메뉴 건너뛰기




Volumn 9, Issue 3, 2010, Pages

Comparison of different metal film thicknesses of cyclic olefin copolymer-substrate polymerase chain-reaction chips with single-side and double-side heaters

Author keywords

Cyclic olefin copolymers; Double side heater; Polymerase chain reaction; Thermal conductivity; Thermal deformation temperature

Indexed keywords

COPOLYMERIZATION; COPOLYMERS; DEFORMATION; ESCHERICHIA COLI; METALLIC FILMS; OLEFINS; POLYMERS; SUBSTRATES; THERMAL CONDUCTIVITY;

EID: 80455150012     PISSN: 19325150     EISSN: 19325134     Source Type: Journal    
DOI: 10.1117/1.3455371     Document Type: Conference Paper
Times cited : (3)

References (40)
  • 1
    • 0026584033 scopus 로고
    • Planar chips technology for miniaturization and integration of separation techniques into monitoring systems: Capillary electrophoresis on a chip
    • A. Manz, D. J. Harrison, E. M. J. Verpoorte, J. C. Fettinger, A. Paulus, H. Ludi, and H. M. Widemr, "Planar chips technology for miniaturization and integration of separation techniques into monitoring systems: capillary electrophoresis on a chip," J. Chromatogr. 593, 253-258 (1992).
    • (1992) J. Chromatogr. , vol.593 , pp. 253-258
    • Manz, A.1    Harrison, D.J.2    Verpoorte, E.M.J.3    Fettinger, J.C.4    Paulus, A.5    Ludi, H.6    Widemr, H.M.7
  • 3
    • 0034321675 scopus 로고    scopus 로고
    • A rapid micro-polymerase chain reaction system for hepatitis C virus
    • Y. C. Lin, M. Y. Huang, K. C. Young, T. T. Chang, and C. T. Wu, "A rapid micro-polymerase chain reaction system for hepatitis C virus," Sens. Actuators, A 71, 2-8 (2000).
    • (2000) Sens. Actuators, A , vol.71 , pp. 2-8
    • Lin, Y.C.1    Huang, M.Y.2    Young, K.C.3    Chang, T.T.4    Wu, C.T.5
  • 5
    • 0031169963 scopus 로고    scopus 로고
    • UV laser machined polymer substrates for the development of microdiagnostic systems
    • M. A. Roberts, J. S. Rossier, P. Bercier, and H. Girault, "UV laser machined polymer substrates for the development of microdiagnostic systems," Anal. Chem. 69(11), 2035-2042 (1997). (Pubitemid 127698691)
    • (1997) Analytical Chemistry , vol.69 , Issue.12 , pp. 2035-2042
    • Girault, H.1
  • 6
    • 0032403465 scopus 로고    scopus 로고
    • Rapid prototyping of microfluidic system in poly(dimethylsiloxane)
    • D. C. Duffy, J. C. McDonald, O. A. J. Schueller, and G. M. Whitesides, "Rapid prototyping of microfluidic system in poly(dimethylsiloxane )," Anal. Chem. 70(23), 4974-4984 (1998).
    • (1998) Anal. Chem. , vol.70 , Issue.23 , pp. 4974-4984
    • Duffy, D.C.1    McDonald, J.C.2    Schueller, O.A.J.3    Whitesides, G.M.4
  • 7
    • 0033743165 scopus 로고    scopus 로고
    • Monolithic integrated microfluidic DNA amplification and capillary electrophoresis separation system
    • E. T. Lagally, P. C. Simpson, and R. A. Mathies, "Monolithic integrated microfluidic DNA amplification and capillary electrophoresis separation system," Sens. Actuators B 63, 138-146 (2000).
    • (2000) Sens. Actuators B , vol.63 , pp. 138-146
    • Lagally, E.T.1    Simpson, P.C.2    Mathies, R.A.3
  • 10
    • 20544478458 scopus 로고    scopus 로고
    • Advanced in polymerase chain reaction on microfluidic chips
    • M. G. Roper, C. J. Easley, and J. P. Landers, "Advanced in polymerase chain reaction on microfluidic chips," Anal. Chem. 77, 3887-3894 (2005).
    • (2005) Anal. Chem. , vol.77 , pp. 3887-3894
    • Roper, M.G.1    Easley, C.J.2    Landers, J.P.3
  • 12
    • 33644842733 scopus 로고    scopus 로고
    • A disposable microfluidic cassette for DNA amplification and detection
    • J. Wang, Z. Chen, P. L. A. M. Corstjens, M. G. Mauk, and H. H. Bau, "A disposable microfluidic cassette for DNA amplification and detection," Lab Chip 6, 46-53 (2006).
    • (2006) Lab Chip , vol.6 , pp. 46-53
    • Wang, J.1    Chen, Z.2    Corstjens, P.L.A.M.3    Mauk, M.G.4    Bau, H.H.5
  • 13
    • 33344456867 scopus 로고    scopus 로고
    • Micro-Raman thermometry for measuring the temperature distribution inside the microchannel of a polymerase chain reaction chip
    • DOI 10.1088/0960-1317/16/3/007, PII S0960131706058141
