메뉴 건너뛰기




Volumn 29, Issue 8, 2010, Pages 1496-1503

A comparison of three image fidelity metrics of different computational principles for JPEG2000 compressed abdomen CT images

Author keywords

Computed tomography; image compression; image fidelity metric; JPEG2000

Indexed keywords

CHARACTERISTIC CURVE; COMPRESSED IMAGES; COMPRESSION RATIOS; COMPUTED TOMOGRAPHY; CT IMAGE; DYNAMIC RANGE; IMAGE FIDELITY; JPEG 2000; LOSSLESS COMPRESSION; MULTISCALES; REFERENCE STANDARD; SECTION THICKNESS; SPEARMAN RANK CORRELATION; STRUCTURAL SIMILARITY; VISUAL ANALYSIS; VISUAL DIFFERENCE PREDICTORS;

EID: 77955310523     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2010.2049655     Document Type: Article
Times cited : (22)

References (47)
  • 1
    • 24044437885 scopus 로고    scopus 로고
    • Managing the CT data explosion: Initial experiences of archiving volumetric datasets in a mini-PACS
    • DOI 10.1007/s10278-005-5163-z
    • K. H. Lee, H. J. Lee, J. H. Kim, H. S. Kang, K. W. Lee, H. Hong, H. J. Chin, and K. S. Ha, "Managing the CT data explosion: Initial experiences of archiving volumetric datasets in a mini-PACS, " J. Digit Imag., vol.18, pp. 188-195, Sep. 2005. (Pubitemid 41215934)
    • (2005) Journal of Digital Imaging , vol.18 , Issue.3 , pp. 188-195
    • Kyoung, H.L.1    Hak, J.L.2    Jae, H.K.3    Heung, S.K.4    Kyung, W.L.5    Hong, H.6    Ho, J.C.7    Kyoo, S.H.8
  • 2
    • 17144436458 scopus 로고    scopus 로고
    • Impact of multislice CT on PACS resources
    • Apr.
    • E. P. Tamm, S. Thompson, S. L. Venable, and K. McEnery, "Impact of multislice CT on PACS resources, " J. Digit Imag., vol.15, pp. 96-101, Apr. 2002, Suppl 1.
    • (2002) J. Digit Imag. , vol.15 , Issue.SUPPL. 1 , pp. 96-101
    • Tamm, E.P.1    Thompson, S.2    Venable, S.L.3    McEnery, K.4
  • 3
    • 49149120869 scopus 로고    scopus 로고
    • The difference of compression artifacts between thin-and thick-section lungCT lmages
    • Aug.
    • V. Bajpai, K. H. Lee, B. Kim, K. J. Kim, T. J. Kim, Y. H. Kim, and H. S. Kang, "The difference of compression artifacts between thin-and thick-section lungCT lmages, "Am. J. Roentgenol., vol.191, pp. 38-43, Aug. 2008.
