메뉴 건너뛰기




Volumn 38, Issue 6, 2011, Pages 2975-2985

Sub-Nyquist acquisition and constrained reconstruction in time resolved angiography

Author keywords

4D x ray DSA; accelerated imaging; constrained reconstruction; HYPR; MR DSA; undersampled acquisition; VIPR

Indexed keywords

ANGIOGRAPHY; ROBOTIC ARMS; TIME SERIES; X RAYS;

EID: 79958851867     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3589132     Document Type: Article
Times cited : (26)

References (71)
  • 3
    • 37549035028 scopus 로고    scopus 로고
    • Iterative reconstruction of time-resolved images using highly constrained back-projection (HYPR)
    • 10.1002/mrm.v59:1
    • R. L. O'Halloran, Z. Wen, J. H. Holmes, and S. B. Fain, " Iterative reconstruction of time-resolved images using highly constrained back-projection (HYPR).," Magn. Reson. Med. 59, 132-139 (2008). 10.1002/mrm.v59:1
    • (2008) Magn. Reson. Med. , vol.59 , pp. 132-139
    • O'Halloran, R.L.1    Wen, Z.2    Holmes, J.H.3    Fain, S.B.4
  • 5
    • 37549061019 scopus 로고    scopus 로고
    • More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization
    • Basel, Switzerland.
    • M. Griswold, " More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization.," Abstract, 18th International Workshop on MR Angiography, Basel, Switzerland (2006).
    • (2006) Abstract, 18th International Workshop on MR Angiography
    • Griswold, M.1
  • 8
    • 0015969976 scopus 로고
    • An inexpensive storage system for selective catheterization procedures
    • 10.1148/110.2.3 79
    • A. B. Crummy, C. A. Mistretta, R. Cline, W. Terry, M. G. Ort, F. Kelcz, and J. R. Cameron, " An inexpensive storage system for selective catheterization procedures.," Radiology 110, 369-372 (1973). 10.1148/110.2.3 79
    • (1973) Radiology , vol.110 , pp. 369-372
    • Crummy, A.B.1    Mistretta, C.A.2    Cline, R.3    Terry, W.4    Ort, M.G.5    Kelcz, F.6    Cameron, J.R.7
  • 10
    • 0017129244 scopus 로고
    • Absorption edge fluoroscopy using a 3-spectrum technique
    • 10.1118/1.594219
    • F. Kelcz and C. A. Mistretta, " Absorption edge fluoroscopy using a 3-spectrum technique.," Med. Phys. 3 (3), 159-168 (1977). 10.1118/1.594219
    • (1977) Med. Phys. , vol.3 , Issue.3 , pp. 159-168
    • Kelcz, F.1    Mistretta, C.A.2
  • 11
    • 79958854720 scopus 로고
    • Development of a digital subtraction system for intravenous angiography
    • T. W. Ovitt, " Development of a digital subtraction system for intravenous angiography.," Proc. SPIE, 206, 183-189 (1979).
    • (1979) Proc. SPIE , vol.206 , pp. 183-189
    • Ovitt, T.W.1
  • 12
    • 2342485317 scopus 로고
    • Computerized video-image preprocessing with applications to cardio-angiographic roentgen-image series
    • in, edited by H. H Nagel (Springer-Verlag, Berlin)
    • R. Brennecke, " Computerized video-image preprocessing with applications to cardio-angiographic roentgen-image series.," in Digital Image Processing, edited by, H. H Nagel, (Springer-Verlag, Berlin, 1977), pp. 244-262.
    • (1977) Digital Image Processing , pp. 244-262
    • Brennecke, R.1
  • 13
    • 0026564750 scopus 로고
    • Arteriographic complications in the DSA era
    • J. R. Waugh and N. Sacharias, " Arteriographic complications in the DSA era.," Radiology 182, 243-246 (1992).
