메뉴 건너뛰기




Volumn 24, Issue 3, 2011, Pages 207-220

Fit of screw-retained fixed implant frameworks fabricated by different methods: A systematic review

Author keywords

[No Author keywords available]

Indexed keywords

BONE SCREW; COMPUTER AIDED DESIGN; DENTURE; HUMAN; INSTRUMENTATION; PROSTHESIS; REVIEW; STATISTICAL MODEL; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 80052878672     PISSN: 08932174     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (95)

References (49)
  • 1
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • Brånemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410.
    • (1983) J Prosthet Dent , vol.50 , pp. 399-410
    • Brånemark, P.I.1
  • 2
    • 0034574104 scopus 로고    scopus 로고
    • Mechanical complications of dental implants
    • Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res 2000;11(suppl 1):156-158.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 156-158
    • Schwarz, M.S.1
  • 4
    • 0035223781 scopus 로고    scopus 로고
    • The significance of passive framework fit in implant prosthodontics: Current status
    • Sahin S, Cehreli MC. The significance of passive framework fit in implant prosthodontics: Current status. Implant Dent 2001; 10:85-92.
    • (2001) Implant Dent , vol.10 , pp. 85-92
    • Sahin, S.1    Cehreli, M.C.2
  • 6
    • 21344467490 scopus 로고    scopus 로고
    • Strain situation after fixation of three-unit ceramic veneered implant superstructures
    • Karl M, Rösch S, Graef F, Taylor TD, Heckmann SM. Strain situation after fixation of three-unit ceramic veneered implant superstructures. Implant Dent 2005;14:157-165.
    • (2005) Implant Dent , vol.14 , pp. 157-165
    • Karl, M.1    Rösch, S.2    Graef, F.3    Taylor, T.D.4    Heckmann, S.M.5
  • 7
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-276.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 8
    • 0031609120 scopus 로고    scopus 로고
    • Prosthodontic problems and limitations associated with osseointegration
    • Taylor TD. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998;79:74-78.
    • (1998) J Prosthet Dent , vol.79 , pp. 74-78
    • Taylor, T.D.1
  • 9
    • 0029439074 scopus 로고
    • Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit
    • Clelland NL, Papazoglou E, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit. J Prosthodont 1995;4:243-250.
    • (1995) J Prosthodont , vol.4 , pp. 243-250
    • Clelland, N.L.1    Papazoglou, E.2    Carr, A.B.3    Gilat, A.4
  • 10
    • 21344461711 scopus 로고    scopus 로고
    • Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: A preliminary clinical and radiologic report
    • Bergkvist G, Sahlholm S, Karlsson U, Nilner K, Lindh C. Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: A preliminary clinical and radiologic report. Int J Oral Maxillofac Implants 2005;20:399-405.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 399-405
    • Bergkvist, G.1    Sahlholm, S.2    Karlsson, U.3    Nilner, K.4    Lindh, C.5
  • 11
    • 0033182713 scopus 로고    scopus 로고
    • Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings
    • Zervas PJ, Papazoglou E, Beck FM, Carr AB. Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings. J Prosthodont 1999;8:171-179.
    • (1999) J Prosthodont , vol.8 , pp. 171-179
    • Zervas, P.J.1    Papazoglou, E.2    Beck, F.M.3    Carr, A.B.4
  • 12
    • 4143149751 scopus 로고    scopus 로고
    • In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion
    • Sartori IA, Ribeiro RF, Francischone CE, de Mattos Mda G. In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion. J Prosthet Dent 2004;92:132-138.
    • (2004) J Prosthet Dent , vol.92 , pp. 132-138
    • Sartori, I.A.1    Ribeiro, R.F.2    Francischone, C.E.3    de Mattos Mda, G.4
  • 13
    • 33745637011 scopus 로고    scopus 로고
    • The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding
    • Castilio D, Pedreira AP, Rossetti PH, Rossetti LM, Bonachela WC. The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding. J Appl Oral Sci 2006;14:77-81.
    • (2006) J Appl Oral Sci , vol.14 , pp. 77-81
    • Castilio, D.1    Pedreira, A.P.2    Rossetti, P.H.3    Rossetti, L.M.4    Bonachela, W.C.5
  • 14
    • 34548677726 scopus 로고    scopus 로고
