-
1
-
-
84882518864
-
-
NIH Consensus Statement: Total Hip Replacement. National Institutes of Health Technology Assessment Conference, 1994 September 12-14.
-
NIH Consensus Statement: Total Hip Replacement. National Institutes of Health Technology Assessment Conference, 1994 September 12-14.
-
-
-
-
2
-
-
0026132108
-
Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads
-
Harris WH Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads. J Bone Joint Surg Am 1991, 73(3):470-472.
-
(1991)
J Bone Joint Surg Am
, vol.73
, Issue.3
, pp. 470-472
-
-
Harris, W.H.1
-
3
-
-
0028325196
-
Osteolysis and particle disease in hip replacement
-
Harris WH Osteolysis and particle disease in hip replacement. Acta Orthop Scand 1994, 65(1):113-123.
-
(1994)
Acta Orthop Scand
, vol.65
, Issue.1
, pp. 113-123
-
-
Harris, W.H.1
-
4
-
-
0026784175
-
Osteolysis after total knee arthroplasty without cement
-
Peters PC, Engh GA, Dwyer KA, Vinh TN Osteolysis after total knee arthroplasty without cement. J Bone Joint Surg Am 1992, 74(6):864-876.
-
(1992)
J Bone Joint Surg Am
, vol.74
, Issue.6
, pp. 864-876
-
-
Peters, P.C.1
Engh, G.A.2
Dwyer, K.A.3
Vinh, T.N.4
-
5
-
-
0028198810
-
The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis
-
Schmalzried TP, Guttmann D, Grecula M, Amstutz HC The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg Am 1994, 76(5):677-688.
-
(1994)
J Bone Joint Surg Am
, vol.76
, Issue.5
, pp. 677-688
-
-
Schmalzried, T.P.1
Guttmann, D.2
Grecula, M.3
Amstutz, H.C.4
-
6
-
-
0025254587
-
Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation
-
Willert HG, Bertram H, Buchhorn GH Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation. Clin Orthop Relat Res 1990, (258):108-121.
-
(1990)
Clin Orthop Relat Res
, Issue.258
, pp. 108-121
-
-
Willert, H.G.1
Bertram, H.2
Buchhorn, G.H.3
-
7
-
-
0033641059
-
Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements
-
Clarke IC, Good V, Williams P, Schroeder D, Anissian L, Stark A, et al. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng [H] 2000, 214(4):331-347.
-
(2000)
Proc Inst Mech Eng [H]
, vol.214
, Issue.4
, pp. 331-347
-
-
Clarke, I.C.1
Good, V.2
Williams, P.3
Schroeder, D.4
Anissian, L.5
Stark, A.6
-
8
-
-
37349127412
-
The 2007 Otto Aufranc Award. Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study
-
Williams S, Schepers A, Isaac G, Hardaker C, Ingham E, van der Jagt D, et al. The 2007 Otto Aufranc Award. Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study. Clin Orthop Relat Res 2007, 465:23-32.
-
(2007)
Clin Orthop Relat Res
, vol.465
, pp. 23-32
-
-
Williams, S.1
Schepers, A.2
Isaac, G.3
Hardaker, C.4
Ingham, E.5
Van Der Jagt, D.6
-
9
-
-
3042792714
-
The use of primary total hip arthroplasty in university hospitals of the European Union
-
Scheerlinck T, Druyts P, Casteleyn PP The use of primary total hip arthroplasty in university hospitals of the European Union. Acta Orthop Belg 2004, 70(3):231-239.
-
(2004)
Acta Orthop Belg
, vol.70
, Issue.3
, pp. 231-239
-
-
Scheerlinck, T.1
Druyts, P.2
Casteleyn, P.P.3
-
10
-
-
84882531331
-
-
Australian Orthopaedic Association National Joint Replacement Registry. Annual report. 2008 [cited September 21, 2008]. Available from:
-
Australian Orthopaedic Association National Joint Replacement Registry. Annual report. 2008 [cited September 21, 2008]. Available from: . http://www.dmac.adelaide.edu.au/aoanjrr/publications.jsp.
-
-
-
-
11
-
-
84882549145
-
Hospital resources and implant cost management-a 2007 update
-
Mendenhall S Hospital resources and implant cost management-a 2007 update. Orthop Network News 2008, 19(3):13-19.
-
(2008)
Orthop Network News
, vol.19
, Issue.3
, pp. 13-19
-
-
Mendenhall, S.1
-
12
-
-
52049114010
-
Future young patient demand for primary and revision joint replacement: National projections from 2010 to 2030
-
Kurtz S, Lau E, Ong K, Zhao K, Kelly M, Bozic K Future young patient demand for primary and revision joint replacement: National projections from 2010 to 2030. Trans of the 54th Orthop Res Soc 2008, 33:1784.
-
(2008)
Trans of the 54th Orthop Res Soc
, vol.33
, pp. 1784
-
-
Kurtz, S.1
Lau, E.2
Ong, K.3
Zhao, K.4
Kelly, M.5
Bozic, K.6
-
13
-
-
0008291702
-
Predicting the clinical wear performance of orthopaedic bearing surfaces
-
American Society for Testing and Materials, West Conshohoken, J.J. Jacobs, T.L. Craig (Eds.)
-
Sauer WL, Anthony ME Predicting the clinical wear performance of orthopaedic bearing surfaces. Alternative bearing surfaces in total joint replacement 1998, 1-29. American Society for Testing and Materials, West Conshohoken. J.J. Jacobs, T.L. Craig (Eds.).
-
(1998)
Alternative bearing surfaces in total joint replacement
, pp. 1-29
-
-
Sauer, W.L.1
Anthony, M.E.2
-
15
-
-
33747872580
-
Evolution of mould arthroplasty of the hip joint
-
Smith-Petersen MN Evolution of mould arthroplasty of the hip joint. J Bone Joint Br 1948, 30-B(1):59-75.
-
(1948)
J Bone Joint Br
, Issue.1
, pp. 59-75
-
-
Smith-petersen, M.N.1
-
16
-
-
20644451143
-
Metals and Alloys
-
W.B. Saunders Company, Philaldelphia, W. Petty (Ed.)
-
Lemons JE Metals and Alloys. Total joint replacement 1991, 21-27. W.B. Saunders Company, Philaldelphia. W. Petty (Ed.).
-
(1991)
Total joint replacement
, pp. 21-27
-
-
Lemons, J.E.1
-
17
-
-
0032605637
-
A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements
-
Dearnley PA A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements. Proc Inst Mech Eng [H] 1999, 213(2):107-135.
-
(1999)
Proc Inst Mech Eng [H]
, vol.213
, Issue.2
, pp. 107-135
-
-
Dearnley, P.A.1
-
18
-
-
0000612954
-
Metallic biomaterials
-
CRC Press LLC, Boca Raton, FL, J.D. Bronzino (Ed.)
-
Park JB Metallic biomaterials. The biomedical engineering handbook 1995, 537-551. CRC Press LLC, Boca Raton, FL. J.D. Bronzino (Ed.).
-
(1995)
The biomedical engineering handbook
, pp. 537-551
-
-
Park, J.B.1
-
19
-
-
11744255289
-
Co-Cr-Mo alloys used in metal-metal bearing surfaces
-
American Society for Testing and Materials, West Conshohoken, J.J. Jacobs, T.L. Craig (Eds.)
-
Varano R, Yue S, Bobyn JD, Medley J Co-Cr-Mo alloys used in metal-metal bearing surfaces. Alternative bearing surfaces in total joint replacement 1998, 55-68. American Society for Testing and Materials, West Conshohoken. J.J. Jacobs, T.L. Craig (Eds.).
-
(1998)
Alternative bearing surfaces in total joint replacement
, pp. 55-68
-
-
Varano, R.1
Yue, S.2
Bobyn, J.D.3
Medley, J.4
-
20
-
-
33645239883
-
'Severe' wear challenge to 'as-cast' and 'double heat-treated' large-diameter metal-on-metal hip bearings
-
Bowsher JG, Nevelos J, Williams PA, Shelton JC 'Severe' wear challenge to 'as-cast' and 'double heat-treated' large-diameter metal-on-metal hip bearings. Proc Inst Mech Eng [H] 2006, 220:135-143.
-
(2006)
Proc Inst Mech Eng [H]
, vol.220
, pp. 135-143
-
-
Bowsher, J.G.1
Nevelos, J.2
Williams, P.A.3
Shelton, J.C.4
-
21
-
-
9644287859
-
A hip joint simulator study of the performance of metal-on-metal joints. Part I: the role of materials
-
Dowson D, Hardaker C, Flett M, Isaac GH A hip joint simulator study of the performance of metal-on-metal joints. Part I: the role of materials. J Arthroplasty 2004, 19(Suppl 3):118-123.
-
(2004)
J Arthroplasty
, vol.19
, Issue.SUPPL.3
, pp. 118-123
-
-
Dowson, D.1
Hardaker, C.2
Flett, M.3
Isaac, G.H.4
-
22
-
-
33645219347
-
Metal-on-metal bearing surfaces: materials, manufacture, design, optimization, and alternatives
-
Isaac GH, Thompson J, Williams S, Fisher J Metal-on-metal bearing surfaces: materials, manufacture, design, optimization, and alternatives. Proc Inst Mech Eng [H] 2006, 220:119-133.
-
(2006)
Proc Inst Mech Eng [H]
, vol.220
, pp. 119-133
-
-
Isaac, G.H.1
Thompson, J.2
Williams, S.3
Fisher, J.4
-
23
-
-
0029809897
-
Metal on metal total hip replacement workshop consensus document
-
Amstutz HC, Campbell P, McKellop H, Schmalzreid TP, Gillespie WJ, Howie D, et al. Metal on metal total hip replacement workshop consensus document. Clin Orthop 1996, 329(329 Suppl):S297-303.