    • (1992) Radiology , vol.182 , pp. 243-246
    • Waugh, J.R.1    Sacharias, N.2
  • 14
    • 0019780775 scopus 로고
    • Hybrid subtraction for improved arteriography
    • W. R. Brody, " Hybrid subtraction for improved arteriography.," Radiology 141 (3), 828-831 (1981). (Pubitemid 12252232)
    • (1981) Radiology , vol.141 , Issue.3 , pp. 828-831
    • Brody, W.R.1
  • 15
    • 0031546042 scopus 로고    scopus 로고
    • Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results
    • R. Fahrig, A. J. Fox, S. Lownie, and D. W. Holdsworth, " Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results.," AJNR Am J Neuroradiol. 18 (8), 1507-1514 (1997). (Pubitemid 30413966)
    • (1997) American Journal of Neuroradiology , vol.18 , Issue.8 , pp. 1507-1514
    • Fahrig, R.1    Fox, A.J.2    Lownie, S.3    Holdsworth, D.W.4
  • 16
    • 0030742408 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
    • DOI 10.1118/1.598013
    • R. Fahrig, M. Moreau, and D. W. Holdsworth, " Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion.," Med. Phys. 24 (7), 1097-10106 (1997) 10.1118/1.598013 (Pubitemid 27306632)
    • (1997) Medical Physics , vol.24 , Issue.7 , pp. 1097-1106
    • Fahrig, R.1    Moreau, M.2    Holdsworth, D.W.3
  • 17
    • 0033954113 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities
    • DOI 10.1118/1.598854
    • R. Fahrig and D. W. Holdsworth, " Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion non-idealities.," Med. Phys. 27, 30-38 (2000). 10.1118/1.598854 (Pubitemid 30051908)
    • (2000) Medical Physics , vol.27 , Issue.1 , pp. 30-38
    • Fahrig, R.1    Holdsworth, D.W.2
  • 18
    • 0027633059 scopus 로고
    • Keyhole method for accelerating imaging of contrast agent uptake
    • 10.1002/jmri.v3:4
    • J. Van Vaals, " Keyhole method for accelerating imaging of contrast agent uptake.," J. Magn. Reson. Imaging 3, 671-675 (1993). 10.1002/jmri.v3:4
    • (1993) J. Magn. Reson. Imaging , vol.3 , pp. 671-675
    • Van Vaals, J.1
  • 20
    • 73949112471 scopus 로고    scopus 로고
    • Peripheral vasculature: High temporal- and spatial-resolution three-dimensional contrast-enhnaced MR Angiography
    • 10.1148/radiol.2533081744
    • C. R. Haider, J. Glockner, A. W. Stanson, and S. Reiderer, " Peripheral vasculature: High temporal- and spatial-resolution three-dimensional contrast-enhnaced MR Angiography.," Radiology 253, 831-843 (2009). 10.1148/radiol.2533081744
    • (2009) Radiology , vol.253 , pp. 831-843
    • Haider, C.R.1    Glockner, J.2    Stanson, A.W.3    Reiderer, S.4
  • 21
    • 77956361595 scopus 로고    scopus 로고
    • Time-resolved bolus chase MR angiography with real-time triggering of table motion
    • 10.1002/mrm.22537
    • C. P. Johnson, C. R. Haider, E. A. Borish, J. F. Glockner, and S. J. Riederer, " Time-resolved bolus chase MR angiography with real-time triggering of table motion.," Magn. Reson. Med. 64, 629-637 (2010). 10.1002/mrm.22537
    • (2010) Magn. Reson. Med. , vol.64 , pp. 629-637
    • Johnson, C.P.1    Haider, C.R.2    Borish, E.A.3    Glockner, J.F.4    Riederer, S.J.5
  • 22
    • 84870968925 scopus 로고    scopus 로고
    • Interleaved variable density sampling with ARC parallel imaging and Cartesian HYPR for dynamic MR angiography
    • Stockholm.
