메뉴 건너뛰기




Volumn 88, Issue 5, 2002, Pages 467-472

Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; ALUMINUM; COPPER; PALLADIUM; SILVER; TITANIUM; BIOMEDICAL AND DENTAL MATERIALS; DENTAL ALLOY; TITANIUM ALLOY (TIAL6V4);

EID: 0036834297     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1067/mpr.2002.128954     Document Type: Article
Times cited : (35)

References (28)
  • 1
    • 0026494584 scopus 로고
    • The castability of unalloyed titanium in three different casting machines
    • Bessing C, Bergman M. The castability of unalloyed titanium in three different casting machines. Swed Dent J 1992;16:109-13.
    • (1992) Swed Dent J , vol.16 , pp. 109-113
    • Bessing, C.1    Bergman, M.2
  • 2
    • 0029382149 scopus 로고
    • Casting of Ti-6Al-4V alloy compared with pure Ti in an Ar-arc casting machine
    • Syverud M, Okabe T, Hero H. Casting of Ti-6Al-4V alloy compared with pure Ti in an Ar-arc casting machine. Eur J Oral Sci 1995;103:327-30.
    • (1995) Eur J Oral Sci , vol.103 , pp. 327-330
    • Syverud, M.1    Okabe, T.2    Hero, H.3
  • 3
    • 0027616999 scopus 로고
    • Titanium and titanium alloys as dental materials
    • Lautenschlager EP, Monaghan P. Titanium and titanium alloys as dental materials. Int Dent J 1993;43:245-53.
    • (1993) Int Dent J , vol.43 , pp. 245-253
    • Lautenschlager, E.P.1    Monaghan, P.2
  • 4
    • 0026922624 scopus 로고
    • Biodegradation of restorative metallic systems
    • Lucas LC, Lemons JE. Biodegradation of restorative metallic systems. Adv Dent Res 1992;6:32-7.
    • (1992) Adv Dent Res , vol.6 , pp. 32-37
    • Lucas, L.C.1    Lemons, J.E.2
  • 5
    • 0030155746 scopus 로고    scopus 로고
    • Titanium for prosthodontic applications: A review of the literature
    • Wang RR, Fenton A. Titanium for prosthodontic applications: a review of the literature. Quintessence Int 1996;27:401-8.
    • (1996) Quintessence Int , vol.27 , pp. 401-408
    • Wang, R.R.1    Fenton, A.2
  • 6
    • 0034276711 scopus 로고    scopus 로고
    • Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments
    • Zavanelli RA, Pessanha Henriques CE, Ferreira I, De Almeida Rollo JM. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments. J Prosthet Dent 2000;84:274-9.
    • (2000) J Prosthet Dent , vol.84 , pp. 274-279
    • Zavanelli, R.A.1    Pessanha Henriques, C.E.2    Ferreira, I.3    De Almeida Rollo, J.M.4
  • 7
    • 0028711071 scopus 로고
    • Clinical performance of machined titanium restorations
    • Walter M, Boning K, Reppel PD. Clinical performance of machined titanium restorations. J Dent 1994;22:346-8.
    • (1994) J Dent , vol.22 , pp. 346-348
    • Walter, M.1    Boning, K.2    Reppel, P.D.3
  • 8
    • 0026860865 scopus 로고
    • Non-cast titanium restorations in fixed prosthodontics
    • Böening KW, Walter MH, Reppel PD. Non-cast titanium restorations in fixed prosthodontics. J Oral Rehabil 1992;19:281-7.
    • (1992) J Oral Rehabil , vol.19 , pp. 281-287
    • Böening, K.W.1    Walter, M.H.2    Reppel, P.D.3
  • 9
    • 0035347819 scopus 로고    scopus 로고
    • Marginal adaptation of cast partial crowns made of pure titanium and a gold alloy under influence of a manual burnishing technique
    • Stoll R, Makris P, Stachniss V. Marginal adaptation of cast partial crowns made of pure titanium and a gold alloy under influence of a manual burnishing technique. J Oral Rehabil 2001;28:401-6.
    • (2001) J Oral Rehabil , vol.28 , pp. 401-406
    • Stoll, R.1    Makris, P.2    Stachniss, V.3
  • 10
    • 0026825389 scopus 로고
    • Electrical discharge machining in dentistry
    • Van Roekel NB. Electrical discharge machining in dentistry. Int J Prosthodont 1992;5:114-21.
    • (1992) Int J Prosthodont , vol.5 , pp. 114-121
    • Van Roekel, N.B.1
  • 11
    • 0026832539 scopus 로고
    • Prosthesis fabrication using electrical discharge machining
    • Van Roekel NB. Prosthesis fabrication using electrical discharge machining. Int J Oral Maxillofac Implants 1992;7:56-61.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 56-61
    • Van Roekel, N.B.1
  • 12
    • 0031066345 scopus 로고    scopus 로고
    • Correcting the fit of implant-retained restorations by electric discharge machining
    • Evans DB. Correcting the fit of implant-retained restorations by electric discharge machining. J Prosthet Dent 1997;77:212-5.
    • (1997) J Prosthet Dent , vol.77 , pp. 212-215
    • Evans, D.B.1
  • 13
    • 0029262522 scopus 로고
    • Refining cast implant-retained restorations by electrical discharge machining