-
(1996)
Clin Orthop
, vol.329
, Issue.329 SUPPL
-
-
Amstutz, H.C.1
Campbell, P.2
McKellop, H.3
Schmalzreid, T.P.4
Gillespie, W.J.5
Howie, D.6
-
24
-
-
0032949430
-
Analysis of 118 second-generation metal-on-metal retrieved hip implants
-
Sieber HP, Rieker CB, Kottig P Analysis of 118 second-generation metal-on-metal retrieved hip implants. J Bone Joint Surg Br 1999, 81(1):46-50.
-
(1999)
J Bone Joint Surg Br
, vol.81
, Issue.1
, pp. 46-50
-
-
Sieber, H.P.1
Rieker, C.B.2
Kottig, P.3
-
25
-
-
14844309776
-
Retrieval studies on classic cemented metal-on-metal hip endoprostheses
-
Hans Huber, Bern, C.B. Rieker, M. Windler, U. Wyss (Eds.)
-
Willert HG, Buchhorn GH Retrieval studies on classic cemented metal-on-metal hip endoprostheses. Metasul: a metal-on-metal bearing 1999, 39-60. Hans Huber, Bern. C.B. Rieker, M. Windler, U. Wyss (Eds.).
-
(1999)
Metasul: a metal-on-metal bearing
, pp. 39-60
-
-
Willert, H.G.1
Buchhorn, G.H.2
-
26
-
-
0029790088
-
Surface geometry of retrieved McKee-Farrar total hip replacements
-
Kothari M, Bartel DL, Booker JF Surface geometry of retrieved McKee-Farrar total hip replacements. Clin Orthop 1996, 329(329 Suppl):S141-147.
-
(1996)
Clin Orthop
, vol.329
, Issue.329 SUPPL
-
-
Kothari, M.1
Bartel, D.L.2
Booker, J.F.3
-
27
-
-
0029831455
-
In vivo wear of three types of metal on metal hip prostheses during two decades of use
-
McKellop H, Park SH, Chiesa R, Doorn P, Lu B, Normand P, et al. In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clin Orthop 1996, 329(329 Suppl):S128-140.
-
(1996)
Clin Orthop
, vol.329
, Issue.329 SUPPL
-
-
McKellop, H.1
Park, S.H.2
Chiesa, R.3
Doorn, P.4
Lu, B.5
Normand, P.6
-
28
-
-
0032881955
-
Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses
-
Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials 1999, 20(19):1833-1840.
-
(1999)
Biomaterials
, vol.20
, Issue.19
, pp. 1833-1840
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Fisher, J.4
Nevelos, A.B.5
-
29
-
-
84924645601
-
The surgery of the osteo-arthritic hip
-
Wiles P The surgery of the osteo-arthritic hip. Br J Surg 1957, 45:488-497.
-
(1957)
Br J Surg
, vol.45
, pp. 488-497
-
-
Wiles, P.1
-
30
-
-
0013912485
-
Replacement of arthritic hips by the McKee-Farrar prosthesis
-
McKee GK, Watson-Farrar J Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg [Br] 1966, 48(2):245-259.
-
(1966)
J Bone Joint Surg [Br]
, vol.48
, Issue.2
, pp. 245-259
-
-
McKee, G.K.1
Watson-farrar, J.2
-
31
-
-
0014349395
-
Complete replacement arthroplasty of the hip by the ring prosthesis
-
Ring PA Complete replacement arthroplasty of the hip by the ring prosthesis. J Bone Joint Surg Br 1968, 50(4):720-731.
-
(1968)
J Bone Joint Surg Br
, vol.50
, Issue.4
, pp. 720-731
-
-
Ring, P.A.1
-
32
-
-
0032932612
-
Lessons learned from loosening of the McKee-Farrar metal-on-metal total hip replacement
-
Zahiri CA, Schmalzried TP, Ebramzadeh E, Szuszczewicz ES, Salib D, Kim C, et al. Lessons learned from loosening of the McKee-Farrar metal-on-metal total hip replacement. J Arthroplasty 1999, 14(3):326-332.
-
(1999)
J Arthroplasty
, vol.14
, Issue.3
, pp. 326-332
-
-
Zahiri, C.A.1
Schmalzried, T.P.2
Ebramzadeh, E.3
Szuszczewicz, E.S.4
Salib, D.5
Kim, C.6
-
33
-
-
0017462028
-
Reactions of the articular capsule to wear products of artificial joint prostheses
-
Willert HG Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 1977, 11(2):157-164.
-
(1977)
J Biomed Mater Res
, vol.11
, Issue.2
, pp. 157-164
-
-
Willert, H.G.1
-
34
-
-
0029790389
-
Wear behavior and histopathology of classic cemented metal on metal hip endoprostheses
-
Willert HG, Buchhorn GH, Gobel D, Koster G, Schaffner S, Schenk R, et al. Wear behavior and histopathology of classic cemented metal on metal hip endoprostheses. Clin Orthop Relat Res 1996, (329 Suppl):S160-186.
-
(1996)
Clin Orthop Relat Res
, Issue.329 SUPPL
-
-
Willert, H.G.1
Buchhorn, G.H.2
Gobel, D.3
Koster, G.4
Schaffner, S.5
Schenk, R.6
-
36
-
-
0029817370
-
Cobalt and chromium concentrations in patients with metal on metal total hip replacements
-
Jacobs JJ, Skipor AK, Doorn PF, Campbell P, Schmalzried TP, Black J, et al. Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin Orthop 1996, 329(329 Suppl):S256-263.
-
(1996)
Clin Orthop
, vol.329
, Issue.329 SUPPL
-
-
Jacobs, J.J.1
Skipor, A.K.2
Doorn, P.F.3
Campbell, P.4
Schmalzried, T.P.5
Black, J.6
-
37
-
-
0028887583
-
The benefits of metal-on-metal total hip replacements
-
Muller ME The benefits of metal-on-metal total hip replacements. Clin Orthop 1995, 311(311):54-59.
-
(1995)
Clin Orthop
, vol.311
, Issue.311
, pp. 54-59
-
-
Muller, M.E.1
-
39
-
-
0025349263
-
A comparative study between McKee-Farrar and Charnley arthroplasty with long-term follow-up periods
-
Jacobsson SA, Djerf K, Wahlstrom O A comparative study between McKee-Farrar and Charnley arthroplasty with long-term follow-up periods. J Arthroplasty 1990, 5(1):9-14.
-
(1990)
J Arthroplasty
, vol.5
, Issue.1
, pp. 9-14
-
-
Jacobsson, S.A.1
Djerf, K.2
Wahlstrom, O.3
-
40
-
-
0029790388
-
Twenty-year results of McKee-Farrar versus Charnley prosthesis
-
Jacobsson SA, Djerf K, Wahlstrom O Twenty-year results of McKee-Farrar versus Charnley prosthesis. Clin Orthop 1996, (329 Suppl):S60-68.
-
(1996)
Clin Orthop
, Issue.329 SUPPL
-
-
Jacobsson, S.A.1
Djerf, K.2
Wahlstrom, O.3
-
41
-
-
0033779480
-
Medium-term results of a modern metal-on-metal system in total hip replacement
-
Wagner M, Wagner H Medium-term results of a modern metal-on-metal system in total hip replacement. Clin Orthop 2000, (379):123-133.
-
(2000)
Clin Orthop
, Issue.379
, pp. 123-133
-
-
Wagner, M.1
Wagner, H.2
-
42
-
-
0029788857
-
Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty
-
Wagner M, Wagner H Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty. Clin Orthop 1996, 329(329 Suppl):S78-88.
-
(1996)
Clin Orthop
, vol.329
, Issue.329 SUPPL
-
-
Wagner, M.1
Wagner, H.2
-
43
-
-
0013166853
-
METASUL from 1988 to today
-
Hans Huber, Bern, C.B. Rieker, M. Windler, U. Wyss (Eds.)
-
Weber BG METASUL from 1988 to today. Metasul: a metal-on-metal bearing 1999, 23-28. Hans Huber, Bern. C.B. Rieker, M. Windler, U. Wyss (Eds.).
-
(1999)
Metasul: a metal-on-metal bearing
, pp. 23-28
-
-
Weber, B.G.1
-
44
-
-
0029813457
-
Cobalt chromium molybdenum metal combination for modular hip prostheses
-
Schmidt M, Weber H, Schon R Cobalt chromium molybdenum metal combination for modular hip prostheses. Clin Orthop 1996, 329(329 Suppl):S35-47.
-
(1996)
Clin Orthop
, vol.329
, Issue.329 SUPPL
-
-
Schmidt, M.1
Weber, H.2
Schon, R.3
-
45
-
-
14844312531
-
Development of the METASUL articulations
-
Hans Huber, Bern, C.B. Rieker, M. Windler, U. Wyss (Eds.)
-
Rieker CB, Weber H, Schön R, Windler M, Wyss U Development of the METASUL articulations. Metasul: a metal-on-metal bearing 1999, 15-21. Hans Huber, Bern. C.B. Rieker, M. Windler, U. Wyss (Eds.).
-
(1999)
Metasul: a metal-on-metal bearing
, pp. 15-21
-
-
Rieker, C.B.1
Weber, H.2
Schön, R.3
Windler, M.4
Wyss, U.5
-
46
-
-
33645217473
-
Background of metal-on-metal resurfacing
-
Amstutz HC, Le Duff MJ Background of metal-on-metal resurfacing. Proc Inst Mech Eng [H] 2006, 220(2):85-94.
-
(2006)
Proc Inst Mech Eng [H]
, vol.220
, Issue.2
, pp. 85-94
-
-
Amstutz, H.C.1
Le Duff, M.J.2
-
47
-
-
17044388967
-
Current concepts of metal-on-metal hip resurfacing
-
viii
-
Clarke IC, Donaldson T, Bowsher JG, Nasser S, Takahashi T Current concepts of metal-on-metal hip resurfacing. Orthop Clin North Am 2005, 36(2):143-162. viii.
