메뉴 건너뛰기




Volumn 80, Issue 10, 1998, Pages 1459-1468

Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; ALUMINUM; CHROMIUM; COBALT;

EID: 0031758471     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-199810000-00007     Document Type: Article
Times cited : (144)

References (51)
  • 1
    • 0026605414 scopus 로고
    • Mechanism and clinical significance of wear debris-induced osteolysis
    • Amstutz, H. C.; Campbell, P.; Kossovsky, N.; and Clarke, I. C.: Mechanism and clinical significance of wear debris-induced osteolysis. Clin. Orthop., 276: 7-18, 1992.
    • (1992) Clin. Orthop. , vol.276 , pp. 7-18
    • Amstutz, H.C.1    Campbell, P.2    Kossovsky, N.3    Clarke, I.C.4
  • 2
    • 0025047558 scopus 로고
    • Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties
    • Anthony, P. P.; Gie, G. A.; Howie, C. R.; and Ling, R. S. M.: Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J. Bone and Joint Surg., 72-B(6): 971-979, 1990.
    • (1990) J. Bone and Joint Surg. , vol.72 B , Issue.6 , pp. 971-979
    • Anthony, P.P.1    Gie, G.A.2    Howie, C.R.3    Ling, R.S.M.4
  • 3
    • 0025978596 scopus 로고
    • Osteolysis after ceramic-on-ceramic hip arthroplasty. A case report
    • Borssen, B.; Karrholm, J.; and Snorrason, F.: Osteolysis after ceramic-on-ceramic hip arthroplasty. A case report. Acta Orthop. Scandinavica, 62: 73-75, 1991.
    • (1991) Acta Orthop. Scandinavica , vol.62 , pp. 73-75
    • Borssen, B.1    Karrholm, J.2    Snorrason, F.3
  • 4
    • 0015319816 scopus 로고
    • Arthroplastic totale de la hanche par prosthèse en alumine frittée. Étude expérimentale et premières applications cliniques
    • Boutin, P.: Arthroplastic totale de la hanche par prosthèse en alumine frittée. Étude expérimentale et premières applications cliniques. Rev. chir. orthop., 58: 229-246, 1972.
    • (1972) Rev. Chir. Orthop. , vol.58 , pp. 229-246
    • Boutin, P.1
  • 5
    • 0019414342 scopus 로고
    • Le frottement alumine-alumine en chirurgie de la hanche. 1205 arthroplasties totales: Avril 1970-juin 1980
    • Boutin, P., and Blanquaert, D.: Le frottement alumine-alumine en chirurgie de la hanche. 1205 arthroplasties totales: avril 1970-juin 1980. Rev. chir. orthop., 67: 279-287, 1981.
    • (1981) Rev. Chir. Orthop. , vol.67 , pp. 279-287
    • Boutin, P.1    Blanquaert, D.2
  • 6
    • 0021992636 scopus 로고
    • Osteolytic changes in the upper femoral shaft following porous-coated hip replacement
    • Brown, I. W., and Ring, P. A.: Osteolytic changes in the upper femoral shaft following porous-coated hip replacement. J. Bone and Joint Surg., 67-B(2): 218-221, 1985.
    • (1985) J. Bone and Joint Surg. , vol.67 B , Issue.2 , pp. 218-221
    • Brown, I.W.1    Ring, P.A.2
  • 7
    • 0028267024 scopus 로고
    • The characterization of cytokines in the interface tissue obtained from failed cementless total hip arthroplasty with and without femoral osteolysis
    • Chiba, J.; Rubash, H. E.; Kim, K. J.; and Iwaki, Y.: The characterization of cytokines in the interface tissue obtained from failed cementless total hip arthroplasty with and without femoral osteolysis. Clin. Orthop., 300: 304-312, 1994.
    • (1994) Clin. Orthop. , vol.300 , pp. 304-312
    • Chiba, J.1    Rubash, H.E.2    Kim, K.J.3    Iwaki, Y.4
  • 8
    • 0026672302 scopus 로고
    • Biocompatibility of surgical-grade dense polycrystalline alumina
    • Christel, P. S.: Biocompatibility of surgical-grade dense polycrystalline alumina. Clin. Orthop., 282: 10-18, 1992.
    • (1992) Clin. Orthop. , vol.282 , pp. 10-18
    • Christel, P.S.1
  • 9
    • 0026782886 scopus 로고
    • Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings
    • Clarke, I. C.: Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings. Clin. Orthop., 282: 19-30, 1992.
