메뉴 건너뛰기




Volumn 89, Issue 4, 2007, Pages 535-537

Surface damage to an Oxinium femoral head prosthesis after dislocation

Author keywords

[No Author keywords available]

Indexed keywords

ZIRCONIUM;

EID: 34249788974     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.89B4.17557     Document Type: Article
Times cited : (64)

References (19)
  • 2
    • 0026605414 scopus 로고
    • Mechanism and clinical significance of wear debris induced ostoolysis
    • Amstutz HC, Campbell P, Kossovsky N, Clarke IC. Mechanism and clinical significance of wear debris induced ostoolysis. Clin Orthop 1992;276:7-18.
    • (1992) Clin Orthop , vol.276 , pp. 7-18
    • Amstutz, H.C.1    Campbell, P.2    Kossovsky, N.3    Clarke, I.C.4
  • 3
    • 34249824848 scopus 로고    scopus 로고
    • www.strongasanox.com. Smith & Nephew Oxinium femoral heads. Orthopedics technical information (date last accessed 3 April 2007).
    • www.strongasanox.com. Smith & Nephew Oxinium femoral heads. Orthopedics technical information (date last accessed 3 April 2007).
  • 4
    • 0033775261 scopus 로고    scopus 로고
    • Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear
    • Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear. Clin Orthop 2000;379:34-40.
    • (2000) Clin Orthop , vol.379 , pp. 34-40
    • Clarke, I.C.1    Gustafson, A.2
  • 5
    • 0035176116 scopus 로고    scopus 로고
    • Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty: Seventeen to twenty-one-year results
    • Urban JA, Garvin KL, Boese CK, et al. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty: seventeen to twenty-one-year results. J Bone Joint Surg [Am] 2001;83-A:1688-94.
    • (2001) J Bone Joint Surg [Am] , vol.83-A , pp. 1688-1694
    • Urban, J.A.1    Garvin, K.L.2    Boese, C.K.3
  • 6
    • 23044447438 scopus 로고    scopus 로고
    • Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: A prospective, randomized study
    • Kim YH. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: a prospective, randomized study. J Bone Joint Surg [Am] 2005;87-A:1769-76.
    • (2005) J Bone Joint Surg [Am] , vol.87-A , pp. 1769-1776
    • Kim, Y.H.1
  • 7
    • 2342552077 scopus 로고    scopus 로고
    • Bearing surface options for total hip replacement in young patients
    • Helsel C, Silva M, Schmalzried TP. Bearing surface options for total hip replacement in young patients. Instr Course Lect 2004;53:49-65.
    • (2004) Instr Course Lect , vol.53 , pp. 49-65
    • Helsel, C.1    Silva, M.2    Schmalzried, T.P.3
  • 8
    • 0242606961 scopus 로고    scopus 로고
    • Reduced wear with oxidized zirconium femoral heads
    • Good V, Ries M, Barrack RL, et al. Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg [Am] 2003;85-A:105-10.
    • (2003) J Bone Joint Surg [Am] , vol.85-A , pp. 105-110
    • Good, V.1    Ries, M.2    Barrack, R.L.3
  • 9
    • 0345060377 scopus 로고    scopus 로고
    • Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator
    • Hermida JC, Bergula A, Chan P, Colwell CW Jr, D'Lima DD. Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator. J Bone Joint Sury [Am] 2003;85-A: 2325-31.
    • (2003) J Bone Joint Sury [Am] , vol.85-A , pp. 2325-2331
    • Hermida, J.C.1    Bergula, A.2    Chan, P.3    Colwell Jr, C.W.4    D'Lima, D.D.5
  • 11
    • 0001033181 scopus 로고
    • Zirconia (Zr02)-coated zirconium-2.5Nb alloy for prosthetic knee bearing applications
    • Yamamuro T, Kokubo T Nakamura T, eds, Kyoto: Kobunshi Kankokai
