Four- to eight-year postoperative results of the partially uncemented Lindenhof-type ceramic hip endoprosthesis
    • Morscher E, editor. New York: Springer-Verlag
    • Griss P. Four- to eight-year postoperative results of the partially uncemented Lindenhof-type ceramic hip endoprosthesis. In: Morscher E, editor. The cementless fixation of hip endoprostheses. New York: Springer-Verlag; 1984. p 220-224.
    • (1984) The Cementless Fixation of Hip Endoprostheses , pp. 220-224
    • Griss, P.1
  • 4
    • 0000242627 scopus 로고    scopus 로고
    • Ex vivo and in vitro analysis of the alumina-alumina bearing system for hip joint prostheses
    • Sedel L, Rey C, editors. Cambridge: Pergamon
    • Refior HJ, Plitz W, Walter A. Ex vivo and in vitro analysis of the alumina-alumina bearing system for hip joint prostheses. In: Sedel L, Rey C, editors. Bioceramics-10. Cambridge: Pergamon: 1997. p 127-130.
    • (1997) Bioceramics-10 , pp. 127-130
    • Refior, H.J.1    Plitz, W.2    Walter, A.3
  • 5
    • 0026641524 scopus 로고
    • Sixteen years experience with ceramic hip prostheses
    • Mittelmeier H, Heisel J. Sixteen years experience with ceramic hip prostheses. Clin Orthop Rel Res 1992;282:64-72.
    • (1992) Clin Orthop Rel Res , vol.282 , pp. 64-72
    • Mittelmeier, H.1    Heisel, J.2
  • 6
    • 0025393979 scopus 로고
    • Analysis of removed autophor ceramic-on-ceramic components
    • Kummer FJ, Stuchin SA, Frankel V. Analysis of removed autophor ceramic-on-ceramic components. J Arthroplasty 1990;5:29-33.
    • (1990) J Arthroplasty , vol.5 , pp. 29-33
    • Kummer, F.J.1    Stuchin, S.A.2    Frankel, V.3
  • 7
    • 0032881955 scopus 로고    scopus 로고
    • Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses
    • Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials 1999;20:1833-1840.
    • (1999) Biomaterials , vol.20 , pp. 1833-1840
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Fisher, J.4    Nevelos, A.B.5
  • 8
    • 0026768743 scopus 로고
    • Long-term effects of alumina components in total hip prostheses
    • Dorlot JM. Long-term effects of alumina components in total hip prostheses. Clin Orthop Rel Res 1992;282:47-52.
    • (1992) Clin Orthop Rel Res , vol.282 , pp. 47-52
    • Dorlot, J.M.1
  • 10
    • 0008291702 scopus 로고    scopus 로고
    • Predicting the clinical wear performance of orthopaedic bearing surfaces
    • Jacobs J, Craig TL, editors. (ASTM STP 1346). American Society for Testing & Materials
    • Sauer WL, Anthony ME. Predicting the clinical wear performance of orthopaedic bearing surfaces. In: Jacobs J, Craig TL, editors. Alternate bearing surfaces in total joint replacement. (ASTM STP 1346). American Society for Testing & Materials; 1998.
    • (1998) Alternate Bearing Surfaces in Total Joint Replacement
    • Sauer, W.L.1    Anthony, M.E.2
  • 12
    • 13844274526 scopus 로고    scopus 로고
    • The mechanics of stripe wear formation in a modern ceramic on ceramic bearing
    • New Orleans, LA
    • Walter WL, Insley G, Walter WK, Tuke M. The mechanics of stripe wear formation in a modern ceramic on ceramic bearing. 70th Ann Mtg AAOS, New Orleans, LA, no. 278, 2003.
    • (2003) 70th Ann Mtg AAOS , vol.278
    • Walter, W.L.1    Insley, G.2    Walter, W.K.3    Tuke, M.4
  • 13
    • 0017513553 scopus 로고
    • New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminum oxide ceramic/metal
    • Semlitsch M, Lehmann M, Weber H, Doerre E, Willert G. New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminum oxide ceramic/metal. J Biomed Mater Res 1977;11:537-552.