    • (1992) Clin. Orthop. , vol.282 , pp. 19-30
    • Clarke, I.C.1
  • 10
    • 0022383145 scopus 로고
    • Long-term follow-up of total hip replacement in patients with osteonecrosis
    • Cornell, C. N.; Salvati, E. A.; and Pellicci, P. M.: Long-term follow-up of total hip replacement in patients with osteonecrosis. Orthop. Clin. North America, 16: 757-769, 1985.
    • (1985) Orthop. Clin. North America , vol.16 , pp. 757-769
    • Cornell, C.N.1    Salvati, E.A.2    Pellicci, P.M.3
  • 11
    • 0023240947 scopus 로고
    • Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh, C. A.; Bobyn, J. D.; and Glassman, A. H.: Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J. Bone and Joint Surg., 69-B(1): 45-55, 1987.
    • (1987) J. Bone and Joint Surg. , vol.69 B , Issue.1 , pp. 45-55
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 12
    • 1842297586 scopus 로고    scopus 로고
    • Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty
    • Feb.
    • Engh, C. A., Jr.; Culpepper, W. J., II; and Engh, C. A.: Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J. Bone and Joint Surg., 79-A: 177-184, Feb. 1997.
    • (1997) J. Bone and Joint Surg. , vol.79 A , pp. 177-184
    • Engh Jr., C.A.1    Culpepper II, W.J.2    Engh, C.A.3
  • 13
    • 0028354740 scopus 로고
    • Hip replacement with a threaded acetabular cup. A follow-up study
    • Feb.
    • Fox, G. M.; McBeath, A. A.; and Heiner, J. P.: Hip replacement with a threaded acetabular cup. A follow-up study. J. Bone and Joint Surg., 76-A: 195-201, Feb. 1994.
    • (1994) J. Bone and Joint Surg. , vol.76 A , pp. 195-201
    • Fox, G.M.1    McBeath, A.A.2    Heiner, J.P.3
  • 14
    • 0020576705 scopus 로고
    • The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
    • June
    • Goldring, S. R.; Schiller, A. L.; Roelke, M.; Rourke, C. M.; O'Neill, D. A.; and Harris, W. H.: The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J. Bone and Joint Surg., 65-A: 575-584, June 1983.
    • (1983) J. Bone and Joint Surg. , vol.65 A , pp. 575-584
    • Goldring, S.R.1    Schiller, A.L.2    Roelke, M.3    Rourke, C.M.4    O'Neill, D.A.5    Harris, W.H.6
  • 15
    • 0019406645 scopus 로고
    • Five years experience with ceramic-metal-composite hip endoprostheses. I. Clinical evaluation
    • Griss, P., and Heimke, G.: Five years experience with ceramic-metal-composite hip endoprostheses. I. Clinical evaluation. Arch. Orthop. and Traumatic Surg., 98: 157-164, 1981.
    • (1981) Arch. Orthop. and Traumatic Surg. , vol.98 , pp. 157-164
    • Griss, P.1    Heimke, G.2
  • 16
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components. A radiographic analysis of loosening
    • Gruen, T. A.; McNeice, G. M.; and Amstutz, H. C.: "Modes of failure" of cemented stem-type femoral components. A radiographic analysis of loosening. Clin. Orthop., 141: 17-27, 1979.
    • (1979) Clin. Orthop. , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 17
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • Harris, W. H.: The problem is osteolysis. Clin. Orhop., 311: 46-53, 1995.
    • (1995) Clin. Orhop. , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 18
  • 19
    • 0000530734 scopus 로고
    • Ceramic total hip replacement done without cement. Long-term follow-up study
    • Huo, M. H.; Martin, R. P.; Zatorski, L. E.; and Keggi, K. J.: Ceramic total hip replacement done without cement. Long-term follow-up study. Orthop. Trans., 19: 400-401, 1995.
    • (1995) Orthop. Trans. , vol.19 , pp. 400-401
    • Huo, M.H.1    Martin, R.P.2    Zatorski, L.E.3    Keggi, K.J.4
  • 21
    • 0001166951 scopus 로고
    • A formaldehyde-glutaraldehyde fixative of high osmolarity for use in electron microscopy
    • Karnovsky, M. J.: A formaldehyde-glutaraldehyde fixative of high osmolarity for use in electron microscopy. J. Cell Biol., 27: 137-138, 1965.