    • S. H. Kim, J. Noh, M. K. Jeon, K. W. Kim, L. P. Lee, and S. I. Woo, "Micro-Raman, thermometry for measuring the temperature distribution inside the microchannel of a polymerase chain reaction chip," J. Micromech. Microeng. 16, 526-530 (2006). (Pubitemid 43289729)
    • (2006) Journal of Micromechanics and Microengineering , vol.16 , Issue.3 , pp. 526-530
    • Kim, S.H.1    Noh, J.2    Jeon, M.K.3    Kim, K.W.4    Lee, L.P.5    Woo, S.I.6
  • 14
    • 33745685152 scopus 로고    scopus 로고
    • On-chip pressure injection for integration of infrared-mediated DNA amplification with electrophoresis separation
    • C. J. Easley, J. M. Karlinsey, and J. P. Landers, "On-chip pressure injection for integration of infrared-mediated DNA amplification with electrophoresis separation," Lab Chip 6, 601-610 (2006).
    • (2006) Lab Chip , vol.6 , pp. 601-610
    • Easley, C.J.1    Karlinsey, J.M.2    Landers, J.P.3
  • 15
    • 33644746296 scopus 로고    scopus 로고
    • A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples
    • DOI 10.1021/ac0516988
    • L. A. Legendre, J. M. Bienvenue, M. G. Roper, J. P. Ferrance, and J. P. Landers, "A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples," Anal. Chem. 78, 1444-1451 (2006). (Pubitemid 43346278)
    • (2006) Analytical Chemistry , vol.78 , Issue.5 , pp. 1444-1451
    • Legendre, L.A.1    Bienvenue, J.M.2    Roper, M.G.3    Ferrance, J.P.4    Landers, J.P.5
  • 16
    • 33645844551 scopus 로고    scopus 로고
    • PCR microfluidic devices for DNA amplification
    • C. Zhang, J. Xu, W. Ma, and W. Zheng, "PCR microfluidic devices for DNA amplification," Biotechnol. Adv. 24, 243-284 (2006).
    • (2006) Biotechnol. Adv. , vol.24 , pp. 243-284
    • Zhang, C.1    Xu, J.2    Ma, W.3    Zheng, W.4
  • 17
    • 34748814526 scopus 로고    scopus 로고
    • Micro air bubble formation and its control during polymerase chain reaction (PCR) in polydimethylsiloxane (PDMS) microreactors
    • DOI 10.1088/0960-1317/17/10/018, PII S0960131707537198, 018
    • H. B. Liu, H. Q. Gong, N. Ramalingam, Y. Jiang, C. C. Dai, and K. M. Hui, "Micro air bubble formation and its control during polymerase chain reaction, (PCR) in polydimethysiloxane (PDMS) microreactors," J. Micromech. Microeng. 17, 2055-2064 (2007). (Pubitemid 47469913)
    • (2007) Journal of Micromechanics and Microengineering , vol.17 , Issue.10 , pp. 2055-2064
    • Liu, H.-B.1    Gong, H.-Q.2    Ramalingam, N.3    Jiang, Y.4    Dai, C.-C.5    Hui, K.M.6
  • 19
    • 33846587591 scopus 로고    scopus 로고
    • Integrated reverse transcription polymerase chain reaction systems for virus detection
    • K. Y. Lien, W. C. Lee, H. Y. Lei, and G. B. Lee, "Integrated reverse transcription polymerase chain reaction systems for virus detection," Biosens. Bioelectron. 22, 1739-1748 (2007).
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 1739-1748
    • Lien, K.Y.1    Lee, W.C.2    Lei, H.Y.3    Lee, G.B.4
  • 20
    • 62649154973 scopus 로고    scopus 로고
    • Microfluidic systems integrated with a sample pretreatment device for fast nucleic-acid amplification
    • K. Y. Lien, W. Y. Lin, Y. F. Lee, C. H. Wang, H. Y. Lei, and G. B. Lee, "Microfluidic systems integrated with a sample pretreatment device for fast nucleic-acid amplification," J. Microelectromech. Syst. 17, 288-301 (2008).
    • (2008) J. Microelectromech. Syst. , vol.17 , pp. 288-301
    • Lien, K.Y.1    Lin, W.Y.2    Lee, Y.F.3    Wang, C.H.4    Lei, H.Y.5    Lee, G.B.6
  • 21
    • 40949165357 scopus 로고    scopus 로고
    • Enhancement of thermal uniformity for a microthermal cyclyer and its application for polymerase chain reaction
    • T. M. Hsieh, C. H. Luo, F. C. Huang, J. H. Wang, L. J. Chien, and G. B. Lee, "Enhancement of thermal uniformity for a microthermal cyclyer and its application for polymerase chain reaction," Sens. Actuators B 130, 848-856 (2008).
    • (2008) Sens. Actuators B , vol.130 , pp. 848-856
    • Hsieh, T.M.1    Luo, C.H.2    Huang, F.C.3    Wang, J.H.4    Chien, L.J.5    Lee, G.B.6
  • 22
    • 70349974155 scopus 로고    scopus 로고
    • Fast and accurate temperature control of a PCR microsystem with a disposable reactor
