Volumn 189, Issue 3, 2007, Pages 535-541

JPEG 2000 compression of abdominal CT: Difference in tolerance between thin- and thick-section images

Author keywords

CT; Data compression; JPEG 2000; Visually lossless threshold

Indexed keywords

ABDOMINAL SCINTISCANNING; ARTICLE; ARTIFACT; COMPRESSION; COMPUTER ASSISTED TOMOGRAPHY; IMAGING; INTERMETHOD COMPARISON; KAPPA STATISTICS; PRIORITY JOURNAL; RADIOLOGIST; SIGNAL NOISE RATIO; STUDENT T TEST;

EID: 34548213118     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.07.2304     Document Type: Article
Times cited : (32)

References (36)
  • 1
    • 24044437885 scopus 로고    scopus 로고
    • Managing the CT data explosion: Initial experiences of archiving volumetric datasets in a mini-PACS
    • Lee KH, Lee HJ, Kim JH, et al. Managing the CT data explosion: initial experiences of archiving volumetric datasets in a mini-PACS. J Digit Imaging 2005; 18:188-195
    • (2005) J Digit Imaging , vol.18 , pp. 188-195
    • Lee, K.H.1    Lee, H.J.2    Kim, J.H.3
  • 2
    • 0034311808 scopus 로고    scopus 로고
    • Data explosion: The challenge of multidetector-row CT
    • Rubin GD. Data explosion: the challenge of multidetector-row CT. Eur J Radiol 2000; 36:74-80
    • (2000) Eur J Radiol , vol.36 , pp. 74-80
    • Rubin, G.D.1
  • 3
    • 0037367904 scopus 로고    scopus 로고
    • 3-D imaging with MDCT
    • Rubin GD. 3-D imaging with MDCT. Eur J Radiol 2003; 45[suppl 1]:S37-S41
    • (2003) Eur J Radiol , vol.45 , Issue.SUPPL. 1
    • Rubin, G.D.1
  • 6
    • 0031882994 scopus 로고    scopus 로고
    • Wavelet compression of medical images
    • Erickson BJ, Manduca A, Palisson P, et al. Wavelet compression of medical images. Radiology 1998; 206:599-607
    • (1998) Radiology , vol.206 , pp. 599-607
    • Erickson, B.J.1    Manduca, A.2    Palisson, P.3
  • 7
    • 0028008897 scopus 로고
    • Thoracic CT images: Effect of lossy image compression on diagnostic accuracy
    • Cosman PC, Davidson HC, Bergin CJ, et al. Thoracic CT images: effect of lossy image compression on diagnostic accuracy. Radiology 1994; 190:517-524
    • (1994) Radiology , vol.190 , pp. 517-524
    • Cosman, P.C.1    Davidson, H.C.2    Bergin, C.J.3
  • 8
    • 0031021235 scopus 로고    scopus 로고
    • Focal hepatic lesions: Effect of three-dimensional wavelet compression on detection at CT
    • Goldberg MA, Gazelle GS, Boland GW, et al. Focal hepatic lesions: effect of three-dimensional wavelet compression on detection at CT. Radiology 1997; 202:159-165
    • (1997) Radiology , vol.202 , pp. 159-165
    • Goldberg, M.A.1    Gazelle, G.S.2    Boland, G.W.3
  • 9
    • 25144519182 scopus 로고    scopus 로고
    • Effect of CT image compression on computer-assisted lung nodule volume measurement
    • Ko JP, Chang J, Bomsztyk E, Babb JS, Naidich DP, Rusinek H. Effect of CT image compression on computer-assisted lung nodule volume measurement. Radiology 2005; 237:83-88
    • (2005) Radiology , vol.237 , pp. 83-88
    • Ko, J.P.1    Chang, J.2    Bomsztyk, E.3    Babb, J.S.4    Naidich, D.P.5    Rusinek, H.6
  • 10
    • 0037700168 scopus 로고    scopus 로고
    • Wavelet compression of low-dose chest CT data: Effect on lung nodule detection
    • Ko JP, Rusinek H, Naidich DP, et al. Wavelet compression of low-dose chest CT data: effect on lung nodule detection. Radiology 2003; 228:70-75
    • (2003) Radiology , vol.228 , pp. 70-75
    • Ko, J.P.1    Rusinek, H.2    Naidich, D.P.3
  • 11
    • 0035263541 scopus 로고    scopus 로고
    • Effects of JPEG and wavelet compression of spiral low-dose CT images on detection of small lung cancers