    • The effect of commercially pure titanium and alternative dental alloys on the marginal fit of one-piece cast implant frameworks
    • de Torres EM, Rodrigues RC, de Mattos Mda G, Ribeiro RF. The effect of commercially pure titanium and alternative dental alloys on the marginal fit of one-piece cast implant frameworks. J Dent 2007;35:800-805.
    • (2007) J Dent , vol.35 , pp. 800-805
    • de Torres, E.M.1    Rodrigues, R.C.2    de Mattos Mda, G.3    Ribeiro, R.F.4
  • 15
    • 42449121855 scopus 로고    scopus 로고
    • Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings
    • Tiossi R, Rodrigues RC, de Mattos Mda G, Ribeiro RF. Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings. Int J Prosthodont 2008;21:121-123.
    • (2008) Int J Prosthodont , vol.21 , pp. 121-123
    • Tiossi, R.1    Rodrigues, R.C.2    de Mattos Mda, G.3    Ribeiro, R.F.4
  • 16
    • 64149092711 scopus 로고    scopus 로고
    • An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis
    • de Aguiar FA Jr, Tiossi R, Rodrigues RC, Mattos Mde G, Ribeiro RF. An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis. J Prosthodont 2009;18:230-234.
    • (2009) J Prosthodont , vol.18 , pp. 230-234
    • de Aguiar, F.A.1    Tiossi, R.2    Rodrigues, R.C.3    Mattos Mde, G.4    Ribeiro, R.F.5
  • 17
    • 0039415479 scopus 로고
    • The construction of a mandibular fixed complete framework
    • White GE (ed)., Chicago: Quintessence
    • White GE. The construction of a mandibular fixed complete framework. In: White GE (ed). Osseointegrated Dental Technology. Chicago: Quintessence, 1993:103-129.
    • (1993) Osseointegrated Dental Technology , pp. 103-129
    • White, G.E.1
  • 20
    • 38149111056 scopus 로고    scopus 로고
    • Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding
    • de Sousa SA, de Arruda Nobilo MA, Henriques GE, Mesquita MF. Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding. J Oral Rehabil 2008;35:123-127.
    • (2008) J Oral Rehabil , vol.35 , pp. 123-127
    • de Sousa, S.A.1    de Arruda Nobilo, M.A.2    Henriques, G.E.3    Mesquita, M.F.4
  • 21
    • 79958242718 scopus 로고    scopus 로고
    • Misfit of suprastructures on implants processed by electrical discharge machining or the Cresco method
    • Fischer J, Thoma A, Suter A, Lüthy H, Luder HU, Hämmerle CH. Misfit of suprastructures on implants processed by electrical discharge machining or the Cresco method. Quintessence Int 2009;40:515-522.
    • (2009) Quintessence Int , vol.40 , pp. 515-522
    • Fischer, J.1    Thoma, A.2    Suter, A.3    Lüthy, H.4    Luder, H.U.5    Hämmerle, C.H.6
  • 22
    • 0029351262 scopus 로고
    • Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations
    • Jemt T. Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations. J Oral Rehabil 1995;22:557-564.
    • (1995) J Oral Rehabil , vol.22 , pp. 557-564
    • Jemt, T.1
  • 23
    • 0031301642 scopus 로고    scopus 로고
    • Fit of implant frameworks fabricated by different techniques
    • Riedy SJ, Lang BR, Lang BE. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent 1997;78:596-604.
    • (1997) J Prosthet Dent , vol.78 , pp. 596-604
    • Riedy, S.J.1    Lang, B.R.2    Lang, B.E.3
  • 24
    • 0033122309 scopus 로고    scopus 로고
    • Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw
    • Jemt T, Bäck T, Petersson A. Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw. Int J Prosthodont 1999;12:209-215.
    • (1999) Int J Prosthodont , vol.12 , pp. 209-215
    • Jemt, T.1    Bäck, T.2    Petersson, A.3
  • 25
    • 0037629996 scopus 로고    scopus 로고
    • Fit of implant frameworks: An in vitro comparison between two fabrication techniques
    • Takahashi T, Gunne J. Fit of implant frameworks: An in vitro comparison between two fabrication techniques. J Prosthet Dent 2003;89:256-260.
    • (2003) J Prosthet Dent , vol.89 , pp. 256-260
    • Takahashi, T.1    Gunne, J.2
  • 26
    • 34047251477 scopus 로고    scopus 로고
    • A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks
    • Al-Fadda SA, Zarb GA, Finer Y. A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks. Int J Prosthodont 2007;20:125-131.
    • (2007) Int J Prosthodont , vol.20 , pp. 125-131
    • Al-Fadda, S.A.1    Zarb, G.A.2    Finer, Y.3
  • 27
    • 78349279943 scopus 로고    scopus 로고
