메뉴 건너뛰기




Volumn 2, Issue 9, 2010, Pages 1627-1640

Bioanalytical solutions to acetonitrile shortages

Author keywords

[No Author keywords available]

Indexed keywords

ACETONITRILE; AMMONIUM ACETATE; AMMONIUM SULFATE; FORMIC ACID; METAL ION; METHANOL; PHOSPHOLIPID; TRICHLOROACETIC ACID; ACETONITRILE DERIVATIVE; SOLVENT;

EID: 79952516009     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.10.76     Document Type: Review
Times cited : (15)

References (61)
  • 1
    • 68949206401 scopus 로고    scopus 로고
    • Performance to burn? Re?evaluating the choice of acetonitrile as the platform solvent for analytical HPLC
    • Welch CJ, Brkovic T, Schafer W, Gong X. Performance to burn? Re?evaluating the choice of acetonitrile as the platform solvent for analytical HPLC. Green Chem. 11(8), 1232-1238 (2009).
    • (2009) Green Chem. , vol.11 , Issue.8 , pp. 1232-1238
    • Welch, C.J.1    Brkovic, T.2    Schafer, W.3    Gong, X.4
  • 2
    • 79951769600 scopus 로고    scopus 로고
    • White paper on recent issues in regulated bioanalysis from the 3rd Calibration and Validation Group Workshop
    • Savoie N, Garofolo F, van Amsterdam P et al. 2009 white paper on recent issues in regulated bioanalysis from The 3rd Calibration and Validation Group Workshop. Bioanalysis 2(1), 53-68 (2010).
    • (2009) Bioanalysis , vol.2 , Issue.1 , pp. 53-68
    • Savoie, N.1    Garofolo, F.2    Van Amsterdam, P.3
  • 3
    • 34249938957 scopus 로고    scopus 로고
    • Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS
    • DOI 10.1016/j.jpba.2007.02.006, PII S0731708507001239, Hyphenated Techniques in Pharmaceutical and Biomedical Analysis 2006
    • Xu RN, Fan L, Rieser MJ, El-Shourbagy TA. Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS. J. Pharm. Biomed. Anal. 44(2), 342-355 (2007). (Pubitemid 46880094)
    • (2007) Journal of Pharmaceutical and Biomedical Analysis , vol.44 , Issue.2 , pp. 342-355
    • Xu, R.N.1    Fan, L.2    Rieser, M.J.3    El-Shourbagy, T.A.4
  • 4
    • 0037420211 scopus 로고    scopus 로고
    • Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography-tandem mass spectrometry
    • DOI 10.1016/S1570-0232(02)00914-5, PII S1570023202009145
    • Polson C, Sarkar P, Incledon B, Raguvaran V, Grant R. Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography-tandem mass spectrometry. J. Chromatogr. B Analyt. Technol. Biomed. Life. Sci. 785(2), 263-275 (2003). (Pubitemid 36126166)
    • (2003) Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences , vol.785 , Issue.2 , pp. 263-275
    • Polson, C.1    Sarkar, P.2    Incledon, B.3    Raguvaran, V.4    Grant, R.5
  • 5
    • 84889476490 scopus 로고    scopus 로고
    • Reversed-phase HPLC
    • Kazakevich Y, Lobrutto R (Eds) John Wiley & Sons, Hoboken, NJ, USA
    • Kazakevich Y, LoBrutto R. Reversed-phase HPLC. In: HPLC for Pharmaceutical Scientists. Kazakevich Y, Lobrutto R (Eds). John Wiley & Sons, Hoboken, NJ, USA 139-239 (2007).
    • (2007) HPLC for Pharmaceutical Scientists , pp. 139-239
    • Kazakevich, Y.1    Lobrutto, R.2
  • 6
    • 79953245785 scopus 로고    scopus 로고
    • HPLC method development for drug discovery LC-MS assays in rapid pharmacokinetics applications
    • Ahujia S, Rasmussen H (Eds). Elsevier
    • Xu X. HPLC method development for drug discovery LC-MS assays in rapid pharmacokinetics applications. In: HPLC Method Development for Pharmaceuticals. Ahujia S, Rasmussen H (Eds). Elsevier, 317-351 (2007).