    • (2008) Am. J. Roentgenol. , vol.191 , pp. 38-43
    • Bajpai, V.1    Lee, K.H.2    Kim, B.3    Kim, K.J.4    Kim, T.J.5    Kim, Y.H.6    Kang, H.S.7
  • 4
    • 39049132947 scopus 로고    scopus 로고
    • Prediction of Perceptible Artifacts in JPEG2000 Compressed Abdomen CT Images Using a Perceptual Image Quality Metric
    • DOI 10.1016/j.acra.2007.10.018, PII S1076633207006289
    • B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, V. Bajpai, T. J. Kim, Y. H. Kim, C. J. Yoon, and S. Hahn, "Prediction of perceptible artifacts in JPEG2000 compressed abdomen CT images using a perceptual image quality metric, " Acad. Radiol., vol.15, pp. 314-325, Mar. 2008. (Pubitemid 351246732)
    • (2008) Academic Radiology , vol.15 , Issue.3 , pp. 314-325
    • Kim, B.1    Lee, K.H.2    Kim, K.J.3    Mantiuk, R.4    Bajpai, V.5    Kim, T.J.6    Kim, Y.H.7    Yoon, C.J.8    Hahn, S.9
  • 5
    • 38849112717 scopus 로고    scopus 로고
    • Prediction of perceptible artifacts in JPEG 2000-compressed chest CT images using mathematical and perceptual quality metrics
    • DOI 10.2214/AJR.07.2502
    • B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, S. Hahn, T. J. Kim, and Y. H. Kim, "Prediction of perceptible artifacts in JPEG2000 compressed chest CT images using mathematical and perceptual quality metrics, " Am. J. Roentgenol., vol.190, pp. 328-334, Feb. 2008. (Pubitemid 351196602)
    • (2008) American Journal of Roentgenology , vol.190 , Issue.2 , pp. 328-334
    • Kim, B.1    Lee, K.H.2    Kil, J.K.3    Mantiuk, R.4    Hahn, S.5    Tae, J.K.6    Young, H.K.7
  • 6
    • 44949237872 scopus 로고    scopus 로고
    • Artifacts in slab average-intensity-projection images reformatted from JPEG 2000 compressed thin-section abdominal CT data sets
    • Jun.
    • B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, H. R. Kim, and Y. H. Kim, "Artifacts in slab average-intensity-projection images reformatted from JPEG 2000 compressed thin-section abdominal CT data sets, " Am. J. Roentgenol., vol.190, pp. 342-350, Jun. 2008.
    • (2008) Am. J. Roentgenol. , vol.190 , pp. 342-350
    • Kim, B.1    Lee, K.H.2    Kim, K.J.3    Mantiuk, R.4    Kim, H.R.5    Kim, Y.H.6
  • 8
    • 62849123599 scopus 로고    scopus 로고
    • Regional variance of visually lossless threshold in compressed chest CT images: Lung versus mediastinum and chest wall
    • Mar.
    • T. J. Kim, K. H. Lee, B. Kim, K. J. Kim, E. J. Chun, V. Bajpai, Y. H. Kim, S. Hahn, and K. W. Lee, "Regional variance of visually lossless threshold in compressed chest CT images: Lung versus mediastinum and chest wall, " Eur. J. Radiol., vol.69, pp. 483-488, Mar. 2009.
    • (2009) Eur. J. Radiol. , vol.69 , pp. 483-488
    • Kim, T.J.1    Lee, K.H.2    Kim, B.3    Kim, K.J.4    Chun, E.J.5    Bajpai, V.6    Kim, Y.H.7    Hahn, S.8    Lee, K.W.9
  • 9
    • 34248652953 scopus 로고    scopus 로고
    • Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: Assessment of visually lossless threshold
    • Jun.
    • K. H. Lee, Y. H. Kim, B. H. Kim, K. J. Kim, T. J. Kim, H. J. Kim, and S. Hahn, "Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: Assessment of visually lossless threshold, " Eur. Radiol., vol.17, pp. 1529-1534, Jun. 2007.
    • (2007) Eur. Radiol. , vol.17 , pp. 1529-1534
    • Lee, K.H.1    Kim, Y.H.2    Kim, B.H.3    Kim, K.J.4    Kim, T.J.5    Kim, H.J.6    Hahn, S.7
  • 10
    • 34548213118 scopus 로고    scopus 로고
    • JPEG 2000 compression of abdominal CT: Difference in compression tolerance between thin-and thick-section images
    • Sep.
    • H. S. Woo, K. J. Kim, T. J. Kim, S. Hahn, B. H. Kim, Y. H. Kim, C. J. Yoon, and K. H. Lee, "JPEG 2000 compression of abdominal CT: Difference in compression tolerance between thin-and thick-section images, " Am. J. Roentgenol., vol.189, pp. 535-541, Sep. 2007.