    • K. Wang, " Interleaved variable density sampling with ARC parallel imaging and Cartesian HYPR for dynamic MR angiography.," Proceedings of the Joint Annual Meeting of ISMRM-ESMRMB (abstract), Stockholm, 2010.
    • (2010) Proceedings of the Joint Annual Meeting of ISMRM-ESMRMB (Abstract)
    • Wang, K.1
  • 23
    • 0028803115 scopus 로고
    • Continuous radial acquisition for dynamic MRI
    • 10.1002/mrm.v34:5
    • V. Rasche, R. W. deBoer, D. Holz, and R. Proska, " Continuous radial acquisition for dynamic MRI.," Magn. Reson. Med. 34, 754-761 (1995). 10.1002/mrm.v34:5
    • (1995) Magn. Reson. Med. , vol.34 , pp. 754-761
    • Rasche, V.1    Deboer, R.W.2    Holz, D.3    Proska, R.4
  • 24
    • 0031850913 scopus 로고    scopus 로고
    • Reduced circular field-of-view imaging
    • K. Scheffler and J. Hennig, " Reduced circular field of view imaging.," Magn. Reson. Med. 40, 474-480 (1998). 10.1002/mrm.v40:3 (Pubitemid 28391910)
    • (1998) Magnetic Resonance in Medicine , vol.40 , Issue.3 , pp. 474-480
    • Scheffler, K.1    Hennig, J.2
  • 26
    • 0036319895 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • DOI 10.1002/mrm.10212
    • A. V. Barger, W. F. Block, Y. Toropov, T. M. Grist, and C. A. Mistretta, " Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory.," Magn. Reson. Med. 48, 297-305 (2002). 10.1002/mrm.v48:2 (Pubitemid 34809418)
    • (2002) Magnetic Resonance in Medicine , vol.48 , Issue.2 , pp. 297-305
    • Barger, A.V.1    Block, W.F.2    Toropov, Y.3    Grist, T.M.4    Mistretta, C.A.5
  • 27
    • 36248995983 scopus 로고    scopus 로고
    • Transstenotic pressure gradients: Measurement in swine - Retrospectively ECG-gated 3D phase-contrast MR angiography versus endovascular pressure-sensing guidewires
    • DOI 10.1148/radiol.2453061946
    • D. P. Lum, K. M. Johnson, R. K. Paul, A. S. Turk, D. W. Consigny, J. R. Grinde, C. A. Mistretta, and T. M. Grist, " Measurement of trans-stenotic pressure gradients in swine: Comparison between retrospective ECG-gated 3D phase-contrast MRA and endovascular pressure-sensing guidewires.," Radiology 245, 751-760 (2007). 10.1148/radiol.2453061946 (Pubitemid 350127345)
    • (2007) Radiology , vol.245 , Issue.3 , pp. 751-760
    • Lum, D.P.1    Johnson, K.M.2    Paul, R.K.3    Turk, A.S.4    Consigny, D.W.5    Grinde, J.R.6    Mistretta, C.A.7    Grist, T.M.8
  • 29
    • 35349022540 scopus 로고    scopus 로고
    • CT angiographic appearance of in-stent restenosis of intracranial arteries treated with the Wingspan stent
    • DOI 10.3174/ajnr.A0713
    • A. S. Turk, K. M. Johnson, L. D. Niemann, B. Aagaard-Kienitz, D. Consigny, J. Grinde, P. Turski, V. Haughton, and C. A. Mistretta, " Physiological and anatomic assessment of a canine artery stenosis model with phase contrast with vastly undersampled isotropic projection imaging.," AJNR Am. J. Neuroradiol. 28, 111-115 (2007). 10.3174/ajnr.A0713 (Pubitemid 47598154)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.9 , pp. 1752-1754
    • Turk, A.S.1    Rowley, H.A.2    Niemann, D.B.3    Fiorella, D.4    Aagaard-Kienitz, B.5    Pulfer, K.6    Strother, C.M.7
  • 31
    • 79952261074 scopus 로고    scopus 로고
    • In vivo 3-dimensional magnetic resonance wall shear stress estimation in ascending aortic dilatation
    • 10.1002/jmri.22485
    • E. T. Bieging, A. Frydrychowicz, B. R. Landgraf, K. M. Johnson, O. Wieben, and C. J. Fraņois, " In vivo 3-dimensional magnetic resonance wall shear stress estimation in ascending aortic dilatation.," J. Magn. Reson. Imaging 33 (3), 589-597 (2011). 10.1002/jmri.22485
    • (2011) J. Magn. Reson. Imaging , vol.33 , Issue.3 , pp. 589-597
    • Bieging, E.T.1    Frydrychowicz, A.2    Landgraf, B.R.3    Johnson, K.M.4    Wieben, O.5    Fraņois, C.J.6
  • 32
    • 36248993022 scopus 로고    scopus 로고
    • Science to practice: Is there replacement for percentage stenosis in characterizing occlusive vascular disease?