    • (1965) J. Cell Biol. , vol.27 , pp. 137-138
    • Karnovsky, M.J.1
  • 22
    • 26844473117 scopus 로고
    • Modes of failure of the threaded acetabular total hip replacement components
    • Kennedy, W. F.: Modes of failure of the threaded acetabular total hip replacement components. Orthop. Trans., 12: 691, 1988.
    • (1988) Orthop. Trans. , vol.12 , pp. 691
    • Kennedy, W.F.1
  • 23
    • 0025393979 scopus 로고
    • Analysis of removed Autophor ceramic-on-ceramic components
    • Kummer, F. J.; Stuchin, S. A.; and Frankel, V. H.: Analysis of removed Autophor ceramic-on-ceramic components. J. Arthroplasty, 5: 28-33, 1990.
    • (1990) J. Arthroplasty , vol.5 , pp. 28-33
    • Kummer, F.J.1    Stuchin, S.A.2    Frankel, V.H.3
  • 24
    • 0026597636 scopus 로고
    • Size of metallic and polyethylene debris particles in failed cemented total hip replacements
    • Lee, J.-M.; Salvati, E. A.; Betts, F.; DiCarlo, E. F.; Doty, S. B.; and Bullough, P. G.: Size of metallic and polyethylene debris particles in failed cemented total hip replacements. J. Bone and Joint Surg., 74-B(3): 380-384, 1992.
    • (1992) J. Bone and Joint Surg. , vol.74 B , Issue.3 , pp. 380-384
    • Lee, J.-M.1    Salvati, E.A.2    Betts, F.3    Dicarlo, E.F.4    Doty, S.B.5    Bullough, P.G.6
  • 25
    • 0030560987 scopus 로고    scopus 로고
    • Characterization of in vivo wear debris from ceramic-ceramic total hip arthroplasties
    • Lerouge, S.; Huk, O.; Yahia, L. H.; and Sedel, L.: Characterization of in vivo wear debris from ceramic-ceramic total hip arthroplasties. J. Biomed. Mater. Res., 32: 627-633, 1996.
    • (1996) J. Biomed. Mater. Res. , vol.32 , pp. 627-633
    • Lerouge, S.1    Huk, O.2    Yahia, L.H.3    Sedel, L.4
  • 26
    • 0025350439 scopus 로고
    • Unsatisfactory results with a ceramic total hip prosthesis
    • June
    • Mahoney, O. M., and Dimon, J. H., III: Unsatisfactory results with a ceramic total hip prosthesis. J. Bone and Joint Surg., 72-A: 663-671, June 1990.
    • (1990) J. Bone and Joint Surg. , vol.72 A , pp. 663-671
    • Mahoney, O.M.1    Dimon III, J.H.2
  • 27
    • 0029120016 scopus 로고
    • Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris
    • Sept.
    • Maloney, W. J., and Smith, R. L.: Periprosthetic osteolysis in total hip arthroplasty: the role of particulate wear debris. J. Bone and Joint Surg., 77-A: 1448-1461, Sept. 1995.
    • (1995) J. Bone and Joint Surg. , vol.77 A , pp. 1448-1461
    • Maloney, W.J.1    Smith, R.L.2
  • 28
    • 0030030188 scopus 로고    scopus 로고
    • Increasing incidence of femoral osteolysis in association with uncemented Harris-Galante total hip arthroplasty. A follow-up report
    • Maloney, W. J., and Woolson, S. T.: Increasing incidence of femoral osteolysis in association with uncemented Harris-Galante total hip arthroplasty. A follow-up report. J. Arthroplasty, 11: 130-134, 1996.
    • (1996) J. Arthroplasty , vol.11 , pp. 130-134
    • Maloney, W.J.1    Woolson, S.T.2
  • 30
    • 0027786926 scopus 로고
    • Severe osteolysis of the pelvis in association with acetabular replacement without cement
    • Nov.
    • Maloney, W. J.; Peters, P.; Engh, C. A.; and Chandler, H.: Severe osteolysis of the pelvis in association with acetabular replacement without cement. J. Bone and Joint Surg., 75-A: 1627-1635, Nov. 1993.
