-
1
-
-
15044348747
-
Early results of primary Birmingham hip resurfacings
-
DOI 10.1302/0301-620X.87B3.15556
-
DL Back R Dalziel D Young A Shimmin 2005 Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips J Bone Joint Surg Br 87 324 329 10.1302/0301-620X.87B3.15556 1:STN:280:DC%2BD2M7ktFOksQ%3D%3D 15773639 (Pubitemid 40424858)
-
(2005)
Journal of Bone and Joint Surgery - Series B
, vol.87
, Issue.3
, pp. 324-329
-
-
Back, D.L.1
Dalziel, R.2
Young, D.3
Shimmin, A.4
-
3
-
-
0033855584
-
Wear debris from two different alumina-on-alumina total hip arthroplasties
-
10.1302/0301-620X.82B6.9722 1:STN:280:DC%2BD3cvkt1eksg%3D%3D 10990321
-
M Bohler Y Mochida TW Bauer H Plenk Jr M Salzer 2000 Wear debris from two different alumina-on-alumina total hip arthroplasties J Bone Joint Surg Br. 82 901 909 10.1302/0301-620X.82B6.9722 1:STN:280:DC%2BD3cvkt1eksg%3D%3D 10990321
-
(2000)
J Bone Joint Surg Br.
, vol.82
, pp. 901-909
-
-
Bohler, M.1
Mochida, Y.2
Bauer, T.W.3
Plenk Jr., H.4
Salzer, M.5
-
4
-
-
0015319816
-
Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications [in French]
-
1:STN:280:DyaE3s7itF2ntA%3D%3D 4265757
-
P Boutin 1972 Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications [in French] Rev Chir Orthop Reparatrice Appar Mot 58 229 246 1:STN:280:DyaE3s7itF2ntA%3D%3D 4265757
-
(1972)
Rev Chir Orthop Reparatrice Appar Mot
, vol.58
, pp. 229-246
-
-
Boutin, P.1
-
5
-
-
0041521572
-
Total hip arthroplasty using a ceramic prosthesis. Pierre Boutin (1924-1989)
-
10.1097/00003086-200010000-00002 11039786
-
P Boutin 2000 Total hip arthroplasty using a ceramic prosthesis. Pierre Boutin (1924-1989) Clin Orthop Relat Res 379 3 11 10.1097/00003086-200010000- 00002 11039786
-
(2000)
Clin Orthop Relat Res
, vol.379
, pp. 3-11
-
-
Boutin, P.1
-
7
-
-
0024843779
-
Wear analysis of retrieved alumina heads and sockets of hip prostheses
-
DOI 10.1002/jbm.820231405
-
JM Dorlot P Christel A Meunier 1989 Wear analysis of retrieved alumina heads and sockets of hip prostheses J Biomed Mater Res 23 Suppl 299 310 10.1002/jbm.820231405 1:CAS:528:DyaK3cXkt1Ghsg%3D%3D 2613740 (Pubitemid 20043991)
-
(1989)
Journal of Biomedical Materials Research
, vol.23
, Issue.SUPPL. A3
, pp. 299-310
-
-
Dorlot, J.-M.1
Christel, P.2
Meunier, A.3
-
11
-
-
0032877442
-
Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: A 12-year follow-up study
-
DOI 10.1016/S0883-5403(99)90025-6
-
LM Jazrawi E Bogner CJ Della Valle FS Chen KI Pak SA Stuchin VH Frankel PE Di Cesare 1999 Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: a 12-year follow-up study J Arthroplasty. 14 781 787 10.1016/S0883-5403(99)90025-6 1:STN:280:DC%2BD3c%2FgsFKnsA%3D%3D 10537250 (Pubitemid 29483242)
-
(1999)
Journal of Arthroplasty
, vol.14
, Issue.7
, pp. 781-787
-
-
Jazrawi, L.M.1
Bogner, E.2
Della Valle, C.J.3
Chen, F.S.4
Pak, K.I.5
Stuchin, S.A.6
Frankel, V.H.7
Di Cesare, P.E.8
-
12
-
-
44949094495
-
High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings
-
10.1007/s11999-008-0177-8 1:STN:280:DC%2BD1czhtlGgtw%3D%3D 18299948
-
JC Keurentjes RM Kuipers DJ Wever BW Schreurs 2008 High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings Clin Orthop Relat Res. 466 1438 1443 10.1007/s11999-008-0177-8 1:STN:280:DC%2BD1czhtlGgtw%3D%3D 18299948
-
(2008)
Clin Orthop Relat Res.