    • (1977) J Biomed Mater Res , vol.11 , pp. 537-552
    • Semlitsch, M.1    Lehmann, M.2    Weber, H.3    Doerre, E.4    Willert, G.5
  • 14
    • 0018095631 scopus 로고
    • Investigations on tribology and strength of aluminum-oxide-ceramic-hip endoprostheses
    • Hinterberger J, Ungethum M. Investigations on tribology and strength of aluminum-oxide-ceramic-hip endoprostheses. Z Orthop 1978;116:294-303.
    • (1978) Z Orthop , vol.116 , pp. 294-303
    • Hinterberger, J.1    Ungethum, M.2
  • 15
    • 0002347650 scopus 로고
    • Wear mechanism of alumina-ceramic bearing surfaces of hip-joint prostheses
    • Ducheyne P, Van der Perre G, Aubert AE, editors. Amsterdam: Elsevier Science Pub
    • Walter A, Plitz W. Wear mechanism of alumina-ceramic bearing surfaces of hip-joint prostheses. In: Ducheyne P, Van der Perre G, Aubert AE, editors. Biomaterials and biomechanics. Amsterdam: Elsevier Science Pub; 1984. p 55-61.
    • (1984) Biomaterials and Biomechanics , pp. 55-61
    • Walter, A.1    Plitz, W.2
  • 16
    • 0002265178 scopus 로고    scopus 로고
    • Investigations on the wear couple BIOLOX forte/BIOLOX forte and earlier alumina materials
    • Stuttgart: CeramTec Inc.
    • Walter A. Investigations on the wear couple BIOLOX forte/BIOLOX forte and earlier alumina materials. In Proceedings 2nd Symp on Ceramic Wear Couple. Stuttgart: CeramTec Inc.; 1997. p 123-135.
    • (1997) Proceedings 2nd Symp on Ceramic Wear Couple , pp. 123-135
    • Walter, A.1
  • 17
    • 0041574586 scopus 로고    scopus 로고
    • Wear of alumina-on-alumina total replacement hip joints studied with a hip joint simulator
    • Stuttgart: CeramTec
    • Saikko V, Pfaff HG. Wear of alumina-on-alumina total replacement hip joints studied with a hip joint simulator. In: Proceedings 2nd Symp on Ceramic Wear Couple. Stuttgart: CeramTec; 1997. p 117-122.
    • (1997) Proceedings 2nd Symp on Ceramic Wear Couple , pp. 117-122
    • Saikko, V.1    Pfaff, H.G.2
  • 19
    • 24544446215 scopus 로고    scopus 로고
    • New wear couples for THR-simulator testing
    • Sedel L, Willmann G, editors. New York: George Thieme
    • Toni A, Affatato S. New wear couples for THR-simulator testing. In: Sedel L, Willmann G, editors. Reliability and long-term results of ceramics in orthopedics. New York: George Thieme; 1999. p 30-33.
    • (1999) Reliability and Long-Term Results of Ceramics in Orthopedics , pp. 30-33
    • Toni, A.1    Affatato, S.2
  • 21
    • 0003020289 scopus 로고    scopus 로고
    • Influence of acetabular cup angle on the wear of 'Biolox Forte' alumina/alumina hip joints in a physiological simulator
    • Anaheim, CA, February 1-4
    • Nevelos J, Ingham E, Doyle C, Fisher J. Influence of acetabular cup angle on the wear of 'Biolox Forte' alumina/alumina hip joints in a physiological simulator. In Proceedings 45th Annual Meeting of the Orthopaedic Research Society, Anaheim, CA, February 1-4, 1999. p 857.