-
(2005)
Orthop Clin North Am
, vol.36
, Issue.2
, pp. 143-162
-
-
Clarke, I.C.1
Donaldson, T.2
Bowsher, J.G.3
Nasser, S.4
Takahashi, T.5
-
48
-
-
33645218204
-
History and modern concepts in surface replacement
-
McMinn D, Daniel J History and modern concepts in surface replacement. Proc Inst Mech Eng [H] 2006, 220(2):239-251.
-
(2006)
Proc Inst Mech Eng [H]
, vol.220
, Issue.2
, pp. 239-251
-
-
McMinn, D.1
Daniel, J.2
-
49
-
-
0036396324
-
The swedish total hip replacement register
-
Malchau H, Herberts P, Eisler T, Garellick G, Soderman P The swedish total hip replacement register. J Bone Joint Surg Am 2002, 84-A(Suppl 2):2-20.
-
(2002)
J Bone Joint Surg Am
, Issue.SUPPL.2
, pp. 2-20
-
-
Malchau, H.1
Herberts, P.2
Eisler, T.3
Garellick, G.4
Soderman, P.5
-
50
-
-
84882551435
-
-
The epidemiology of revision total hip arthroplasty in the United States. 18th annual meeting of the American association of hip and knee surgeons, Dallas, TX: 2008.
-
Bozic KJ, Kurtz S, Lau E, Ong K, Vail T, Berry D. The epidemiology of revision total hip arthroplasty in the United States. 18th annual meeting of the American association of hip and knee surgeons, Dallas, TX: 2008.
-
-
-
Bozic, K.J.1
Kurtz, S.2
Lau, E.3
Ong, K.4
Vail, T.5
Berry, D.6
-
51
-
-
0037270870
-
Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacement
-
Phillips CB, Barrett JA, Losina E, Mahomed NN, Lingard EA, Guadagnoli E, et al. Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacement. J Bone Joint Surg Am 2003, 85-A(1):20-26.
-
(2003)
J Bone Joint Surg Am
, Issue.1
, pp. 20-26
-
-
Phillips, C.B.1
Barrett, J.A.2
Losina, E.3
Mahomed, N.N.4
Lingard, E.A.5
Guadagnoli, E.6
-
52
-
-
0348223830
-
Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study
-
Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg Am 2004, 86-A(1):28-39.
-
(2004)
J Bone Joint Surg Am
, Issue.1
, pp. 28-39
-
-
Amstutz, H.C.1
Beaule, P.E.2
Dorey, F.J.3
Le Duff, M.J.4
Campbell, P.A.5
Gruen, T.A.6
-
53
-
-
33750356310
-
Hip resurfacing arthroplasty
-
Mont MA, Ragland PS, Etienne G, Seyler TM, Schmalzried TP Hip resurfacing arthroplasty. J Am Acad Orthop Surg 2006, 14(8):454-463.
-
(2006)
J Am Acad Orthop Surg
, vol.14
, Issue.8
, pp. 454-463
-
-
Mont, M.A.1
Ragland, P.S.2
Etienne, G.3
Seyler, T.M.4
Schmalzried, T.P.5
-
54
-
-
84882533085
-
-
National Joint Registry. National Joint Registry for England and Wales: 4th Annual report, 2007.
-
National Joint Registry. National Joint Registry for England and Wales: 4th Annual report, 2007.
-
-
-
-
55
-
-
31144476645
-
Notching of the femoral neck during resurfacing arthroplasty of the hip: a vascular study
-
Beaule PE, Campbell PA, Hoke R, Dorey F Notching of the femoral neck during resurfacing arthroplasty of the hip: a vascular study. J Bone Joint Surg Br 2006, 88(1):35-39.
-
(2006)
J Bone Joint Surg Br
, vol.88
, Issue.1
, pp. 35-39
-
-
Beaule, P.E.1
Campbell, P.A.2
Hoke, R.3
Dorey, F.4
-
56
-
-
17744365971
-
Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases
-
Shimmin AJ, Back D Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br 2005, 87(4):463-464.
-
(2005)
J Bone Joint Surg Br
, vol.87
, Issue.4
, pp. 463-464
-
-
Shimmin, A.J.1
Back, D.2
-
57
-
-
33644787865
-
Optimizing patient selection and outcomes with total hip resurfacing
-
Schmalzried TP, Silva M, de la Rosa MA, Choi ES, Fowble VA Optimizing patient selection and outcomes with total hip resurfacing. Clin Orthop Relat Res 2005, 441:200-204.
-
(2005)
Clin Orthop Relat Res
, vol.441
, pp. 200-204
-
-
Schmalzried, T.P.1
Silva, M.2
De La Rosa, M.A.3
Choi, E.S.4
Fowble, V.A.5
-
58
-
-
33645232552
-
Lessons learned from early clinical experience and results of 300 ASR hip resurfacing implantations
-
Siebel T, Maubach S, Morlock MM Lessons learned from early clinical experience and results of 300 ASR hip resurfacing implantations. Proc Inst Mech Eng [H] 2006, 220(2):345-353.
-
(2006)
Proc Inst Mech Eng [H]
, vol.220
, Issue.2
, pp. 345-353
-
-
Siebel, T.1
Maubach, S.2
Morlock, M.M.3
-
59
-
-
33846853331
-
The femoral head/neck offset and hip resurfacing
-
Beaule PE, Harvey N, Zaragoza E, Le Duff MJ, Dorey FJ The femoral head/neck offset and hip resurfacing. J Bone Joint Surg Br 2007, 89(1):9-15.
-
(2007)
J Bone Joint Surg Br
, vol.89
, Issue.1
, pp. 9-15
-
-
Beaule, P.E.1
Harvey, N.2
Zaragoza, E.3
Le Duff, M.J.4
Dorey, F.J.5
-
60
-
-
0347594037
-
The biomechanical results of total hip resurfacing arthroplasty
-
Silva M, Lee KH, Heisel C, Dela Rosa MA, Schmalzried TP The biomechanical results of total hip resurfacing arthroplasty. J Bone Joint Surg Am 2004, 86-A(1):40-46.
-
(2004)
J Bone Joint Surg Am
, Issue.1
, pp. 40-46
-
-
Silva, M.1
Lee, K.H.2
Heisel, C.3
Dela Rosa, M.A.4
Schmalzried, T.P.5
-
61
-
-
33845445598
-
Surgical variables affect the mechanics of a hip resurfacing system
-
Long JP, Bartel DL Surgical variables affect the mechanics of a hip resurfacing system. Clin Orthop Relat Res 2006, 453:115-122.
-
(2006)
Clin Orthop Relat Res
, vol.453
, pp. 115-122
-
-
Long, J.P.1
Bartel, D.L.2
-
62
-
-
59149095455
-
Role of surgical position on interface stress and initial bone remodeling stimulus around hip resurfacing arthroplasty
-
in press
-
Ong KL, Day JS, Kurtz SM, Field RE, Manley MT Role of surgical position on interface stress and initial bone remodeling stimulus around hip resurfacing arthroplasty. J Arthroplasty 2008, in press.
-
(2008)
J Arthroplasty
-
-
Ong, K.L.1
Day, J.S.2
Kurtz, S.M.3
Field, R.E.4
Manley, M.T.5
-
63
-
-
49849102239
-
Have contemporary hip resurfacing designs reached maturity? A review
-
Ong KL, Manley MT, Kurtz SM Have contemporary hip resurfacing designs reached maturity? A review. J Bone Joint Surg Am 2008, 90(Suppl 3):81-88.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL.3
, pp. 81-88
-
-
Ong, K.L.1
Manley, M.T.2
Kurtz, S.M.3
-
65
-
-
0035045395
-
Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
-
Firkins PJ, Tipper JL, Saadatzadeh MR, Ingham E, Stone MH, Farrar R, et al. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 2001, 11(2):143-157.
-
(2001)
Biomed Mater Eng
, vol.11
, Issue.2
, pp. 143-157
-
-
Firkins, P.J.1
Tipper, J.L.2
Saadatzadeh, M.R.3
Ingham, E.4
Stone, M.H.5
Farrar, R.6
-
66
-
-
0032190304
-
Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles
-
Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 1998, 42(1):103-111.
-
(1998)
J Biomed Mater Res
, vol.42
, Issue.1
, pp. 103-111
-
-
Doorn, P.F.1
Campbell, P.A.2
Worrall, J.3
Benya, P.D.4
McKellop, H.A.5
Amstutz, H.C.6
-
67
-
-
67649466103
-
Particle disease in metal-on-metal total hip replacements
-
Hans Huber, Bern, C.B. Rieker, M. Windler, U. Wyss (Eds.)
-
Doorn PF, Campbell P, Amstutz H Particle disease in metal-on-metal total hip replacements. Metasul: a metal-on-metal bearing 1999, 113-119. Hans Huber, Bern. C.B. Rieker, M. Windler, U. Wyss (Eds.).
-
(1999)
Metasul: a metal-on-metal bearing
, pp. 113-119
-
-
Doorn, P.F.1
Campbell, P.2
Amstutz, H.3
-
68
-
-
0005188756
-
Wear particle morphologies in artificial hip joints: Particle size is critical to the response of macrophages
-
Hans Huber, Bern, C.B. Rieker, M. Windler, U. Wyss (Eds.)
-
Fisher J, Ingham E, Stone M, Wroblewski BM, Besong AA, Tipper JL, et al. Wear particle morphologies in artificial hip joints: Particle size is critical to the response of macrophages. Metasul: a metal-on-metal bearing 1999, 121-124. Hans Huber, Bern. C.B. Rieker, M. Windler, U. Wyss (Eds.).
-
(1999)
Metasul: a metal-on-metal bearing
, pp. 121-124
-
-
Fisher, J.1
Ingham, E.2
Stone, M.3
Wroblewski, B.M.4
Besong, A.A.5
Tipper, J.L.6
-
69
-
-
0031727764
-
Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
-
Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 1998, 80(10):1447-1458.
