메뉴 건너뛰기




Volumn 29, Issue 3, 2009, Pages 501-516

Undersampled radial MR acquisition and highly constrained back projection (HYPR) reconstruction: Potential medical imaging applications in the post-nyquist Era

Author keywords

Acceleration; HYPR; SNR enhancement; Undersampling; VIPR

Indexed keywords

ACCELERATION; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIFFUSION TENSOR IMAGING; DIGITAL SUBTRACTION ANGIOGRAPHY; ECHOGRAPHY; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HIGHLY CONSTRAINED BACK PROJECTION; HUMAN; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; MAGNETIC RESONANCE ANGIOGRAPHY; MOTION ANALYSIS SYSTEM; NUCLEAR MAGNETIC RESONANCE IMAGING; PARAMETER; PERFORMANCE MEASUREMENT SYSTEM; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; PROTON NUCLEAR MAGNETIC RESONANCE; RADIATION DOSE DISTRIBUTION; REVIEW; SIGNAL NOISE RATIO; SPECTROSCOPY; VASTLY UNDERSAMPLED IMAGING WITH PROJECTION;

EID: 63449102799     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21683     Document Type: Review
Times cited : (59)

References (71)
  • 2
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • Pipe JG, Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999;42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 3
    • 0036319895 scopus 로고    scopus 로고
    • Time- resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • Barger AV, Block WF, Toropov Y, Grist TM, Mistretta CA. Time- resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 2002;48:297-305.
    • (2002) Magn Reson Med , vol.48 , pp. 297-305
    • Barger, A.V.1    Block, W.F.2    Toropov, Y.3    Grist, T.M.4    Mistretta, C.A.5
  • 6
    • 30344488447 scopus 로고    scopus 로고
    • Highly constrained back- projection for time-resolved MRI
    • Mistretta CA, Wieben O, Velikina J, et al. Highly constrained back- projection for time-resolved MRI. Magn Reson Med 2006;55:30-40.
    • (2006) Magn Reson Med , vol.55 , pp. 30-40
    • Mistretta, C.A.1    Wieben, O.2    Velikina, J.3
  • 7
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
    • Candes EJ, Romberg J, Tao T. Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans Inf Theory 2006;52:489-509.
    • (2006) IEEE Trans Inf Theory , vol.52 , pp. 489-509
    • Candes, E.J.1    Romberg, J.2    Tao, T.3
  • 8
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t sense: Dynamic MRI with high frame rate exploiting spatiotemporal correlation
    • Tsao J, Boesinger P, Pruessman KP. k-t BLAST and k-t sense: dynamic MRI with high frame rate exploiting spatiotemporal correlation. Magn Reson Med 2003;50:1031-1043.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1043
    • Tsao, J.1    Boesinger, P.2    Pruessman, K.P.3
  • 9
    • 0027690283 scopus 로고
    • Applications of reduced-encoding MR imaging with generalized-series reconstruction (RIGR)
    • Webb AG, Liang ZP, Magin RL, Lauterbur PC. Applications of reduced-encoding MR imaging with generalized-series reconstruction (RIGR). J Magn Reson Imaging 1993;3:925-928.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 925-928
    • Webb, A.G.1    Liang, Z.P.2    Magin, R.L.3    Lauterbur, P.C.4
  • 11
    • 0027690283 scopus 로고
    • Applications of reduced-encoding MR imaging with generalized-series reconstruction (RIGR)
    • Webb AG, Liang ZP, Magin RL, Lauterbur PC. Applications of reduced-encoding MR imaging with generalized-series reconstruction (RIGR). J Magn Reson Imaging 1993;3:925-928.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 925-928
    • Webb, A.G.1    Liang, Z.P.2    Magin, R.L.3    Lauterbur, P.C.4
  • 12
    • 36849088522 scopus 로고    scopus 로고
    • the application of compressed sensing for rapid MR imaging
    • Sparse MRI
    • Lustig M, Donoho D, Pauly JM, Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58:1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 13
    • 0042527157 scopus 로고    scopus 로고
    • Fast algorithms for GS-model-based image reconstruction in data-sharing Fourier imaging
    • Liang ZP, Madore B, Glover GH, Pelc NJ. Fast algorithms for GS-model-based image reconstruction in data-sharing Fourier imaging. IEEE Trans Med Imaging 2003;22:1026-1030.
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 1026-1030
    • Liang, Z.P.1    Madore, B.2    Glover, G.H.3    Pelc, N.J.4
  • 15
    • 0033971791 scopus 로고    scopus 로고
    • Undersampled projection reconstruction applied to MR angiography
    • Peters DC, Grist TM, Korosec FR, et al. Undersampled projection reconstruction applied to MR angiography. Magn Reson Med 2000; 43:91-101.