    • (2007) HPLC Method Development for Pharmaceuticals , pp. 317-351
    • Xu, X.1
  • 8
    • 85056517731 scopus 로고    scopus 로고
    • Bioanalytical assays in a drug discovery environment
    • Korfmacher W (Eds). CRC Press, Boca Raton, FL, USA
    • Korfmacher WA. Bioanalytical assays in a drug discovery environment. In: Using Mass Spectrometry for Drug Metabolism Studies, Korfmacher W (Eds). CRC Press, Boca Raton, FL, USA 1-26 (2005).
    • (2005) Using Mass Spectrometry for Drug Metabolism Studies , pp. 1-26
    • Korfmacher, W.A.1
  • 9
    • 25844504983 scopus 로고    scopus 로고
    • Critical review of development, validation, and transfer for high throughput bioanalytical LC-MS/MS methods
    • Zhou S, Song Q, Tang Y, Naidong W. Critical review of development, validation, and transfer for high throughput bioanalytical LC-MS/MS methods. Curr. Pharm. Anal. 1(1), 3-14 (2005).
    • (2005) Curr. Pharm. Anal. , vol.1 , Issue.1 , pp. 3-14
    • Zhou, S.1    Song, Q.2    Tang, Y.3    Naidong, W.4
  • 10
    • 0035147085 scopus 로고    scopus 로고
    • Methanol solvent may cause increased apparent metabolic instability in in vitro assays
    • Yin H, Tran P, Greenberg GE, Fischer V. Methanol solvent may cause increased apparent metabolic instability in in vitro assays. Drug Metab. Dispos. 29(2), 185-193 (2001). (Pubitemid 32112934)
    • (2001) Drug Metabolism and Disposition , vol.29 , Issue.2 , pp. 185-193
    • Yin, H.1    Tran, P.2    Greenberg, G.E.3    Fischer, V.4
  • 11
    • 33750297774 scopus 로고    scopus 로고
    • Viscosity measurements of methanol-water and acetonitrile-water mixtures at pressures up to 3500 bar using a novel capillary time-of-flight viscometer
    • DOI 10.1016/j.chroma.2006.09.006, PII S0021967306017213
    • Thompson JW, Kaiser TJ, Jorgenson JW. Viscosity measurements of methanol-water and acetonitrile-water mixtures at pressures up to 3500 bar using a novel capillary time-of-fight viscometer. J. Chromatogr. A 1134(1-2), 201-209 (2006). (Pubitemid 44633949)
    • (2006) Journal of Chromatography A , vol.1134 , Issue.1-2 , pp. 201-209
    • Thompson, J.W.1    Kaiser, T.J.2    Jorgenson, J.W.3
  • 12
    • 54049120090 scopus 로고    scopus 로고
    • Isopropanol protein precipitation for the analysis of plasma free metanephrines by liquid chromatography-tandem mass spectrometry
    • Marney LC, Laha TJ, Baird GS, Rainey PM, Hoofnagle AN. Isopropanol protein precipitation for the analysis of plasma free metanephrines by liquid chromatography-tandem mass spectrometry. Clin. Chem. 54(10), 1729-1732 (2008).
    • (2008) Clin. Chem. , vol.54 , Issue.10 , pp. 1729-1732
    • Marney, L.C.1    Laha, T.J.2    Baird, G.S.3    Rainey, P.M.4    Hoofnagle, A.N.5
  • 13
    • 54349129338 scopus 로고    scopus 로고
    • Analyte recovery from deproteinized serum for HPLC
    • Shihabi ZK. Analyte recovery from deproteinized serum for HPLC. J. Liq. Chromatogr. Relat. Technol. 31, 3159-3168 (2008).
    • (2008) J. Liq. Chromatogr. Relat. Technol. , vol.31 , pp. 3159-3168
    • Shihabi, Z.K.1
  • 14
    • 79953246900 scopus 로고    scopus 로고
    • Solutions of dealing with global acetonitrile shortage in discovery HTP bioanalytical laboratory
    • Washington DC, USA 16-20 August
    • Gao H, Williams J, Huang H et al. Solutions of dealing with global acetonitrile shortage in discovery HTP bioanalytical laboratory Presented at: 238th ACS National Meeting Washington, DC, USA 16-20 August 2009.
