메뉴 건너뛰기




Volumn 42, Issue 12, 2009, Pages 1898-1902

Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses

Author keywords

Polyethylene wear; Total knee replacement

Indexed keywords

BEARING SURFACES; CONTACT AREAS; CONTACT STRESS; CROSS-SHEAR; CROSS-SHEAR MOTION; FUNCTION OF PRESSURE; KNEE SIMULATORS; PLATE SYSTEMS; POLYETHYLENE WEAR; SURFACE WEAR; TOTAL KNEE PROSTHESIS; TOTAL KNEE REPLACEMENT; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE; WEAR RATES;

EID: 68149149081     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.05.010     Document Type: Article
Times cited : (80)

References (27)
  • 1
    • 13344270633 scopus 로고
    • Contact and rubbing of flat surfaces
    • Archard J.F. Contact and rubbing of flat surfaces. Journal of Applied Physics 24 8 (1953) 981-988
    • (1953) Journal of Applied Physics , vol.24 , Issue.8 , pp. 981-988
    • Archard, J.F.1
  • 2
    • 0029253653 scopus 로고
    • The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses
    • Barbour P.S.M., Barton D.C., and Fisher J. The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses. Wear 181 (1995) 250-257
    • (1995) Wear , vol.181 , pp. 250-257
    • Barbour, P.S.M.1    Barton, D.C.2    Fisher, J.3
  • 5
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel D.L., Bicknell V.L., and Wright T.M. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. Journal of Bone and Joint Surgery-American Volume 68 7 (1986) 1041-1051
    • (1986) Journal of Bone and Joint Surgery-American Volume , vol.68 , Issue.7 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 8
    • 0026527293 scopus 로고
    • Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses
    • Engh G.A., Dwyer K.A., and Hanes C.K. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. Journal of Bone and Joint Surgery-British Volume 74 1 (1992) 9-17
    • (1992) Journal of Bone and Joint Surgery-British Volume , vol.74 , Issue.1 , pp. 9-17
    • Engh, G.A.1    Dwyer, K.A.2    Hanes, C.K.3
  • 10
    • 0034947632 scopus 로고    scopus 로고
    • Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants
    • Howling G.I., Barnett P.I., Tipper J.L., Stone M.H., Fisher J., and Ingham E. Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants. Journal of Biomedical Materials Research 58 4 (2001) 415-420
    • (2001) Journal of Biomedical Materials Research , vol.58 , Issue.4 , pp. 415-420
    • Howling, G.I.1    Barnett, P.I.2    Tipper, J.L.3    Stone, M.H.4    Fisher, J.5    Ingham, E.6
  • 15
    • 38349051929 scopus 로고    scopus 로고
    • Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE
    • Kang L., Galvin A.L., Brown T.D., Jin Z.M., and Fisher J. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. Journal of Biomechanics 41 (2008) 340-346
    • (2008) Journal of Biomechanics , vol.41 , pp. 340-346
    • Kang, L.1    Galvin, A.L.2    Brown, T.D.3    Jin, Z.M.4    Fisher, J.5
  • 16
    • 68149182219 scopus 로고    scopus 로고
    • Knight, L.A., Galvin, A., Jeffers, J.R.T., Hopkins, A., Fisher, J., Taylor, M., 2005. Influence of cross-shear on the wear of polyethylene: A finite element study. In: Orthopaedic Research Society. Chicago, p. 987.
    • Knight, L.A., Galvin, A., Jeffers, J.R.T., Hopkins, A., Fisher, J., Taylor, M., 2005. Influence of cross-shear on the wear of polyethylene: A finite element study. In: Orthopaedic Research Society. Chicago, p. 987.
  • 20
    • 29244471683 scopus 로고    scopus 로고
    • Survivorship analysis of 3234 primary knee arthroplasties implanted over a 26-year period-a study of eight different implant designs
    • Pradhan N.R., Gambhir A., and Porter M.L. Survivorship analysis of 3234 primary knee arthroplasties implanted over a 26-year period-a study of eight different implant designs. Knee 13 1 (2006) 7-11
    • (2006) Knee , vol.13 , Issue.1 , pp. 7-11
    • Pradhan, N.R.1    Gambhir, A.2    Porter, M.L.3
  • 21
    • 0033642582 scopus 로고    scopus 로고
    • Comparison of gas plasma and gamma irradiation in air sterilisation on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacements
    • Reeves E.A., Barton D.C., Fitzpatrick D.P., and Fisher J. Comparison of gas plasma and gamma irradiation in air sterilisation on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacements. Proceedings of the Institution of Mechanical Engineers 214 (2000) 249-255
    • (2000) Proceedings of the Institution of Mechanical Engineers , vol.214 , pp. 249-255
    • Reeves, E.A.1    Barton, D.C.2    Fitzpatrick, D.P.3    Fisher, J.4
  • 23
  • 24
    • 0024103556 scopus 로고
    • Bearing surface design in total knee replacement
    • Walker P.S. Bearing surface design in total knee replacement. Engineering in Medicine 17 4 (1988) 149-156
    • (1988) Engineering in Medicine , vol.17 , Issue.4 , pp. 149-156
    • Walker, P.S.1
  • 25
    • 0031594091 scopus 로고    scopus 로고
    • Lubrication and wear of ultra high molecular weight polyethylene in total joint replacements
    • Wang A., Essner A., Polineni V.K., Stark C., and Dumbleton J.H. Lubrication and wear of ultra high molecular weight polyethylene in total joint replacements. Tribology International 31 1-3 (1998) 17-33
    • (1998) Tribology International , vol.31 , Issue.1-3 , pp. 17-33
    • Wang, A.1    Essner, A.2    Polineni, V.K.3    Stark, C.4    Dumbleton, J.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.