    • (2000) Magn Reson Med , vol.43 , pp. 91-101
    • Peters, D.C.1    Grist, T.M.2    Korosec, F.R.3
  • 16
    • 0033984786 scopus 로고    scopus 로고
    • Under-sampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging
    • Vigen KK, Peters DC, Grist TM, Block WF, Mistretta CA. Under-sampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging. Magn Reson Med 2000;43:170-176.
    • (2000) Magn Reson Med , vol.43 , pp. 170-176
    • Vigen, K.K.1    Peters, D.C.2    Grist, T.M.3    Block, W.F.4    Mistretta, C.A.5
  • 18
    • 0031850913 scopus 로고    scopus 로고
    • Reduced circular field-of-view imaging
    • SchefflerK, Hennig J. Reduced circular field-of-view imaging. Magn Reson Med 1998;40:474-480.
    • (1998) Magn Reson Med , vol.40 , pp. 474-480
    • Scheffler, K.1    Hennig, J.2
  • 19
    • 30344456972 scopus 로고    scopus 로고
    • PC VIPR: A high resolution and high speed phase contrast method using 3D vastly undersampled isotropic projection imaging
    • Gu T, Block WF, Korosec FR, et al. PC VIPR: a high resolution and high speed phase contrast method using 3D vastly undersampled isotropic projection imaging. AJNR Am J Neuroradiol 2005;26:743-749.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 743-749
    • Gu, T.1    Block, W.F.2    Korosec, F.R.3
  • 21
    • 14744296815 scopus 로고    scopus 로고
    • Rapid fat suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction
    • Lu A, Brodsky EK, Grist TM, Block WF. Rapid fat suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction. Magn Reson Med 2005; 53:692-699.
    • (2005) Magn Reson Med , vol.53 , pp. 692-699
    • Lu, A.1    Brodsky, E.K.2    Grist, T.M.3    Block, W.F.4
  • 22
    • 63449126910 scopus 로고    scopus 로고
    • Average and time-resolved dual velocity encoded phase contrast vastly undersampled isotropic projection imaging
    • Seattle, WA, USA, Abstract 2958
    • Johnson KM, Wieben O, Turski P, Mistretta CA. Average and time-resolved dual velocity encoded phase contrast vastly undersampled isotropic projection imaging. In: Proceedings of the 14th Annual Meeting of the ISMRM, Seattle, WA, USA, 2006 (Abstract 2958).
    • (2006) Proceedings of the 14th Annual Meeting of the ISMRM
    • Johnson, K.M.1    Wieben, O.2    Turski, P.3    Mistretta, C.A.4
  • 24
    • 63449096256 scopus 로고    scopus 로고
    • 7D flow and anatomical imaging at 3T with PC VIPR. [Abstract]
    • Basel, Switzerland
    • Johnson K, et al. 7D flow and anatomical imaging at 3T with PC VIPR. [Abstract]. 18th International Workshop on MR Angiography, Basel, Switzerland, 2006.
    • (2006) 18th International Workshop on MR Angiography
    • Johnson, K.1
  • 28
    • 63449108978 scopus 로고    scopus 로고
    • Recent progress of non-contrast-enhanced MRA techniques: Focus on peripheral run-offs and renal arteries. [Abstract]
    • Istanbul, Turkey
    • Miyazaki M, Sugiura S, Kassai Y, et al. Recent progress of non-contrast-enhanced MRA techniques: focus on peripheral run-offs and renal arteries. [Abstract]. 19th Annual International Conference on MR Angiography, Istanbul, Turkey, 2007.
    • (2007) 19th Annual International Conference on MR Angiography
    • Miyazaki, M.1    Sugiura, S.2    Kassai, Y.3
  • 31
    • 0033852691 scopus 로고    scopus 로고
    • Three-dimensional, time-resolved (4D) relative pressure mapping using magnetic resonance imaging
    • Tyszka JM, Laidlaw DH, Asa JW, Silverman JM. Three-dimensional, time-resolved (4D) relative pressure mapping using magnetic resonance imaging. J Magn Reson Imaging 2000;12:321-329.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 321-329
    • Tyszka, J.M.1    Laidlaw, D.H.2    Asa, J.W.3    Silverman, J.M.4
  • 32
    • 36248995983 scopus 로고    scopus 로고
    • Measurement of trans-stenotic pressure gradients in swine: Comparison between retrospective ECG-gated 3D phase-contrast MRA and endovascular pressure-sensing guidewires
    • Lum DP, Johnson KM, Paul RK, et al. Measurement of trans-stenotic pressure gradients in swine: comparison between retrospective ECG-gated 3D phase-contrast MRA and endovascular pressure-sensing guidewires. Radiology 2007;245:751-760.
