메뉴 건너뛰기




Volumn 18, Issue 3, 2009, Pages 230-234

An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis

Author keywords

Casting; Implant supported; Laser welding; Passivity; Prosthetic misfit

Indexed keywords

CHROMIUM DERIVATIVE;

EID: 64149092711     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2008.00405.x     Document Type: Article
Times cited : (12)

References (21)
  • 1
    • 0028522448 scopus 로고
    • A new method to routinely achieve passive fit of ceramometal prostheses over Bränemark osseointegrated implants: A two-year report
    • Aparicio C : A new method to routinely achieve passive fit of ceramometal prostheses over Bränemark osseointegrated implants: a two-year report. Int J Periodontics Restorative Dent 1994 14 : 405 419
    • (1994) Int J Periodontics Restorative Dent , vol.14 , pp. 405-419
    • Aparicio, C.1
  • 2
    • 0032617145 scopus 로고    scopus 로고
    • Microleakage at the abutment-implant interface of osseointegrated implants: A comparative study
    • Gross M, Abramovich I, Weiss EI : Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants 1999 14 : 94 100
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 94-100
    • Gross, M.1    Abramovich, I.2    Weiss, E.I.3
  • 3
    • 0034573540 scopus 로고    scopus 로고
    • Biological complications if dental implants: Their prevention, diagnosis and treatment
    • Lang NP, Wilson TG, Cobert EF : Biological complications if dental implants: their prevention, diagnosis and treatment. Clin Oral Impl Res 2000 11 : 146 155
    • (2000) Clin Oral Impl Res , vol.11 , pp. 146-155
    • Lang, N.P.1    Wilson, T.G.2    Cobert, E.F.3
  • 4
    • 0035223781 scopus 로고    scopus 로고
    • The significance of passive framework fit in implant prosthodontics: Current status
    • Sahin S, Cehreli MC : The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 2001 10 : 85 90
    • (2001) Implant Dent , vol.10 , pp. 85-90
    • Sahin, S.1    Cehreli, M.C.2
  • 5
    • 0021776981 scopus 로고
    • Design of superstructures for osseointegrated fixtures
    • Klineberg IJ, Murray GM : Design of superstructures for osseointegrated fixtures. Swed Dent J 1985 28 : 53 69
    • (1985) Swed Dent J , vol.28 , pp. 53-69
    • Klineberg, I.J.1    Murray, G.M.2
  • 6
    • 0142140032 scopus 로고
    • How do you test a cast framework fit for a full arch fixed implant-supported prosthesis? Current Issues Forum
    • Yanase RT, Binon PP, Jemt T, et al : How do you test a cast framework fit for a full arch fixed implant-supported prosthesis? Current Issues Forum. Int J Oral Maxillofac Implants 1994 9 : 469 474
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 469-474
    • Yanase, R.T.1    Binon, P.P.2    Jemt, T.3    Al, E.4
  • 7
    • 0035836204 scopus 로고    scopus 로고
    • The laser welding technique applied to the non precious dental alloys procedure and results
    • Bertrand C, Le Petitcorps Y, Albingre L, et al : The laser welding technique applied to the non precious dental alloys procedure and results. Br Dent J 2001 190 : 255 257
    • (2001) Br Dent J , vol.190 , pp. 255-257
    • Bertrand, C.1    Le Petitcorps, Y.2    Albingre, L.3    Al, E.4
  • 8
    • 0036497572 scopus 로고    scopus 로고
    • Joint strength of laser-welded titanium
    • Liu J, Watanabe I, Yoshida K, et al : Joint strength of laser-welded titanium. Dent Mater 2002 18 : 143 148
    • (2002) Dent Mater , vol.18 , pp. 143-148
    • Liu, J.1    Watanabe, I.2    Yoshida, K.3    Al, E.4
  • 9
    • 4143149751 scopus 로고    scopus 로고
    • In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion
    • Sartori IAM, Ribeiro RF, Francischone CE, et al : In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion. J Prosthet Dent 2004 92 : 132 138
    • (2004) J Prosthet Dent , vol.92 , pp. 132-138
    • Sartori, I.A.M.1    Ribeiro, R.F.2    Francischone, C.E.3    Al, E.4
  • 10
    • 0038505307 scopus 로고    scopus 로고
    • Cyclic loading of implant-supported prostheses: Changes in component fit over time
