메뉴 건너뛰기




Volumn 36, Issue 3, 2009, Pages 835-844

JPEG2000 3D compression vs 2D compression: An assessment of artifact amount and computing time in compressing thin-section abdomen CT images

Author keywords

Abdomen CT; Compression; JPEG2000 3D (part 2); Thin sections; Visual analysis; Visually lossless threshold

Indexed keywords

COMPACTION; COMPUTERIZED TOMOGRAPHY; DATA COMPRESSION RATIO; SIGNAL TO NOISE RATIO;

EID: 61349156025     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3075824     Document Type: Article
Times cited : (17)

References (41)
  • 1
    • 24044437885 scopus 로고    scopus 로고
    • Managing the CT data explosion: Initial experiences of archiving volumetric datasets in a mini-PACS
    • 0897-1889
    • K. H. Lee, H. J. Lee, J. H. Kim, H. S. Kang, K. W. Lee, H. Hong, H. J. Chin, and K. S. Ha, " Managing the CT data explosion: Initial experiences of archiving volumetric datasets in a mini-PACS.," J. Digit Imaging 18, 188-195 (2005). 0897-1889
    • (2005) J. Digit Imaging , vol.18 , pp. 188-195
    • Lee, K.H.1    Lee, H.J.2    Kim, J.H.3    Kang, H.S.4    Lee, K.W.5    Hong, H.6    Chin, H.J.7    Ha, K.S.8
  • 2
    • 33747608185 scopus 로고    scopus 로고
    • JPEG2000 compression of thin-section CT images of the lung: Effect of compression ratio on image quality
    • 0033-8419 10.1148/radiol.2403050519.
    • H. Ringl, R. E. Schernthaner, A. A. Bankier, M. Weber, M. Prokop, C. J. Herold, and C. Schaefer-Prokop, " JPEG2000 compression of thin-section CT images of the lung: Effect of compression ratio on image quality.," Radiology 0033-8419 10.1148/radiol.2403050519 240, 869-877 (2006).
    • (2006) Radiology , vol.240 , pp. 869-877
    • Ringl, H.1    Schernthaner, R.E.2    Bankier, A.A.3    Weber, M.4    Prokop, M.5    Herold, C.J.6    Schaefer-Prokop, C.7
  • 3
    • 35349013622 scopus 로고    scopus 로고
    • Lossy three-dimensional JPEG2000 compression of abdominal CT images: Assessment of the visually lossless threshold and effect of compression ratio on image quality
    • 0033-8419
    • H. Ringl, R. E. Schernthaner, C. Kulinna-Cosentini, M. Weber, C. Schaefer-Prokop, C. J. Herold, and W. Schima, " Lossy three-dimensional JPEG2000 compression of abdominal CT images: Assessment of the visually lossless threshold and effect of compression ratio on image quality.," Radiology 245, 467-474 (2007). 0033-8419
    • (2007) Radiology , vol.245 , pp. 467-474
    • Ringl, H.1    Schernthaner, R.E.2    Kulinna-Cosentini, C.3    Weber, M.4    Schaefer-Prokop, C.5    Herold, C.J.6    Schima, W.7
  • 4
    • 34548213118 scopus 로고    scopus 로고
    • JPEG 2000 compression of abdominal CT: Difference in compression tolerance between thin-and thick-section images
    • 0361-803X 10.2214/AJR.07.2304.
    • H. S. Woo, K. J. Kim, T. J. Kim, S. Hahn, B. H. Kim, Y. H. Kim, C. J. Yoon, and K. H. Lee, " JPEG 2000 compression of abdominal CT: Difference in compression tolerance between thin-and thick-section images.," AJR, Am. J. Roentgenol. 0361-803X 10.2214/AJR.07.2304 189, 535-541 (2007).
    • (2007) AJR, Am. J. Roentgenol. , vol.189 , pp. 535-541
    • Woo, H.S.1    Kim, K.J.2    Kim, T.J.3    Hahn, S.4    Kim, B.H.5    Kim, Y.H.6    Yoon, C.J.7    Lee, K.H.8
  • 5
    • 39049132947 scopus 로고    scopus 로고
    • Prediction of perceptible artifacts in JPEG2000 compressed abdomen CT images using a perceptual image quality metric
