1
-
-
0033628937
-
Biological reactions to wear debris in total joint replacement
-
DOI 10.1243/0954411001535219
-
Ingham, E. and Fisher, J. Biological reactions to wear debris in total joint replacement. Proc. IMechE, Part H: J. Engineering in Medicine, 2000, 214, 21-37. DOI 10.1243/0954411001535219. (Pubitemid 32508299)
-
(2000)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.214
, Issue.1
, pp. 21-37
-
-
Ingham, E.1
Fisher, J.2
-
2
-
-
33845446298
-
Presidential guest lecture: Tribology of alternative bearings
-
Fisher, J., Jin, Z., Tipper, J., Stone, M., and Ingham, E. Presidential guest lecture: tribology of alternative bearings. Clin. Orthop. Related Res., 2006, 453, 25-34.
-
(2006)
Clin. Orthop. Related Res.
, vol.453
, pp. 25-34
-
-
Fisher, J.1
Jin, Z.2
Tipper, J.3
Stone, M.4
Ingham, E.5
-
3
-
-
0030345394
-
The frank stinchfield award. 3-dimensional sliding/contact computational simulation of total hip wear
-
Maxian, T. A., Brown, T. D., Pedersen, D. R., and Callaghan, J. J. The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear. Clin. Orthop. Related Res., 1996, 333, 41-50.
-
(1996)
Clin. Orthop. Related Res.
, vol.333
, pp. 41-50
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
4
-
-
32644440100
-
Design factors influencing performance of constrained acetabular liners: Finite element characterization
-
Bouchard, S. M., Stewart, K. J., Pedersen, D. R., Callaghan, J. J., and Brown, T. D. Design factors influencing performance of constrained acetabular liners: finite element characterization. J. Biome-chanics, 2006, 39(5), 885-893.
-
(2006)
J. Biome-chanics
, vol.39
, Issue.5
, pp. 885-893
-
-
Bouchard, S.M.1
Stewart, K.J.2
Pedersen, D.R.3
Callaghan, J.J.4
Brown, T.D.5
-
5
-
-
34247898801
-
Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxa-tion
-
Lundberg, H. J., Stewart, K. J., Pedersen, D. R., Callaghan, J. J., and Brown, T. D. Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxa-tion. J. Biomechanics, 2007, 40(8), 1676-1685.
-
(2007)
J. Biomechanics
, vol.40
, Issue.8
, pp. 1676-1685
-
-
Lundberg, H.J.1
Stewart, K.J.2
Pedersen, D.R.3
Callaghan, J.J.4
Brown, T.D.5
-
6
-
-
67649826762
-
Nicolas andry award: Clinical biomechanics of third body acceleration of total hip wear
-
Brown, T. D., Lundberg, H. J., Pedersen, D. R., and Callaghan, J. J. Nicolas Andry Award: clinical biomechanics of third body acceleration of total hip wear. Clin. Orthop. Related Res., 2009, 467(7), 1885-1897.
-
(2009)
Clin. Orthop. Related Res.
, vol.467
, Issue.7
, pp. 1885-1897
-
-
Brown, T.D.1
Lundberg, H.J.2
Pedersen, D.R.3
Callaghan, J.J.4
-
7
-
-
64749099618
-
An implicit numerical method for wear modeling applied to a hip joint prosthesis problem
-
Jourdan, F. and Samida, A. An implicit numerical method for wear modeling applied to a hip joint prosthesis problem. Comp. Meth. Appl. Mech. Engng, 2009, 198(27-29), 2209-2217.
-
(2009)
Comp. Meth. Appl. Mech. Engng
, vol.198
, Issue.27-29
, pp. 2209-2217
-
-
Jourdan, F.1
Samida, A.2
-
8
-
-
70350228619
-
Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate following press-fit implantation
-
Ong, K. L., Rundell, S., Liepins, I., Laurent, R., Markel, D., and Kurtz, S. M. Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate following press-fit implantation. J. Orthop. Res., 2009, 27(11), 1467-1472
-
(2009)
J. Orthop. Res.
, vol.27
, Issue.11
, pp. 1467-1472
-
-
Ong, K.L.1
Rundell, S.2
Liepins, I.3
Laurent, R.4
Markel, D.5
Kurtz, S.M.6
-
9
-
-
13344270633
-
Contact and rubbing of flat surfaces
-
Archard, J. F. Contact and rubbing of flat surfaces. J. App. Phys., 1953, 24(8), 981-988.