    • DOI 10.1148/radiol.2453071331
    • M. R. Prince, " Science to practice: Is there a replacement for percentage stenosisn characterizing occlusive vascular disease?," Radiology 245 (3) 617-618 (2007). 10.1148/radiol.2453071331 (Pubitemid 350127331)
    • (2007) Radiology , vol.245 , Issue.3 , pp. 617-618
    • Prince, M.R.1
  • 33
    • 78651496022 scopus 로고    scopus 로고
    • Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: Comparison with transcranial doppler sonography and 2D phase-contrast MR imaging
    • W. Chang, B. Landgraf, K. M. Johnson, S. Kecskemeti, Y. Wu, J. Velikina, H. Rowley, O. Wieben, C. Mistretta, and P. Turski, " Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: Comparison with transcranial doppler sonography and 2D phase-contrast MR imaging.," AJNR Am J Neuroradiol. 32 (1), 54-59 (2010).
    • (2010) AJNR Am J Neuroradiol. , vol.32 , Issue.1 , pp. 54-59
    • Chang, W.1    Landgraf, B.2    Johnson, K.M.3    Kecskemeti, S.4    Wu, Y.5    Velikina, J.6    Rowley, H.7    Wieben, O.8    Mistretta, C.9    Turski, P.10
  • 34
    • 78650629874 scopus 로고    scopus 로고
    • Renal arteries: Isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast
    • 10.1148/radiol.10100443
    • C. J. Francois, D. P. Lum, K. M. Johnson, B. R. Landgraf, T. A. Bley, S. B. Reeder, M. L. Schiebler, T. M. Grist, and O. Wieben, " Renal arteries: Isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast.," Radiology 258 (1), 254-260 (2011). 10.1148/radiol.10100443
    • (2011) Radiology , vol.258 , Issue.1 , pp. 254-260
    • Francois, C.J.1    Lum, D.P.2    Johnson, K.M.3    Landgraf, B.R.4    Bley, T.A.5    Reeder, S.B.6    Schiebler, M.L.7    Grist, T.M.8    Wieben, O.9
  • 35
    • 77951519360 scopus 로고    scopus 로고
    • Whole-heart coronary magnetic resonance angiography at 3.0T using short-TR steady-state free precession, vastly undersampled isotropic projection reconstruction
    • 10.1002/jmri.22140
    • J. Xie, P. Lai, H. Bhat, and D. J. Li, " Whole-heart coronary magnetic resonance angiography at 3.0T using short-TR steady-state free precession, vastly undersampled isotropic projection reconstruction.," Magn. Reson. Imaging 31 (5), 1230-1235 (2010). 10.1002/jmri.22140
    • (2010) Magn. Reson. Imaging , vol.31 , Issue.5 , pp. 1230-1235
    • Xie, J.1    Lai, P.2    Bhat, H.3    Li, D.J.4
  • 36
    • 77953758086 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Scimitar syndrome: Added value by isotropic flow-sensitive four-dimensional magnetic resonance imaging with PC-VIPR (phase-contrast vastly undersampled isotropic projection reconstruction)
    • 10.1161/CIRCULATIONAHA.109.931857
    • A. Frydrychowicz, B. Landgraf, O. Wieben, and C. J. Francois, " Images in cardiovascular medicine. Scimitar syndrome: Added value by isotropic flow-sensitive four-dimensional magnetic resonance imaging with PC-VIPR (phase-contrast vastly undersampled isotropic projection reconstruction).," Circulation 121, e434-6 (2010). 10.1161/CIRCULATIONAHA.109.931857
    • (2010) Circulation , vol.121 , pp. 434-436
    • Frydrychowicz, A.1    Landgraf, B.2    Wieben, O.3    Francois, C.J.4
  • 37
    • 64949151539 scopus 로고    scopus 로고