    • M. P. Dinca, M. Gheorghe, M. Aherne, and P. Galvin, "Fast and accurate temperature control of a PCR microsystem with a disposable reactor," J. Micromech. Microeng. 19, 065009 (2009).
    • (2009) J. Micromech. Microeng. , vol.19 , pp. 065009
    • Dinca, M.P.1    Gheorghe, M.2    Aherne, M.3    Galvin, P.4
  • 27
    • 1642603474 scopus 로고    scopus 로고
    • Review on micro molding of thermoplastic polymers
    • M. Heckele and W. K. Schomburg, "Review on micro molding of thermoplastic polymers," J. Micromech. Microeng. 14, R1-R14 (2004).
    • (2004) J. Micromech. Microeng. , vol.14
    • Heckele, M.1    Schomburg, W.K.2
  • 28
    • 0033732466 scopus 로고    scopus 로고
    • Hot embossing as a method for the fabrication of polymer high aspect ratio structures
    • H. Becker and U. Heim, "Hot embossing as a method for the fabrication of polymer high aspect ratio structures," Sens. Actuators, A 83, 130-135 (2000).
    • (2000) Sens. Actuators, A , vol.83 , pp. 130-135
    • Becker, H.1    Heim, U.2
  • 29
    • 0343550309 scopus 로고    scopus 로고
    • Polymer microfabrication methods for microfluidic analytical applications
    • H. Becker and C. Gartner, "Polymer microfabrication methods microfluidic analytical applications," Electrophoresis 21, 12-26 (2000). (Pubitemid 30032693)
    • (2000) Electrophoresis , vol.21 , Issue.1 , pp. 12-26
    • Becker, H.1    Gartner, C.2
  • 32
    • 44649189102 scopus 로고    scopus 로고
    • Polymer microchip integrated with nano-electrospray tip for electrophoresis- mass spectrometry
    • H. Shinohara, T. Suzuki, F. Kitagawa, J. Mizuno, K. Otsuka, and S. Shoji, "Polymer microchip integrated with nano-electrospray tip for electrophoresis- mass spectrometry," Sens. Actuators B 132, 368-373 (2008).
    • (2008) Sens. Actuators B , vol.132 , pp. 368-373
    • Shinohara, H.1    Suzuki, T.2    Kitagawa, F.3    Mizuno, J.4    Otsuka, K.5    Shoji, S.6
  • 35
    • 44649098143 scopus 로고    scopus 로고
    • Surface hydrophilic treatment of polyurea film realized by vacuum ultraviolet light irradiation application for poly(methylmethacrylate) blood analysis chip
    • H. Shinohara, Y. Takahashi, J. Mizuno, and S. Shoji, "Surface hydrophilic treatment of polyurea film realized by vacuum ultraviolet light irradiation application for poly(methylmethacrylate) blood analysis chip," Sens. Actuators B 132, 374-379 (2008).
    • (2008) Sens. Actuators B , vol.132 , pp. 374-379
    • Shinohara, H.1    Takahashi, Y.2    Mizuno, J.3    Shoji, S.4
  • 36
    • 67349186400 scopus 로고    scopus 로고
    • An optical PMMA biochip based on fluorescence anisotropy: Application to C-reactive protein assay
    • F. Baldini, A. Carloni, A. Giannetti, G. Porro, and C. Trono, "An optical PMMA biochip based on fluorescence anisotropy: application to C-reactive protein assay," Sens. Actuators B 139, 64-68 (2009).
    • (2009) Sens. Actuators B , vol.139 , pp. 64-68
    • Baldini, F.1    Carloni, A.2    Giannetti, A.3    Porro, G.4    Trono, C.5
  • 37
    • 46449113214 scopus 로고    scopus 로고
    • Specific DNA extraction through fluid channels with immobilization of layered double hydroxides on polycarbonate surface
    • C. H. Chan, J. K. Chen, and F. C. Chang, "Specific DNA extraction through fluid channels with immobilization of layered double hydroxides on polycarbonate surface," Sens. Actuators B 133, 327-332 (2008).
    • (2008) Sens. Actuators B , vol.133 , pp. 327-332
    • Chan, C.H.1    Chen, J.K.2    Chang, F.C.3
  • 39
    • 40949136551 scopus 로고    scopus 로고
    • Continuous flow polymerase chain reaction using a hybrid PMMA-PC microchip with improved heat tolerance
    • DOI 10.1016/j.snb.2007.10.058, PII S0925400507008829
    • Y. Sun, M. V. D. Satyanarayan, N. T. Nguyen, and Y. C. Kwok, "Continuous flow polymerase chain reaction using a hybrid PMMA-PC microchip with improved heat tolerance," Sens. Actuators B 130, 836-841 (2008). (Pubitemid 351417415)
    • (2008) Sensors and Actuators, B: Chemical , vol.130 , Issue.2 , pp. 836-841
    • Sun, Y.1    Satyanarayan, M.V.D.2    Nguyen, N.T.3    Kwok, Y.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.