    • (2009) Presented At: 238th ACS National Meeting
    • Gao, H.1    Williams, J.2    Huang, H.3
  • 16
    • 78650649024 scopus 로고    scopus 로고
    • Evaluation of protein precipitation flter plates for high?throughput LC-MS/MS bioanalytical sample preparation
    • Kocan G, Quang C, Tang D: Evaluation of protein precipitation flter plates for high?throughput LC-MS/MS bioanalytical sample preparation. American Drug Discovery 1(3), 21-24 (2006).
    • (2006) American Drug Discovery , vol.1 , Issue.3 , pp. 21-24
    • Kocan, G.1    Quang, C.2    Tang, D.3
  • 17
    • 33645224920 scopus 로고    scopus 로고
    • Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma
    • Little JL, Wempe MF, Buchanan CM. Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: examining lipid matrix ionization effects in plasma. J. Chromatogr. B Analyt. Technol. Biomed. Life. Sci. 833(2), 219-230 (2006).
    • (2006) J. Chromatogr. B Analyt. Technol. Biomed. Life. Sci. , vol.833 , Issue.2 , pp. 219-230
    • Little, J.L.1    Wempe, M.F.2    Buchanan, C.M.3
  • 18
    • 62249191310 scopus 로고    scopus 로고
    • Water-immiscible solvents as diluents in reversed-phase liquid chromatography
    • Loeser E, Babiak S, Drumm P. Water-immiscible solvents as diluents in reversed-phase liquid chromatography. J. Chromatogr. A 1216(15), 3409-3412 (2009).
    • (2009) J. Chromatogr. A , vol.1216 , Issue.15 , pp. 3409-3412
    • Loeser, E.1    Babiak, S.2    Drumm, P.3
  • 19
    • 33846312100 scopus 로고    scopus 로고
    • Evaluation of 384-well formatted sample preparation technologies for regulated bioanalysis
    • DOI 10.1002/rcm.2808
    • Chang MS, Kim EJ, El-Shourbagy TA. Evaluation of 384?well formatted sample preparation technologies for regulated bioanalysis. Rapid Commun. Mass Spectrom. 21(1), 64-72 (2007). (Pubitemid 46113094)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.1 , pp. 64-72
    • Chang, M.S.1    Kim, E.J.2    El-Shourbagy, T.A.3
  • 20
    • 9644272516 scopus 로고    scopus 로고
    • Direct injection of 96-well organic extracts onto a hydrophilic interaction chromatography/tandem mass spectrometry system using a silica stationary phase and an aqueous/organic mobile phase [2]
    • DOI 10.1002/rcm.1695
    • Naidong W, Zhou W, Song Q, Zhou S. Direct injection of 96?well organic extracts onto a hydrophilic interaction chromatography/tandem mass spectrometry system using a silica stationary phase and an aqueous/organic mobile phase. Rapid Commun. Mass Spectrom. 18(23), 2963-2968 (2004). (Pubitemid 39576842)
    • (2004) Rapid Communications in Mass Spectrometry , vol.18 , Issue.23 , pp. 2963-2968
    • Naidong, W.1    Zhou, W.2    Song, Q.3    Zhou, S.4
  • 21
    • 79953233783 scopus 로고    scopus 로고
    • Oasis HLB SPE disk for rapid multiresidue determination of pharmaceuticals in drinking water
    • Young MS. Oasis HLB SPE disk for rapid multiresidue determination of pharmaceuticals in drinking water. LCGC North Am. (Suppl.), 29 (2009).