    • Li F, Sone S, Takashima S, et al. Effects of JPEG and wavelet compression of spiral low-dose CT images on detection of small lung cancers. Acta Radiol 2001; 42:156-160
    • (2001) Acta Radiol , vol.42 , pp. 156-160
    • Li, F.1    Sone, S.2    Takashima, S.3
  • 12
    • 0036616980 scopus 로고    scopus 로고
    • Computed tomography diagnosis utilizing compressed image data: An ROC analysis using acute appendicitis as a model
    • Megibow AJ, Rusinek H, Lisi V, et al. Computed tomography diagnosis utilizing compressed image data: an ROC analysis using acute appendicitis as a model. J Digit Imaging 2002; 15:84-90
    • (2002) J Digit Imaging , vol.15 , pp. 84-90
    • Megibow, A.J.1    Rusinek, H.2    Lisi, V.3
  • 13
    • 0037381406 scopus 로고    scopus 로고
    • Acute cerebral infarction: Effect of JPEG compression on detection at CT
    • Ohgiya Y, Gokan T, Nobusawa H, et al. Acute cerebral infarction: effect of JPEG compression on detection at CT. Radiology 2003; 227:124-127
    • (2003) Radiology , vol.227 , pp. 124-127
    • Ohgiya, Y.1    Gokan, T.2    Nobusawa, H.3
  • 14
    • 0034914234 scopus 로고    scopus 로고
    • CT colonography with teleradiology: Effect of lossy wavelet compression on polyp detection - initial observations
    • Zalis ME, Hahn PF, Arellano RS, Gazelle GS, Mueller PR. CT colonography with teleradiology: effect of lossy wavelet compression on polyp detection - initial observations. Radiology 2001; 220:387-392
    • (2001) Radiology , vol.220 , pp. 387-392
    • Zalis, M.E.1    Hahn, P.F.2    Arellano, R.S.3    Gazelle, G.S.4    Mueller, P.R.5
  • 15
    • 0034146474 scopus 로고    scopus 로고
    • Effect of CT digital image compression on detection of coronary artery calcification
    • Zheng LM, Sone S, Itani Y, et al. Effect of CT digital image compression on detection of coronary artery calcification. Acta Radiol 2000; 41:116-121
    • (2000) Acta Radiol , vol.41 , pp. 116-121
    • Zheng, L.M.1    Sone, S.2    Itani, Y.3
  • 16
    • 0041842457 scopus 로고    scopus 로고
    • Irreversible JPEG compression of digital chest radiographs for primary interpretation: Assessment of visually lossless threshold
    • Slone RM, Muka E, Pilgram TK. Irreversible JPEG compression of digital chest radiographs for primary interpretation: assessment of visually lossless threshold. Radiology 2003; 228:425-429
    • (2003) Radiology , vol.228 , pp. 425-429
    • Slone, R.M.1    Muka, E.2    Pilgram, T.K.3
  • 17
    • 34548292788 scopus 로고    scopus 로고
    • Siddiqui KM, Siegel EL, Reiner BI, Johnson JP, Crave O, Nadar M. Improved image compression at various slice thickness for multi-slice CT using 3D JPEG 2000 (part 2) in comparison with conventional 2D compression. (abstr) Society for Computer Applications in Radiology Scientific Abstracts. Leesburg, VA: Society for Computer Applications in Radiology, 2004:87-88
    • Siddiqui KM, Siegel EL, Reiner BI, Johnson JP, Crave O, Nadar M. Improved image compression at various slice thickness for multi-slice CT using 3D JPEG 2000 (part 2) in comparison with conventional 2D compression. (abstr) Society for Computer Applications in Radiology Scientific Abstracts. Leesburg, VA: Society for Computer Applications in Radiology, 2004:87-88
  • 18
    • 23844514859 scopus 로고    scopus 로고
    • Compression of multislice CT: 2D vs. 3D JPEG2000 and effects of slice thickness
    • Bellingham, WA: SPIE
    • Siegel EL, Siddiqui KM, Johnson JP, et al. Compression of multislice CT: 2D vs. 3D JPEG2000 and effects of slice thickness. SPIE Proceedings. Bellingham, WA: SPIE, 2005:162-170
    • (2005) SPIE Proceedings , pp. 162-170
    • Siegel, E.L.1    Siddiqui, K.M.2    Johnson, J.P.3