-
(1998)
J Bone Joint Surg Am
, vol.80
, Issue.10
, pp. 1447-1458
-
-
Jacobs, J.J.1
Skipor, A.K.2
Patterson, L.M.3
Hallab, N.J.4
Paprosky, W.G.5
Black, J.6
-
70
-
-
14844301723
-
Metallic wear and corrosion products: biological implications
-
Hans Huber, Bern, C.B. Rieker, M. Windler, U. Wyss (Eds.)
-
Jacobs JJ, Hallab NJ, Skipor AK, Urban RM, Mikecz K, Glant TT Metallic wear and corrosion products: biological implications. Metasul: a metal-on-metal bearing 1999, 125-132. Hans Huber, Bern. C.B. Rieker, M. Windler, U. Wyss (Eds.).
-
(1999)
Metasul: a metal-on-metal bearing
, pp. 125-132
-
-
Jacobs, J.J.1
Hallab, N.J.2
Skipor, A.K.3
Urban, R.M.4
Mikecz, K.5
Glant, T.T.6
-
71
-
-
0030905094
-
Elevated serum cobalt with metal-on-metal articulating surfaces
-
Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R Elevated serum cobalt with metal-on-metal articulating surfaces. J Bone Joint Surg Br 1997, 79(2):316-321.
-
(1997)
J Bone Joint Surg Br
, vol.79
, Issue.2
, pp. 316-321
-
-
Brodner, W.1
Bitzan, P.2
Meisinger, V.3
Kaider, A.4
Gottsauner-wolf, F.5
Kotz, R.6
-
72
-
-
0029789979
-
Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty
-
Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin Orthop 1996, 329(329 Suppl):S280-189.
-
(1996)
Clin Orthop
, vol.329
, Issue.329 SUPPL
-
-
Visuri, T.1
Pukkala, E.2
Paavolainen, P.3
Pulkkinen, P.4
Riska, E.B.5
-
73
-
-
84882539932
-
Hypersensitivity to wear products in metal-on-metal articulation
-
Steinkopff Verlag, Darmstadt, H. Zippel, M. Dietrich (Eds.)
-
Willert HG, Buchhorn GH, Fayyazi A Hypersensitivity to wear products in metal-on-metal articulation. Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings 2003, 65-72. Steinkopff Verlag, Darmstadt. H. Zippel, M. Dietrich (Eds.).
-
(2003)
Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings
, pp. 65-72
-
-
Willert, H.G.1
Buchhorn, G.H.2
Fayyazi, A.3
-
74
-
-
0035108321
-
Metal sensitivity in patients with orthopaedic implants
-
Hallab N, Merritt K, Jacobs JJ Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 2001, 83-A(3):428-436.
-
(2001)
J Bone Joint Surg Am
, Issue.3
, pp. 428-436
-
-
Hallab, N.1
Merritt, K.2
Jacobs, J.J.3
-
75
-
-
53649088948
-
Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components
-
De Haan R, Campbell PA, Su EP, De Smet KA Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br 2008, 90(9):1158-1163.
-
(2008)
J Bone Joint Surg Br
, vol.90
, Issue.9
, pp. 1158-1163
-
-
De Haan, R.1
Campbell, P.A.2
Su, E.P.3
De Smet, K.A.4
-
76
-
-
53849111555
-
Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
-
De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet KA Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br 2008, 90(10):1291-1297.
-
(2008)
J Bone Joint Surg Br
, vol.90
, Issue.10
, pp. 1291-1297
-
-
De Haan, R.1
Pattyn, C.2
Gill, H.S.3
Murray, D.W.4
Campbell, P.A.5
De Smet, K.A.6
-
77
-
-
49849095334
-
Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position
-
Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. J Bone Joint Surg Am 2008, 90(Suppl 3):111-117.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL.3
, pp. 111-117
-
-
Williams, S.1
Leslie, I.2
Isaac, G.3
Jin, Z.4
Ingham, E.5
Fisher, J.6
-
78
-
-
33644947539
-
A benign psoas mass following metal-on-metal resurfacing of the hip
-
Boardman DR, Middleton FR, Kavanagh TG A benign psoas mass following metal-on-metal resurfacing of the hip. J Bone Joint Surg Br 2006, 88(3):402-404.
-
(2006)
J Bone Joint Surg Br
, vol.88
, Issue.3
, pp. 402-404
-
-
Boardman, D.R.1
Middleton, F.R.2
Kavanagh, T.G.3
-
79
-
-
51349129697
-
Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip. A case report
-
Clayton RA, Beggs I, Salter DM, Grant MH, Patton JT, Porter DE Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip. A case report. J Bone Joint Surg Am 2008, 90(9):1988-1993.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.9
, pp. 1988-1993
-
-
Clayton, R.A.1
Beggs, I.2
Salter, D.M.3
Grant, M.H.4
Patton, J.T.5
Porter, D.E.6
-
80
-
-
11844305550
-
An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements
-
Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg Am 2005, 87(1):18-27.
-
(2005)
J Bone Joint Surg Am
, vol.87
, Issue.1
, pp. 18-27
-
-
Davies, A.P.1
Willert, H.G.2
Campbell, P.A.3
Learmonth, I.D.4
Case, C.P.5
-
81
-
-
34548439304
-
Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty
-
Gruber FW, Bock A, Trattnig S, Lintner F, Ritschl P Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty. J Arthroplasty 2007, 22(6):923-927.
-
(2007)
J Arthroplasty
, vol.22
, Issue.6
, pp. 923-927
-
-
Gruber, F.W.1
Bock, A.2
Trattnig, S.3
Lintner, F.4
Ritschl, P.5
-
82
-
-
47549111326
-
Pseudotumours associated with metal-on-metal hip resurfacings
-
Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br 2008, 90(7):847-851.
-
(2008)
J Bone Joint Surg Br
, vol.90
, Issue.7
, pp. 847-851
-
-
Pandit, H.1
Glyn-jones, S.2
McLardy-smith, P.3
Gundle, R.4
Whitwell, D.5
Gibbons, C.L.6
-
84
-
-
11844293972
-
Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study
-
Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 2005, 87(1):28-36.
-
(2005)
J Bone Joint Surg Am
, vol.87
, Issue.1
, pp. 28-36
-
-
Willert, H.G.1
Buchhorn, G.H.2
Fayyazi, A.3
Flury, R.4
Windler, M.5
Koster, G.6
-
85
-
-
21444450339
-
Early osteolysis following second-generation metal-on-metal hip replacement
-
Park YS, Moon YW, Lim SJ, Yang JM, Ahn G, Choi YL Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am 2005, 87(7):1515-1521.
-
(2005)
J Bone Joint Surg Am
, vol.87
, Issue.7
, pp. 1515-1521
-
-
Park, Y.S.1
Moon, Y.W.2
Lim, S.J.3
Yang, J.M.4
Ahn, G.5
Choi, Y.L.6
-
86
-
-
0015233325
-
[Alumina and its use in surgery of the hip. (Experimental study)]
-
Boutin P [Alumina and its use in surgery of the hip. (Experimental study)]. Presse Med 1971, 79(14):639-640.
-
(1971)
Presse Med
, vol.79
, Issue.14
, pp. 639-640
-
-
Boutin, P.1
-
87
-
-
0015319816
-
[Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]
-
Boutin P [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]. Rev Chir Orthop Reparatrice Appar Mot 1972, 58(3):229-246.
-
(1972)
Rev Chir Orthop Reparatrice Appar Mot
, vol.58
, Issue.3
, pp. 229-246
-
-
Boutin, P.1
-
89
-
-
11844255625
-
Ceramics in total hip replacement
-
Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L Ceramics in total hip replacement. Clin Orthop Relat Res 2005, (430):62-71.
-
(2005)
Clin Orthop Relat Res
, Issue.430
, pp. 62-71
-
-
Hannouche, D.1
Hamadouche, M.2
Nizard, R.3
Bizot, P.4
Meunier, A.5
Sedel, L.6
-
90
-
-
0025295098
-
Alumina-on-alumina hip replacement. Results and survivorship in young patients
-
Sedel L, Kerboull L, Christel P, Meunier A, Witvoet J Alumina-on-alumina hip replacement. Results and survivorship in young patients. J Bone Joint Surg Br 1990, 72(4):658-663.
-
(1990)
J Bone Joint Surg Br
, vol.72
, Issue.4
, pp. 658-663
-
-
Sedel, L.1
Kerboull, L.2
Christel, P.3
Meunier, A.4
Witvoet, J.5
-
91
-
-
0021667373
-
Ceramic prosthetic devices
-
Mittelmeier H Ceramic prosthetic devices. Hip 1984, 146-160.
-
(1984)
Hip
, pp. 146-160
-
-
Mittelmeier, H.1
-
92
-
-
0026782887
-
Ten- to 14-year results of a ceramic hip prosthesis
-
Winter M, Griss P, Scheller G, Moser T Ten- to 14-year results of a ceramic hip prosthesis. Clin Orthop 1992, (282):73-80.
-
(1992)
Clin Orthop
, Issue.282
, pp. 73-80
-
-
Winter, M.1
Griss, P.2
Scheller, G.3
Moser, T.4
-
93
-
-
0025350439
-
Unsatisfactory results with a ceramic total hip prosthesis
-
Mahoney OM, Dimon JH Unsatisfactory results with a ceramic total hip prosthesis. J Bone Joint Surg Am 1990, 72(5):663-671.
-
(1990)
J Bone Joint Surg Am
, vol.72
, Issue.5
, pp. 663-671
-
-
Mahoney, O.M.1
Dimon, J.H.2
-
94
-
-
0032877442
-
Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: a 12-year follow-up study
-
Jazrawi LM, Bogner E, Della Valle CJ, Chen FS, Pak KI, Stuchin SA, et al. Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: a 12-year follow-up study. J Arthroplasty 1999, 14(7):781-787.