    • (2009) LCGC North Am. (Suppl.) , vol.29
    • Young, M.S.1
  • 22
    • 20444481663 scopus 로고    scopus 로고
    • Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma
    • DOI 10.1016/j.chroma.2005.04.056, PII S0021967305007776
    • Alnouti Y, Srinivasan K, Waddell D, Bi H, Kavetskaia O, Gusev AI. Development and application of a new on?line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma. J. Chromatogr. A 1080(2), 99-106 (2005). (Pubitemid 40813171)
    • (2005) Journal of Chromatography A , vol.1080 , Issue.2 , pp. 99-106
    • Alnouti, Y.1    Srinivasan, K.2    Waddell, D.3    Bi, H.4    Kavetskaia, O.5    Gusev, A.I.6
  • 23
    • 70350126251 scopus 로고    scopus 로고
    • Restricted access media supports for direct high?throughput analysis of biological fuid samples: Review of recent applications
    • Cassiano NM, Barreiro JC, Moraes MC, Oliveira RV, Cass QB. Restricted access media supports for direct high?throughput analysis of biological fuid samples: review of recent applications. Bioanalysis 1(3), 577-594 (2009).
    • (2009) Bioanalysis , vol.1 , Issue.3 , pp. 577-594
    • Cassiano, N.M.1    Barreiro, J.C.2    Moraes, M.C.3    Oliveira, R.V.4    Cass, Q.B.5
  • 24
    • 79953249201 scopus 로고    scopus 로고
    • Quantitation of fentanyl and norfentanyl from urine using an on?line high throughput system
    • Espourteille FA. Quantitation of fentanyl and norfentanyl from urine using an on?line high throughput system. LC-GC Eur. 26, 9 (2008).
    • (2008) LC-GC Eur. , vol.26 , pp. 9
    • Espourteille, F.A.1
  • 26
    • 79953245889 scopus 로고    scopus 로고
    • Practical solutions for overcoming the acetonitrile shortage in analytical procedures
    • Dresden Germany 28 June-2 July 2009
    • Guillarme D, Schappler J, Henchoz Y, Rudaz S, Veuthey J?L. Practical solutions for overcoming the acetonitrile shortage in analytical procedures. Presented at: HPLC 2009. Dresden, Germany 28 June-2 July 2009.
    • Presented At: HPLC 2009
    • Guillarme, D.1    Schappler, J.2    Henchoz, Y.3    Rudaz, S.4    Veuthey, J.-L.5
  • 27
    • 34848845269 scopus 로고    scopus 로고
    • Methanol-associated matrix effects in electrospray ionization tandem mass spectrometry
    • DOI 10.1373/clinchem.2007.090811
    • Annesley TM. Methanol-associated matrix effects in electrospray ionization tandem mass spectrometry Clin. Chem. 53(10), 1827-1834 (2007). (Pubitemid 47509677)
    • (2007) Clinical Chemistry , vol.53 , Issue.10 , pp. 1827-1834
    • Annesley, T.M.1
  • 28
    • 33748608548 scopus 로고    scopus 로고
    • Selectivity in reversed-phase separations. Influence of the stationary phase
    • DOI 10.1016/j.chroma.2006.06.006, PII S0021967306011368
    • Neue UD, O'Gara JE, Mendez A. Selectivity in reversed?phase separations. Infuence of the stationary phase. J. Chromatogr. A 1127(1-2), 161-174 (2006). (Pubitemid 44376370)
    • (2006) Journal of Chromatography A , vol.1127 , Issue.1-2 , pp. 161-174
    • Neue, U.D.1    O'Gara, J.E.2    Mendez, A.3
  • 29
    • 34248398078 scopus 로고    scopus 로고
    • Improvements to the Sample Manipulation Design of a LEAP CTC HTS PAL Autosampler Used for High-Throughput Qualitative and Quantitative Liquid Chromatography-Mass Spectrometry Assays
    • DOI 10.1016/j.jala.2007.01.002, PII S1535553507000391
    • Drexler DM, Edinger KJ, Mongillo JJ. Improvements to the sample manipulation design of a LEAP CTC HTS PAL autosampler used for high?throughput qualitative and quantitative liquid chromatography-mass spectrometry assays. JALA 12(3), 152-156 (2007). (Pubitemid 46731209)
    • (2007) JALA - Journal of the Association for Laboratory Automation , vol.12 , Issue.3 , pp. 152-156
    • Drexler, D.M.1    Edinger, K.J.2    Mongillo, J.J.3
  • 30
    • 85010246622 scopus 로고
    • Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromato?