    • Precision of fit to implants: A comparison of Cresco and Procera implant bridge frameworks
    • Hjalmarsson L, Örtorp A, Smedberg JI, Jemt T. Precision of fit to implants: A comparison of Cresco and Procera implant bridge frameworks. Clin Implant Dent Relat Res 2010;12:271-280.
    • (2010) Clin Implant Dent Relat Res , vol.12 , pp. 271-280
    • Hjalmarsson, L.1    Örtorp, A.2    Smedberg, J.I.3    Jemt, T.4
  • 28
    • 5444221207 scopus 로고    scopus 로고
    • Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys
    • Costa HM, Rodrigues RC, Mattos Mda G, Ribeiro RF. Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys. Braz Dent J 2003;14:197-202.
    • (2003) Braz Dent J , vol.14 , pp. 197-202
    • Costa, H.M.1    Rodrigues, R.C.2    Mattos Mda, G.3    Ribeiro, R.F.4
  • 29
    • 2642580595 scopus 로고    scopus 로고
    • In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures
    • Koke U, Wolf A, Lenz P, Gilde H. In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures. J Oral Rehabil 2004;31:477-482.
    • (2004) J Oral Rehabil , vol.31 , pp. 477-482
    • Koke, U.1    Wolf, A.2    Lenz, P.3    Gilde, H.4
  • 30
    • 0030226140 scopus 로고    scopus 로고
    • Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant-supported fixed prosthesis
    • Clelland NL, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont 1996;5:193-200.
    • (1996) J Prosthodont , vol.5 , pp. 193-200
    • Clelland, N.L.1    Carr, A.B.2    Gilat, A.3
  • 31
    • 0038488528 scopus 로고    scopus 로고
    • Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible
    • Ortorp A, Jemt T, Bäck T, Jälevik T. Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. Int J Prosthodont 2003;16:194-200.
    • (2003) Int J Prosthodont , vol.16 , pp. 194-200
    • Ortorp, A.1    Jemt, T.2    Bäck, T.3    Jälevik, T.4
  • 32
    • 0031262117 scopus 로고    scopus 로고
    • Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks
    • Clelland NL, van Putten MC. Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks. Int J Oral Maxillofac Implants 1997;12:793-799.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 793-799
    • Clelland, N.L.1    van Putten, M.C.2
  • 33
    • 4644336254 scopus 로고    scopus 로고
    • Cement fixation and screw retention: Parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures
    • Heckmann SM, Karl M, Wichmann MG, Winter W, Graef F, Taylor TD. Cement fixation and screw retention: Parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures. Clin Oral Implants Res 2004;15:466-473.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 466-473
    • Heckmann, S.M.1    Karl, M.2    Wichmann, M.G.3    Winter, W.4    Graef, F.5    Taylor, T.D.6
  • 34
    • 15944423262 scopus 로고    scopus 로고
    • Static implant loading caused by as-cast metal and ceramic-veneered superstructures
    • Karl M, Rosch S, Graef F, Taylor TD, Heckmann SM. Static implant loading caused by as-cast metal and ceramic-veneered superstructures. J Prosthet Dent 2005;93:324-330.
    • (2005) J Prosthet Dent , vol.93 , pp. 324-330
    • Karl, M.1    Rosch, S.2    Graef, F.3    Taylor, T.D.4    Heckmann, S.M.5
  • 35
    • 0142024931 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: A critical review
    • Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: A critical review. Int J Oral Maxillofac Implants 2003;18:719-728.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 719-728
    • Michalakis, K.X.1    Hirayama, H.2    Garefis, P.D.3
  • 36
    • 0036550139 scopus 로고    scopus 로고
    • Alloys for prosthodontic restorations
    • Wataha JC. Alloys for prosthodontic restorations. J Prosthet Dent 2002;87:351-363.
    • (2002) J Prosthet Dent , vol.87 , pp. 351-363
    • Wataha, J.C.1
  • 37
    • 0030238164 scopus 로고    scopus 로고
    • Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders
    • Carr AB, Brunski JB, Hurley E. Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders. Int J Oral Maxillofac Implants 1996;11:589-598.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 589-598
    • Carr, A.B.1    Brunski, J.B.2    Hurley, E.3
  • 38
    • 33645959184 scopus 로고    scopus 로고
    • Effect of casting procedures on screw loosening in UCLA-type abutments