    • 1076-6332
    • B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, V. Bajpai, T. J. Kim, Y. H. Kim, C. J. Yoon, and S. Hahn, " Prediction of perceptible artifacts in JPEG2000 compressed abdomen CT images using a perceptual image quality metric.," Acad. Radiol. 15, 314-325 (2008). 1076-6332
    • (2008) Acad. Radiol. , vol.15 , pp. 314-325
    • Kim, B.1    Lee, K.H.2    Kim, K.J.3    Mantiuk, R.4    Bajpai, V.5    Kim, T.J.6    Kim, Y.H.7    Yoon, C.J.8    Hahn, S.9
  • 6
    • 44949237872 scopus 로고    scopus 로고
    • Artifacts in slab average-intensity-projection images reformatted from JPEG 2000 compressed thin-section abdominal CT data sets
    • 0361-803X
    • B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, H. Kim, and Y. H. Kim, " Artifacts in slab average-intensity-projection images reformatted from JPEG 2000 compressed thin-section abdominal CT data sets.," AJR, Am. J. Roentgenol. 190, W342-W350 (2008). 0361-803X
    • (2008) AJR, Am. J. Roentgenol. , vol.190
    • Kim, B.1    Lee, K.H.2    Kim, K.J.3    Mantiuk, R.4    Kim, H.5    Kim, Y.H.6
  • 8
    • 49049115376 scopus 로고    scopus 로고
    • Lossy 3D JPEG2000 compression of abdominal CT images in patients with acute abdominal complaints: Effect of compression ratio on diagnostic confidence and accuracy
    • 0033-8419
    • H. Ringl, R. Schernthaner, E. Sala, K. El-Rabadi, M. Weber, W. Schima, C. J. Herold, and A. K. Dixon, " Lossy 3D JPEG2000 compression of abdominal CT images in patients with acute abdominal complaints: Effect of compression ratio on diagnostic confidence and accuracy.," Radiology 248, 476-484 (2008). 0033-8419
    • (2008) Radiology , vol.248 , pp. 476-484
    • Ringl, H.1    Schernthaner, R.2    Sala, E.3    El-Rabadi, K.4    Weber, M.5    Schima, W.6    Herold, C.J.7    Dixon, A.K.8
  • 14
    • 85027237428 scopus 로고    scopus 로고
    • Digital Imaging and Communications in Medicine (DICOM) Supplement 105: JPEG 2000 part 2 multi-component transfer syntaxes.
    • Digital Imaging and Communications in Medicine (DICOM) Supplement 105: JPEG 2000 part 2 multi-component transfer syntaxes, ftp://medical.nema.org/ medical/dicom/final/sup105-ft.doc.
  • 15
    • 85027231647 scopus 로고    scopus 로고
    • ACCURAD J2K-3D.
    • ACCURAD J2K-3D, http://www.aware.com/imaging/accuradj2k3d.htm.
  • 16
    • 85027227979 scopus 로고    scopus 로고
    • PICTools Advanced Compression Technology SDK.
    • PICTools Advanced Compression Technology SDK, http://www.pegasusimaging. com/pictools.htm.
  • 19
    • 34248652953 scopus 로고    scopus 로고
    • K. H.J. and S. Hahn, "irreversible JPEG 2000 compression of abdominal CT for primary interpretation: Assessment of visually lossless threshold
    • 0938-7994
    • K. H. Lee, Y. H. Kim, B. H. Kim, K. J. Kim, and T. J. Kim, " K. H.J. and S. Hahn, "Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: Assessment of visually lossless threshold.," Eur. Radiol. 17, 1529-1534 (2007). 0938-7994
    • (2007) Eur. Radiol. , vol.17 , pp. 1529-1534
    • Lee, K.H.1    Kim, Y.H.2    Kim, B.H.3    Kim, K.J.4    Kim, T.J.5
  • 21
    • 85027227631 scopus 로고    scopus 로고
    • Final report from the video quality experts grouon the validation of objective models of video quality assessment.
    • Final report from the video quality experts group on the validation of objective models of video quality assessment, http://www.its.bldrdoc.gov/vqeg/ projects/frtv-phaseI/COM-80E-final-report.pdf.