    • (2007) Am. J. Roentgenol. , vol.189 , pp. 535-541
    • Woo, H.S.1    Kim, K.J.2    Kim, T.J.3    Hahn, S.4    Kim, B.H.5    Kim, Y.H.6    Yoon, C.J.7    Lee, K.H.8
  • 11
    • 33747608185 scopus 로고    scopus 로고
    • JPEG2000 compression of thin-section CT images of the lung: Effect of compression ratio on image quality
    • Sep.
    • H. Ringl, R. E. Schernthaner, A. A. Bankier, M. Weber, M. Prokop, C. J. Herold, and C. Schaefer-Prokop, "JPEG2000 compression of thin-section CT images of the lung: Effect of compression ratio on image quality, " Radiology, vol.240, pp. 869-877, Sep. 2006.
    • (2006) Radiology , vol.240 , pp. 869-877
    • Ringl, H.1    Schernthaner, R.E.2    Bankier, A.A.3    Weber, M.4    Prokop, M.5    Herold, C.J.6    Schaefer-Prokop, C.7
  • 12
    • 35349013622 scopus 로고    scopus 로고
    • Lossy three-dimensional JPEG2000 compression of abdominal CT images: Assessment of the visually lossless threshold and effect of compression ratio on image quality
    • Nov.
    • H. Ringl, R. E. Schernthaner, C. Kulinna-Cosentini, M. Weber, C. Schaefer-Prokop, C. J. Herold, and W. Schima, "Lossy three-dimensional JPEG2000 compression of abdominal CT images: Assessment of the visually lossless threshold and effect of compression ratio on image quality, " Radiology, vol.245, pp. 467-474, Nov. 2007.
    • (2007) Radiology , vol.245 , pp. 467-474
    • Ringl, H.1    Schernthaner, R.E.2    Kulinna-Cosentini, C.3    Weber, M.4    Schaefer-Prokop, C.5    Herold, C.J.6    Schima, W.7
  • 15
    • 25144519182 scopus 로고    scopus 로고
    • Effect of CT image compression on computer-assisted lung nodule volume measurement
    • Oct.
    • J. P. Ko, J. Chang, E. Bomsztyk, J. S. Babb, D. P. Naidich, and H. Rusinek, "Effect of CT image compression on computer-assisted lung nodule volume measurement, " Radiology, vol.237, pp. 83-88, Oct. 2005.
    • (2005) Radiology , vol.237 , pp. 83-88
    • Ko, J.P.1    Chang, J.2    Bomsztyk, E.3    Babb, J.S.4    Naidich, D.P.5    Rusinek, H.6
  • 18
    • 0034914234 scopus 로고    scopus 로고
    • CT colonography with teleradiology: Effect of lossy wavelet compression on polyp detection-initial observations
    • Aug.
    • M. E. Zalis, P. F. Hahn, R.S. Arellano, G. S. Gazelle, and P.R. Mueller, "CT colonography with teleradiology: Effect of lossy wavelet compression on polyp detection-initial observations, " Radiology, vol.220, pp. 387-392, Aug. 2001.
    • (2001) Radiology , vol.220 , pp. 387-392
    • Zalis, M.E.1    Hahn, P.F.2    Arellano, R.S.3    Gazelle, G.S.4    Mueller, P.R.5
  • 19
    • 67649576940 scopus 로고    scopus 로고
    • Objective index of image fidelity for JPEG2000 compressed body CT images
    • Jul.
    • K. J. Kim, B. Kim, K. H. Lee, R. Mantiuk, H. S. Kang, J. Seo, S. Y. Kim, and Y. H. Kim, "Objective index of image fidelity for JPEG2000 compressed body CT images, " Med. Phys., vol.36, pp. 3218-3226, Jul. 2009.
    • (2009) Med. Phys. , vol.36 , pp. 3218-3226
    • Kim, K.J.1    Kim, B.2    Lee, K.H.3    Mantiuk, R.4    Kang, H.S.5    Seo, J.6    Kim, S.Y.7    Kim, Y.H.8
  • 20
    • 49149120343 scopus 로고    scopus 로고
    • Regional difference in compression artifacts in low-dose chest CT images: Effects of mathematical and perceptual factors
    • Aug.