    • (2007) Radiology , vol.245 , pp. 751-760
    • Lum, D.P.1    Johnson, K.M.2    Paul, R.K.3
  • 33
    • 33846408001 scopus 로고    scopus 로고
    • Physiologic and anatomic assessment of a canine carotid artery stenosis model with phase contrast vastly undersampled isotropic projection imaging (PC-VIPR)
    • Turk AS, Johnson KM, Lum D, et al. Physiologic and anatomic assessment of a canine carotid artery stenosis model with phase contrast vastly undersampled isotropic projection imaging (PC-VIPR). AJNR Am J Neuroradiol 2007;28:111-115.
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 111-115
    • Turk, A.S.1    Johnson, K.M.2    Lum, D.3
  • 34
    • 36248993022 scopus 로고    scopus 로고
    • Is there replacement for percentage stenosis in characterizing occlusive vascular disease?
    • Prince MR. Is there replacement for percentage stenosis in characterizing occlusive vascular disease? Radiology 2007;245:617-618.
    • (2007) Radiology , vol.245 , pp. 617-618
    • Prince, M.R.1
  • 35
    • 0026168752 scopus 로고
    • A generalized series approach to MR spectroscopic imaging
    • Lauterbur PC, Liang ZP. A generalized series approach to MR spectroscopic imaging. IEEE Trans Med Imaging 1991;10:132-137.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 132-137
    • Lauterbur, P.C.1    Liang, Z.P.2
  • 36
    • 34547941998 scopus 로고    scopus 로고
    • Time-resolved 3D MR angiography with limited projections
    • Huang Y, Wright G. Time-resolved 3D MR angiography with limited projections. Magn Reson Med 2007;58:316-325.
    • (2007) Magn Reson Med , vol.58 , pp. 316-325
    • Huang, Y.1    Wright, G.2
  • 40
    • 63449125374 scopus 로고    scopus 로고
    • First pass HYPR Flow: Time-resolved CE-MRA with 322-fold under- sampling and a phase contrast HYPR composite providing 4-fold SNR restoration per time frame. [Abstract]
    • AZ, USA, February
    • Velikina J, Johnson K, Wieben O, Turski P, Grist T, Mistretta CA. First pass HYPR Flow: time-resolved CE-MRA with 322-fold under- sampling and a phase contrast HYPR composite providing 4-fold SNR restoration per time frame. [Abstract]. ISMRM Workshop on Non-Cartesian MRI, Sedona, AZ, USA, February 2007.
    • (2007) ISMRM Workshop on Non-Cartesian MRI, Sedona
    • Velikina, J.1    Johnson, K.2    Wieben, O.3    Turski, P.4    Grist, T.5    Mistretta, C.A.6
  • 42
    • 51449092401 scopus 로고    scopus 로고
    • 3D high temporal and spatial resolution contrast-enhanced MR an-giography of the whole brain
    • Haider CR, Hu HH, Campeau NG, Huston III J, Riederer SJ. 3D high temporal and spatial resolution contrast-enhanced MR an-giography of the whole brain. Magn Reson Med 2008;60:749-760.
    • (2008) Magn Reson Med , vol.60 , pp. 749-760
    • Haider, C.R.1    Hu, H.H.2    Campeau, N.G.3    Huston III, J.4    Riederer, S.J.5
  • 45
    • 85092120357 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography using time resolved interleaved projection sampling with 3D Cartesian phase and slice encoding (TRIPPS)
    • in press
    • Du J. Contrast-enhanced MR angiography using time resolved interleaved projection sampling with 3D Cartesian phase and slice encoding (TRIPPS). Magn Reson Med (in press).
    • Magn Reson Med
    • Du, J.1
  • 46
    • 0027633059 scopus 로고
    • Keyhole method for accelerating imaging of contrast agent uptake
    • van Vaals J, Brummer ME, Dixon WT, et al. Keyhole method for accelerating imaging of contrast agent uptake. J Magn Reson Imaging 1993;3:671-675.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 671-675
    • van Vaals, J.1    Brummer, M.E.2    Dixon, W.T.3
  • 48
  • 49
    • 63449110294 scopus 로고    scopus 로고
    • Constrained reconstruction for enhanced SNR in dynamic medical imaging: Imaging in the post-Nyquist/post-Car-tesian era
    • San Diego, CA, USA, February
    • Mistretta CA. Constrained reconstruction for enhanced SNR in dynamic medical imaging: imaging in the post-Nyquist/post-Car-tesian era. In: Proceedings of the SPIE, San Diego, CA, USA, February, 2008.