-
(1999)
J Arthroplasty
, vol.14
, Issue.7
, pp. 781-787
-
-
Jazrawi, L.M.1
Bogner, E.2
Della Valle, C.J.3
Chen, F.S.4
Pak, K.I.5
Stuchin, S.A.6
-
95
-
-
0024843779
-
Wear analysis of retrieved alumina heads and sockets of hip prostheses
-
A3 SUPPL
-
Dorlot JM, Christel P, Meunier A Wear analysis of retrieved alumina heads and sockets of hip prostheses. J Biomed Mater Res 1989, 23(A3 Suppl):299-310.
-
(1989)
J Biomed Mater Res
, vol.23
, pp. 299-310
-
-
Dorlot, J.M.1
Christel, P.2
Meunier, A.3
-
96
-
-
0034572680
-
Ceramic/ceramic total hip arthroplasty
-
Bizot P, Nizard R, Lerouge S, Prudhommeaux F, Sedel L Ceramic/ceramic total hip arthroplasty. J Orthop Sci 2000, 5(6):622-627.
-
(2000)
J Orthop Sci
, vol.5
, Issue.6
, pp. 622-627
-
-
Bizot, P.1
Nizard, R.2
Lerouge, S.3
Prudhommeaux, F.4
Sedel, L.5
-
97
-
-
0027711949
-
Examination of alumina ceramic components from total hip arthroplasties
-
Nevelos AB, Evans PA, Harrison P, Rainforth M Examination of alumina ceramic components from total hip arthroplasties. Proc Inst Mech Eng [H] 1993, 207(3):155-162.
-
(1993)
Proc Inst Mech Eng [H]
, vol.207
, Issue.3
, pp. 155-162
-
-
Nevelos, A.B.1
Evans, P.A.2
Harrison, P.3
Rainforth, M.4
-
98
-
-
0033781825
-
Alumina ceramic bearings for hip endoprostheses: the Austrian experiences
-
Boehler M, Plenk H., Salzer M. Alumina ceramic bearings for hip endoprostheses: the Austrian experiences. Clin Orthop 2000, 379(379):85-93.
-
(2000)
Clin Orthop
, vol.379
, Issue.379
, pp. 85-93
-
-
Boehler, M.1
Plenk, H.2
Salzer, M.3
-
99
-
-
0031940455
-
Ceramics for total hip replacement-what a surgeon should know
-
Willmann G Ceramics for total hip replacement-what a surgeon should know. Orthopedics 1998, 21(2):173-177.
-
(1998)
Orthopedics
, vol.21
, Issue.2
, pp. 173-177
-
-
Willmann, G.1
-
100
-
-
0033781822
-
Ceramic femoral head retrieval data
-
Willmann G Ceramic femoral head retrieval data. Clin Orthop 2000, 379(379):22-28.
-
(2000)
Clin Orthop
, vol.379
, Issue.379
, pp. 22-28
-
-
Willmann, G.1
-
101
-
-
33644785953
-
Next generation ceramic bearings
-
Steinkopff Verlag, Darmstadt, H. Zippel, M. Dietrich (Eds.)
-
Merkert P Next generation ceramic bearings. Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings 2003, 123-125. Steinkopff Verlag, Darmstadt. H. Zippel, M. Dietrich (Eds.).
-
(2003)
Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings
, pp. 123-125
-
-
Merkert, P.1
-
102
-
-
84882501078
-
Quality improvement resulting from legal and regulatory developments
-
Steinkopff Verlag, Darmstadt, H. Zippel, M. Dietrich (Eds.)
-
Dobbs H Quality improvement resulting from legal and regulatory developments. Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings 2003, 205-208. Steinkopff Verlag, Darmstadt. H. Zippel, M. Dietrich (Eds.).
-
(2003)
Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings
, pp. 205-208
-
-
Dobbs, H.1
-
103
-
-
84882481495
-
Improvements in processing and manufacturing at CeramTec
-
Steinkopff Verlag, Darmstadt, H. Zippel, M. Dietrich (Eds.)
-
Griesmayr G, Dietrich M, Kasprowitsch J, Dobbs H Improvements in processing and manufacturing at CeramTec. Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings 2003, 209-214. Steinkopff Verlag, Darmstadt. H. Zippel, M. Dietrich (Eds.).
-
(2003)
Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings
, pp. 209-214
-
-
Griesmayr, G.1
Dietrich, M.2
Kasprowitsch, J.3
Dobbs, H.4
-
104
-
-
84855525469
-
Influence of resting periods on friction in artificial hip joint articulations
-
Thieme, Stuttgart, J.P. Garino, G. Willmann (Eds.)
-
Morlock M, Nassutt R, Wimmer MA, Schneider E Influence of resting periods on friction in artificial hip joint articulations. Bioceramics in joint arthroplasty, Proceedings of the 7th international BIOLOX symposium 2002, 6-20. Thieme, Stuttgart. J.P. Garino, G. Willmann (Eds.).
-
(2002)
Bioceramics in joint arthroplasty, Proceedings of the 7th international BIOLOX symposium
, pp. 6-20
-
-
Morlock, M.1
Nassutt, R.2
Wimmer, M.A.3
Schneider, E.4
-
105
-
-
1642274204
-
Fiction and facts concerning the reliability of ceramics in THR
-
Steinkopff Verlag, Darmstadt, H. Zippel, M. Dietrich (Eds.)
-
Willmann G Fiction and facts concerning the reliability of ceramics in THR. Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings 2003, 193-196. Steinkopff Verlag, Darmstadt. H. Zippel, M. Dietrich (Eds.).
-
(2003)
Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings
, pp. 193-196
-
-
Willmann, G.1
-
106
-
-
84882484362
-
-
Personal communication. CeramTec; 2008.
-
Heros R. Personal communication. CeramTec; 2008.
-
-
-
Heros, R.1
-
107
-
-
0032917811
-
Zirconia as a ceramic biomaterial
-
Piconi C, Maccauro G Zirconia as a ceramic biomaterial. Bio-materials 1999, 20(1):1-25.
-
(1999)
Bio-materials
, vol.20
, Issue.1
, pp. 1-25
-
-
Piconi, C.1
Maccauro, G.2
-
108
-
-
0033771089
-
Zirconia as a sliding material: histologic, laboratory, and clinical data
-
Cales B Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop 2000, 379(379):94-112.
-
(2000)
Clin Orthop
, vol.379
, Issue.379
, pp. 94-112
-
-
Cales, B.1
-
109
-
-
10744222195
-
Current status of zirconia used in total hip implants
-
Clarke IC, Manaka M, Green DD, Williams P, Pezzotti G, Kim YH, et al. Current status of zirconia used in total hip implants. J Bone Joint Surg Am 2003, 85-A(Suppl 4):73-84.
-
(2003)
J Bone Joint Surg Am
, Issue.SUPPL.4
, pp. 73-84
-
-
Clarke, I.C.1
Manaka, M.2
Green, D.D.3
Williams, P.4
Pezzotti, G.5
Kim, Y.H.6
-
110
-
-
84882555857
-
-
Information on breakages reported on Prozyr femoral heads: Key dates. : St. Gobain, Desmarquest; 2002 (accessed: 28.04.03).
-
Information on breakages reported on Prozyr femoral heads: Key dates. : St. Gobain, Desmarquest; 2002 (accessed: 28.04.03). http://wwwprozyrcom/PAGES_UK/Biomedical/historichtm.
-
-
-
-
111
-
-
84882492957
-
-
Recall of Zirconia Ceramic Femoral Heads for Hip Implants. : United States Food and Drug Administration; 2001 (accessed: 28.04.03).
-
Recall of Zirconia Ceramic Femoral Heads for Hip Implants. : United States Food and Drug Administration; 2001 (accessed: 28.04.03). http://wwwfdagov/cdrh/recalls/zirconiahiphtml.
-
-
-
-
113
-
-
33745713085
-
Advanced nanocomposite materials for orthopaedic applications. I. A long-term in vitro wear study of zirconia-toughened alumina
-
Affatato S, Torrecillas R, Taddei P, Rocchi M, Fagnano C, Ciapetti G, et al. Advanced nanocomposite materials for orthopaedic applications. I. A long-term in vitro wear study of zirconia-toughened alumina. J Biomed Mater Res B Appl Biomater 2006, 78(1):76-82.
-
(2006)
J Biomed Mater Res B Appl Biomater
, vol.78
, Issue.1
, pp. 76-82
-
-
Affatato, S.1
Torrecillas, R.2
Taddei, P.3
Rocchi, M.4
Fagnano, C.5
Ciapetti, G.6
-
114
-
-
44449110244
-
Clinical applications of oxidized zirconium
-
Sheth NP, Lementowski P, Hunter G, Garino JP Clinical applications of oxidized zirconium. J Surg Orthop Adv 2008, 17(1):17-26.
-
(2008)
J Surg Orthop Adv
, vol.17
, Issue.1
, pp. 17-26
-
-
Sheth, N.P.1
Lementowski, P.2
Hunter, G.3
Garino, J.P.4
-
115
-
-
33644814678
-
Arthroplasty options for the young patient: Oxinium on cross-linked polyethylene
-
Bourne RB, Barrack R, Rorabeck CH, Salehi A, Good V Arthroplasty options for the young patient: Oxinium on cross-linked polyethylene. Clin Orthop Relat Res 2005, 441:159-167.
-
(2005)
Clin Orthop Relat Res
, vol.441
, pp. 159-167
-
-
Bourne, R.B.1
Barrack, R.2
Rorabeck, C.H.3
Salehi, A.4
Good, V.5
-
116
-
-
0242606961
-
Reduced wear with oxidized zirconium femoral heads
-
Good V, Ries M, Barrack RL, Widding K, Hunter G, Heuer D Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg Am 2003, 85-A(Suppl 4):105-110.
-
(2003)
J Bone Joint Surg Am
, Issue.SUPPL.4
, pp. 105-110
-
-
Good, V.1
Ries, M.2
Barrack, R.L.3
Widding, K.4
Hunter, G.5
Heuer, D.6
-
117
-
-
33845372894
-
Low wear with high-crosslinked polyethylene especially in combination with oxinium heads. A RSA evaluation
-
Li MG, Zhou ZK, Wood DJ, Rohrl SM, Ioppolo JL, Nivbrant B Low wear with high-crosslinked polyethylene especially in combination with oxinium heads. A RSA evaluation. Trans of the 52nd Orthop Res Soc 2006, 31:643.