-
(1953)
J. App. Phys.
, vol.24
, Issue.8
, pp. 981-988
-
-
Archard, J.F.1
-
10
-
-
67649499840
-
In-silico wear prediction for knee replacements-methodology and corroboration
-
Strickland, M. A. and Taylor, M. In-silico wear prediction for knee replacements-methodology and corroboration. J. Biomechanics, 2009, 42(10), 1469-1474.
-
(2009)
J. Biomechanics
, vol.42
, Issue.10
, pp. 1469-1474
-
-
Strickland, M.A.1
Taylor, M.2
-
11
-
-
55549102966
-
Predictive modelling of cervical disc implant wear
-
de Jongh, C. U., Basson, A. H., and Scheffer, C. Predictive modelling of cervical disc implant wear. J. Biomechanics, 2008, 41(15), 3177-3183.
-
(2008)
J. Biomechanics
, vol.41
, Issue.15
, pp. 3177-3183
-
-
De Jongh, C.U.1
Basson, A.H.2
Scheffer, C.3
-
12
-
-
0031259388
-
The influence of stress conditions on the wear of UHMWPE for total joint replacements
-
Barbour, P. S., Barton, D. C., and Fisher, J. The influence of stress conditions on the wear of UHMWPE for total joint replacements. J. Mater. Sci.: Mater. in Med., 1997, 8(10), 603-611.
-
(1997)
J. Mater. Sci.: Mater. in Med.
, vol.8
, Issue.10
, pp. 603-611
-
-
Barbour, P.S.1
Barton, D.C.2
Fisher, J.3
-
13
-
-
8644278179
-
Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-high molecular weight polyethylene contacts?
-
DOI: 10.1243/095441104322983997
-
Vassiliou, K. and Unsworth, A. Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-high molecular weight polyethylene contacts? Proc. IMechE, Part H: J. Engineering in Medicine, 2004, 218(2), 101-107. DOI: 10.1243/095441104322983997.
-
(2004)
Proc. IMechE Part H: J. Engineering in Medicine
, vol.218
, Issue.2
, pp. 101-107
-
-
Vassiliou, K.1
Unsworth, A.2
-
14
-
-
38349051929
-
Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE
-
Kang, L., Galvin, A. L., Brown, T. D., Jin, Z., and Fisher, J. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. J. Biomechanics, 2008a, 41(2), 340-346.
-
(2008)
J. Biomechanics
, vol.41
, Issue.2
, pp. 340-346
-
-
Kang, L.1
Galvin, A.L.2
Brown, T.D.3
Jin, Z.4
Fisher, J.5
-
15
-
-
64549109722
-
Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: Effect of head diameter
-
Kang, L., Galvin, A. L., Jin, Z., and Fisher, J. Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: Effect of head diameter. J. Biome-chanics, 2009, 42(7), 912-918.
-
(2009)
J. Biome-chanics
, vol.42
, Issue.7
, pp. 912-918
-
-
Kang, L.1
Galvin, A.L.2
Jin, Z.3
Fisher, J.4
-
16
-
-
0347516482
-
Microscopic asperity contact and deformation of UHMWPE bearing surfaces. Proc. IMechE
-
DOI: 10.1243/09544110360729117
-
Wang, F., Jin, Z., McEwen, H. M., and Fisher, J. Microscopic asperity contact and deformation of UHMWPE bearing surfaces. Proc. IMechE, Part H: J. Engineering in Medicine, 2003, 217, 477-490. DOI: 10.1243/09544110360729117.