    • van Deemter JJ, Zuiderweg FJ, Klinkenberg A. Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromato? graphy Chem. Eng Sci. 5, 271-289 (1956).
    • (1956) Graphy Chem Eng Sci. , vol.5 , pp. 271-289
    • Van Deemter, J.J.1    Zuiderweg, F.J.2    Klinkenberg, A.3
  • 31
    • 70449641110 scopus 로고    scopus 로고
    • A review of current trends and advances in modern bio?analytical methods: Chromatography and sample preparation
    • Novakova L, Vlckova H. A review of current trends and advances in modern bio?analytical methods: chromatography and sample preparation. Anal. Chim. Acta 656(1-2), 8-35 (2009).
    • (2009) Anal. Chim. Acta , vol.656 , Issue.1-2 , pp. 8-35
    • Novakova, L.1    Vlckova, H.2
  • 32
    • 56549122608 scopus 로고    scopus 로고
    • Fused-core particles: A practical alternative to sub?2 micron particles
    • Salisbury JJ. Fused-core particles: a practical alternative to sub?2 micron particles. J. Chromatogr. Sci. 46(10), 883-886 (2008).
    • (2008) J. Chromatogr. Sci. , vol.46 , Issue.10 , pp. 883-886
    • Salisbury, J.J.1
  • 33
    • 70349319343 scopus 로고    scopus 로고
    • Practical comparison of 2.7 microm Fused-core silica particles and porous sub?2 microm particles for fast separations in pharmaceutical process development
    • Abrahim A, Al-Sayah M, Skrdla P, Bereznitski Y, Chen Y, Wu N. Practical comparison of 2.7 microm Fused-core silica particles and porous sub?2 microm particles for fast separations in pharmaceutical process development. J. Pharm. Biomed. Anal. 51(1), 131-137 (2010).
    • (2010) J. Pharm. Biomed. Anal. , vol.51 , Issue.1 , pp. 131-137
    • Abrahim, A.1    Al-Sayah, M.2    Skrdla, P.3    Bereznitski, Y.4    Chen, Y.5    Wu, N.6
  • 34
    • 65649138794 scopus 로고    scopus 로고
    • A high-throughput LC-MS/MS method for the quantitation of posaconazole in human plasma: Implementing fused core silica liquid chromatography
    • Cunliffe JM, Noren CF, Hayes RN, Clement RP, Shen JX. A high-throughput LC-MS/MS method for the quantitation of posaconazole in human plasma: implementing fused core silica liquid chromatography J. Pharm. Biomed. Anal. 50(1), 46-52 (2009).
    • (2009) J. Pharm. Biomed. Anal. , vol.50 , Issue.1 , pp. 46-52
    • Cunliffe, J.M.1    Noren, C.F.2    Hayes, R.N.3    Clement, R.P.4    Shen, J.X.5
  • 35
    • 0020116105 scopus 로고
    • Supercritical fuid chromatography with small particle diameter packed columns
    • Gere DR, Board R, McManigill D. Supercritical fuid chromatography with small particle diameter packed columns. Anal. Chem. 54(4), 736-740 (1982). (Pubitemid 12509287)
    • (1982) Analytical Chemistry , vol.54 , Issue.4 , pp. 736-740
    • Gere Dennis, R.1    Board Robert2    McManigill Douglass3
  • 36
    • 33947479623 scopus 로고
    • Porphyrin studies. XX. High pressure gas chromatography above critical temperatures
    • Klesper E, Corwin AH, Turner DA. Porphyrin studies. XX. High pressure gas chromatography above critical temperatures. J. Org Chem. 27, 700-701 (1962).
    • (1962) J. Org Chem. , vol.27 , pp. 700-701
    • Klesper, E.1    Corwin, A.H.2    Turner, D.A.3
  • 37
    • 43049091140 scopus 로고    scopus 로고
    • A unifed classifcation of stationary phases for packed column supercritical fuid chromatography
    • West C, Lesellier E. A unifed classifcation of stationary phases for packed column supercritical fuid chromatography J. Chromatogr. A 1191(1-2), 21-39 (2008).