  • 20
    • 0033997178 scopus 로고    scopus 로고
    • Assessment of visually lossless irreversible image compression: Comparison of three methods by using an image-comparison workstation
    • Slone RM, Foos DH, Whiting BR, et al. Assessment of visually lossless irreversible image compression: comparison of three methods by using an image-comparison workstation. Radiology 2000; 215:543-553
    • (2000) Radiology , vol.215 , pp. 543-553
    • Slone, R.M.1    Foos, D.H.2    Whiting, B.R.3
  • 21
    • 33747608185 scopus 로고    scopus 로고
    • JPEG2000 compression of thin-section CT images of the lung: Effect of compression ratio on image quality
    • Ringl H, Schernthaner RE, Bankier AA, et al. JPEG2000 compression of thin-section CT images of the lung: effect of compression ratio on image quality. Radiology 2006; 240:869-877
    • (2006) Radiology , vol.240 , pp. 869-877
    • Ringl, H.1    Schernthaner, R.E.2    Bankier, A.A.3
  • 22
    • 0035187964 scopus 로고    scopus 로고
    • Dose and pitch relationship for a particular multislice CT scanner
    • Mahesh M, Scatarige JC, Cooper J, Fishman EK. Dose and pitch relationship for a particular multislice CT scanner. AJR 2001; 177:1273-1275
    • (2001) AJR , vol.177 , pp. 1273-1275
    • Mahesh, M.1    Scatarige, J.C.2    Cooper, J.3    Fishman, E.K.4
  • 23
    • 34548294540 scopus 로고    scopus 로고
    • [No authors listed] Digital imaging and communications in medicine (DICOM). part 14: grayscale standard display function. National Electrical Manufacturers Association standards publication no. PS 3.14-2006. Rosslyn, VA: National Electrical Manufacturers Association, 2004
    • [No authors listed] Digital imaging and communications in medicine (DICOM). part 14: grayscale standard display function. National Electrical Manufacturers Association standards publication no. PS 3.14-2006. Rosslyn, VA: National Electrical Manufacturers Association, 2004
  • 24
    • 84970216868 scopus 로고
    • The reliability of dichotomous judgements: Unequal numbers of judges per subject
    • Fleiss JL, Cuzick J. The reliability of dichotomous judgements: unequal numbers of judges per subject. Appl Psychol Meas 1979; 3:537-542
    • (1979) Appl Psychol Meas , vol.3 , pp. 537-542
    • Fleiss, J.L.1    Cuzick, J.2
  • 25
    • 0020685167 scopus 로고
    • Simplified exact analysis of case-referent studies: Matched pairs; dichotomous exposure
    • Liddell FD. Simplified exact analysis of case-referent studies: matched pairs; dichotomous exposure. J Epidemiol Community Health 1983; 37:82-84
    • (1983) J Epidemiol Community Health , vol.37 , pp. 82-84
    • Liddell, F.D.1
  • 26
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977; 33:159-174
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 27
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Topics in CT - radiation dose in CT
    • McNitt-Gray MF. AAPM/RSNA physics tutorial for residents: topics in CT - radiation dose in CT. RadioGraphics 2002; 22:1541-1553
    • (2002) RadioGraphics , vol.22 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 28
    • 0032015058 scopus 로고    scopus 로고
    • Introduction to wavelet-based compression of medical images
    • Schomer DF, Elekes AA, Hazle JD, et al. Introduction to wavelet-based compression of medical images. RadioGraphics 1998; 18:469-481
    • (1998) RadioGraphics , vol.18 , pp. 469-481
    • Schomer, D.F.1    Elekes, A.A.2    Hazle, J.D.3
  • 29
    • 28144451372 scopus 로고    scopus 로고
    • Informatics in radiology (infoRAD): Introduction to the language of three-dimensional imaging with multidetector CT