    • K. J. Kim, B. Kim, K. H. Lee, T. J. Kim, R. Mantiuk, H. S. Kang, and Y. H. Kim, "Regional difference in compression artifacts in low-dose chest CT images: Effects of mathematical and perceptual factors, " Am. J. Roentgenol., vol.191, pp. 30-37, Aug. 2008.
    • (2008) Am. J. Roentgenol. , vol.191 , pp. 30-37
    • Kim, K.J.1    Kim, B.2    Lee, K.H.3    Kim, T.J.4    Mantiuk, R.5    Kang, H.S.6    Kim, Y.H.7
  • 22
    • 0032202314 scopus 로고    scopus 로고
    • Perceptual quality metrics applied to still image compression
    • Nov.
    • M. P. Eckert and A. P. Bradley, "Perceptual quality metrics applied to still image compression, " Signal Process., vol.70, pp. 177-200, Nov. 1998.
    • (1998) Signal Process. , vol.70 , pp. 177-200
    • Eckert, M.P.1    Bradley, A.P.2
  • 25
    • 33745376295 scopus 로고    scopus 로고
    • A virtual image chain for perceived image quality of medical display
    • C. Marchessoux and J. Jung, "A virtual image chain for perceived image quality of medical display, " in Proc. SPIE Med. Image, 2006, pp. 77-84.
    • (2006) Proc. SPIE Med. Image , pp. 77-84
    • Marchessoux, C.1    Jung, J.2
  • 26
    • 44349090384 scopus 로고    scopus 로고
    • Quantitative image quality evaluation of MR images using perceptual difference models
    • May
    • J. Miao, D. Huo, and D. L. Wilson, "Quantitative image quality evaluation of MR images using perceptual difference models, " Med. Phys., vol.35, pp. 2541-2553, May 2008.
    • (2008) Med. Phys. , vol.35 , pp. 2541-2553
    • Miao, J.1    Huo, D.2    Wilson, D.L.3
  • 27
    • 34047168221 scopus 로고    scopus 로고
    • Adaptive threshold-based block classification in medical image compression for teleradiology
    • Jun.
    • S. Singh, V. Kumar, and H. K. Verma, "Adaptive threshold-based block classification in medical image compression for teleradiology, " Comput. Biol. Med., vol.37, pp. 811-819, Jun. 2007.
    • (2007) Comput. Biol. Med. , vol.37 , pp. 811-819
    • Singh, S.1    Kumar, V.2    Verma, H.K.3
  • 28
    • 33847701378 scopus 로고    scopus 로고
    • Optimization of block size for DCT-based medical image compression
    • Mar.-Apr.
    • S. Singh, V. Kumar, and H. K. Verma, "Optimization of block size for DCT-based medical image compression, " J. Med. Eng. Technol., vol.31, pp. 129-143, Mar.-Apr. 2007.
    • (2007) J. Med. Eng. Technol. , vol.31 , pp. 129-143
    • Singh, S.1    Kumar, V.2    Verma, H.K.3
  • 29
    • 33750369245 scopus 로고    scopus 로고
    • A statistical evaluation of recent full reference image quality assessment algorithms
    • Nov.
    • H. R. Sheikh, M. F. Sabir, and A. C. Bovik, "A statistical evaluation of recent full reference image quality assessment algorithms, " IEEE Trans. Image Process., vol.15, no.11, pp. 3440-3451, Nov. 2006.
    • (2006) IEEE Trans. Image Process. , vol.15 , Issue.11 , pp. 3440-3451
    • Sheikh, H.R.1    Sabir, M.F.2    Bovik, A.C.3
  • 30
    • 48349084865 scopus 로고    scopus 로고
    • Structural similarity quality metrics in a coding context: Exploring the space of realistic distortions
    • Aug.
    • A. C. Brooks, X. Zhao, and T. N. Pappas, "Structural similarity quality metrics in a coding context: Exploring the space of realistic distortions, "IEEE Trans. Image Process., vol.17, no.8, pp. 1261-1273, Aug. 2008.