    • (2008) J Chromatogr. A , vol.1191 , Issue.1-2 , pp. 21-39
    • West, C.1    Lesellier, E.2
  • 38
    • 33750353564 scopus 로고    scopus 로고
    • Supercritical fluid chromatography-tandem mass spectrometry for fast bioanalysis of R/S-warfarin in human plasma
    • DOI 10.1016/j.jpba.2006.05.025, PII S0731708506004201
    • Coe RA, Rathe JO, Lee JW. Supercritical fuid chromatography-tandem mass spectrometry for fast bioanalysis of R/S-warfarin in human plasma. J. Pharm. Biomed. Anal. 42(5), 573-580 (2006) (Pubitemid 44636098)
    • (2006) Journal of Pharmaceutical and Biomedical Analysis , vol.42 , Issue.5 , pp. 573-580
    • Coe, R.A.1    Rathe, J.O.2    Lee, J.W.3
  • 39
    • 18144376699 scopus 로고    scopus 로고
    • Integration of supercritical fluid chromatography into drug discovery as a routine support tool: Part I. Fast chiral screening and purification
    • DOI 10.1016/j.chroma.2005.03.073
    • White C Integration of supercritical fuid chromatography into drug discovery as a routine support tool. Part I. fast chiral screening and purifcation. J. Chromatogr. A 1074(1-2), 163-173 (2005). (Pubitemid 40615054)
    • (2005) Journal of Chromatography A , vol.1074 , Issue.1-2 , pp. 163-173
    • White, C.1
  • 41
    • 79951933431 scopus 로고    scopus 로고
    • Bioanalytical applications using supercritical fuid techniques
    • Rios A, Zougagh M, de Andres F. Bioanalytical applications using supercritical fuid techniques. Bioanalysis 2(1), 9-25 (2010).
    • (2010) Bioanalysis , vol.2 , Issue.1 , pp. 9-25
    • Rios, A.1    Zougagh, M.2    De Andres, F.3
  • 42
    • 18144418167 scopus 로고    scopus 로고
    • Integration of supercritical fluid chromatography into drug discovery as a routine support tool: II. Investigation and evaluation of supercritical fluid chromatography for achiral batch purification
    • DOI 10.1016/j.chroma.2005.02.087
    • White C, Burnett J. Integration of supercritical fuid chromatography into drug discovery as a routine support tool. II. Investigation and evaluation of supercritical fuid chromatography for achiral batch purifcation. J. Chromatogr. A 1074(1-2), 175-185 (2005). (Pubitemid 40615055)
    • (2005) Journal of Chromatography A , vol.1074 , Issue.1-2 , pp. 175-185
    • White, C.1    Burnett, J.2
  • 43
    • 62549089304 scopus 로고    scopus 로고
    • Supercritical fuid chromatography (SFC) as a green chromatographic technique to support rapid development of pharmaceutical candidates
    • Da Silva JO, Yip HS, Hegde V. Supercritical fuid chromatography (SFC) as a green chromatographic technique to support rapid development of pharmaceutical candidates. Am. Pharm. Rev. 12(1), 98-104 (2009).
    • (2009) Am. Pharm. Rev. , vol.12 , Issue.1 , pp. 98-104
    • Da Silva, J.O.1    Yip, H.S.2    Hegde, V.3
  • 44
    • 33845533193 scopus 로고    scopus 로고
    • Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry
    • DOI 10.1021/ac0615807
    • Venter A, Sojka PE, Cooks RG. Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry. Anal. Chem. 78(24), 8549-8555 (2006). (Pubitemid 44927636)
    • (2006) Analytical Chemistry , vol.78 , Issue.24 , pp. 8549-8555
    • Venter, A.1    Sojka, P.E.2    Cooks, R.G.3
  • 45
    • 17644408113 scopus 로고    scopus 로고
    • Versatile new ion source for the analysis of materials in open air under ambient conditions
    • DOI 10.1021/ac050162j
    • Cody RB, Laramee JA, Durst HD. Versatile new ion source for the analysis of materials in open air under ambient conditions. Anal. Chem. 77(8), 2297-2302 (2005). (Pubitemid 40562727)
    • (2005) Analytical Chemistry , vol.77 , Issue.8 , pp. 2297-2302
    • Cody, R.B.1    Laramee, J.A.2    Durst, H.D.3
  • 46
    • 74249110049 scopus 로고    scopus 로고
    • Evaluation and performance of desorption electrospray ionization using a triple quadrupole mass spectrometer for quantitation of pharmaceuticals in plasma
    • Kennedy JH, Wiseman JM. Evaluation and performance of desorption electrospray ionization using a triple quadrupole mass spectrometer for quantitation of pharmaceuticals in plasma. Rapid Commun. Mass Spectrom. 24(3), 309-314 (2010).