    • Vastly undersampled isotropic projection steady-state free precession imaging of the knee: Diagnostic performance compared with conventional MR
    • Smet, and, "," ,. 10.1148/radiol.2511081133
    • R. Kijowski, D. G. Blankenbaker, J. L. Klaers, K. Shinki, A. A. De Smet, and W. F. Block, " Vastly undersampled isotropic projection steady-state free precession imaging of the knee: Diagnostic performance compared with conventional MR.," Radiology 251 (1), 185-194. (2009). 10.1148/radiol. 2511081133
    • (2009) Radiology , vol.251 , Issue.1 , pp. 185-194
    • Kijowski, R.1    Blankenbaker, D.G.2    Klaers, J.L.3    Shinki, K.4    De Smet, A.A.5    Block, W.F.6
  • 38
    • 7044262262 scopus 로고    scopus 로고
    • Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction
    • DOI 10.1002/jmri.20189
    • J. Du, T. J. Carroll, E. Brodsky, A. Lu, T. M. Grist, C. A. Mistretta, and W. F. Block, " Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction.," J. Magn. Reson. Imaging 20 (5), 894-900 (2004). 10.1002/jmri.v20:5 (Pubitemid 39426088)
    • (2004) Journal of Magnetic Resonance Imaging , vol.20 , Issue.5 , pp. 894-900
    • Du, J.1    Carroll, T.J.2    Brodsky, E.3    Lu, A.4    Grist, T.M.5    Mistretta, C.A.6    Block, W.F.7
  • 39
    • 7544244928 scopus 로고    scopus 로고
    • Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion
    • 10.1002/mrm.v52:5
    • S. B. Fain, F. J. Browning, J. A. Polzin, J. Du, Y. Zhou, W. F. Block, T. M. Grist, and C. A. Mistretta, " Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion.," Magn. Reson. Med. 52 (5), 1093-10102 (2004). 10.1002/mrm.v52:5
    • (2004) Magn. Reson. Med. , vol.52 , Issue.5 , pp. 1093-10102
    • Fain, S.B.1    Browning, F.J.2    Polzin, J.A.3    Du, J.4    Zhou, Y.5    Block, W.F.6    Grist, T.M.7    Mistretta, C.A.8
  • 40
    • 0027690283 scopus 로고
    • Applications of reduced encoding MR imaging with generalized series reconstruction (RIGR)
    • 10.1002/jmri.v3:6
    • A. G. Webb, Z. P. Liang, R. I. Magin, and P. C. Lauterbur, " Applications of reduced encoding MR imaging with generalized series reconstruction (RIGR).," J. Magn. Reson. Imaging 3 (6), 925-928 (1993). 10.1002/jmri.v3:6
    • (1993) J. Magn. Reson. Imaging , vol.3 , Issue.6 , pp. 925-928
    • Webb, A.G.1    Liang, Z.P.2    Magin, R.I.3    Lauterbur, P.C.4
  • 41
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI with High Frame Rate Exploiting Spatiotemporal Correlations
    • DOI 10.1002/mrm.10611
    • J. Tsao, P. Boesiger, and K. P. Pruessmann, " k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations.," Magn. Reson. Med. 50 (5), 1031-1042 (2003). 10.1002/mrm.v50:5 (Pubitemid 37356583)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.5 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 44
    • 79952788166 scopus 로고    scopus 로고
    • Fast whole-brain 4D contrast-enhanced MR angiography with velocity encoding using undersampled radial acquisition and highly constrained projection reconstruction: Image-quality assessment in volunteer subjects
    • 10.3174/ajnr.A2022