    • (2008) IEEE Trans. Image Process. , vol.17 , Issue.8 , pp. 1261-1273
    • Brooks, A.C.1    Zhao, X.2    Pappas, T.N.3
  • 31
    • 77955316625 scopus 로고    scopus 로고
    • Digital imaging and communications in medicine (DICOM). Part 14: Gray scale standard display function Nat
    • [Online]. Available Jun. 1. 2009
    • Digital imaging and communications in medicine (DICOM). Part 14: Gray scale standard display function Nat. Electrical Manufacturers Assoc., [Online]. Available: medical.nema.org/dicom/2004/04-14pu. pdf, Jun. 1. 2009
    • Electrical Manufacturers Assoc.
  • 32
    • 4344683331 scopus 로고    scopus 로고
    • Tomographic imaging
    • J. Beutel, H. L. Kundel, and R. L. Van Metter, Eds. Bellingham, WA: SPIE Press
    • D. J. Goodenough, "Tomographic imaging, " in Handbook of Medical Imaging, J. Beutel, H. L. Kundel, and R. L. Van Metter, Eds. Bellingham, WA: SPIE Press, 2000, vol.1, pp. 511-552.
    • (2000) Handbook of Medical Imaging , vol.1 , pp. 511-552
    • Goodenough, D.J.1
  • 33
    • 0041842457 scopus 로고    scopus 로고
    • Irreversible JPEG compres-sionof digital chest radiographs for primary interpretation: Assessment of visually lossless threshold
    • Aug.
    • R. M. Slone, E. Muka, and T. K. Pilgram, "Irreversible JPEG compres-sionof digital chest radiographs for primary interpretation: Assessment of visually lossless threshold, " Radiology, vol.228, pp. 425-429, Aug. 2003.
    • (2003) Radiology , vol.228 , pp. 425-429
    • Slone, R.M.1    Muka, E.2    Pilgram, T.K.3
  • 34
    • 61349156025 scopus 로고    scopus 로고
    • JPEG2000 3D compression vs. 2D compression: An assessment of artifact amount and computing time in compressing thin-section abdomen CT images
    • Mar.
    • B. Kim, K. H. Lee, K. J. Kim, T. Richter, H. S. Kang, S. Y. Kim, Y. H. Kim, and J. Seo, "JPEG2000 3D compression vs. 2D compression: An assessment of artifact amount and computing time in compressing thin-section abdomen CT images, " Med. Phys., vol.36, pp. 835-844, Mar. 2009.
    • (2009) Med. Phys. , vol.36 , pp. 835-844
    • Kim, B.1    Lee, K.H.2    Kim, K.J.3    Richter, T.4    Kang, H.S.5    Kim, S.Y.6    Kim, Y.H.7    Seo, J.8
  • 35
    • 0033997178 scopus 로고    scopus 로고
    • Assessment of visually lossless irreversible image compression: Comparison of three methods by using an image-comparison workstation
    • May
    • R. M. Slone, D. H. Foos, B. R. Whiting, E. Muka, D. A. Rubin, T. K. Pilgram, K. S. Kohm, S. S. Young, P. Ho, and D. D. Hendrickson, "Assessment of visually lossless irreversible image compression: Comparison of three methods by using an image-comparison workstation, " Radiology, vol.215, pp. 543-553, May 2000.
    • (2000) Radiology , vol.215 , pp. 543-553
    • Slone, R.M.1    Foos, D.H.2    Whiting, B.R.3    Muka, E.4    Rubin, D.A.5    Pilgram, T.K.6    Kohm, K.S.7    Young, S.S.8    Ho, P.9    Hendrickson, D.D.10
  • 36
    • 0036721482 scopus 로고    scopus 로고
    • Clinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer
    • Sep.
    • J. M. Lewin, C. J. D'Orsi, R. E. Hendrick, L. J. Moss, P. K. Isaacs, A. Karellas, and G. R. Cutter, "Clinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer, " AJR Am. J. Roentgenol., vol.179, pp. 671-677, Sep. 2002.