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , Issue.3 , pp. 309-314
    • Kennedy, J.H.1    Wiseman, J.M.2
  • 47
    • 57649221982 scopus 로고    scopus 로고
    • Direct analysis of liquid samples by desorption electrospray ionization-mass spectrometry (DESI-MS)
    • Miao Z, Chen H. Direct analysis of liquid samples by desorption electrospray ionization-mass spectrometry (DESI-MS). J. Am. Soc Mass Spectrom. 20(1), 10-19 (2009).
    • (2009) J. Am. Soc Mass Spectrom. , vol.20 , Issue.1 , pp. 10-19
    • Miao, Z.1    Chen, H.2
  • 48
    • 58249091640 scopus 로고    scopus 로고
    • Bioanalysis without sample cleanup or chromatography: The evaluation and initial implementation of direct analysis in real time ionization mass spectrometry for the quantifcation of drugs in biological matrixes
    • Yu S, Crawford E, Tice J, Musselman B, Wu J-T. Bioanalysis without sample cleanup or chromatography: the evaluation and initial implementation of direct analysis in real time ionization mass spectrometry for the quantifcation of drugs in biological matrixes. Anal. Chem. 81(1), 193-202 (2009).
    • (2009) Anal. Chem. , vol.81 , Issue.1 , pp. 193-202
    • Yu, S.1    Crawford, E.2    Tice, J.3    Musselman, B.4    Wu, J.-T.5
  • 49
    • 58149184689 scopus 로고    scopus 로고
    • Quantifcation of small molecules in plasma with direct analysis in real time tandem mass spectrometry, without sample preparation and liquid chromatographic separation
    • Zhao Y, Lam M, Wu D, Mak R. Quantifcation of small molecules in plasma with direct analysis in real time tandem mass spectrometry, without sample preparation and liquid chromatographic separation. Rapid Commun. Mass Spectrom. 22(20), 3217-3224 (2008).
    • (2008) Rapid Commun. Mass Spectrom. , vol.22 , Issue.20 , pp. 3217-3224
    • Zhao, Y.1    Lam, M.2    Wu, D.3    Mak, R.4
  • 50
    • 77149137678 scopus 로고    scopus 로고
    • Molecular imaging of adrenal gland by desorption electrospray ionization mass spectrometry
    • Wu C, Ifa DR, Manicke NE, Cooks RG. Molecular imaging of adrenal gland by desorption electrospray ionization mass spectrometry Analyst 135(1), 28-32 (2010).
    • (2010) Analyst , vol.135 , Issue.1 , pp. 28-32
    • Wu, C.1    Ifa, D.R.2    Manicke, N.E.3    Cooks, R.G.4
  • 52
    • 60149088257 scopus 로고    scopus 로고
    • Pharmaceutical cleaning validation using non-proximate large-area desorption electrospray ionization mass spectrometry Rapid Commun
    • Soparawalla S, Salazar GA, Perry RH, Nicholas M, Cooks RG. Pharmaceutical cleaning validation using non-proximate large-area desorption electrospray ionization mass spectrometry Rapid Commun. Mass Spectrom. 23(1), 131-137 (2009)
    • (2009) Mass Spectrom. , vol.23 , Issue.1 , pp. 131-137
    • Soparawalla, S.1    Salazar, G.A.2    Perry, R.H.3    Nicholas, M.4    Cooks, R.G.5
  • 53
    • 60549100132 scopus 로고    scopus 로고
    • Desorption electrospray ionization mass spectrometry for trace analysis of agrochemicals in food
    • Garcia-Reyes J, Jackson A, Molina-Diaz A, Cooks GR: Desorption electrospray ionization mass spectrometry for trace analysis of agrochemicals in food. Anal. Chem. 81(2), 820-829 (2009).