    • Y. Wu, " Fast whole-brain 4D contrast-enhanced MR angiography with velocity encoding using undersampled radial acquisition and highly constrained projection reconstruction: Image-quality assessment in volunteer subjects.," AJNR Am. J. Neuroradiol. 32, E47-E50 (2011). 10.3174/ajnr.A2022
    • (2011) AJNR Am. J. Neuroradiol. , vol.32
    • Wu, Y.1
  • 47
    • 0021271863 scopus 로고
    • Tomographic DSA using temporal filtration: Initial neurovascular application
    • R. E. Anderson, R. A. Kruger, P. G. Sherry, J. A. Nelson, and P. Y. Liu, " Tomographic DSA using temporal filtration. Initial neurovascular applications.," AJNR 5, 277-280 (1984). (Pubitemid 14075894)
    • (1984) American Journal of Neuroradiology , vol.5 , Issue.3 , pp. 277-280
    • Anderson, R.E.1    Kruger, R.A.2    Sherry, R.G.3
  • 48
    • 0022411826 scopus 로고
    • Tomographic digital subtraction angiography: Initial clinical studies using tomosynthesis
    • N. DeVries, F. J. Miller, M. M. Wojtowycz, P. R. Brown, D. R. Yandow, J. A. Nelson, and R. A. Kruger, " Tomographic digital subtraction angiography: Initial clinical studies using tomosynthesis.," Radiology 157, 239-241 (1985). (Pubitemid 16216364)
    • (1985) Radiology , vol.157 , Issue.1 , pp. 239-241
    • De Vries, N.1    Miller, F.J.2    Wojtowycz, M.M.3
  • 49
    • 0023948897 scopus 로고
    • Computer simulation of image intensifier-based CTdetector: Vascular application
    • 10.1118/1.596250
    • R. Ning and R. A. Kruger, " Computer simulation of image intensifier-based CTdetector: Vascular application.," Med. Phys. 15 (2), 188-192 (1988). 10.1118/1.596250
    • (1988) Med. Phys. , vol.15 , Issue.2 , pp. 188-192
    • Ning, R.1    Kruger, R.A.2
  • 50
    • 34247615131 scopus 로고    scopus 로고
    • Tomographic digital subtraction angiography for lung perfusion estimation in rodents
    • DOI 10.1118/1.2717384
    • C. T. Badea, L. W. Hedlund, M. D. Lin, J. S. Boslego Mackel, E. Samei, G. Allan, and G. A. Johnson, " Tomographic digital subtraction angiography for lung perfusion estimation in Rodents.," Med. Phys. 34 (5), 1546-1555 (2007). 10.1118/1.2717384 (Pubitemid 46669151)
    • (2007) Medical Physics , vol.34 , Issue.5 , pp. 1546-1555
    • Badea, C.T.1    Hedlund, L.W.2    De Lin, M.3    Boslego MacKel, J.S.4    Samei, E.5    Allan Johnson, G.6
  • 51
    • 58149293707 scopus 로고    scopus 로고
    • Four dimensional intravenous cone-beam computed tomographic subtraction angiography: In vitro study of feasibility
    • 10.1097/RLI.0b013e3181812c4c
    • S. I. Pollmann, C. J. D. Norley, D. M. Pelz, S. P Lownie, and D. W. Holdsworth, " Four dimensional intravenous cone-beam computed tomographic subtraction angiography: In vitro study of feasibility.," Invest. Radiol. 43 (11), 753-761 (2008). 10.1097/RLI.0b013e3181812c4c
    • (2008) Invest. Radiol. , vol.43 , Issue.11 , pp. 753-761
    • Pollmann, S.I.1    Norley, C.J.D.2    Pelz, D.M.3    Lownie, S.P.4    Holdsworth, D.W.5
  • 52
    • 0016034890 scopus 로고
    • The use of a general description of the radiological transmission image for categorizing imaging enhancement procedures
    • C. A. Mistretta, " The use of a general description of the radiological transmission image for categorizing imaging enhancement procedures.," Opt. Eng. 13 (2), 134-137 (1974).
