메뉴 건너뛰기




Volumn 59, Issue 1, 2008, Pages 132-139

Iterative projection reconstruction of time-resolved images using highly-constrained back-projection (HYPR)

Author keywords

HYPR; Iterative reconstruction; MRI; Projection imaging; Time resolved imaging

Indexed keywords

ANGIOGRAPHY; ITERATIVE METHODS; KINETICS; MAGNETIC RESONANCE IMAGING;

EID: 37549035028     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21439     Document Type: Article
Times cited : (49)

References (11)
  • 3
    • 34547941998 scopus 로고    scopus 로고
    • Time-resolved MR angiography with limited projections
    • Huang Y, Wright GA. Time-resolved MR angiography with limited projections. Magn Reson Med 2007;58:316-325.
    • (2007) Magn Reson Med , vol.58 , pp. 316-325
    • Huang, Y.1    Wright, G.A.2
  • 6
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994;13:601-609.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 7
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982;MI-1:113-122.
    • (1982) IEEE Trans Med Imaging , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 8
    • 0345103297 scopus 로고    scopus 로고
    • Ordered subsets algorithms for transmission tomography
    • Erdoǧan H, Fessler JA. Ordered subsets algorithms for transmission tomography. Phys Med Biol 1999;44:2835-2851.
    • (1999) Phys Med Biol , vol.44 , pp. 2835-2851
    • Erdoǧan, H.1    Fessler, J.A.2
  • 9
    • 0009863685 scopus 로고    scopus 로고
    • Control of angular undersampling artifact in projection-based MR angiography by iterative reconstruction
    • Denver, CO, USA, Abstract 1827
    • Holden JE, Unal O, Peters DC, Oakes TR. Control of angular undersampling artifact in projection-based MR angiography by iterative reconstruction. In: Proceedings of the 8th Annual Meeting of the ISMRM, Denver, CO, USA, 2000 (Abstract 1827).
    • (2000) Proceedings of the 8th Annual Meeting of the ISMRM
    • Holden, J.E.1    Unal, O.2    Peters, D.C.3    Oakes, T.R.4
  • 10
    • 0037587219 scopus 로고    scopus 로고
    • Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix
    • Wu O, Østergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med 2003;50:164-174.
    • (2003) Magn Reson Med , vol.50 , pp. 164-174
    • Wu, O.1    Østergaard, L.2    Weisskoff, R.M.3    Benner, T.4    Rosen, B.R.5    Sorensen, A.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.