-
1
-
-
0029253653
-
The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses
-
Barbour P.S.M., Barton D.C., and Fisher J. The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses. Wear 181-183 (1995) 250-257
-
(1995)
Wear
, vol.181-183
, pp. 250-257
-
-
Barbour, P.S.M.1
Barton, D.C.2
Fisher, J.3
-
3
-
-
0033252596
-
A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
-
Barbour P.S., Stone M.H., and Fisher J. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proceedings of Institute of Mechanical Engineers, Part H, Journal of Engineering in Medicine 213 (1999) 455-467
-
(1999)
Proceedings of Institute of Mechanical Engineers, Part H, Journal of Engineering in Medicine
, vol.213
, pp. 455-467
-
-
Barbour, P.S.1
Stone, M.H.2
Fisher, J.3
-
4
-
-
0022107624
-
The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
-
Bartel D.L., Burstein A.H., Toda M.D., and Edwards D.L. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. Journal of Biomechanical Engineering 107 3 (1985) 193-199
-
(1985)
Journal of Biomechanical Engineering
, vol.107
, Issue.3
, pp. 193-199
-
-
Bartel, D.L.1
Burstein, A.H.2
Toda, M.D.3
Edwards, D.L.4
-
5
-
-
0030331545
-
The importance of multidirectional motion on the wear of polyethylene
-
Bragdon C.R., O'Connor D.O., Lowenstein J.D., Jasty M., and Syniuta W.D. The importance of multidirectional motion on the wear of polyethylene. Proceedings of the Institution of Mechanical Engineers. Part H-Journal of Engineering in Medicine 210 3 (1996) 157-165
-
(1996)
Proceedings of the Institution of Mechanical Engineers. Part H-Journal of Engineering in Medicine
, vol.210
, Issue.3
, pp. 157-165
-
-
Bragdon, C.R.1
O'Connor, D.O.2
Lowenstein, J.D.3
Jasty, M.4
Syniuta, W.D.5
-
6
-
-
0036960511
-
Local head roughening as a factor contributing to variability of total hip wear: a finite element analysis
-
Brown T.D., Stewart K.J., Nieman J.C., Pedersen D.R., and Callaghan J.J. Local head roughening as a factor contributing to variability of total hip wear: a finite element analysis. Journal of Biomedical Engineering, Transactions of ASME 124 (2002) 691-698
-
(2002)
Journal of Biomedical Engineering, Transactions of ASME
, vol.124
, pp. 691-698
-
-
Brown, T.D.1
Stewart, K.J.2
Nieman, J.C.3
Pedersen, D.R.4
Callaghan, J.J.5
-
7
-
-
34447544072
-
Computational hip joint simulator for wear and heat generation
-
Fialho J.C., Fernandes P.R., Eça L., and Folgado J. Computational hip joint simulator for wear and heat generation. Journal of Biomechanics. 40 11 (2007) 2358-2366
-
(2007)
Journal of Biomechanics.
, vol.40
, Issue.11
, pp. 2358-2366
-
-
Fialho, J.C.1
Fernandes, P.R.2
Eça, L.3
Folgado, J.4
-
8
-
-
33845446298
-
Tribology of alternative bearings
-
Fisher J., Jin Z., Tipper J., Stone M., and Ingham E. Tribology of alternative bearings. Clinical Orthopaedics and Related Research 453 (2006) 25-34
-
(2006)
Clinical Orthopaedics and Related Research
, vol.453
, pp. 25-34
-
-
Fisher, J.1
Jin, Z.2
Tipper, J.3
Stone, M.4
Ingham, E.5
-
9
-
-
33947375583
-
Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations
-
Galvin A.L., Tipper J.L., Jennings L.M., Stone M.H., Jin Z.M., Ingham E., and Fisher J. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations. Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine 221 (2007) 1-10
-
(2007)
Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine
, vol.221
, pp. 1-10
-
-
Galvin, A.L.1
Tipper, J.L.2
Jennings, L.M.3
Stone, M.H.4
Jin, Z.M.5
Ingham, E.6
Fisher, J.7
-
10
-
-
18644378602
-
Quantifying multidirectional sliding motions in total knee replacements
-
Hamilton M.A., Sucec M.C., Fregly B.J., Banks S.A., and Sawyer W.G. Quantifying multidirectional sliding motions in total knee replacements. Journal of Tribology 127 (2005) 280-286
-
(2005)
Journal of Tribology
, vol.127
, pp. 280-286
-
-
Hamilton, M.A.1
Sucec, M.C.2
Fregly, B.J.3
Banks, S.A.4
Sawyer, W.G.5
-
12
-
-
84930409560
-
A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants
-
Kang L., Galvin A.L., Jin Z.M., and Fisher J. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants. Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine 220H (2006) 33-46
-
(2006)
Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine
, vol.220 H
, pp. 33-46
-
-
Kang, L.1
Galvin, A.L.2
Jin, Z.M.3
Fisher, J.4
-
13
-
-
58149295463
-
Wear simulation of UHMWPE hip implants by incorporating the effects of cross-shear and contact pressure
-
Kang L., Galvin A.L., Brown T.D., Fisher J., and Jin Z.M. Wear simulation of UHMWPE hip implants by incorporating the effects of cross-shear and contact pressure. Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine 222 (2008) 1049-1064
-
(2008)
Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine
, vol.222
, pp. 1049-1064
-
-
Kang, L.1
Galvin, A.L.2
Brown, T.D.3
Fisher, J.4
Jin, Z.M.5
-
14
-
-
38349051929
-
Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE
-
Kang L., Galvin A.L., Thomas B.D., Jin Z., and Fisher J. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. Journal of Biomechanics 41 2 (2008) 340-346
-
(2008)
Journal of Biomechanics
, vol.41
, Issue.2
, pp. 340-346
-
-
Kang, L.1
Galvin, A.L.2
Thomas, B.D.3
Jin, Z.4
Fisher, J.5
-
15
-
-
64549144716
-
Influence of cross-shear on the wear of polyethylene: A Finite Element study
-
Washington, USA, Paper No:987
-
Knight, L., McEwen, H., Fisher, J., Taylor, M., 2005. Influence of cross-shear on the wear of polyethylene: a Finite Element study. In: Proceedings of the 51st Annual Meeting of the Orthopaedic Research Society, Washington, USA, Paper No:987.