    • Hecker DM, Eckert SE : Cyclic loading of implant-supported prostheses: changes in component fit over time. J Prosthet Dent 2003 89 : 346 351
    • (2003) J Prosthet Dent , vol.89 , pp. 346-351
    • Hecker, D.M.1    Eckert, S.E.2
  • 11
    • 42449090241 scopus 로고    scopus 로고
    • Implant retained suprastructures passivated to a stress free fit through spark erosion
    • Eisenman E : Implant retained suprastructures passivated to a stress free fit through spark erosion. Quintessenz Zahntechnik Implantologie 1997 2 : 1440 1997
    • (1997) Quintessenz Zahntechnik Implantologie , vol.2 , pp. 1440-1997
    • Eisenman, E.1
  • 12
    • 0027572474 scopus 로고
    • Studies on laser-and plasma-welded titanium
    • Roggensack M, Walter MH, Boning KW : Studies on laser-and plasma-welded titanium. Dent Mater 1993 9 : 104 107
    • (1993) Dent Mater , vol.9 , pp. 104-107
    • Roggensack, M.1    Walter, M.H.2    Boning, K.W.3
  • 13
    • 0033182713 scopus 로고    scopus 로고
    • Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings
    • Zervas PJ, Papazoglou E, Beck FM, et al : Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings. J Prosthodont 1999 8 : 171 179
    • (1999) J Prosthodont , vol.8 , pp. 171-179
    • Zervas, P.J.1    Papazoglou, E.2    Beck, F.M.3    Al, E.4
  • 14
    • 0030227163 scopus 로고    scopus 로고
    • Accuracy of wax, autopolymerized, and light-polymerized resin pattern materials
    • Iglesias A, Powers JM, Pierpont HP : Accuracy of wax, autopolymerized, and light-polymerized resin pattern materials. J Prosthodont 1996 5 : 201 205
    • (1996) J Prosthodont , vol.5 , pp. 201-205
    • Iglesias, A.1    Powers, J.M.2    Pierpont, H.P.3
  • 15
    • 0030144030 scopus 로고    scopus 로고
    • Marginal discrepancy of ceramic crowns with redesigned implant components
    • Sutherland JK, Loney RW, Jarotskic TJ : Marginal discrepancy of ceramic crowns with redesigned implant components. J Prosthet Dent 1996 75 : 540 544
    • (1996) J Prosthet Dent , vol.75 , pp. 540-544
    • Sutherland, J.K.1    Loney, R.W.2    Jarotskic, T.J.3
  • 16
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Bränemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T : Failures and complications in 391 consecutively inserted fixed prostheses supported by Bränemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxilofac Implants 1991 6 : 270 276
    • (1991) Int J Oral Maxilofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 17
    • 0031301642 scopus 로고    scopus 로고
    • Fit of implant frameworks fabricated by different techniques
    • Riedy SJ, Lang BR, Lang BE : Fit of implant frameworks fabricated by different techniques. J Prosthet Dent 1997 78 : 596 604
    • (1997) J Prosthet Dent , vol.78 , pp. 596-604
    • Riedy, S.J.1    Lang, B.R.2    Lang, B.E.3
  • 18
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C : Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994 9 : 169 178
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 19
    • 0030236468 scopus 로고    scopus 로고
    • An analysis and management of fractured implants: A clinical report
    • Balshi TJ : An analysis and management of fractured implants: a clinical report. Int J Oral Maxillofac Implants 1996 11 : 660 666
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 660-666
    • Balshi, T.J.1
  • 20
    • 0031066345 scopus 로고    scopus 로고
    • Correcting the fit of implant retained restorations by electric discharge machining
    • Evans DB : Correcting the fit of implant retained restorations by electric discharge machining. J Prosthet Dent 1997 77 : 212 215
    • (1997) J Prosthet Dent , vol.77 , pp. 212-215
    • Evans, D.B.1
  • 21
    • 0142024931 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: A critical review
    • Michalakis KX, Hirayama H, Garefis PD : Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003 18 : 719 728
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 719-728
    • Michalakis, K.X.1    Hirayama, H.2    Garefis, P.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.