메뉴 건너뛰기




Volumn 218, Issue 2, 2004, Pages 101-107

Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-high molecular weight polyethylene contacts?

Author keywords

Contact stress; Load; Pin on plate set up; Ultra high molecular weight polyethylene wear

Indexed keywords

MATHEMATICAL MODELS; MOLECULAR WEIGHT; STAINLESS STEEL; STRESSES; SURFACE ROUGHNESS; WEAR OF MATERIALS; JOINT PROSTHESES; LOADING; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES;

EID: 8644278179     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/095441104322983997     Document Type: Article
Times cited : (47)

References (20)
  • 1
    • 0015555257 scopus 로고
    • Dry bearings: A survey of materials and factors affecting their performance
    • Lancaster, J. K. Dry bearings: a survey of materials and factors affecting their performance. Tribology, 1973, 6, 219-251.
    • (1973) Tribology , vol.6 , pp. 219-251
    • Lancaster, J.K.1
  • 3
    • 13344270633 scopus 로고
    • Contact and rubbing of flat surfaces
    • Archard, J. F. Contact and rubbing of flat surfaces. J. Appl. Phys., 1953, 24(8), 981-988.
    • (1953) J. Appl. Phys. , vol.24 , Issue.8 , pp. 981-988
    • Archard, J.F.1
  • 4
    • 0029253653 scopus 로고
    • The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses
    • Barbour, P. S. M., Barton, D. C. and Fisher, J. The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses. Wear, 1995, 181, 250-257.
    • (1995) Wear , vol.181 , pp. 250-257
    • Barbour, P.S.M.1    Barton, D.C.2    Fisher, J.3
  • 5
    • 0035235398 scopus 로고    scopus 로고
    • Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement
    • Wang, A., Essner, A. and Klein, R. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement. Proc. Inst. Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215(H2), 133-140.
    • (2001) Proc. Inst. Mech. Engrs, Part H: J. Engineering in Medicine , vol.215 , Issue.H2 , pp. 133-140
    • Wang, A.1    Essner, A.2    Klein, R.3
  • 6
    • 0020970905 scopus 로고
    • On the pressure dependence of the wear of ultrahigh molecular weight polyethylene
    • Rose, R. M., Goldfarb, H. V., Ellis, E. and Crugnola, A. M. On the pressure dependence of the wear of ultrahigh molecular weight polyethylene. Wear, 1983, 92, 99-111.
    • (1983) Wear , vol.92 , pp. 99-111
    • Rose, R.M.1    Goldfarb, H.V.2    Ellis, E.3    Crugnola, A.M.4
  • 7
    • 0018537364 scopus 로고
    • Contact pressure dependence of wear rates of ultra high molecular weight polyethylene
    • Rostoker, W. and Galante, J. O. Contact pressure dependence of wear rates of ultra high molecular weight polyethylene. J. Biomed. Mater. Res., 1979, 13, 957-964.
    • (1979) J. Biomed. Mater. Res. , vol.13 , pp. 957-964
    • Rostoker, W.1    Galante, J.O.2
  • 8
    • 0035727965 scopus 로고    scopus 로고
    • The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements
    • Sathasivam, S., Walker, P. S., Campbell, P. and Rayner K. The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. J. Biomed. Mater. Res., Appl. Biomat., 2001, 58(3), 282-290.
    • (2001) J. Biomed. Mater. Res., Appl. Biomat. , vol.58 , Issue.3 , pp. 282-290
    • Sathasivam, S.1    Walker, P.S.2    Campbell, P.3    Rayner, K.4
  • 9
    • 0038546396 scopus 로고    scopus 로고
    • Effects of contact area and stress on the volumetric wear of ultra-high molecular weight polyethylene
    • Mazzucco, D. and Spector, M. Effects of contact area and stress on the volumetric wear of ultra-high molecular weight polyethylene. Wear, 2003, 254(5-6), 514-522.
    • (2003) Wear , vol.254 , Issue.5-6 , pp. 514-522
    • Mazzucco, D.1    Spector, M.2
  • 10
    • 0034999364 scopus 로고    scopus 로고
    • Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples
    • Scholes, S. C. and Unsworth, A. Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples. J. Mater. Sci. Mater. Medicine. 2001, 12(4), 299-303.
    • (2001) J. Mater. Sci. Mater. Medicine. , vol.12 , Issue.4 , pp. 299-303
    • Scholes, S.C.1    Unsworth, A.2
  • 11
    • 0033635152 scopus 로고    scopus 로고
    • A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel
    • Joyce, T. J., Monk, D., Scholes, S. C., Unsworth, A. A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel. Bio Med. Mater. Engng, 2000, 10(3-4), 241-249.
    • (2000) Bio Med. Mater. Engng , vol.10 , Issue.3-4 , pp. 241-249
    • Joyce, T.J.1    Monk, D.2    Scholes, S.C.3    Unsworth, A.4
  • 12
    • 0032126428 scopus 로고    scopus 로고
    • A multidirectional motion pin-on-disk wear test method for prosthetic joint materials
    • Saikko, V. A multidirectional motion pin-on-disk wear test method for prosthetic joint materials. J. Biomed. Mater. Res., 1998, 41(1), 58-64.
    • (1998) J. Biomed. Mater. Res. , vol.41 , Issue.1 , pp. 58-64
    • Saikko, V.1
  • 14
    • 0003908561 scopus 로고    scopus 로고
    • The tribology of hard bearing surfaces for use in hip prostheses
    • PhD thesis, University of Durham, Durham
    • Scholes, S. C. The tribology of hard bearing surfaces for use in hip prostheses. PhD thesis, University of Durham, Durham, 1999.
    • (1999)
    • Scholes, S.C.1
  • 15
    • 0022108299 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. I: Charnley prostheses with polytetrafluoroethylene acetabular cups
    • Dowson, D. and Wallbridge, N. C. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. I: Charnley prostheses with polytetrafluoroethylene acetabular cups. Wear, 1985, 104, 203-215.
    • (1985) Wear , vol.104 , pp. 203-215
    • Dowson, D.1    Wallbridge, N.C.2
  • 17
    • 8644228294 scopus 로고    scopus 로고
    • The influence of stress and load on the wear of UHMWPE pins on stainless steel plates
    • MEng thesis, University of Durham, Durham
    • Lloyd, A. The influence of stress and load on the wear of UHMWPE pins on stainless steel plates. MEng thesis, University of Durham, Durham, 2000.
    • (2000)
    • Lloyd, A.1
  • 18
    • 0034142667 scopus 로고    scopus 로고
    • Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: effects of counterface material, contact area, and lubricant
    • Saikko, V. and Ahlroos, T. Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: effects of counterface material, contact area, and lubricant. J. Biomed. Mater. Res. 2000, 49(2), 147-154.
    • (2000) J. Biomed. Mater. Res. , vol.49 , Issue.2 , pp. 147-154
    • Saikko, V.1    Ahlroos, T.2
  • 19
    • 0016942059 scopus 로고
    • The wear of plastic materials in the hip joint
    • Charnley, J. The wear of plastic materials in the hip joint. Plastics Rubber, 1976, 1, 59-63.
    • (1976) Plastics Rubber , vol.1 , pp. 59-63
    • Charnley, J.1
  • 20
    • 0035892402 scopus 로고    scopus 로고
    • Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device
    • Saikko, V., Calonius, O. and Keranen, J. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device. J. Biomed. Mter. Res., 2001, 57(4), 506-512.
    • (2001) J. Biomed. Mter. Res. , vol.57 , Issue.4 , pp. 506-512
    • Saikko, V.1    Calonius, O.2    Keranen, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.