-
(2006)
Trans of the 52nd Orthop Res Soc
, vol.31
, pp. 643
-
-
Li, M.G.1
Zhou, Z.K.2
Wood, D.J.3
Rohrl, S.M.4
Ioppolo, J.L.5
Nivbrant, B.6
-
118
-
-
8644241678
-
Oxidized zirconium femoral components reduce polyethylene wear in a knee wwear simulator
-
Ezzet KA, Hermida JC, Colwell CW, D'Lima DD Oxidized zirconium femoral components reduce polyethylene wear in a knee wwear simulator. Clin Orthop Relat Res 2004, (428):120-124.
-
(2004)
Clin Orthop Relat Res
, Issue.428
, pp. 120-124
-
-
Ezzet, K.A.1
Hermida, J.C.2
Colwell, C.W.3
D'Lima, D.D.4
-
119
-
-
34249788974
-
Surface damage to an Oxinium femoral head prosthesis after dislocation
-
Evangelista GT, Fulkerson E, Kummer F, Di Cesare PE Surface damage to an Oxinium femoral head prosthesis after dislocation. J Bone Joint Surg Br 2007, 89(4):535-537.
-
(2007)
J Bone Joint Surg Br
, vol.89
, Issue.4
, pp. 535-537
-
-
Evangelista, G.T.1
Fulkerson, E.2
Kummer, F.3
Di Cesare, P.E.4
-
120
-
-
34547572936
-
Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies
-
Kop AM, Whitewood C, Johnston DJ Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies. J Arthroplasty 2007, 22(5):775-779.
-
(2007)
J Arthroplasty
, vol.22
, Issue.5
, pp. 775-779
-
-
Kop, A.M.1
Whitewood, C.2
Johnston, D.J.3
-
121
-
-
84882521334
-
Fabrication and testing of silicon nitride bearings in total hip arthroplasty winner of the 2007 quot;HAP quot; PAUL award
-
Bal BS, Khandkar A, Lakshminarayanan R, Clarke I, Hoffman AA, Rahaman MN Fabrication and testing of silicon nitride bearings in total hip arthroplasty winner of the 2007 "HAP" PAUL award. J Arthroplasty 2008.
-
(2008)
J Arthroplasty
-
-
Bal, B.S.1
Khandkar, A.2
Lakshminarayanan, R.3
Clarke, I.4
Hoffman, A.A.5
Rahaman, M.N.6
-
122
-
-
55049119972
-
Testing of silicon nitride ceramic bearings for total hip arthroplasty
-
Bal BS, Khandkar A, Lakshminarayanan R, Clarke I, Hoffman AA, Rahaman MN Testing of silicon nitride ceramic bearings for total hip arthroplasty. J Biomed Mater Res B Appl Biomater 2008.
-
(2008)
J Biomed Mater Res B Appl Biomater
-
-
Bal, B.S.1
Khandkar, A.2
Lakshminarayanan, R.3
Clarke, I.4
Hoffman, A.A.5
Rahaman, M.N.6
-
123
-
-
44949216567
-
On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part II: chemical stability and wear resistance in body environment
-
Mazzocchi M, Gardini D, Traverso PL, Faga MG, Bellosi A On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part II: chemical stability and wear resistance in body environment. J Mater Sci Mater Med 2008, 19(8):2889-2901.
-
(2008)
J Mater Sci Mater Med
, vol.19
, Issue.8
, pp. 2889-2901
-
-
Mazzocchi, M.1
Gardini, D.2
Traverso, P.L.3
Faga, M.G.4
Bellosi, A.5
-
124
-
-
46549084094
-
On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part I: processing, microstructure, mechanical properties, cytotoxicity
-
Mazzocchi M, Bellosi A On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part I: processing, microstructure, mechanical properties, cytotoxicity. J Mater Sci Mater Med 2008, 19(8):2881-2887.
-
(2008)
J Mater Sci Mater Med
, vol.19
, Issue.8
, pp. 2881-2887
-
-
Mazzocchi, M.1
Bellosi, A.2
-
125
-
-
0030634935
-
The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement
-
Lancaster JG, Dowson D, Isaac GH, Fisher J The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Proc Inst Mech Eng [H] 1997, 211(1):17-24.
-
(1997)
Proc Inst Mech Eng [H]
, vol.211
, Issue.1
, pp. 17-24
-
-
Lancaster, J.G.1
Dowson, D.2
Isaac, G.H.3
Fisher, J.4
-
126
-
-
0029033367
-
Femoral head technologies to reduce polyethylene wear in total hip arthroplasty
-
Cuckler JM, Bearcroft J, Asgian CM Femoral head technologies to reduce polyethylene wear in total hip arthroplasty. Clin Orthop 1995, 317(317):57-63.
-
(1995)
Clin Orthop
, vol.317
, Issue.317
, pp. 57-63
-
-
Cuckler, J.M.1
Bearcroft, J.2
Asgian, C.M.3
-
127
-
-
0029044314
-
Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study
-
Sugano N, Nishii T, Nakata K, Masuhara K, Takaoka K Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study. J Bone Joint Surg Br 1995, 77(4):548-556.
-
(1995)
J Bone Joint Surg Br
, vol.77
, Issue.4
, pp. 548-556
-
-
Sugano, N.1
Nishii, T.2
Nakata, K.3
Masuhara, K.4
Takaoka, K.5
-
128
-
-
0036023527
-
A literature review of the association between wear rate and osteolysis in total hip arthroplasty
-
Dumbleton JH, Manley MT, Edidin AA A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 2002, 17(5):649-661.
-
(2002)
J Arthroplasty
, vol.17
, Issue.5
, pp. 649-661
-
-
Dumbleton, J.H.1
Manley, M.T.2
Edidin, A.A.3
-
129
-
-
23044447438
-
Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study
-
Kim YH Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study. J Bone Joint Surg Am 2005, 87(8):1769-1776.
-
(2005)
J Bone Joint Surg Am
, vol.87
, Issue.8
, pp. 1769-1776
-
-
Kim, Y.H.1
-
130
-
-
33845445105
-
Zirconia versus Co-Cr femoral heads in total hip arthroplasty: early assessment of wear
-
Kraay MJ, Thomas RD, Rimnac CM, Fitzgerald SJ, Goldberg VM Zirconia versus Co-Cr femoral heads in total hip arthroplasty: early assessment of wear. Clin Orthop Relat Res 2006, 453:86-90.
-
(2006)
Clin Orthop Relat Res
, vol.453
, pp. 86-90
-
-
Kraay, M.J.1
Thomas, R.D.2
Rimnac, C.M.3
Fitzgerald, S.J.4
Goldberg, V.M.5
-
131
-
-
0038441585
-
Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up
-
Hernigou P, Bahrami T Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up. J Bone Joint Surg Br 2003, 85(4):504-509.
-
(2003)
J Bone Joint Surg Br
, vol.85
, Issue.4
, pp. 504-509
-
-
Hernigou, P.1
Bahrami, T.2
-
132
-
-
0033835923
-
Comparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads
-
Sychterz CJ, Engh CA, Young AM, Hopper RH, Engh CA Comparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads. J Bone Joint Surg Br 2000, 82(7):948-951.
-
(2000)
J Bone Joint Surg Br
, vol.82
, Issue.7
, pp. 948-951
-
-
Sychterz, C.J.1
Engh, C.A.2
Young, A.M.3
Hopper, R.H.4
Engh, C.A.5
-
133
-
-
84882468053
-
Wear performance of 28 millimeter femoral heads with the Harris-Galante cup: Comparison of alumina and cobalt chrome
-
Steinkopff Verlag, Darmstadt, H. Zippel, M. Dietrich (Eds.)
-
Hendrich C, Goebel S, Roller C, Kirschner S, Martell JM Wear performance of 28 millimeter femoral heads with the Harris-Galante cup: Comparison of alumina and cobalt chrome. Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings 2003, 177-182. Steinkopff Verlag, Darmstadt. H. Zippel, M. Dietrich (Eds.).
-
(2003)
Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings
, pp. 177-182
-
-
Hendrich, C.1
Goebel, S.2
Roller, C.3
Kirschner, S.4
Martell, J.M.5
-
134
-
-
9644276743
-
The pros and cons of polyethylene sterilization with gamma irradiation
-
Hopper RH, Engh CA, Fowlkes LB, Engh CA. The pros and cons of polyethylene sterilization with gamma irradiation. Clin Orthop Relat Res 2004, (429):54-62.
-
(2004)
Clin Orthop Relat Res
, Issue.429
, pp. 54-62
-
-
Hopper, R.H.1
Engh, C.A.2
Fowlkes, L.B.3
Engh, C.A.4
-
135
-
-
84882517737
-
-
Personal communication. AORI; 2008.
-
Hopper Jr RH. Personal communication. AORI; 2008.
-
-
-
Hopper Jr, R.H.1
-
136
-
-
0034525710
-
Comparison of migration in modular sockets with ceramic and polyethylene inlays
-
Bohler M, Schachinger W, Wolfl G, Krismer M, Mayr G, Salzer M Comparison of migration in modular sockets with ceramic and polyethylene inlays. Orthopedics 2000, 23(12):1261-1266.
-
(2000)
Orthopedics
, vol.23
, Issue.12
, pp. 1261-1266
-
-
Bohler, M.1
Schachinger, W.2
Wolfl, G.3
Krismer, M.4
Mayr, G.5
Salzer, M.6
-
137
-
-
84941902055
-
Migration patterns of press-fit cups with polyethylene or alumina liner-A randomized clinical trial using radiostereoanalysis
-
Thieme, Stuttgart, J.P. Garino, G. Willmann (Eds.)