    • (2008) Proceedings of the SPIE
    • Mistretta, C.A.1
  • 51
    • 63449092816 scopus 로고    scopus 로고
    • HYPR-spectral photoacoustic computed tomography. NIH SBIR grant 1-R43-RR025871-01
    • June
    • Kruger RA. HYPR-spectral photoacoustic computed tomography. NIH SBIR grant 1-R43-RR025871-01, June, 2008.
    • (2008)
    • Kruger, R.A.1
  • 53
    • 0021669012 scopus 로고
    • Spatial mapping of chemical shift in NMR
    • Mansfield P. Spatial mapping of chemical shift in NMR. Magn Reson Med 1984;1:370-386.
    • (1984) Magn Reson Med , vol.1 , pp. 370-386
    • Mansfield, P.1
  • 55
    • 63449135307 scopus 로고    scopus 로고
    • MR spectroscopic imaging of short T2 tissue using complex division (CD) HYPR-LR reconstruction
    • Toronto, Ontario, Canada, Poster 3148
    • Wang K, O'Halloran R, Fain S, et al. MR spectroscopic imaging of short T2 tissue using complex division (CD) HYPR-LR reconstruction. In: Proceedings of the 16th Annual Meeting of ISMRM, Toronto, Ontario, Canada, 2008 (Poster 3148).
    • (2008) Proceedings of the 16th Annual Meeting of ISMRM
    • Wang, K.1    O'Halloran, R.2    Fain, S.3
  • 56
    • 37549035028 scopus 로고    scopus 로고
    • Iterative reconstruction of time-resolved images using highly constrained back-projection (HYPR)
    • O'Halloran RL, Wen Z, Holmes JH, Fain SB. Iterative reconstruction of time-resolved images using highly constrained back-projection (HYPR). Magn Reson Med 2008;59:132-139.
    • (2008) Magn Reson Med , vol.59 , pp. 132-139
    • O'Halloran, R.L.1    Wen, Z.2    Holmes, J.H.3    Fain, S.B.4
  • 58
    • 37549061019 scopus 로고    scopus 로고
    • More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization. [Abstract]
    • Basel, Switzerland
    • Griswold M, et al. More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization. [Abstract]. 18th International Workshop on MR Angiography, Basel, Switzerland, 2006.
    • (2006) 18th International Workshop on MR Angiography
    • Griswold, M.1
  • 59
    • 63449105551 scopus 로고    scopus 로고
    • Iterative highly constrained back projection (HYPR) reconstruction of undersampled diffusion weighted data in hyperpolarized helium-3 MRI
    • Berlin, Germany, Abstract 459
    • O'Halloran RL, Holmes J, Peterson E, Fain S. Iterative highly constrained back projection (HYPR) reconstruction of undersampled diffusion weighted data in hyperpolarized helium-3 MRI. In: Proceedings of the 15th Annual Meeting of ISMRM, Berlin, Germany,2007 (Abstract 459).
    • (2007) Proceedings of the 15th Annual Meeting of ISMRM
    • O'Halloran, R.L.1    Holmes, J.2    Peterson, E.3    Fain, S.4
  • 60
    • 63449091566 scopus 로고    scopus 로고
    • Myocardial perfusion MRI with sliding window and CG-HYPR
    • Toronto, Ontario, Canada, Abstract 433
    • Ge L, Kino A, Berg N, et al. Myocardial perfusion MRI with sliding window and CG-HYPR. In: Proceedings of the 16th Annual Meeting of ISMRM, Toronto, Ontario, Canada, 2008 (Abstract 433).
    • (2008) Proceedings of the 16th Annual Meeting of ISMRM
    • Ge, L.1    Kino, A.2    Berg, N.3
  • 61
    • 63449089998 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced coronary MRA with HYPR PR: A feasibility study
    • Toronto, Ontario, Canada, Abstract 937
    • Ge L, Bi X, Lai P, Peng H, Larson A, Li, D, Time-resolved contrast-enhanced coronary MRA with HYPR PR: a feasibility study. In: Proceedings of the 16th Annual Meeting of ISMRM, Toronto, Ontario, Canada, 2008 (Abstract 937).
