메뉴 건너뛰기




Volumn 89, Issue 10, 2007, Pages 2212-2217

Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

POLYETHYLENE;

EID: 35349019671     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/JBJS.F.00758     Document Type: Article
Times cited : (235)

References (17)
  • 1
    • 0345060377 scopus 로고    scopus 로고
    • Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator
    • Hermida JC, Bergula A, Chen P, Colwell CW Jr, D'Lima DD. Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator. J Bone Joint Surg Am. 2003;85:2325-31.
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 2325-2331
    • Hermida, J.C.1    Bergula, A.2    Chen, P.3    Colwell Jr, C.W.4    D'Lima, D.D.5
  • 2
    • 16244371708 scopus 로고    scopus 로고
    • Third-body wear testing of a highly cross-linked acetabular liner: The effect of large femoral head size in the presence of particulate poly(methyl-methacrylate) debris
    • Bragdon CR, Jasty M, Muratoglu OK, Harris WH. Third-body wear testing of a highly cross-linked acetabular liner: the effect of large femoral head size in the presence of particulate poly(methyl-methacrylate) debris. J Arthroplasty. 2005;20:379-85.
    • (2005) J Arthroplasty , vol.20 , pp. 379-385
    • Bragdon, C.R.1    Jasty, M.2    Muratoglu, O.K.3    Harris, W.H.4
  • 4
    • 0035217940 scopus 로고    scopus 로고
    • Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept
    • Muratoglu OK, Bragdon CR, O'Connor D, Perinchief RS, Estok DM 2nd, Jasty M, Harris WH. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. J Arthroplasty. 2001;16(8 Suppl 1):24-30.
    • (2001) J Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 24-30
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3    Perinchief, R.S.4    Estok 2nd, D.M.5    Jasty, M.6    Harris, W.H.7
  • 7
    • 0036381521 scopus 로고    scopus 로고
    • Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE
    • Cole JC, Lemons JE, Eberhardt AW. Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE. J Biomed Mater Res. 2002;63:559-66.
    • (2002) J Biomed Mater Res , vol.63 , pp. 559-566
    • Cole, J.C.1    Lemons, J.E.2    Eberhardt, A.W.3
  • 8
    • 0036434749 scopus 로고    scopus 로고
    • J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE
    • Gomoll A, Wanich T, Bellare A. J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE. J Orthop Res. 2002;20:1152-6.
    • (2002) J Orthop Res , vol.20 , pp. 1152-1156
    • Gomoll, A.1    Wanich, T.2    Bellare, A.3
  • 10
    • 0001157692 scopus 로고    scopus 로고
    • Global reference UHMWPE: Characterization and comparison to commercial ultrahigh molecular weight polyethylene
    • Feb 18-22; Atlanta. Georgia, p
    • Bennett AP, Wright TM, Li S. Global reference UHMWPE: characterization and comparison to commercial ultrahigh molecular weight polyethylene. In: Transactions of the 42nd Annual Meeting of the Orthopaedic Research Society; 1996 Feb 18-22; Atlanta. Georgia, p 472.
    • (1996) Transactions of the 42nd Annual Meeting of the Orthopaedic Research Society , pp. 472
    • Bennett, A.P.1    Wright, T.M.2    Li, S.3
  • 11
    • 0020826593 scopus 로고
    • Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses
    • Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res. 1983;17:829-42.
    • (1983) J Biomed Mater Res , vol.17 , pp. 829-842
    • Hood, R.W.1    Wright, T.M.2    Burstein, A.H.3
  • 12
    • 0003606769 scopus 로고    scopus 로고
    • Standard test method for tensile properties of plastics
    • ASTM D638-03:, Philadelphia: ASTM International;
    • ASTM D638-03: Standard test method for tensile properties of plastics. Philadelphia: ASTM International; 2003.
    • (2003)
  • 14
    • 34547561083 scopus 로고    scopus 로고
    • 1: Standard specification for ultra-high-molecular-weight polyethylene powder and fabricated form for surgical implants
    • ASTM F648-00e. Philadelphia: ASTM International;
    • ASTM F648-00e1: Standard specification for ultra-high-molecular-weight polyethylene powder and fabricated form for surgical implants. Philadelphia: ASTM International; 2000.
    • (2000)
  • 15
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20-32.
    • (1976) Clin Orthop Relat Res , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.