-
Schwämmlein D, Schmidt R, Schikora N, Graef B, Willmann G, Holzwarth U, et al. Migration patterns of press-fit cups with polyethylene or alumina liner-A randomized clinical trial using radiostereoanalysis. Bioceramics in joint arthroplasty, Proceedings of the 7th international BIOLOX symposium 2002, 81-85. Thieme, Stuttgart. J.P. Garino, G. Willmann (Eds.).
-
(2002)
Bioceramics in joint arthroplasty, Proceedings of the 7th international BIOLOX symposium
, pp. 81-85
-
-
Schwämmlein, D.1
Schmidt, R.2
Schikora, N.3
Graef, B.4
Willmann, G.5
Holzwarth, U.6
-
138
-
-
69949086313
-
Extremely high fracture rate of a modular acetabular component with a sandwich polyethylene ceramic insertion for THA: a preliminary report
-
Kircher J, Bader R, Schroeder B, Mittelmeier W Extremely high fracture rate of a modular acetabular component with a sandwich polyethylene ceramic insertion for THA: a preliminary report. Arch Orthop Trauma Surg 2008.
-
(2008)
Arch Orthop Trauma Surg
-
-
Kircher, J.1
Bader, R.2
Schroeder, B.3
Mittelmeier, W.4
-
139
-
-
48449094844
-
Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup
-
Popescu D, Gallart X, Garcia S, Bori G, Tomas X, Riba J Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup. Arch Orthop Trauma Surg 2008, 128(8):783-785.
-
(2008)
Arch Orthop Trauma Surg
, vol.128
, Issue.8
, pp. 783-785
-
-
Popescu, D.1
Gallart, X.2
Garcia, S.3
Bori, G.4
Tomas, X.5
Riba, J.6
-
140
-
-
33846850269
-
Failure analysis of a ceramic bearing acetabular component
-
Poggie RA, Turgeon TR, Coutts RD Failure analysis of a ceramic bearing acetabular component. J Bone Joint Surg Am 2007, 89(2):367-375.
-
(2007)
J Bone Joint Surg Am
, vol.89
, Issue.2
, pp. 367-375
-
-
Poggie, R.A.1
Turgeon, T.R.2
Coutts, R.D.3
-
141
-
-
34247847840
-
Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty
-
Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res 2007, 458:106-110.
-
(2007)
Clin Orthop Relat Res
, vol.458
, pp. 106-110
-
-
Ha, Y.C.1
Kim, S.Y.2
Kim, H.J.3
Yoo, J.J.4
Koo, K.H.5
-
142
-
-
33644794333
-
A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results
-
D'Antonio JA, Capello WN, Manley MT, Naughton M, Sutton K A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results. Clin Orthop Relat Res 2005, 441:151-158.
-
(2005)
Clin Orthop Relat Res
, vol.441
, pp. 151-158
-
-
D'Antonio, J.A.1
Capello, W.N.2
Manley, M.T.3
Naughton, M.4
Sutton, K.5
-
143
-
-
49549083952
-
Wear performance of large-diameter differential-hardness hip bearings
-
Barnes CL, DeBoer D, Corpe RS, Nambu S, Carroll M, Timmerman I Wear performance of large-diameter differential-hardness hip bearings. J Arthroplasty 2008, 23(6 Suppl 1):56-60.
-
(2008)
J Arthroplasty
, vol.23
, Issue.6 SUPPL.1
, pp. 56-60
-
-
Barnes, C.L.1
DeBoer, D.2
Corpe, R.S.3
Nambu, S.4
Carroll, M.5
Timmerman, I.6
-
144
-
-
33749468806
-
Severe cobalt poisoning with loss of sight after ceramic-metal pairing in a hip-a case report
-
Steens W, von Foerster G, Katzer A Severe cobalt poisoning with loss of sight after ceramic-metal pairing in a hip-a case report. Acta Orthop 2006, 77(5):830-832.
-
(2006)
Acta Orthop
, vol.77
, Issue.5
, pp. 830-832
-
-
Steens, W.1
Von Foerster, G.2
Katzer, A.3
-
145
-
-
34548430872
-
Catastrophic wear in a metal-on-ceramic total hip arthroplasty
-
Valenti JR, Del Rio J, Amillo S Catastrophic wear in a metal-on-ceramic total hip arthroplasty. J Arthroplasty 2007, 22(6):920-922.
-
(2007)
J Arthroplasty
, vol.22
, Issue.6
, pp. 920-922
-
-
Valenti, J.R.1
Del Rio, J.2
Amillo, S.3
-
146
-
-
2642584746
-
Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear
-
Walter WL, Insley GM, Walter WK, Tuke MA Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty 2004, 19(4):402-413.
-
(2004)
J Arthroplasty
, vol.19
, Issue.4
, pp. 402-413
-
-
Walter, W.L.1
Insley, G.M.2
Walter, W.K.3
Tuke, M.A.4
-
147
-
-
55649088197
-
Osteolysis in Third-Generation Alumina Ceramic-on-Ceramic Hip Bearings With Severe Impingement and Titanium Metallosis
-
Murali R, Bonar SF, Kirsh G, Walter WK, Walter WL Osteolysis in Third-Generation Alumina Ceramic-on-Ceramic Hip Bearings With Severe Impingement and Titanium Metallosis. J Arthroplasty 2008.
-
(2008)
J Arthroplasty
-
-
Murali, R.1
Bonar, S.F.2
Kirsh, G.3
Walter, W.K.4
Walter, W.L.5
-
149
-
-
44049107492
-
Ceramic total hip arthroplasty in the United States: safety and risk issues revisited
-
Tateiwa T, Clarke IC, Williams PA, Garino J, Manaka M, Shishido T, et al. Ceramic total hip arthroplasty in the United States: safety and risk issues revisited. Am J Orthop 2008, 37(2):E26-31.
-
(2008)
Am J Orthop
, vol.37
, Issue.2
-
-
Tateiwa, T.1
Clarke, I.C.2
Williams, P.A.3
Garino, J.4
Manaka, M.5
Shishido, T.6
-
150
-
-
21844437667
-
Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study
-
D'Antonio J, Capello W, Manley M, Naughton M, Sutton K Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res 2005, (436):164-171.
-
(2005)
Clin Orthop Relat Res
, Issue.436
, pp. 164-171
-
-
D'Antonio, J.1
Capello, W.2
Manley, M.3
Naughton, M.4
Sutton, K.5
-
151
-
-
84882500617
-
-
Information on breakages reported on Prozyr femoral heads: Batches & product configurations concerned by breakages. : St. Gobain, Desmarquest; 2003 (accessed: 28.04.03).
-
Information on breakages reported on Prozyr femoral heads: Batches & product configurations concerned by breakages. : St. Gobain, Desmarquest; 2003 (accessed: 28.04.03). http://wwwprozyrcom/PAGES_UK/Biomedical/breakageshtm.
-
-
-
-
152
-
-
38949162593
-
A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty
-
Rosneck J, Klika A, Barsoum W A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty. J Arthroplasty 2008, 23(2):311-313.
-
(2008)
J Arthroplasty
, vol.23
, Issue.2
, pp. 311-313
-
-
Rosneck, J.1
Klika, A.2
Barsoum, W.3
-
153
-
-
48949118899
-
The noisy ceramic hip: is component malpositioning the cause?
-
Restrepo C, Parvizi J, Kurtz SM, Sharkey PF, Hozack WJ, Rothman RH The noisy ceramic hip: is component malpositioning the cause?. J Arthroplasty 2008, 23(5):643-649.
-
(2008)
J Arthroplasty
, vol.23
, Issue.5
, pp. 643-649
-
-
Restrepo, C.1
Parvizi, J.2
Kurtz, S.M.3
Sharkey, P.F.4
Hozack, W.J.5
Rothman, R.H.6
-
154
-
-
44649167688
-
Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis
-
Baek SH, Kim SY Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis. J Bone Joint Surg Am 2008, 90(6):1314-1320.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.6
, pp. 1314-1320
-
-
Baek, S.H.1
Kim, S.Y.2
-
155
-
-
38449101029
-
The squeaking hip: a cause for concern-disagrees
-
Yang CC, Kim RH, Dennis DA The squeaking hip: a cause for concern-disagrees. Orthopedics 2007, 30(9):739-742.
-
(2007)
Orthopedics
, vol.30
, Issue.9
, pp. 739-742
-
-
Yang, C.C.1
Kim, R.H.2
Dennis, D.A.3
-
156
-
-
34249933860
-
Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation
-
Walter WL, O'Toole GC, Walter WK, Ellis A, Zicat BA Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty 2007, 22(4):496-503.
-
(2007)
J Arthroplasty
, vol.22
, Issue.4
, pp. 496-503
-
-
Walter, W.L.1
O'Toole, G.C.2
Walter, W.K.3
Ellis, A.4
Zicat, B.A.5
-
157
-
-
34848915750
-
The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings
-
Taylor S, Manley MT, Sutton K The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty 2007, 22(7 Suppl 3):47-51.
-
(2007)
J Arthroplasty
, vol.22
, Issue.7 SUPPL.3
, pp. 47-51
-
-
Taylor, S.1
Manley, M.T.2
Sutton, K.3
-
158
-
-
35948943543
-
The squeaking hip: a cause for concern-agrees
-
Ranawat AS, Ranawat CS The squeaking hip: a cause for concern-agrees. Orthopedics 2007, 30(9):738-743.
-
(2007)
Orthopedics
, vol.30
, Issue.9
, pp. 738-743
-
-
Ranawat, A.S.1
Ranawat, C.S.2
-
159
-
-
33845347570
-
Squeaking in a ceramic on ceramic total hip
-
Steinkopff Verlag, Darmstadt, H. Zippel, M. Dietrich (Eds.)
-
Eickmann TH, Clarke IC, Gustafson GA Squeaking in a ceramic on ceramic total hip. Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings 2003, 187-191. Steinkopff Verlag, Darmstadt. H. Zippel, M. Dietrich (Eds.).