-
(2003)
Part H: J. Engineering in Medicine
, vol.217
, pp. 477-490
-
-
Wang, F.1
Jin, Z.2
McEwen, H.M.3
Fisher, J.4
-
17
-
-
68149149081
-
Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses
-
Galvin, A. L., Kang, L., Udofia, I., Jennings, L. M., McEwen, H. M., Jin, Z. M., and Fisher, J. Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses. J. Biomechanics, 2009, 42(12), 1898-1902.
-
(2009)
J. Biomechanics
, vol.42
, Issue.12
, pp. 1898-1902
-
-
Galvin, A.L.1
Kang, L.2
Udofia, I.3
Jennings, L.M.4
McEwen, H.M.5
Jin, Z.M.6
Fisher, J.7
-
18
-
-
0035280295
-
A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding
-
DOI 10.1016/S0043-1648(00)00522-6, PII S0043164800005226
-
Wang, A. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding. Wear, 2001, 248(1-2), 38-47. (Pubitemid 32241655)
-
(2001)
Wear
, vol.248
, Issue.1-2
, pp. 38-47
-
-
Wang, A.1
-
19
-
-
38749145487
-
Development of computational wear simulation of metal-on-metal hip resurfacing replacements
-
Liu, F., Leslie, I., Williams, S., Fisher, J., and Jin, Z. Development of computational wear simulation of metal-on-metal hip resurfacing replacements. J. Biomechanics, 2008, 41(3), 686-694.
-
(2008)
J. Biomechanics
, vol.41
, Issue.3
, pp. 686-694
-
-
Liu, F.1
Leslie, I.2
Williams, S.3
Fisher, J.4
Jin, Z.5
-
20
-
-
33947375583
-
Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations
-
DOI: 10.1243/ 09544119JEIM99
-
Galvin, A. L., Tipper, J. L., Jennings, L. M., Stone, M. H., Jin, Z. M., Ingham, E., and Fisher, J. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations. Proc. IMechE, Part H: J. Engineering in Medicine, 2007, 221(H1), 1-10. DOI: 10.1243/ 09544119JEIM99.
-
(2007)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.221
, Issue.H1
, pp. 1-10
-
-
Galvin, A.L.1
Tipper, J.L.2
Jennings, L.M.3
Stone, M.H.4
Jin, Z.M.5
Ingham, E.6
Fisher, J.7
-
21
-
-
58149295463
-
Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure
-
DOI: 10.1243/09544119JEIM431
-
Kang, L., Galvin, A. L., Brown, T. D., Jin, Z., and Fisher, J. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure. Proc. IMechE, Part H: J. Engineering in Medicine, 2008b, 222, 1049-1064. DOI: 10.1243/09544119JEIM431.
-
(2008)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.222
, pp. 1049-1064
-
-
Kang, L.1
Galvin, A.L.2
Brown, T.D.3
Jin, Z.4
Fisher, J.5
-
22
-
-
0025343488
-
Effect of femoral head size on wear of the polyethylene acetabular component
-
Livermore, J., Ilstrup, D., and Morrey, B. Effect of femoral head size on wear of the polyethylene acetabular component. J. Bone Jt Surg., 1990, 72A, 518-528.
-
(1990)
J. Bone Jt Surg.
, vol.72 A
, pp. 518-528
-
-
Livermore, J.1
Ilstrup, D.2
Morrey, B.3
-
23
-
-
0023007566
-
The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
-
Bartel, D. L., Bicknell, V. L., and Wright, T. M. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J. Bone Jt Surg., 1986, 68A(7), 1041-1051.
-
(1986)
J. Bone Jt Surg.
, vol.68 A
, Issue.7
, pp. 1041-1051
-
-
Bartel, D.L.1
Bicknell, V.L.2
Wright, T.M.3
-
24
-
-
0035235398
-
Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement
-
DOI 10.1243/0954411011533698
-
Wang, A., Essner, A., and Klein, R. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement. Proc. IMechE, Part H: J. Engineering in Medicine, 2001, 215(2), 133-139. DOI 10.1243/0954411011533698 (Pubitemid 34459331)
-
(2001)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.215
, Issue.2
, pp. 133-139
-
-
Wang, A.1
Essner, A.2
Klein, R.3
|