    • Kano SC, Binon P, Bonfante G, Curtis DA. Effect of casting procedures on screw loosening in UCLA-type abutments. J Prosthodont 2006;15:77-81.
    • (2006) J Prosthodont , vol.15 , pp. 77-81
    • Kano, S.C.1    Binon, P.2    Bonfante, G.3    Curtis, D.A.4
  • 39
    • 0020725719 scopus 로고
    • Nonprecious alloys for use in fixed prosthodontics:A literature review
    • Kelly JR, Rose TC. Nonprecious alloys for use in fixed prosthodontics:A literature review. J Prosthet Dent 1983;49:363-370.
    • (1983) J Prosthet Dent , vol.49 , pp. 363-370
    • Kelly, J.R.1    Rose, T.C.2
  • 40
    • 0030155746 scopus 로고    scopus 로고
    • Titanium for prosthodontic applications:A review of the literature
    • Wang RR, Fenton A. Titanium for prosthodontic applications:A review of the literature. Quintessence Int 1996;27:401-408.
    • (1996) Quintessence Int , vol.27 , pp. 401-408
    • Wang, R.R.1    Fenton, A.2
  • 41
    • 0022118623 scopus 로고
    • Titanium: The mystery metal of implant dentistry. Dental materials aspects
    • Parr GR, Gardner LK, Toth RW. Titanium: The mystery metal of implant dentistry. Dental materials aspects. J Prosthet Dent 1985;54:410-414.
    • (1985) J Prosthet Dent , vol.54 , pp. 410-414
    • Parr, G.R.1    Gardner, L.K.2    Toth, R.W.3
  • 42
    • 0027616999 scopus 로고
    • Titanium and titanium alloys as dental materials
    • Lautenschlager EP, Monaghan P. Titanium and titanium alloys as dental materials. Int Dent J 1993;43:245-253.
    • (1993) Int Dent J , vol.43 , pp. 245-253
    • Lautenschlager, E.P.1    Monaghan, P.2
  • 43
    • 0029178725 scopus 로고
    • Titanium framework removable partial denture used for patient allergic to other metals: A clinical report and literature review
    • Könönen M, Rintanen J, Waltimo A, Kempainen P. Titanium framework removable partial denture used for patient allergic to other metals: A clinical report and literature review. J Prosthet Dent 1995;73:4-7.
    • (1995) J Prosthet Dent , vol.73 , pp. 4-7
    • Könönen, M.1    Rintanen, J.2    Waltimo, A.3    Kempainen, P.4
  • 44
    • 0036834297 scopus 로고    scopus 로고
    • Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining
    • Contreras EF, Henriques GE, Giolo SR, Nobilo MA. Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining. J Prosthet Dent 2002;88:467-472.
    • (2002) J Prosthet Dent , vol.88 , pp. 467-472
    • Contreras, E.F.1    Henriques, G.E.2    Giolo, S.R.3    Nobilo, M.A.4
  • 45
    • 0036725623 scopus 로고    scopus 로고
    • Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures
    • Rodrigues RC, Ribeiro RF, de Mattos Mda G, Bezzon OL. Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures. J Prosthet Dent 2002;88:290-296.
    • (2002) J Prosthet Dent , vol.88 , pp. 290-296
    • Rodrigues, R.C.1    Ribeiro, R.F.2    de Mattos Mda, G.3    Bezzon, O.L.4
  • 46
    • 0026248512 scopus 로고
    • Corrosion properties of soldered joints. Part II: Corrosion pattern of dental solder and dental nickel-chromium alloy
    • Shigeto N, Yanagihara T, Murakami S, Hamada T. Corrosion properties of soldered joints. Part II: Corrosion pattern of dental solder and dental nickel-chromium alloy. J Prosthet Dent 1991; 66:607-610.
    • (1991) J Prosthet Dent , vol.66 , pp. 607-610
    • Shigeto, N.1    Yanagihara, T.2    Murakami, S.3    Hamada, T.4
  • 47
    • 0031159896 scopus 로고    scopus 로고
    • Mechanical and elemental characterization of solder joints and welds using a gold-palladium alloy
    • Wiskott HW, Macheret F, Bussy F, Belser UC. Mechanical and elemental characterization of solder joints and welds using a gold-palladium alloy. J Prosthet Dent 1997;77:607-616.
    • (1997) J Prosthet Dent , vol.77 , pp. 607-616
    • Wiskott, H.W.1    Macheret, F.2    Bussy, F.3    Belser, U.C.4
  • 49
    • 70449412468 scopus 로고    scopus 로고
    • Early laser-welded titanium frameworks supported by implants in the edentulous mandible: A 15-year comparative follow-up study
    • Ortorp A, Jemt T. Early laser-welded titanium frameworks supported by implants in the edentulous mandible: A 15-year comparative follow-up study. Clin Implant Dent Relat Res 2009; 11:311-322.
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 311-322
    • Ortorp, A.1    Jemt, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.