    • (1993) J. Bone and Joint Surg. , vol.75 A , pp. 1627-1635
    • Maloney, W.J.1    Peters, P.2    Engh, C.A.3    Chandler, H.4
  • 32
    • 0029147350 scopus 로고
    • Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement
    • Sept.
    • Maloney, W. J.; Smith, R. L.; Schmalzried, T. P.; Chiba, J.; Huene, D.; and Rubash, H.: Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. J. Bone and Joint Surg., 77-A: 1301-1310, Sept. 1995.
    • (1995) J. Bone and Joint Surg. , vol.77 A , pp. 1301-1310
    • Maloney, W.J.1    Smith, R.L.2    Schmalzried, T.P.3    Chiba, J.4    Huene, D.5    Rubash, H.6
  • 33
    • 0028076951 scopus 로고
    • Isolation and characterization of debris in membranes around total joint prostheses
    • Nov.
    • Margevicius, K. J.; Bauer, T. W.; McMahon, J. T.; Brown, S. A.; and Merritt, K.: Isolation and characterization of debris in membranes around total joint prostheses. J. Bone and Joint Surg., 76-A: 1664-1675, Nov. 1994.
    • (1994) J. Bone and Joint Surg. , vol.76 A , pp. 1664-1675
    • Margevicius, K.J.1    Bauer, T.W.2    McMahon, J.T.3    Brown, S.A.4    Merritt, K.5
  • 34
    • 0024441094 scopus 로고
    • Evaluation of cementless acetabular component migration. An experimental study
    • Massin, P.; Schmidt, L.; and Engh, C. A.: Evaluation of cementless acetabular component migration. An experimental study. J. Arthroplasty, 4: 245-251, 1989.
    • (1989) J. Arthroplasty , vol.4 , pp. 245-251
    • Massin, P.1    Schmidt, L.2    Engh, C.A.3
  • 36
    • 0026641524 scopus 로고
    • Sixteen-years' experience with ceramic hip prostheses
    • Mittelmeier, H., and Heisel, J.: Sixteen-years' experience with ceramic hip prostheses. Clin. Orthop., 282: 64-72, 1992.
    • (1992) Clin. Orthop. , vol.282 , pp. 64-72
    • Mittelmeier, H.1    Heisel, J.2
  • 37
    • 0028296206 scopus 로고
    • Osteonecrosis of the femoral head treated with total hip arthroplasty without cement
    • Feb.
    • Piston, R. W.; Engh, C. A.; De Carvalho, P. I.; and Suthers, K.: Osteonecrosis of the femoral head treated with total hip arthroplasty without cement. J. Bone and Joint Surg., 76-A: 202-214, Feb. 1994.
    • (1994) J. Bone and Joint Surg. , vol.76 A , pp. 202-214
    • Piston, R.W.1    Engh, C.A.2    De Carvalho, P.I.3    Suthers, K.4
  • 38
    • 0021254962 scopus 로고
    • Conventional total hip arthroplasty for degenerative joint disease in patients between the ages of forty and sixty years
    • June
    • Rananat, C. S.; Atkinson, R. E.; Salvati, E. A.; and Wilson, P. D., Jr.: Conventional total hip arthroplasty for degenerative joint disease in patients between the ages of forty and sixty years. J. Bone and Joint Surg., 66-A: 745-752, June 1984.
    • (1984) J. Bone and Joint Surg. , vol.66 A , pp. 745-752
    • Rananat, C.S.1    Atkinson, R.E.2    Salvati, E.A.3    Wilson Jr., P.D.4
  • 39
    • 0027131506 scopus 로고
    • Biocompatibility of polyethylene and host response to loosening of cementless total hip replacement
    • Santavirta, S.; Nordström, D.; Metsärinne, K.; and Konttinen, Y. T.: Biocompatibility of polyethylene and host response to loosening of cementless total hip replacement. Clin. Orthop., 297: 100-110, 1993.
    • (1993) Clin. Orthop. , vol.297 , pp. 100-110
    • Santavirta, S.1    Nordström, D.2    Metsärinne, K.3    Konttinen, Y.T.4
  • 41
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
    • July
    • Schmalzried, T. P.; Jasty, M.; and Harris, W. H.: Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J. Bone and Joint Surg., 74-A: 849-863, July 1992.
