메뉴 건너뛰기




Volumn 217, Issue 6, 2003, Pages 477-490

Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces

Author keywords

Artificial hip joint; Asperity contact; Topography; UHMWPE

Indexed keywords

FAST FOURIER TRANSFORMS; FINITE DIFFERENCE METHOD; HIP PROSTHESES; PLASTIC DEFORMATION; SURFACE ROUGHNESS; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; DEFORMATION; MOLECULAR WEIGHT; POLYETHYLENES; SURFACE TOPOGRAPHY; TOPOGRAPHY; TRIBOLOGY;

EID: 0347516482     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544110360729117     Document Type: Article
Times cited : (29)

References (22)
  • 2
    • 0032945469 scopus 로고    scopus 로고
    • Current concepts review-Wear in total hip and knee replacements
    • Schmalzried, T. P. and Callaghan, J. J. Current concepts review-Wear in total hip and knee replacements. J. Bone Joint Surg. (A), 1999, 81, 115-136.
    • (1999) J. Bone Joint Surg. (A) , vol.81 , pp. 115-136
    • Schmalzried, T.P.1    Callaghan, J.J.2
  • 3
    • 0022107624 scopus 로고
    • The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
    • Bartel, D. L., Burstein, A. H., Toda, M. D. and Edwards, D. L. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. Trans. ASME, J. Biomech. Engng, 1985, 107(3), 193-199.
    • (1985) Trans. ASME, J. Biomech. Engng , vol.107 , Issue.3 , pp. 193-199
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 4
    • 0029253653 scopus 로고
    • The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses
    • Barbour, P. S. M., Barton, D. C. and Fisher, J. The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses. Wear, 1995, 181(1), 250-257.
    • (1995) Wear , vol.181 , Issue.1 , pp. 250-257
    • Barbour, P.S.M.1    Barton, D.C.2    Fisher, J.3
  • 5
    • 0035235398 scopus 로고    scopus 로고
    • Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement
    • Wang, A., Essner, A. and Klein, R. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215(H2), 133-139.
    • Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001 , vol.215 , Issue.H2 , pp. 133-139
    • Wang, A.1    Essner, A.2    Klein, R.3
  • 6
    • 0031594091 scopus 로고    scopus 로고
    • Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
    • Wang, A., Essner, A., Polineni, V. K. Stark, C. and Dumbleton, J. H. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribology Int., 1998, 31(1-3), 17-33.
    • (1998) Tribology Int. , vol.31 , Issue.1-3 , pp. 17-33
    • Wang, A.1    Essner, A.2    Polineni, V.K.3    Stark, C.4    Dumbleton, J.H.5
  • 7
    • 0034806870 scopus 로고    scopus 로고
    • Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics
    • Benson, L. C., DesJardins, J. D. and LaBerge, M. Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics. J. Biomed. Mater. Res., 2001, 58(5), 496-504.
    • (2001) J. Biomed. Mater. Res. , vol.58 , Issue.5 , pp. 496-504
    • Benson, L.C.1    DesJardins, J.D.2    LaBerge, M.3
  • 8
    • 0032108310 scopus 로고    scopus 로고
    • Surface topography of retrieved PCA acetabular liners: Proposal of a novel wear mechanism
    • Elfick, A. P., Hall, R. M., Unsworth, A. and Pinder, I. M. Surface topography of retrieved PCA acetabular liners: proposal of a novel wear mechanism. J. Mater. Sci. Lett., 1998, 17(13), 1085-1088.
    • (1998) J. Mater. Sci. Lett. , vol.17 , Issue.13 , pp. 1085-1088
    • Elfick, A.P.1    Hall, R.M.2    Unsworth, A.3    Pinder, I.M.4
  • 9
    • 0027575844 scopus 로고
    • Macroscopic and microscopic wear mechanisms in ultra-high-molecular-weight polyethylene
    • Cooper, J. R., Dowson, D. and Fisher, J. Macroscopic and microscopic wear mechanisms in ultra-high-molecular-weight polyethylene. Wear, 1993, 162(A), 378-384.
    • (1993) Wear , vol.162 , Issue.A , pp. 378-384
    • Cooper, J.R.1    Dowson, D.2    Fisher, J.3
  • 10
    • 0033800071 scopus 로고    scopus 로고
    • Surface morphology and wear mechanisms of four clinically relevant biomaterials after hip simulator testing