, vol.466
, pp. 1438-1443
-
-
Keurentjes, J.C.1
Kuipers, R.M.2
Wever, D.J.3
Schreurs, B.W.4
-
13
-
-
0035215635
-
Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty
-
DOI 10.1054/arth.2001.27233
-
M Morlock R Nassutt R Janssen G Willmann M Honl 2001 Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty J Arthroplasty. 16 1071 1074 10.1054/arth.2001.27233 1:STN:280: DC%2BD3MnptFyhtQ%3D%3D 11740766 (Pubitemid 33151887)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.8
, pp. 1071-1074
-
-
Morlock, M.1
Nassutt, R.2
Janssen, R.3
Willmann, G.4
Honl, M.5
-
14
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
DOI 10.1054/arth.2000.8100
-
J Nevelos E Ingham C Doyle R Streicher A Nevelos W Walter J Fisher 2000 Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns J Arthroplasty. 15 793 795 10.1054/arth.2000.8100 1:STN:280:DC%2BD3cvmsFGgsg%3D%3D 11021457 (Pubitemid 30704073)
-
(2000)
Journal of Arthroplasty
, vol.15
, Issue.6
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
Streicher, R.4
Nevelos, A.5
Walter, W.6
Fisher, J.7
-
15
-
-
35948943543
-
The squeaking hip: A cause for concern-agrees
-
17899917
-
AS Ranawat CS Ranawat 2007 The squeaking hip: a cause for concern-agrees Orthopedics. 30 738 743 17899917
-
(2007)
Orthopedics.
, vol.30
, pp. 738-743
-
-
Ranawat, A.S.1
Ranawat, C.S.2
-
16
-
-
48949118899
-
The noisy ceramic hip: Is component malpositioning the cause?
-
DOI 10.1016/j.arth.2008.04.001, PII S0883540308004403
-
C Restrepo J Parvizi SM Kurtz PF Sharkey WJ Hozack RH Rothman 2008 The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty. 23 643 649 10.1016/j.arth.2008.04.001 18655949 (Pubitemid 352004114)
-
(2008)
Journal of Arthroplasty
, vol.23
, Issue.5
, pp. 643-649
-
-
Restrepo, C.1
Parvizi, J.2
Kurtz, S.M.3
Sharkey, P.F.4
Hozack, W.J.5
Rothman, R.H.6
-
17
-
-
0033779539
-
Evolution of alumina-on-alumina implants: A review
-
10.1097/00003086-200010000-00008 11039792
-
L Sedel 2000 Evolution of alumina-on-alumina implants: a review Clin Orthop Relat Res. 379 48 54 10.1097/00003086-200010000-00008 11039792
-
(2000)
Clin Orthop Relat Res.
, vol.379
, pp. 48-54
-
-
Sedel, L.1
-
18
-
-
34848915750
-
The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings
-
DOI 10.1016/j.arth.2007.05.038, PII S088354030700318X
-
S Taylor MT Manley K Sutton 2007 The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings J Arthroplasty 22 Suppl 3 47 51 10.1016/j.arth.2007.05.038 17919593 (Pubitemid 47494618)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.SUPPL.7
, pp. 47-51
-
-
Taylor, S.1
Manley, M.T.2
Sutton, K.3
-
19
-
-
33845389612
-
Early diagnosis of ceramic liner fracture
-
A Toni F Traina S Stea A Sudanese M Visentin B Bordini S Squarzoni 2006 Early diagnosis of ceramic liner fracture Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am 88 4 55 63
-
(2006)
Guidelines Based on A Twelve-year Clinical Experience. J Bone Joint Surg Am
, vol.88
, Issue.4
, pp. 55-63
-
-
Toni, A.1
Traina, F.2
Stea, S.3
Sudanese, A.4
Visentin, M.5
Bordini, B.6
Squarzoni, S.7
-
20
-
-
2642584746
-
Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear
-
DOI 10.1016/j.arth.2003.09.018, PII S088354030400066X
-
WL Walter GM Insley WK Walter MA Tuke 2004 Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear J Arthroplasty. 19 402 413 10.1016/j.arth.2003.09.018 15188097 (Pubitemid 38725921)
-
(2004)
Journal of Arthroplasty
, vol.19
, Issue.4
, pp. 402-413
-
-
Walter, W.L.1
Insley, G.M.2
Walter, W.K.3
Tuke, M.A.4
-
21
-
-
34249933860
-
Squeaking in ceramic-on-ceramic hips. The importance of acetabular component orientation
-
DOI 10.1016/j.arth.2006.06.018, PII S0883540306005122
-
WL Walter GC O'Toole WK Walter A Ellis BA Zicat 2007 Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation J Arthroplasty. 22 496 503 10.1016/j.arth.2006.06.018 17562404 (Pubitemid 46880178)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.4
, pp. 496-503
-
-
Walter, W.L.1
O'Toole, G.C.2
Walter, W.K.3
Ellis, A.4
Zicat, B.A.5
-
22
-
-
0033781822
-
Ceramic femoral head retrieval data
-
10.1097/00003086-200010000-00004 11039788
-
G Willmann 2000 Ceramic femoral head retrieval data Clin Orthop Relat Res. 379 22 28 10.1097/00003086-200010000-00004 11039788
-
(2000)
Clin Orthop Relat Res.
, vol.379
, pp. 22-28
-
-
Willmann, G.1
-
23
-
-
38449101029
-
The squeaking hip: A cause for concern-disagrees
-
17899918
-
CC Yang RH Kim DA Dennis 2007 The squeaking hip: a cause for concern-disagrees Orthopedics. 30 739 742 17899918
-
(2007)
Orthopedics.
, vol.30
, pp. 739-742
-
-
Yang, C.C.1
Kim, R.H.2
Dennis, D.A.3
|