메뉴 건너뛰기




Volumn 228, Issue 2, 2003, Pages 425-429

Irreversible JPEG compression of digital chest radiographs for primary interpretation: Assessment of visually lossless threshold

Author keywords

Digital; Digitization; Display; Images; Processing; Quality; Radiography

Indexed keywords

AORTA ANEURYSM; ARTICLE; ATELECTASIS; CARDIOMEGALY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIGITAL RADIOGRAPHY; EMPHYSEMA; HIATUS HERNIA; HUMAN; IMAGE DISPLAY; IMAGE PROCESSING; IMAGE QUALITY; LUNG LOBECTOMY; LUNG NODULE; MASTECTOMY; MEDIASTINUM MASS; PLEURA EFFUSION; PRIORITY JOURNAL; THORAX RADIOGRAPHY; X RAY FILM;

EID: 0041842457     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2282011998     Document Type: Article
Times cited : (35)

References (15)
  • 1
    • 0000413572 scopus 로고
    • Application of noise-adaptive contrast sensitivity function to image data compression
    • Daly S. Application of noise-adaptive contrast sensitivity function to image data compression. Opt Eng 1990; 29:977-987.
    • (1990) Opt Eng , vol.29 , pp. 977-987
    • Daly, S.1
  • 3
    • 0041313333 scopus 로고    scopus 로고
    • Independent JPEG Group home page
    • Independent JPEG Group home page. Available at: www.ijg.org. Accessed June 4, 2003.
  • 5
    • 0025299945 scopus 로고
    • Clinical evaluation of irreversible image compression: Analysis of chest imaging with computed radiography
    • Ishigaki T, Sakuma S, Ikeda M, Itoh Y, Suzuki M, Iwai S. Clinical evaluation of irreversible image compression: analysis of chest imaging with computed radiography. Radiology 1990; 175:739-743.
    • (1990) Radiology , vol.175 , pp. 739-743
    • Ishigaki, T.1    Sakuma, S.2    Ikeda, M.3    Itoh, Y.4    Suzuki, M.5    Iwai, S.6
  • 6
    • 0026007731 scopus 로고
    • Data compression: Effect on diagnostic accuracy in digital chest radiography
    • MacMahon H, Doi K, Sanada S, et al. Data compression: effect on diagnostic accuracy in digital chest radiography. Radiology 1991; 178:175-179.
    • (1991) Radiology , vol.178 , pp. 175-179
    • MacMahon, H.1    Doi, K.2    Sanada, S.3
  • 7
    • 0027849701 scopus 로고
    • The effect of irreversible image compression on diagnostic accuracy in thoracic imaging
    • Aberle DR, Gleeson F, Sayre JW, et al. The effect of irreversible image compression on diagnostic accuracy in thoracic imaging. Invest Radiol 1993; 28:398-403.
    • (1993) Invest Radiol , vol.28 , pp. 398-403
    • Aberle, D.R.1    Gleeson, F.2    Sayre, J.W.3
  • 8
    • 0028737883 scopus 로고
    • Design of a receiver operating characteristic (ROC) study of 10:1 lossy image compression
    • Collins CA, Lane D, Frank M, et al. Design of a receiver operating characteristic (ROC) study of 10:1 lossy image compression. Proc SPIE 1994; 2166:149-158.
    • (1994) Proc SPIE , vol.2166 , pp. 149-158
    • Collins, C.A.1    Lane, D.2    Frank, M.3
  • 9
    • 0027982780 scopus 로고
    • Irreversible data compression in chest imaging using computed radiography: An evaluation
    • Mori T, Nakata H. Irreversible data compression in chest imaging using computed radiography: an evaluation. J Thorac Imaging 1994; 9:23-30.
    • (1994) J Thorac Imaging , vol.9 , pp. 23-30
    • Mori, T.1    Nakata, H.2
  • 10
    • 8944222566 scopus 로고    scopus 로고
    • Detection of subtle interstitial abnormalities of the lungs on digitized chest radiographs: Acceptable data compression ratios
    • Kido S, Ikezoe J, Kondoh H, et al. Detection of subtle interstitial abnormalities of the lungs on digitized chest radiographs: acceptable data compression ratios. AJR Am J Roentgenol 1996; 167:111-115.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 111-115
    • Kido, S.1    Ikezoe, J.2    Kondoh, H.3
  • 11
    • 0030201349 scopus 로고    scopus 로고
    • Clinical evaluation of irreversible data compression for computed radiography in excretory urography
    • Uchida K, Nakamura K, Watanabe H, et al. Clinical evaluation of irreversible data compression for computed radiography in excretory urography. J Digit Imaging 1996; 9:145-149.
    • (1996) J Digit Imaging , vol.9 , pp. 145-149
    • Uchida, K.1    Nakamura, K.2    Watanabe, H.3
  • 12
    • 0032194827 scopus 로고    scopus 로고
    • Perceived fidelity of compressed and reconstructed radiological images: A preliminary exploration of compression, luminance and viewing distance
    • Pilgram TK, Slone RM, Muka E, Cox JR, Blaine GJ. Perceived fidelity of compressed and reconstructed radiological images: a preliminary exploration of compression, luminance and viewing distance. J Digit Imaging 1996; 11:168-175.
    • (1996) J Digit Imaging , vol.11 , pp. 168-175
    • Pilgram, T.K.1    Slone, R.M.2    Muka, E.3    Cox, J.R.4    Blaine, G.J.5
  • 13
    • 0027732378 scopus 로고
    • Presentation of medical images on CRT displays: A renewed proposal for a display function standard
    • Blume H, Daly S, Muka E. Presentation of medical images on CRT displays: a renewed proposal for a display function standard. Proc SPIE 1993; 1897:215-231.
    • (1993) Proc SPIE , vol.1897 , pp. 215-231
    • Blume, H.1    Daly, S.2    Muka, E.3
  • 14
    • 0031339412 scopus 로고    scopus 로고
    • Impact of phosphor luminance noise on the specification of high-resolution CRT displays for medical imaging
    • Muka E, Mertelmeier T, Slone RM, Senol E. Impact of phosphor luminance noise on the specification of high-resolution CRT displays for medical imaging. Proc SPIE 1997; 3031:1-12.
    • (1997) Proc SPIE , vol.3031 , pp. 1-12
    • Muka, E.1    Mertelmeier, T.2    Slone, R.M.3    Senol, E.4
  • 15
    • 0033686807 scopus 로고    scopus 로고
    • JPEG 2000 compression of medical imagery
    • Foos DH, Muka E, Slone RM, et al. JPEG 2000 compression of medical imagery. Proc SPIE 2000; 3980:85-96.
    • (2000) Proc SPIE , vol.3980 , pp. 85-96
    • Foos, D.H.1    Muka, E.2    Slone, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.