    • (2009) Anal. Chem. , vol.81 , Issue.2 , pp. 820-829
    • Garcia-Reyes, J.1    Jackson, A.2    Molina-Diaz, A.3    Cooks, G.R.4
  • 54
    • 77950151355 scopus 로고    scopus 로고
    • Ambient pressure desorption ionization mass spectrometry in support of preclinical pharmaceutical development
    • Helmy R, Schafer W, Buhler L et al. Ambient pressure desorption ionization mass spectrometry in support of preclinical pharmaceutical development. Org. Process Res. Dev. 14(2) 386-392 (2010).
    • (2010) Org. Process Res. Dev. , vol.14 , Issue.2 , pp. 386-392
    • Helmy, R.1    Schafer, W.2    Buhler, L.3
  • 55
    • 49449100347 scopus 로고    scopus 로고
    • Versatile platform employing desorption electrospray ionization mass spectrometry for high-throughput analysis
    • Ma X, Zhao M, Lin Z, Zhang S, Yang C, Zhang X. Versatile platform employing desorption electrospray ionization mass spectrometry for high-throughput analysis. Anal. Chem. 80(15), 6131-6136 (2008).
    • (2008) Anal. Chem. , vol.80 , Issue.15 , pp. 6131-6136
    • Ma, X.1    Zhao, M.2    Lin, Z.3    Zhang, S.4    Yang, C.5    Zhang, X.6
  • 56
    • 58249091400 scopus 로고    scopus 로고
    • High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry
    • Manicke NE, Kistler T, Ifa DR, Cooks RG, Ouyang Z. high-throughput quantitative analysis by desorption electrospray ionization mass spectrometry J. Am. Soc Mass Spectrom. 20(2), 321-325 (2009).
    • (2009) J. Am. Soc Mass Spectrom. , vol.20 , Issue.2 , pp. 321-325
    • Manicke, N.E.1    Kistler, T.2    Ifa, D.R.3    Cooks, R.G.4    Ouyang, Z.5
  • 58
    • 70349111110 scopus 로고    scopus 로고
    • Rapid, direct analysis of cholesterol by charge labeling in reactive desorption electrospray ionization
    • Wu C, Ifa DR, Manicke NE, Cooks RG. Rapid, direct analysis of cholesterol by charge labeling in reactive desorption electrospray ionization. Anal. Chem. 81(18), 7618-7624 (2009).
    • (2009) Anal. Chem. , vol.81 , Issue.18 , pp. 7618-7624
    • Wu, C.1    Ifa, D.R.2    Manicke, N.E.3    Cooks, R.G.4
  • 59
    • 79953246226 scopus 로고
    • Recycling of solvent mixtures. Acetonitrile wastes
    • Nosko S, Burger D. Recycling of solvent mixtures. Acetonitrile wastes. Labor Praxis 17(2), 51-55 (1993).
    • (1993) Labor Praxis , vol.17 , Issue.2 , pp. 51-55
    • Nosko, S.1    Burger, D.2
  • 60
    • 79953253129 scopus 로고    scopus 로고
    • Recovery of acetonitrile from chromatographic waste
    • Stepnowski P. Recovery of acetonitrile from chromatographic waste. Oils Environ. Proc Int. Conf. 4th 506-509 (2005).
    • (2005) Oils Environ. Proc Int. Conf. 4th , pp. 506-509
    • Stepnowski, P.1
  • 61
    • 77949803629 scopus 로고    scopus 로고
    • Direct analysis of dried blood spots utilizing desorption electrospray ionization (DESI) mass spectrometry
    • Wiseman JM, Evans CA, Bowen CL, Kennedy JH. Direct analysis of dried blood spots utilizing desorption electrospray ionization (DESI) mass spectrometry Analyst 135(4), 720-725 (2010).
    • (2010) Analyst , vol.135 , Issue.4 , pp. 720-725
    • Wiseman, J.M.1    Evans, C.A.2    Bowen, C.L.3    Kennedy, J.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.