    • (1999) Proceedings 45th Annual Meeting of the Orthopaedic Research Society , pp. 857
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3    Fisher, J.4
  • 23
    • 0035680629 scopus 로고    scopus 로고
    • Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
    • Stewart T, Tipper JL, Streicher R, Ingham E, Fisher J. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001;12:1053-1056.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 1053-1056
    • Stewart, T.1    Tipper, J.L.2    Streicher, R.3    Ingham, E.4    Fisher, J.5
  • 27
    • 0002989262 scopus 로고
    • Forces transmitted by joints in the human body
    • Paul JP. Forces transmitted by joints in the human body. Proc Inst Mech Engrs 1967;181:8-15.
    • (1967) Proc Inst Mech Engrs , vol.181 , pp. 8-15
    • Paul, J.P.1
  • 28
    • 0001825455 scopus 로고    scopus 로고
    • Comparisons of M-M and M-PE hip systems at 10 million cycles in hip simulator study
    • Rieker C, Windler M, Wyss U, editors. Bern, Germany: Han Huber
    • Clarke IC, Anissian HL, Stark A, Gustafson A, Good V, Williams P, Downs B, Yu L. Comparisons of M-M and M-PE hip systems at 10 million cycles in hip simulator study. In: Rieker C, Windler M, Wyss U, editors. Metasul: A metal-on-metal bearing. Bern, Germany: Han Huber; 1999. p 93-109.
    • (1999) Metasul: A Metal-on-Metal Bearing , pp. 93-109
    • Clarke, I.C.1    Anissian, H.L.2    Stark, A.3    Gustafson, A.4    Good, V.5    Williams, P.6    Downs, B.7    Yu, L.8
  • 29
    • 0000398086 scopus 로고
    • Friction lubrication and wear of cobalt-chromium, alumina and zirconia hip prostheses compared on a joint simulator
    • Washington, DC, February 17-20
    • McKellop H, Lu B, Benya P. Friction lubrication and wear of cobalt-chromium, alumina and zirconia hip prostheses compared on a joint simulator. In Trans 38th Ann Orthop Res Soc, Washington, DC, February 17-20, 1992. p 402.
    • (1992) Trans 38th Ann Orthop Res Soc , pp. 402
    • McKellop, H.1    Lu, B.2    Benya, P.3
  • 32
    • 0002389233 scopus 로고    scopus 로고
    • Clinical tribological performance of 144 metal-on-metal hip articulations
    • Rieker C, Windler M, Wyss U, editors. Bern, Germany: Hans Huber
    • Rieker CB, Kottig P, Schon R, Windler M, Wyss UP. Clinical tribological performance of 144 metal-on-metal hip articulations. In: Rieker C, Windler M, Wyss U, editors. METASUL: a metal on-metal bearing. Bern, Germany: Hans Huber; 1999. p 83-91.
    • (1999) METASUL: A Metal on-Metal Bearing , pp. 83-91
    • Rieker, C.B.1    Kottig, P.2    Schon, R.3    Windler, M.4    Wyss, U.P.5
  • 35
    • 4344569017 scopus 로고    scopus 로고
    • Temporomandibular joint arthroplasty: Using metal-on-metal and acrylic-on-metal configurations. Surg Technol Int VIII321-metal configurations
    • Lippincott AI, Medley JB, Dowling JM, Christensen RW. Temporomandibular joint arthroplasty: using metal-on-metal and acrylic-on-metal configurations. Surg Technol Int VIII:321-330.
    • Surg Technol Int , vol.8 , pp. 321-330
    • Lippincott, A.I.1    Medley, J.B.2    Dowling, J.M.3    Christensen, R.W.4
  • 36
    • 0033378263 scopus 로고    scopus 로고
    • Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene
    • Anissian HL, Stark A, Gustafson A, Good V, Clarke IC. Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. Acta Orthop Scand 2000;70:578-582.
    • (2000) Acta Orthop Scand , vol.70 , pp. 578-582
    • Anissian, H.L.1    Stark, A.2    Gustafson, A.3    Good, V.4    Clarke, I.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.