    • Kurtz, S. M., Muhlstein, C. and Edidin, A. A. Surface morphology and wear mechanisms of four clinically relevant biomaterials after hip simulator testing. J. Biomed. Mater. Res., 2000, 52, 447-459.
    • (2000) J. Biomed. Mater. Res. , vol.52 , pp. 447-459
    • Kurtz, S.M.1    Muhlstein, C.2    Edidin, A.A.3
  • 11
    • 0035002965 scopus 로고    scopus 로고
    • Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study
    • Yamamoto, K, Clarke, I. C., Masaoka, T., Oonishi, H., Williams, P. A., Good, V. D. and Imakiire, A. Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study. J. Biomed. Mater. Res., 2001, 56(1), 65-73.
    • (2001) J. Biomed. Mater. Res. , vol.56 , Issue.1 , pp. 65-73
    • Yamamoto, K.1    Clarke, I.C.2    Masaoka, T.3    Oonishi, H.4    Williams, P.A.5    Good, V.D.6    Imakiire, A.7
  • 12
    • 0036380423 scopus 로고    scopus 로고
    • Deconvolution of surface topology for quantification of initial wear in highly cross-linked acetabular components for THA
    • Kurtz, S. M., Turner, J. J., Herr, M. and Edidin, A. A. Deconvolution of surface topology for quantification of initial wear in highly cross-linked acetabular components for THA. J. Biomed. Mater. Res., 2002, 63(5), 492-500.
    • (2002) J. Biomed. Mater. Res. , vol.63 , Issue.5 , pp. 492-500
    • Kurtz, S.M.1    Turner, J.J.2    Herr, M.3    Edidin, A.A.4
  • 14
    • 0035217940 scopus 로고    scopus 로고
    • Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene-a new concept
    • Muratoglu, O. K., Bragdon, C. R., O'Connor, D, Perinchief, R. S., Estok, D. M., Jasty, M. and Harris, W. H. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene-A new concept. J. Arthroplasty, 2001, 16(8), 24-30 (Suppl.).
    • (2001) J. Arthroplasty , vol.16 , Issue.8 SUPPL. , pp. 24-30
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3    Perinchief, R.S.4    Estok, D.M.5    Jasty, M.6    Harris, W.H.7
  • 16
    • 0033178826 scopus 로고    scopus 로고
    • Unified wear model for highly crosslinked ultra-high molecular weight polyethylene (UHMWPE)
    • Muratoglu, O. K., Bragdon, C. R., O'Connor, D., Jasty, M., Harris, W. H., Gul, R. and McGarry, F. Unified wear model for highly crosslinked ultra-high molecular weight polyethylene (UHMWPE). J. Biomater., 1999, 20(16), 1463-1470.
    • (1999) J. Biomater. , vol.20 , Issue.16 , pp. 1463-1470
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3    Jasty, M.4    Harris, W.H.5    Gul, R.6    McGarry, F.7
  • 18
    • 0032815159 scopus 로고    scopus 로고
    • A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene
    • Endo, M. M., Barbour, P. S. M., Barton, D. C., Wroblewski, B. M., Fisher, J., Tipper, J. L., Ingham, E. and Stone, M H. A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene. Bio-Med. Mater. and Engng, 1999, 9(2), 113-124.
    • (1999) Bio-Med. Mater. and Engng , vol.9 , Issue.2 , pp. 113-124
    • Endo, M.M.1    Barbour, P.S.M.2    Barton, D.C.3    Wroblewski, B.M.4    Fisher, J.5    Tipper, J.L.6    Ingham, E.7    Stone, M.H.8
  • 19
    • 0034253530 scopus 로고    scopus 로고
    • A versatile method of discrete convolution and FFT (DC-FFT) for contact analyses
    • Liu, S. B., Wang, Q. and Liu, G. A versatile method of discrete convolution and FFT (DC-FFT) for contact analyses. Wear, 2000, 243(1-2), 101-111.
    • (2000) Wear , vol.243 , Issue.1-2 , pp. 101-111
    • Liu, S.B.1    Wang, Q.2    Liu, G.3
  • 22
    • 0036956489 scopus 로고    scopus 로고
    • Nanotribology of CoCr-UHMWPE TJR prosthesis using atomic force microscopy
    • Ho, S. P., Carpick, R. W., Boland, T. and LaBerge, M. Nanotribology of CoCr-UHMWPE TJR prosthesis using atomic force microscopy. Wear, 2002, 253(11-12), 1145-1155.
    • (2002) Wear , vol.253 , Issue.11-12 , pp. 1145-1155
    • Ho, S.P.1    Carpick, R.W.2    Boland, T.3    LaBerge, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.