-
(2003)
Bioceramics in joint arthroplasty, 8th Biolox symposium proceedings
, pp. 187-191
-
-
Eickmann, T.H.1
Clarke, I.C.2
Gustafson, G.A.3
-
160
-
-
55849139351
-
Squeaking hips
-
In press
-
Walter WK, Waters TS, Gillies M, Donohoo S, Kurtz SM, Ranawat AS, et al. Squeaking hips. J Bone Joint Surg [Am] 2008, 90(Suppl 4). In press.
-
(2008)
J Bone Joint Surg [Am]
, vol.90
, Issue.SUPPL.4
-
-
Walter, W.K.1
Waters, T.S.2
Gillies, M.3
Donohoo, S.4
Kurtz, S.M.5
Ranawat, A.S.6
-
161
-
-
0032775639
-
Advances in the processing, sterilization, and crosslinking of ultra- high molecular weight polyethylene for total joint arthroplasty
-
Kurtz SM, Muratoglu OK, Evans M, Edidin AA Advances in the processing, sterilization, and crosslinking of ultra- high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999, 20(18):1659-1688.
-
(1999)
Biomaterials
, vol.20
, Issue.18
, pp. 1659-1688
-
-
Kurtz, S.M.1
Muratoglu, O.K.2
Evans, M.3
Edidin, A.A.4
-
162
-
-
24944463697
-
Highly cross-linked poly-ethylene: the debate is over-in the affirmative
-
Jasty M, Rubash HE, Muratoglu O Highly cross-linked poly-ethylene: the debate is over-in the affirmative. J Arthroplasty 2005, 20(4 Suppl 2):55-68.
-
(2005)
J Arthroplasty
, vol.20
, Issue.4 SUPPL.2
, pp. 55-68
-
-
Jasty, M.1
Rubash, H.E.2
Muratoglu, O.3
-
163
-
-
0026881002
-
Improvement of polyethylene by irradiation in artificial joints
-
Oonishi H, Takayama Y, Tsuji E Improvement of polyethylene by irradiation in artificial joints. Radiation Physics and Chemistry 1992, 39(6):495-504.
-
(1992)
Radiation Physics and Chemistry
, vol.39
, Issue.6
, pp. 495-504
-
-
Oonishi, H.1
Takayama, Y.2
Tsuji, E.3
-
164
-
-
0001486818
-
Long term clinical results of THR. Clinical results of THR of an alumina head with a cross-linked UHMWPE cup
-
Oonishi H Long term clinical results of THR. Clinical results of THR of an alumina head with a cross-linked UHMWPE cup. Orthop Surg and Traumatol 1995, 38(11):1255-1264.
-
(1995)
Orthop Surg and Traumatol
, vol.38
, Issue.11
, pp. 1255-1264
-
-
Oonishi, H.1
-
165
-
-
0001903996
-
The low wear of cross-linked polyethylene socket in total hip prostheses
-
Marcel Dekker, New York, D.L. Wise, D.J. Trantolo, D.E. Altobelli, M.J. Yaszemski, J.D. Gresser, E.R. Schwartz (Eds.)
-
Oonishi H, Takayama Y, Tsuji E The low wear of cross-linked polyethylene socket in total hip prostheses. Encyclopedic handbook of biomaterials and bioengineering Part A: Materials 1995, 1853-1868. Marcel Dekker, New York. D.L. Wise, D.J. Trantolo, D.E. Altobelli, M.J. Yaszemski, J.D. Gresser, E.R. Schwartz (Eds.).
-
(1995)
Encyclopedic handbook of biomaterials and bioengineering Part A: Materials
, pp. 1853-1868
-
-
Oonishi, H.1
Takayama, Y.2
Tsuji, E.3
-
166
-
-
0018186475
-
The radiation improvement of polyethylene prostheses: A preliminary study
-
Grobbelaar CJ, Du Plessis TA, Marais F The radiation improvement of polyethylene prostheses: A preliminary study. J Bone Joint Surg 1978, 60-B(3):370-374.
-
(1978)
J Bone Joint Surg
, Issue.3
, pp. 370-374
-
-
Grobbelaar, C.J.1
Du Plessis, T.A.2
Marais, F.3
-
167
-
-
0029887658
-
Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
-
Wroblewski BM, Siney PD, Dowson D, Collins SN Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone & Joint Surg 1996, 78B:280-285.
-
(1996)
J Bone & Joint Surg
, vol.78 B
, pp. 280-285
-
-
Wroblewski, B.M.1
Siney, P.D.2
Dowson, D.3
Collins, S.N.4
-
168
-
-
52449106712
-
How have new sterilization techniques and new forms of polyethylene influenced wear in total joint replacement?
-
Crowninshield RD, Muratoglu OK How have new sterilization techniques and new forms of polyethylene influenced wear in total joint replacement?. J Am Acad Orthop Surg 2008, 16(Suppl 1):S80-85.
-
(2008)
J Am Acad Orthop Surg
, vol.16
, Issue.SUPPL.1
-
-
Crowninshield, R.D.1
Muratoglu, O.K.2
-
169
-
-
52449124174
-
How have alternative bearings (such as metal-on-metal, highly cross-linked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis?
-
Callaghan JJ, Cuckler JM, Huddleston JI, Galante JO How have alternative bearings (such as metal-on-metal, highly cross-linked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis?. J Am Acad Orthop Surg 2008, 16(Suppl 1):S33-38.
-
(2008)
J Am Acad Orthop Surg
, vol.16
, Issue.SUPPL.1
-
-
Callaghan, J.J.1
Cuckler, J.M.2
Huddleston, J.I.3
Galante, J.O.4
-
170
-
-
28444433471
-
Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene
-
Gencur SJ, Rimnac CM, Kurtz SM Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene. Biomaterials 2006, 27(8):1550-1557.
-
(2006)
Biomaterials
, vol.27
, Issue.8
, pp. 1550-1557
-
-
Gencur, S.J.1
Rimnac, C.M.2
Kurtz, S.M.3
-
171
-
-
0036017396
-
Thermomechanical behavior of virgin and highly cross-linked ultra-high molecular weight polyethylene used in total joint replacements
-
Kurtz SM, Villarraga ML, Herr MP, Bergstrom JS, Rimnac CM, Edidin AA Thermomechanical behavior of virgin and highly cross-linked ultra-high molecular weight polyethylene used in total joint replacements. Biomaterials 2002, 23(17):3681-3697.
-
(2002)
Biomaterials
, vol.23
, Issue.17
, pp. 3681-3697
-
-
Kurtz, S.M.1
Villarraga, M.L.2
Herr, M.P.3
Bergstrom, J.S.4
Rimnac, C.M.5
Edidin, A.A.6
-
172
-
-
0142200534
-
Effects of dose rate and thermal treatment on the physical and mechanical properties of highly crosslinked UHMWPE used in total joint replacements
-
New Orleans, LA; 2003 February 9-13.
-
Kurtz SM, Cooper C, Siskey R, Hubbard N. Effects of dose rate and thermal treatment on the physical and mechanical properties of highly crosslinked UHMWPE used in total joint replacements. Transactions of the 49th orthopedic research society. New Orleans, LA; 2003 February 9-13.
-
Transactions of the 49th orthopedic research society
-
-
Kurtz, S.M.1
Cooper, C.2
Siskey, R.3
Hubbard, N.4
-
173
-
-
0038377243
-
Comparison of the properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials
-
Kurtz SM, Manley M, Wang A, Taylor S, Dumbleton J Comparison of the properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials. Bull Hosp Jt Dis 2002-2003, 61(1-2):17-26.
-
(2002)
Bull Hosp Jt Dis
, vol.61
, Issue.1-2
, pp. 17-26
-
-
Kurtz, S.M.1
Manley, M.2
Wang, A.3
Taylor, S.4
Dumbleton, J.5
-
174
-
-
1842473877
-
Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report
-
Halley D, Glassman A, Crowninshield RD Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report. J Bone Joint Surg Am 2004, 86-A(4):827-830.
-
(2004)
J Bone Joint Surg Am
, Issue.4
, pp. 827-830
-
-
Halley, D.1
Glassman, A.2
Crowninshield, R.D.3
-
175
-
-
35349019671
-
Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty
-
Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 2007, 89(10):2212-2217.
-
(2007)
J Bone Joint Surg Am
, vol.89
, Issue.10
, pp. 2212-2217
-
-
Tower, S.S.1
Currier, J.H.2
Currier, B.H.3
Lyford, K.A.4
Van Citters, D.W.5
Mayor, M.B.6
-
176
-
-
33845444781
-
Significance of in vivo degradation for polyethylene in total hip arthroplasty
-
Kurtz SM, Hozack WJ, Purtill JJ, Marcolongo M, Kraay MJ, Goldberg VM, et al. Significance of in vivo degradation for polyethylene in total hip arthroplasty. Clin Orthop Relat Res 2006, 453:47-57.
-
(2006)
Clin Orthop Relat Res
, vol.453
, pp. 47-57
-
-
Kurtz, S.M.1
Hozack, W.J.2
Purtill, J.J.3
Marcolongo, M.4
Kraay, M.J.5
Goldberg, V.M.6
-
177
-
-
25844460615
-
Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report
-
Wroblewski BM, Siney PD, Fleming PA Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report. J Bone Joint Surg Br 2005 Sep, 87(9):1220-1221.
-
(2005)
J Bone Joint Surg Br
, vol.87
, Issue.9
, pp. 1220-1221
-
-
Wroblewski, B.M.1
Siney, P.D.2
Fleming, P.A.3
-
178
-
-
0035176116
-
Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results
-
Nov
-
Urban JA, Garvin KL, Boese CK, Bryson L, Pedersen DR, Callaghan JJ, et al. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am 2001, 83-A(11):1688-1694. Nov.
-
(2001)
J Bone Joint Surg Am
, Issue.11
, pp. 1688-1694
-
-
Urban, J.A.1
Garvin, K.L.2
Boese, C.K.3
Bryson, L.4
Pedersen, D.R.5
Callaghan, J.J.6
|