    • Schmitt SM, Chance DA, Cronin RJ. Refining cast implant-retained restorations by electrical discharge machining. J Prosthet Dent 1995;73:280-3.
    • (1995) J Prosthet Dent , vol.73 , pp. 280-283
    • Schmitt, S.M.1    Chance, D.A.2    Cronin, R.J.3
  • 14
    • 0029338110 scopus 로고
    • Fabrication of titanium implant-retained restorations with nontraditional machining techniques
    • Schmitt SM, Chance DA. Fabrication of titanium implant-retained restorations with nontraditional machining techniques. Int J Prosthodont 1995;8:332-6.
    • (1995) Int J Prosthodont , vol.8 , pp. 332-336
    • Schmitt, S.M.1    Chance, D.A.2
  • 15
    • 0027630884 scopus 로고
    • Development of fabrication system of prostheses using electric discharge machining
    • Miyazaki T, Kitamura M, Hotta Y, Lee G. Development of fabrication system of prostheses using electric discharge machining. Asian J Aesthet Dent 1993;1:71-9.
    • (1993) Asian J Aesthet Dent , vol.1 , pp. 71-79
    • Miyazaki, T.1    Kitamura, M.2    Hotta, Y.3    Lee, G.4
  • 16
    • 0020451872 scopus 로고
    • Electroerosion in dental technology. Possibilities and limits
    • German
    • Rubeling G. Electroerosion in dental technology. Possibilities and limits. Dent Labor 1982;30:1697-702. German.
    • (1982) Dent Labor , vol.30 , pp. 1697-1702
    • Rubeling, G.1
  • 18
    • 0027620312 scopus 로고
    • The fit of Procera titanium crowns. An in vitro and clinical study
    • Karlsson S. The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 1993;51:129-34.
    • (1993) Acta Odontol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 19
    • 0028506796 scopus 로고
    • Marginal fit of machine-milled titanium and cast titanium single crowns
    • Leong D, Chai J, Lautenschlager E, Gilbert J. Marginal fit of machine-milled titanium and cast titanium single crowns. Int J Prosthodont 1994;7:440-7.
    • (1994) Int J Prosthodont , vol.7 , pp. 440-447
    • Leong, D.1    Chai, J.2    Lautenschlager, E.3    Gilbert, J.4
  • 20
    • 0031093014 scopus 로고    scopus 로고
    • Dentists' opinions on aspects of cast titanium restorations
    • Berg E. Dentists' opinions on aspects of cast titanium restorations. J Dent 1997;25:113-7.
    • (1997) J Dent , vol.25 , pp. 113-117
    • Berg, E.1
  • 21
    • 0028457325 scopus 로고
    • Passive fit of implant-retained prosthetic superstructures improved by electrical discharge machining
    • Linehan AD, Windeler AS. Passive fit of implant-retained prosthetic superstructures improved by electrical discharge machining. J Prosthodont 1994;3:88-95.
    • (1994) J Prosthodont , vol.3 , pp. 88-95
    • Linehan, A.D.1    Windeler, A.S.2
  • 22
    • 0026845341 scopus 로고
    • Marginal accuracy and geometry of cast titanium copings
    • Blackman R, Baez R, Barghi N. Marginal accuracy and geometry of cast titanium copings. J Prosthet Dent 1992;67:435-40.
    • (1992) J Prosthet Dent , vol.67 , pp. 435-440
    • Blackman, R.1    Baez, R.2    Barghi, N.3
  • 23
    • 0027142077 scopus 로고
    • Mold filing and porosity in castings of titanium
    • Hero H, Syverud M, Waarli M. Mold filing and porosity in castings of titanium. Dent Mater 1993;9:15-8.
    • (1993) Dent Mater , vol.9 , pp. 15-18
    • Hero, H.1    Syverud, M.2    Waarli, M.3
  • 25
    • 0031203639 scopus 로고    scopus 로고
    • Soldering and remelting influence on fatigue strength of cobalt-chromium alloys
    • Henriques GE, Consani S, Rollo JM, Andrade e Silva F. Soldering and remelting influence on fatigue strength of cobalt-chromium alloys. J Prosthet Dent 1997;78:146-52.
    • (1997) J Prosthet Dent , vol.78 , pp. 146-152
    • Henriques, G.E.1    Consani, S.2    Rollo, J.M.3    Andrade E Silva, F.4
  • 26
    • 0029301130 scopus 로고
    • A CAD/CAM system for the production of metal copings for porcelain-fused-to-metal restorations
    • Samet N, Resheff B, Gelbard S, Stern N. A CAD/CAM system for the production of metal copings for porcelain-fused-to-metal restorations. J Prosthet Dent 1995;73:457-63.
    • (1995) J Prosthet Dent , vol.73 , pp. 457-463
    • Samet, N.1    Resheff, B.2    Gelbard, S.3    Stern, N.4
  • 27
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-11.
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    Von Fraunhofer, J.A.2
  • 28
    • 0022139299 scopus 로고
    • The fit of metal-ceramic crowns, a clinical study
    • Fransson B, Oilo G, Gjeitanger R. The fit of metal-ceramic crowns, a clinical study. Dent Mater 1985;1:197-9.
    • (1985) Dent Mater , vol.1 , pp. 197-199
    • Fransson, B.1    Oilo, G.2    Gjeitanger, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.