메뉴 건너뛰기




Volumn 20, Issue 19, 1999, Pages 1833-1840

Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses

Author keywords

Analysis; Ceramic; Total hip arthroplasty; Wear

Indexed keywords

ALUMINUM OXIDE;

EID: 0032881955     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(99)00081-2     Document Type: Article
Times cited : (133)

References (12)
  • 1
    • 0026605414 scopus 로고
    • Mechanism and clinical significance of wear debris-induced osteolysis
    • Amstutz H., Campbell P., Kossovsky N., Clarke I. Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop Rel Res. 276:1992;7-18.
    • (1992) Clin Orthop Rel Res , vol.276 , pp. 7-18
    • Amstutz, H.1    Campbell, P.2    Kossovsky, N.3    Clarke, I.4
  • 2
    • 0030331924 scopus 로고    scopus 로고
    • Cellular basis for failure of joint prostheses
    • Mohanty M. Cellular basis for failure of joint prostheses. Biomed Mater Eng. 6:1996;165-1720.
    • (1996) Biomed Mater Eng , vol.6 , pp. 165-1720
    • Mohanty, M.1
  • 3
    • 0011183682 scopus 로고
    • THR using alumina-alumina sliding and a metallic stem - 1330 cases and an 11 yr follow-up. Orthopaedic ceramic implants
    • Boutin P. THR using alumina-alumina sliding and a metallic stem - 1330 cases and an 11 yr follow-up. Orthopaedic ceramic implants, vol. 1. Proceedings of the Japanese Society of Orthopaedic Ceramic Implants, 1981.
    • (1981) Proceedings of the Japanese Society of Orthopaedic Ceramic Implants , vol.1
    • Boutin, P.1
  • 4
    • 0026641524 scopus 로고
    • Sixteen-years experience with ceramic hip prostheses
    • Mittelmeier H., Heisel J. Sixteen-years experience with ceramic hip prostheses. Clin Orthop. 282:1992;64-72.
    • (1992) Clin Orthop , vol.282 , pp. 64-72
    • Mittelmeier, H.1    Heisel, J.2
  • 5
    • 0025350439 scopus 로고
    • Unsatisfactory results with a ceramic total hip prosthesis
    • O. Mahoney, J. Dimon, Unsatisfactory results with a ceramic total hip prosthesis. J Bone Jt Surg 1990;72A(5).
    • (1990) J Bone Jt Surg , vol.72 A , Issue.5
    • Mahoney, O.1    Dimon, J.2
  • 9
    • 0029809897 scopus 로고    scopus 로고
    • Metal on metal total hip replacement workshop consensus document
    • Amstutz H., Campbell P., Mckellop H.et al. Metal on metal total hip replacement workshop consensus document. Clin Orthop Rel Res. 329S:1996;S297-303.
    • (1996) Clin Orthop Rel Res , vol.329 , pp. 297-303
    • Amstutz, H.1    Campbell, P.2    McKellop, H.3
  • 11
    • 0002065660 scopus 로고    scopus 로고
    • The improvements of the material properties of BIOLOX offer benefits for THR
    • In: Puhl W, editor. Germany
    • Willman G, Charnier W. The improvements of the material properties of BIOLOX offer benefits for THR. In: Puhl W, editor. Bioceramics in orthopaedics - new applications. Germany, 1998, pp. 19-21.
    • (1998) Bioceramics in Orthopaedics - New Applications , pp. 19-21
    • Willman, G.1    Charnier, W.2
  • 12
    • 0030627631 scopus 로고    scopus 로고
    • Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
    • Jin Z, Dowson D, Fisher J. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proc Instn Mech Engrs 1997;211 (Part H):247-56.
    • (1997) Proc Instn Mech Engrs , vol.211 , Issue.PART H , pp. 247-256
    • Jin, Z.1    Dowson, D.2    Fisher, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.