-
(2005)
Proceedings of the 51st Annual Meeting of the Orthopaedic Research Society
-
-
Knight, L.1
McEwen, H.2
Fisher, J.3
Taylor, M.4
-
18
-
-
0030198688
-
Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty
-
Maxian T.A., Brown T.D., Pedersen D.R., and Callaghan J.J. Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty. Journal of Orthopaedic Research 14 4 (1996) 668-675
-
(1996)
Journal of Orthopaedic Research
, vol.14
, Issue.4
, pp. 668-675
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
20
-
-
0030698011
-
Finite element analysis of acetabular wear-Validation, and backing and fixation effects
-
Maxian T.A., Brown T.D., Pedersen D.R., McKellop H.A., Lu B., and Callaghan J.J. Finite element analysis of acetabular wear-Validation, and backing and fixation effects. Clinical Orthopaedics and Related Research 344 (1997) 111-117
-
(1997)
Clinical Orthopaedics and Related Research
, vol.344
, pp. 111-117
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
McKellop, H.A.4
Lu, B.5
Callaghan, J.J.6
-
21
-
-
0032053277
-
Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model
-
Pietrabissa R., Raimondi M., and Di Martino E. Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model. Medical Engineering & Physics 20 3 (1998) 199-210
-
(1998)
Medical Engineering & Physics
, vol.20
, Issue.3
, pp. 199-210
-
-
Pietrabissa, R.1
Raimondi, M.2
Di Martino, E.3
-
22
-
-
0035228123
-
Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components
-
Raimondi M.T., Santambrogio C., Pietrabissa R., Raffelini F., and Molfetta L. Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components. Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine 215 (2001) 377-391
-
(2001)
Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine
, vol.215
, pp. 377-391
-
-
Raimondi, M.T.1
Santambrogio, C.2
Pietrabissa, R.3
Raffelini, F.4
Molfetta, L.5
-
23
-
-
0018611372
-
On the origins of high in vivo wear rates in polyethylene components of total joint prostheses
-
Rose R.M., Crugnola A., Ries M., Cimino W.R., Paul I., and Radin E.L. On the origins of high in vivo wear rates in polyethylene components of total joint prostheses. Clinical Orthopaedics and Related Research 145 (1979) 277-286
-
(1979)
Clinical Orthopaedics and Related Research
, Issue.145
, pp. 277-286
-
-
Rose, R.M.1
Crugnola, A.2
Ries, M.3
Cimino, W.R.4
Paul, I.5
Radin, E.L.6
-
24
-
-
33846292240
-
Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding
-
Saikko V. Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding. Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine 220H (2006) 723-731
-
(2006)
Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine
, vol.220 H
, pp. 723-731
-
-
Saikko, V.1
-
25
-
-
33845676764
-
Total hip arthroplasty wear simulation using the boundary element method
-
Sfantos G.K., and Aliabadi M.H. Total hip arthroplasty wear simulation using the boundary element method. Journal of Biomechanics 40 2 (2007) 378-389
-
(2007)
Journal of Biomechanics
, vol.40
, Issue.2
, pp. 378-389
-
-
Sfantos, G.K.1
Aliabadi, M.H.2
-
26
-
-
0036169065
-
An elastic-plastic finite element model for polyethylene wear in total hip arthroplasty
-
Teoh S.H., Chan W.H., and Thampuran R. An elastic-plastic finite element model for polyethylene wear in total hip arthroplasty. Journal of Biomechanics 35 (2002) 323-330
-
(2002)
Journal of Biomechanics
, vol.35
, pp. 323-330
-
-
Teoh, S.H.1
Chan, W.H.2
Thampuran, R.3
-
28
-
-
0347516482
-
Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces
-
Wang F.C., Jin Z.M., McEwen H., and Fisher J. Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces. Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine 217 (2003) 477-490
-
(2003)
Proceedings of the Institution of Mechanical Engineers, Journal of Engineering in Medicine
, vol.217
, pp. 477-490
-
-
Wang, F.C.1
Jin, Z.M.2
McEwen, H.3
Fisher, J.4
-
29
-
-
0037213115
-
The computer simulation of wear behavior appearing in total hip prosthesis
-
Wu J.S., Hung J.P., Shu C.S., and Chen J.H. The computer simulation of wear behavior appearing in total hip prosthesis. Computer Methods and Programmes in Biomedicine 70 1 (2003) 81-91
-
(2003)
Computer Methods and Programmes in Biomedicine
, vol.70
, Issue.1
, pp. 81-91
-
-
Wu, J.S.1
Hung, J.P.2
Shu, C.S.3
Chen, J.H.4
|