  • 22
    • 0032202314 scopus 로고    scopus 로고
    • Perceptual quality metrics applied to still image compression
    • 0165-1684
    • M. P. Eckert and A. P. Bradley, " Perceptual quality metrics applied to still image compression.," Signal Processing 70, 177-200 (1998). 0165-1684
    • (1998) Signal Processing , vol.70 , pp. 177-200
    • Eckert, M.P.1    Bradley, A.P.2
  • 23
    • 38849112717 scopus 로고    scopus 로고
    • Prediction of perceptible artifacts in JPEG2000-compressed chest CT images using mathematical and perceptual quality metrics
    • 0361-803X
    • B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, S. Hahn, T. J. Kim, and Y. H. Kim, " Prediction of perceptible artifacts in JPEG2000-compressed chest CT images using mathematical and perceptual quality metrics.," AJR, Am. J. Roentgenol. 190, 328-334 (2008). 0361-803X
    • (2008) AJR, Am. J. Roentgenol. , vol.190 , pp. 328-334
    • Kim, B.1    Lee, K.H.2    Kim, K.J.3    Mantiuk, R.4    Hahn, S.5    Kim, T.J.6    Kim, Y.H.7
  • 24
    • 85027238656 scopus 로고    scopus 로고
    • Final report from the video quality experts grouon the validation of objective models of video quality assessment, phase II.
    • Final report from the video quality experts group on the validation of objective models of video quality assessment, phase II, http://www.its.bldrdoc. gov/vqeg/projects/frtv-phaseII/downloads/VQEGII-Final-Report.pdf.
  • 25
    • 85027240293 scopus 로고    scopus 로고
    • Digital Imaging and Communications in Medicine (DICOM), Part 14: Gray scale standard display function, NEMA Standards Publication So, PS 3.14-2006.
    • Digital Imaging and Communications in Medicine (DICOM), Part 14: Gray scale standard display function, NEMA Standards Publication So, PS 3.14-2006, http://www.nema.org/stds/ps3-1.cfm.
  • 26
    • 49749090898 scopus 로고
    • in, edited by G. Wolberg (Wiley-IEEE Computer Society, Los Alamitos, CA)
    • G. Wolberg, in Digital image warping, edited by, G. Wolberg, (Wiley-IEEE Computer Society, Los Alamitos, CA, 1990), pp. 117-161.
    • (1990) Digital Image Warping , pp. 117-161
    • Wolberg, G.1
  • 27
    • 38849146997 scopus 로고    scopus 로고
    • Anniversary paper: Evaluation of medical imaging systems
    • 0094-2405 10.1118/1.2830376.
    • E. A. Krupinski, " Anniversary paper: evaluation of medical imaging systems.," Med. Phys. 0094-2405 10.1118/1.2830376 35, 645-659 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 645-659
    • Krupinski, E.A.1
  • 28
    • 0033997178 scopus 로고    scopus 로고
    • Assessment of visually lossless irreversible image compression: Comparison of three methods by using an image-comparison workstation
    • 0033-8419
    • R. M. Slone, D. H. Foos, B. R. Whiting, E. Muka, D. A. Rubin, T. K. Pilgram, K. S. Kohm, S. S. Young, P. Ho, and D. D. Hendrickson, " Assessment of visually lossless irreversible image compression: Comparison of three methods by using an image-comparison workstation.," Radiology 215, 543-553 (2000). 0033-8419
    • (2000) Radiology , vol.215 , pp. 543-553
    • Slone, R.M.1    Foos, D.H.2    Whiting, B.R.3    Muka, E.4    Rubin, D.A.5    Pilgram, T.K.6    Kohm, K.S.7    Young, S.S.8    Ho, P.9    Hendrickson, D.D.10
  • 29
    • 0041842457 scopus 로고    scopus 로고
    • Irreversible JPEG compression of digital chest radiographs for primary interpretation: Assessment of visually lossless threshold