    • (2002) AJR Am. J. Roentgenol. , vol.179 , pp. 671-677
    • Lewin, J.M.1    D'Orsi, C.J.2    Hendrick, R.E.3    Moss, L.J.4    Isaacs, P.K.5    Karellas, A.6    Cutter, G.R.7
  • 38
    • 39049166443 scopus 로고    scopus 로고
    • [Online]. Available Jun. 1. 2090
    • HDR Visual Difference Predictor [Online]. Available: http://source-forge. net/projects/hdrvdp OpenSource Technol. Group, Jun. 1. 2009
    • HDR Visual Difference Predictor
  • 39
    • 0003162539 scopus 로고
    • The visible differences predictor: An algorithm for the assessment of image fidelity
    • A. B. Watson, Ed. Cambridge, MA: MIT Press
    • S. Daly, "The visible differences predictor: An algorithm for the assessment of image fidelity, " in Digital Images and Human Vision, A. B. Watson, Ed. Cambridge, MA: MIT Press, 1993, pp. 179-206.
    • (1993) Digital Images and Human Vision , pp. 179-206
    • Daly, S.1
  • 40
    • 85076750845 scopus 로고    scopus 로고
    • A comparison of two image quality models
    • B. Li, G. W. Meyer, and R. V. Klassen, "A comparison of two image quality models, " in Proc. SPIE, 1998, pp. 98-109.
    • (1998) Proc. SPIE , pp. 98-109
    • Li, B.1    Meyer, G.W.2    Klassen, R.V.3
  • 41
    • 0016242648 scopus 로고
    • A vector-magnitude model of contrast detection
    • Jun.
    • R. F. Quick, "A vector-magnitude model of contrast detection, " Biol. Cybern., vol.16, pp. 65-67, Jun. 1974.
    • (1974) Biol. Cybern. , vol.16 , pp. 65-67
    • Quick, R.F.1
  • 42
    • 1942436689 scopus 로고    scopus 로고
    • Image quality assessment: From error visibility to structural similarity
    • Jan.
    • Z. Wang, A. C. Bovik, H. R. Sheikh, and E. P. Simoncelli, "Image quality assessment: From error visibility to structural similarity, " IEEE Trans. Image Process., vol.13, no.1, pp. 600-612, Jan. 2004.
    • (2004) IEEE Trans. Image Process. , vol.13 , Issue.1 , pp. 600-612
    • Wang, Z.1    Bovik, A.C.2    Sheikh, H.R.3    Simoncelli, E.P.4
  • 44
    • 84970216868 scopus 로고
    • The reliability of dichotomous judgements: Unequal numbersof judges per subject
    • J. L. Fleiss and J. Cuzick, "The reliability of dichotomous judgements: Unequal numbersof judges per subject, " Appl. Psychological Measurement, vol.3, pp. 537-542, 1979.
    • (1979) Appl. Psychological Measurement , vol.3 , pp. 537-542
    • Fleiss, J.L.1    Cuzick, J.2
  • 45
    • 0002434611 scopus 로고
    • The use of psychophysical data and models in the analysis of display system performance
    • A. B. Watson, Ed. Cambridge, MA: MIT Press
    • J. Lubin, "The use of psychophysical data and models in the analysis of display system performance, " in Digital Images and Human Vision, A. B. Watson, Ed. Cambridge, MA: MIT Press, 1993, pp. 163-178.
    • (1993) Digital Images and Human Vision , pp. 163-178
    • Lubin, J.1
  • 46
    • 0003196098 scopus 로고
    • DCTune: A technique for visual optimization of DCT quantization matrices for individual images
    • A. B. Watson, "DCTune: A technique for visual optimization of DCT quantization matrices for individual images, " Society for Information Display Digest of Technical Papers, pp. 946-949, 1993.
    • (1993) Society for Information Display Digest of Technical Papers , pp. 946-949
    • Watson, A.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.