    • (1974) Opt. Eng. , vol.13 , Issue.2 , pp. 134-137
    • Mistretta, C.A.1
  • 53
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • DOI 10.1002/mrm.21391
    • M. Lustig, D. Donoho, and J. M. Pauly, " Sparse MRI: The application of compressed sensing for rapid MR imaging.," Magn. Reson. Med. 58, 1182-1195 (2007). 10.1002/mrm.v58:6 (Pubitemid 350234205)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 55
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
    • K. P. Pruessmann, M. Weiger, M. B. Scheidegger, and P. Boesiger, " SENSE: Sensitivity encoding for fast MRI.," Magn. Reson. Med. 42 (5), 952-962 (1999). 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>.0. CO;2-S (Pubitemid 29521486)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.5 , pp. 952-962
    • Pruessmann, K.P.1    Weiger, M.2    Scheidegger, M.B.3    Boesiger, P.4
  • 57
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • DOI 10.1118/1.2836423
    • G. H. Chen, J. Tang, and S. Leng, " Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.," Med. Phys. 35 (2), 660-663 (2008). 10.1118/1.2836423 (Pubitemid 351190885)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 660-663
    • Chen, G.-H.1    Tang, J.2    Leng, S.3
  • 58
    • 78149484685 scopus 로고    scopus 로고
    • Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): Performance studies
    • 10.1118/1.3460318
    • J. Tang, J. Hsieh, and G. H. Chen, " Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): Performance studies.," Med. Phys. 37 (8), 4377-4388 (2010). 10.1118/1.3460318
    • (2010) Med. Phys. , vol.37 , Issue.8 , pp. 4377-4388
    • Tang, J.1    Hsieh, J.2    Chen, G.H.3
  • 59
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
    • DOI 10.1109/TIT.2005.862083
    • E. J. Candes, J. Romberg, and T. Tao, " Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information.," IEEE Trans. Inf. Theory 52 (2), 489-509 (2006). 10.1109/TIT.2005.862083 (Pubitemid 43174093)
    • (2006) IEEE Transactions on Information Theory , vol.52 , Issue.2 , pp. 489-509
    • Candes, E.J.1    Romberg, J.2    Tao, T.3
  • 60
    • 63449102799 scopus 로고    scopus 로고
    • Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: Potential medical imaging applications in the post-Nyquist era
    • 10.1002/jmri.21683
    • C. A. Mistretta, " Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: Potential medical imaging applications in the post-Nyquist era.," Magn. Reson. Imaging 29 (3), 501-516 (2009). 10.1002/jmri.21683
    • (2009) Magn. Reson. Imaging , vol.29 , Issue.3 , pp. 501-516
    • Mistretta, C.A.1
  • 61
    • 67650081533 scopus 로고    scopus 로고
    • Ultrashort TE spectroscopic imaging (UTESI) using complex highly-constrained backprojection with local reconstruction (HYPR LR)
    • 10.1002/mrm.21986
    • K. Wang, J. Du, R. O'Halloran, S. Fain, S. Kecskemeti, O. Wieben, K. M. Johnson, and C. Mistretta, " Ultrashort TE spectroscopic imaging (UTESI) using complex highly-constrained backprojection with local reconstruction (HYPR LR).," Magn. Reson. Med. 62 (1), 127-134 (2009). 10.1002/mrm.21986
