메뉴 건너뛰기




Volumn 22, Issue 4, 2007, Pages 496-503

Squeaking in Ceramic-on-Ceramic Hips. The Importance of Acetabular Component Orientation

Author keywords

alumina; ceramic; hip; squeak

Indexed keywords

ACETABULUM; ADULT; AGED; ARTICLE; CERAMIC PROSTHESIS; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HIP; HIP ARTHROPLASTY; HIP DISLOCATION; HUMAN; MALE; MOVEMENT (PHYSIOLOGY); POSTOPERATIVE COMPLICATION; WALKING;

EID: 34249933860     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2006.06.018     Document Type: Article
Times cited : (265)

References (20)
  • 1
    • 0015319816 scopus 로고
    • Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications
    • Boutin P. Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications. Rev Chir Orthop Reparatrice Appar Mot 58 (1972) 3
    • (1972) Rev Chir Orthop Reparatrice Appar Mot , vol.58 , pp. 3
    • Boutin, P.1
  • 2
    • 4344667565 scopus 로고    scopus 로고
    • Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model
    • Oonishi H., Clarke I.C., Good V., et al. Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model. J Biomed Mater Res A 70 (2004) 4
    • (2004) J Biomed Mater Res A , vol.70 , pp. 4
    • Oonishi, H.1    Clarke, I.C.2    Good, V.3
  • 3
    • 0035882726 scopus 로고    scopus 로고
    • Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions
    • Nevelos J.E., Ingham E., Doyle C., et al. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials 22 (2001) 16
    • (2001) Biomaterials , vol.22 , pp. 16
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3
  • 4
    • 0036056821 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study
    • Hamadouche M., Boutin P., Daussange J., et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 84-A (2002) 1
    • (2002) J Bone Joint Surg Am , vol.84 -A , pp. 1
    • Hamadouche, M.1    Boutin, P.2    Daussange, J.3
  • 5
    • 0028284420 scopus 로고
    • Charnley low-friction arthroplasty of the hip. Twenty-year results with cement
    • Kavanagh B.F., Wallrichs S., Dewitz M., et al. Charnley low-friction arthroplasty of the hip. Twenty-year results with cement. J Arthroplasty 9 (1994) 3
    • (1994) J Arthroplasty , vol.9 , pp. 3
    • Kavanagh, B.F.1    Wallrichs, S.2    Dewitz, M.3
  • 6
    • 0343969789 scopus 로고
    • Evolution of hip arthroplasty
    • Amstutz H.C. (Ed), Churchill Livingstone, New York
    • Amstutz H.C., and Clarke I.C. Evolution of hip arthroplasty. In: Amstutz H.C. (Ed). Hip arthroplasty (1991), Churchill Livingstone, New York 1
    • (1991) Hip arthroplasty , pp. 1
    • Amstutz, H.C.1    Clarke, I.C.2
  • 8
    • 0035215635 scopus 로고    scopus 로고
    • Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty
    • Morlock M., Nassutt R., Janssen R., et al. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty 16 (2001) 8
    • (2001) J Arthroplasty , vol.16 , pp. 8
    • Morlock, M.1    Nassutt, R.2    Janssen, R.3
  • 9
    • 15044348747 scopus 로고    scopus 로고
    • Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips
    • Back D.L., Dalziel R., Young D., et al. Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J Bone Joint Surg Br 87 (2005) 3
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 3
    • Back, D.L.1    Dalziel, R.2    Young, D.3
  • 10
    • 0022489328 scopus 로고
    • Anteversion of the acetabular cup. Measurement of angle after total hip replacement
    • Ackland M.K., Bourne W.B., and Uhthoff H.K. Anteversion of the acetabular cup. Measurement of angle after total hip replacement. J Bone Joint Surg Br 68 (1986) 3
    • (1986) J Bone Joint Surg Br , vol.68 , pp. 3
    • Ackland, M.K.1    Bourne, W.B.2    Uhthoff, H.K.3
  • 11
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray D.W. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75 (1993) 2
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 2
    • Murray, D.W.1
  • 12
    • 2642584746 scopus 로고    scopus 로고
    • Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear
    • Walter W.L., Insley G.M., Walter W.K., et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty 19 (2004) 4
    • (2004) J Arthroplasty , vol.19 , pp. 4
    • Walter, W.L.1    Insley, G.M.2    Walter, W.K.3
  • 15
    • 34249936190 scopus 로고
    • Dislocation after total hip arthroplasty. Causes and prevention
    • McCollum D.E., and Gray W.J. Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop (1990) 261
    • (1990) Clin Orthop , pp. 261
    • McCollum, D.E.1    Gray, W.J.2
  • 16
    • 0036220612 scopus 로고    scopus 로고
    • Comparison of a mechanical acetabular alignment guide with computer placement of the socket
    • Digioia III A.M., Jaramaz B., Plakseychuk A.Y., et al. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17 (2002) 3
    • (2002) J Arthroplasty , vol.17 , pp. 3
    • Digioia III, A.M.1    Jaramaz, B.2    Plakseychuk, A.Y.3
  • 17
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
    • Kennedy J.G., Rogers W.B., Soffe K.E., et al. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13 (1998) 5
    • (1998) J Arthroplasty , vol.13 , pp. 5
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3
  • 18
    • 0028198810 scopus 로고
    • The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis
    • Schmalzried T.P., Guttmann D., Grecula M., et al. The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg Am 76 (1994) 5
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 5
    • Schmalzried, T.P.1    Guttmann, D.2    Grecula, M.3
  • 19
    • 0242413079 scopus 로고    scopus 로고
    • Polyethylene wear and acetabular component orientation
    • Patil S., Bergula A., Chen P.C., et al. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am 85-A Suppl 4 (2003) 56
    • (2003) J Bone Joint Surg Am , vol.85 -A , Issue.SUPPL. 4 , pp. 56
    • Patil, S.1    Bergula, A.2    Chen, P.C.3
  • 20
    • 0017859205 scopus 로고
    • Dislocations after total hip-replacement arthroplasties
    • Lewinnek G.E., Lewis J.L., Tarr R., et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60 (1978) 2
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 2
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.