    • Davidson JA, Asgian CM, Mishra AK, Kovacs P. Zirconia (Zr02)-coated zirconium-2.5Nb alloy for prosthetic knee bearing applications. In: Yamamuro T, Kokubo T Nakamura T, eds. Bioceramics. Vol 5. Kyoto: Kobunshi Kankokai, 1992:389-401.
    • (1992) Bioceramics , vol.5 , pp. 389-401
    • Davidson, J.A.1    Asgian, C.M.2    Mishra, A.K.3    Kovacs, P.4
  • 12
    • 0002259933 scopus 로고    scopus 로고
    • Abrasive wear of oxidized Xr-2.5b, CoCrMo, and Ti-6A1-4V against bone cement
    • Hunter G, Long M. Abrasive wear of oxidized Xr-2.5b, CoCrMo, and Ti-6A1-4V against bone cement. In: Procs sixth world biomaterials congress. 2000:835.
    • (2000) Procs sixth world biomaterials congress , pp. 835
    • Hunter, G.1    Long, M.2
  • 13
    • 0000967713 scopus 로고    scopus 로고
    • Adhesion testing of oxidized zirconium
    • Hunter G. Adhesion testing of oxidized zirconium. Trans Soc Biomater 2001;24:540.
    • (2001) Trans Soc Biomater , vol.24 , pp. 540
    • Hunter, G.1
  • 14
    • 0035175965 scopus 로고    scopus 로고
    • Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components
    • Spector BM, Ries MD, Bourne RB, et al. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J Bone Joint Surg [Am] 2001;83-A(Suppl 2):80-6.
    • (2001) J Bone Joint Surg [Am] , vol.83-A , Issue.SUPPL. 2 , pp. 80-86
    • Spector, B.M.1    Ries, M.D.2    Bourne, R.B.3
  • 15
    • 8644241678 scopus 로고    scopus 로고
    • Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator
    • Ezzot KA, Hermida JC, Colwell CW Jr, D'Lima DD. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator. Clin Orthop 2004;428:120-4.
    • (2004) Clin Orthop , vol.428 , pp. 120-124
    • Ezzot, K.A.1    Hermida, J.C.2    Colwell Jr, C.W.3    D'Lima, D.D.4
  • 16
    • 0036394796 scopus 로고    scopus 로고
    • Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions
    • Ries MD, Salehi A, Widding K, Hunter G. Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions. J Bone Joint Surg [Am] 2002; 84-A:129-35.
    • (2002) J Bone Joint Surg [Am] , vol.84-A , pp. 129-135
    • Ries, M.D.1    Salehi, A.2    Widding, K.3    Hunter, G.4
  • 17
    • 33644814678 scopus 로고    scopus 로고
    • Arthroplasty options for the young patient: Oxinium on cross-linked polyethylene
    • Bourne RB, Barrack R, Rorabeck CH, Salehi A, Good V. Arthroplasty options for the young patient: oxinium on cross-linked polyethylene. Clin Orthop 2005:441:159-67.
    • (2005) Clin Orthop , vol.441 , pp. 159-167
    • Bourne, R.B.1    Barrack, R.2    Rorabeck, C.H.3    Salehi, A.4    Good, V.5
  • 18
    • 18344379708 scopus 로고    scopus 로고
    • Wear analysis of retrieved ceramic-on-ceramic articulations in total hip arthroplasty: Femoral head makes contact with the rim of the socket outside of the bearing surface
    • Yamamoto T, Salto M, Ueno M, et al. Wear analysis of retrieved ceramic-on-ceramic articulations in total hip arthroplasty: femoral head makes contact with the rim of the socket outside of the bearing surface. J Biomed Mater Res B Appl Biomater 2005;73:301-7.
    • (2005) J Biomed Mater Res B Appl Biomater , vol.73 , pp. 301-307
    • Yamamoto, T.1    Salto, M.2    Ueno, M.3
  • 19
    • 14644414879 scopus 로고    scopus 로고
    • Surface roughness of ceramic femoral heads after in vivo transfer of metal: Correlation to polyethylene wear
    • Kim YH, Ritchie A, Hardaker C. Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear. J Bone Joint Surg [Am] 2005;87-A:577-82.
    • (2005) J Bone Joint Surg [Am] , vol.87-A , pp. 577-582
    • Kim, Y.H.1    Ritchie, A.2    Hardaker, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.