    • (2009) Magn. Reson. Med. , vol.62 , Issue.1 , pp. 127-134
    • Wang, K.1    Du, J.2    O'Halloran, R.3    Fain, S.4    Kecskemeti, S.5    Wieben, O.6    Johnson, K.M.7    Mistretta, C.8
  • 63
    • 73149107247 scopus 로고    scopus 로고
    • Three dimensional imaging of ventilation dynamics in asthmatics using multi-echo projection acquisition with constrained reconstruction
    • 10.1002/mrm.22150
    • J. H. Holmes, R. L. O'Halloran, E. K. Brodsky, T. A. Bley, C. J. Francois, J. V. Velikina, R. L. Sorkness, W. W. Busse, and S. B. Fain, " Three dimensional imaging of ventilation dynamics in asthmatics using multi-echo projection acquisition with constrained reconstruction.," Magn. Reson. Med. 62 (6), 1543-1556 (2009). 10.1002/mrm.22150
    • (2009) Magn. Reson. Med. , vol.62 , Issue.6 , pp. 1543-1556
    • Holmes, J.H.1    O'Halloran, R.L.2    Brodsky, E.K.3    Bley, T.A.4    Francois, C.J.5    Velikina, J.V.6    Sorkness, R.L.7    Busse, W.W.8    Fain, S.B.9
  • 64
    • 77954979982 scopus 로고    scopus 로고
    • Dynamic PET denoising with HYPR processing
    • 10.2967/jnumed.109.073999
    • B. T. Christian, N. T. Vandehey, J. M. Floberg, and C. A. Mistretta, " Dynamic PET denoising with HYPR processing.," J. Nucl. Med. 51, 1147-1154 (2010). 10.2967/jnumed.109.073999
    • (2010) J. Nucl. Med. , vol.51 , pp. 1147-1154
    • Christian, B.T.1    Vandehey, N.T.2    Floberg, J.M.3    Mistretta, C.A.4
  • 67
    • 85027223033 scopus 로고    scopus 로고
    • Improving SNR in dynamic PET imaging of copper-64 and iodine-124 using HYPR
    • Toronto, Canada
    • J. M. Floberg, " Improving SNR in dynamic PET imaging of copper-64 and iodine-124 using HYPR.," Proceedings of the 2009 ISNM Meeting. Toronto, Canada
    • Proceedings of the 2009 ISNM Meeting.
    • Floberg, J.M.1
  • 69
    • 79958824592 scopus 로고    scopus 로고
    • Accurate, in vivo determination of renal perfusion and hemodynamics using HYPR noise reduction and a ten-fold decrease in radiation dose
    • X. Liu, A. N. Primak, J. D. Krier, L. Yu, L. O. Lerman, and C. H. McCollough, " Accurate, in vivo determination of renal perfusion and hemodynamics using HYPR noise reduction and a ten-fold decrease in radiation dose.," Abstract, RSNA (2008).
    • (2008) Abstract, RSNA
    • Liu, X.1    Primak, A.N.2    Krier, J.D.3    Yu, L.4    Lerman, L.O.5    McCollough, C.H.6
  • 70
    • 79958850536 scopus 로고    scopus 로고
    • In vivo determination of renal perfusion and hemodynamics using HYPR noise reduction and a ten-fold decrease in radiation dose
    • Accurate
    • D. Ertel, R. Brauweiler, M. A. Speidel, C. A. Mistretta, and W. A. Kalender, Accurate, " In vivo determination of renal perfusion and hemodynamics using HYPR noise reduction and a ten-fold decrease in radiation dose.," Abstract, RSNA (2008).
    • (2008) Abstract, RSNA
    • Ertel, D.1    Brauweiler, R.2    Speidel, M.A.3    Mistretta, C.A.4    Kalender, W.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.