    • (1992) J. Bone and Joint Surg. , vol.74 A , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 43
    • 0028350371 scopus 로고
    • Localized femoral osteolysis in cementless ceramic total hip arthroplasty
    • Shih, C. H.; Wu, C. C.; Lee, Z. L.; and Yang, W. E.: Localized femoral osteolysis in cementless ceramic total hip arthroplasty. Orthop. Rev., 23: 325-328, 1994.
    • (1994) Orthop. Rev. , vol.23 , pp. 325-328
    • Shih, C.H.1    Wu, C.C.2    Lee, Z.L.3    Yang, W.E.4
  • 44
    • 0024518563 scopus 로고
    • Poor fixation of the Mittelmeier hip prosthesis. A clinical, radiographic, and scintimetric evaluation
    • Snorrason, F.; Karrholm, J.; Lowenhielm, G.; Hietala, S. O.; and Hansson, L. I.: Poor fixation of the Mittelmeier hip prosthesis. A clinical, radiographic, and scintimetric evaluation. Acta Orthop. Scandinavica, 60: 81-85, 1989.
    • (1989) Acta Orthop. Scandinavica , vol.60 , pp. 81-85
    • Snorrason, F.1    Karrholm, J.2    Lowenhielm, G.3    Hietala, S.O.4    Hansson, L.I.5
  • 45
    • 0019981269 scopus 로고
    • Ten-year follow-up study of total hip replacement. with particular reference to roentgenographic loosening of the components
    • Sept.
    • Stauffer, R. N.: Ten-year follow-up study of total hip replacement. With particular reference to roentgenographic loosening of the components. J. Bone and Joint Surg., 64-A: 983-990, Sept. 1982.
    • (1982) J. Bone and Joint Surg. , vol.64 A , pp. 983-990
    • Stauffer, R.N.1
  • 46
    • 0029044314 scopus 로고
    • Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study
    • Sugano, N.; Nishii, T.; Nakata, K.; Masuhara, K.; and Takaoka, K.: Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study. J. Bone and Joint Surg., 77-B(4): 548-556, 1995.
    • (1995) J. Bone and Joint Surg. , vol.77 B , Issue.4 , pp. 548-556
    • Sugano, N.1    Nishii, T.2    Nakata, K.3    Masuhara, K.4    Takaoka, K.5
  • 47
    • 0026718908 scopus 로고
    • The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement
    • March
    • Tanzer, M.; Maloney, W. J.; Jasty, M.; and Harris, W. H.: The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement. J. Bone and Joint Surg., 74-A: 404-410, March 1992.
    • (1992) J. Bone and Joint Surg. , vol.74 A , pp. 404-410
    • Tanzer, M.1    Maloney, W.J.2    Jasty, M.3    Harris, W.H.4
  • 48
    • 0026761335 scopus 로고
    • On the material and the tribology of alumina-alumina couplings for hip joint prostheses
    • Walter, I. A.: On the material and the tribology of alumina-alumina couplings for hip joint prostheses. Clin. Orthop., 282: 31-46, 1992.
    • (1992) Clin. Orthop. , vol.282 , pp. 31-46
    • Walter, I.A.1
  • 49
    • 0026782887 scopus 로고
    • Ten- to 14-year results of a ceramic hip prosthesis
    • Winter, M.; Griss, P.; Scheller, G.; and Moser, T.: Ten- to 14-year results of a ceramic hip prosthesis. Clin. Orthop., 282: 73-80, 1992.
    • (1992) Clin. Orthop. , vol.282 , pp. 73-80
    • Winter, M.1    Griss, P.2    Scheller, G.3    Moser, T.4
  • 50
    • 0028956936 scopus 로고
    • Patterns of osteolysis around total hip components inserted with and without cement
    • March
    • Zicat, B.; Engh, C. A.; and Gokcen, E.: Patterns of osteolysis around total hip components inserted with and without cement. J. Bone and Joint Surg., 77-A: 432-439, March 1995.
    • (1995) J. Bone and Joint Surg. , vol.77 A , pp. 432-439
    • Zicat, B.1    Engh, C.A.2    Gokcen, E.3
  • 51
    • 0026782890 scopus 로고
    • Comparison of alumina-polyethylene and metal-polyethylene in clinical trials
    • Zichner, L. P., and Willert, H.-G.: Comparison of alumina-polyethylene and metal-polyethylene in clinical trials. Clin. Orthop., 282: 86-94, 1992.
    • (1992) Clin. Orthop. , vol.282 , pp. 86-94
    • Zichner, L.P.1    Willert, H.-G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.