    • (2008) Proceedings of the 16th Annual Meeting of ISMRM
    • Ge, L.1    Bi, X.2    Lai, P.3    Peng, H.4    Larson, A.5    Li, D.6
  • 63
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • Chen G-H, Tang J, Leng S. Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys 2008;35:660-663.
    • (2008) Med Phys , vol.35 , pp. 660-663
    • Chen, G.-H.1    Tang, J.2    Leng, S.3
  • 64
    • 63449121023 scopus 로고    scopus 로고
    • Prediction of HYPR and HYPR LR performance based on image sparsity and temporal correlation
    • Toronto, Ontario, Canada, Poster 3150
    • Velikina JV, Wu Y, Mistretta CA. Prediction of HYPR and HYPR LR performance based on image sparsity and temporal correlation. In: Proceedings of the 16th Annual Meeting of ISMRM, Toronto, Ontario, Canada, 2008 (Poster 3150).
    • (2008) Proceedings of the 16th Annual Meeting of ISMRM
    • Velikina, J.V.1    Wu, Y.2    Mistretta, C.A.3
  • 65
    • 35148843406 scopus 로고    scopus 로고
    • ECG-gated HYPR reconstruction for undersampled CT myocardial perfusion imaging
    • San Diego, CA, USA, February
    • Speidel MA, Van Lysel MS, Reeder SB, et al. ECG-gated HYPR reconstruction for undersampled CT myocardial perfusion imaging. In: Proceedings of the SPIE, Medical Imaging, San Diego, CA, USA, February 2007.
    • (2007) Proceedings of the SPIE, Medical Imaging
    • Speidel, M.A.1    Van Lysel, M.S.2    Reeder, S.B.3
  • 66
    • 63449109583 scopus 로고    scopus 로고
    • Supanich MP, Rowley HA, Turk AS, et al. Low radiation dose neu-rovascular HYPR CT: combined CTperfusion and time-resolved CT angiography from a single dynamic injection. [Abstract]. RSNA, 2007.
    • Supanich MP, Rowley HA, Turk AS, et al. Low radiation dose neu-rovascular HYPR CT: combined CTperfusion and time-resolved CT angiography from a single dynamic injection. [Abstract]. RSNA, 2007.
  • 67
    • 63449136382 scopus 로고    scopus 로고
    • Liu X, Primak AN, Krier JD, Yu L, Lerman LO, McCollough CH. Accurate, in vivo determination of renal perfusion and hemody- namics using HYPR noise reduction and a ten-fold decrease in radiation dose. [Abstract]. RSNA, 2008.
    • Liu X, Primak AN, Krier JD, Yu L, Lerman LO, McCollough CH. Accurate, in vivo determination of renal perfusion and hemody- namics using HYPR noise reduction and a ten-fold decrease in radiation dose. [Abstract]. RSNA, 2008.
  • 68
    • 63449136834 scopus 로고    scopus 로고
    • Ertel D, Brauweiler R, Speidel MA, Mistretta CA, Kalender WA. Accurate, in vivo determination of renal perfusion and hemody-namics using HYPR noise reduction and a ten-fold decrease in radiation dose. [Abstract]. RSNA, 2008.
    • Ertel D, Brauweiler R, Speidel MA, Mistretta CA, Kalender WA. Accurate, in vivo determination of renal perfusion and hemody-namics using HYPR noise reduction and a ten-fold decrease in radiation dose. [Abstract]. RSNA, 2008.
  • 69
    • 0026923442 scopus 로고
    • Statistic-based map image-reconstruction from Poisson data using Gibbs priors
    • Hebert TJ, Leahy R. Statistic-based map image-reconstruction from Poisson data using Gibbs priors. IEEE Trans Signal Process 1992;40:2290-2303.
    • (1992) IEEE Trans Signal Process , vol.40 , pp. 2290-2303
    • Hebert, T.J.1    Leahy, R.2
  • 70
    • 63449119539 scopus 로고    scopus 로고
    • Vandehey NT, Mistretta CA, Christian BT. Application of HYPR processing to dynamic PETstudies. [Abstract]. SNM, New Orleans, LA, USA, 2008.
    • Vandehey NT, Mistretta CA, Christian BT. Application of HYPR processing to dynamic PETstudies. [Abstract]. SNM, New Orleans, LA, USA, 2008.
  • 71
    • 33645712892 scopus 로고    scopus 로고
    • Compressed sensing
    • Donoho D. Compressed sensing. IEEE Trans Inf Theory 2006;52: 1289-1306.
    • (2006) IEEE Trans Inf Theory , vol.52 , pp. 1289-1306
    • Donoho, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.