    • Dalrymple NC, Prasad SR, Freckleton MW, Chintapalli KN. Informatics in radiology (infoRAD): introduction to the language of three-dimensional imaging with multidetector CT. RadioGraphics 2005; 25:1409-1428
    • (2005) RadioGraphics , vol.25 , pp. 1409-1428
    • Dalrymple, N.C.1    Prasad, S.R.2    Freckleton, M.W.3    Chintapalli, K.N.4
  • 30
    • 33747827820 scopus 로고    scopus 로고
    • Computed tomography diagnosis of acuteappendicitis: Advantages of reviewing thin-section datasets using sliding slab average intensity projection technique
    • Lee KH, Kim YH, Hahn S, et al. Computed tomography diagnosis of acuteappendicitis: advantages of reviewing thin-section datasets using sliding slab average intensity projection technique. Invest Radiol 2006; 41:579-585
    • (2006) Invest Radiol , vol.41 , pp. 579-585
    • Lee, K.H.1    Kim, Y.H.2    Hahn, S.3
  • 31
    • 0035702703 scopus 로고    scopus 로고
    • Evaluation of compressed lung CT image quality using quantitative analysis
    • Yamamoto S, Johkoh T, Mihara N, et al. Evaluation of compressed lung CT image quality using quantitative analysis. Radial Med 2001; 19:321-329
    • (2001) Radial Med , vol.19 , pp. 321-329
    • Yamamoto, S.1    Johkoh, T.2    Mihara, N.3
  • 32
    • 0002434611 scopus 로고
    • The use of psychophysical data and models in the analysis of display system performance
    • Watson AB, ed, Cambridge, MA: MIT Press
    • Lubin J. The use of psychophysical data and models in the analysis of display system performance. In: Watson AB, ed. Digital images and human vision. Cambridge, MA: MIT Press, 1993:163-178
    • (1993) Digital images and human vision , pp. 163-178
    • Lubin, J.1
  • 33
    • 34248652953 scopus 로고    scopus 로고
    • Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: Assessment of visually lossless threshold
    • Lee KH, Kim YH, Kim BH, et al. Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold. Eur Radiol 2007; 17:1529-1534
    • (2007) Eur Radiol , vol.17 , pp. 1529-1534
    • Lee, K.H.1    Kim, Y.H.2    Kim, B.H.3
  • 34
    • 0031379679 scopus 로고    scopus 로고
    • Factors affecting the selection of compression algorithms for projection radiography
    • Bellingham, WA: SPIE
    • Cox JE, Muka E. Factors affecting the selection of compression algorithms for projection radiography. SPIE Proceedings. Bellingham, WA: SPIE, 1997:256-264
    • (1997) SPIE Proceedings , pp. 256-264
    • Cox, J.E.1    Muka, E.2
  • 35
    • 0032194827 scopus 로고    scopus 로고
    • Perceived fidelity of compressed and reconstructed radiological images: A preliminary exploration of compression, luminance, and viewing distance
    • Pilgram TK, Slone RM, Muka E, Cox JR, Blaine GJ. Perceived fidelity of compressed and reconstructed radiological images: a preliminary exploration of compression, luminance, and viewing distance. J Digit Imaging 1998; 11:168-175
    • (1998) J Digit Imaging , vol.11 , pp. 168-175
    • Pilgram, T.K.1    Slone, R.M.2    Muka, E.3    Cox, J.R.4    Blaine, G.J.5
  • 36
    • 34548250796 scopus 로고    scopus 로고
    • Bak PRG. Does irreversible compression impact the diagnostic quality of medical images? A review of research to date. (abstr) Society for Computer Applications in Radiology Scientific Abstracts. Leesburg, VA: Society for Computer Applications in Radiology, 2005:22-24
    • Bak PRG. Does irreversible compression impact the diagnostic quality of medical images? A review of research to date. (abstr) Society for Computer Applications in Radiology Scientific Abstracts. Leesburg, VA: Society for Computer Applications in Radiology, 2005:22-24


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.