    • 0033-8419 10.1148/radiol.2282011998.
    • R. M. Slone, E. Muka, and T. K. Pilgram, " Irreversible JPEG compression of digital chest radiographs for primary interpretation: Assessment of visually lossless threshold.," Radiology 0033-8419 10.1148/radiol. 2282011998 228, 425-429 (2003).
    • (2003) Radiology , vol.228 , pp. 425-429
    • Slone, R.M.1    Muka, E.2    Pilgram, T.K.3
  • 30
    • 44949203917 scopus 로고    scopus 로고
    • Regional variance of visually lossless threshold in compressed chest CT Images: Lung versus mediastinum and chest Wall
    • 0720-048X
    • T. J. Kim, K. W. Lee, B. Kim, K. J. Kim, E. J. Chun, V. Bajpai, Y. H. Kim, S. Hahn, and K. H. Lee, " Regional variance of visually lossless threshold in compressed chest CT Images: Lung versus mediastinum and chest Wall.," Eur. J. Radiol. (2008). 0720-048X
    • (2008) Eur. J. Radiol.
    • Kim, T.J.1    Lee, K.W.2    Kim, B.3    Kim, K.J.4    Chun, E.J.5    Bajpai, V.6    Kim, Y.H.7    Hahn, S.8    Lee, K.H.9
  • 31
    • 49149120343 scopus 로고    scopus 로고
    • Regional difference in compression artifacts in low-dose chest CT images: Effects of mathematical and perceptual factors
    • 0361-803X
    • K. J. Kim, B. Kim, K. H. Lee, T. J. Kim, R. Mantiuk, H. S. Kang, and Y. H. Kim, " Regional difference in compression artifacts in low-dose chest CT images: Effects of mathematical and perceptual factors.," AJR, Am. J. Roentgenol. 191, W30-W37 (2008). 0361-803X
    • (2008) AJR, Am. J. Roentgenol. , vol.191
    • Kim, K.J.1    Kim, B.2    Lee, K.H.3    Kim, T.J.4    Mantiuk, R.5    Kang, H.S.6    Kim, Y.H.7
  • 33
    • 0020685167 scopus 로고
    • Simplified exact analysis of case-referent studies: Matched pairs; Dichotomous exposure
    • 0141-7681
    • F. D. Liddell, " Simplified exact analysis of case-referent studies: Matched pairs; dichotomous exposure.," J. Epidemiol. Community Health 37, 82-84 (1983). 0141-7681
    • (1983) J. Epidemiol. Community Health , vol.37 , pp. 82-84
    • Liddell, F.D.1
  • 34
    • 58149409073 scopus 로고
    • Large sample variance of kappa in the case of different sets of raters
    • 0033-2909
    • J. L. Fleiss, C. M. Nee, and J. R. Landis, " Large sample variance of kappa in the case of different sets of raters.," Psychol. Bull. 86, 974-977 (1979). 0033-2909
    • (1979) Psychol. Bull. , vol.86 , pp. 974-977
    • Fleiss, J.L.1    Nee, C.M.2    Landis, J.R.3
  • 35
    • 0346910249 scopus 로고    scopus 로고
    • Perceptual blur and ringing metrics: Application to JPEG2000
    • 0923-5965 10.1016/j.image.2003.08.003.
    • P. Marziliano, F. Dufaux, S. Winkler, and T. Ebrahimi, " Perceptual blur and ringing metrics: Application to JPEG2000.," Signal Process. Image Commun. 0923-5965 10.1016/j.image.2003.08.003 19, 163-172 (2004).
    • (2004) Signal Process. Image Commun. , vol.19 , pp. 163-172
    • Marziliano, P.1    Dufaux, F.2    Winkler, S.3    Ebrahimi, T.4
  • 36
    • 33746601318 scopus 로고    scopus 로고
    • The impact of image information on compressibility and degradation in medical image compression
    • 0094-2405 10.1118/1.2218316.
    • A. Fidler and U. Skaleric, " The impact of image information on compressibility and degradation in medical image compression.," Med. Phys. 0094-2405 10.1118/1.2218316 33, 2832-2838 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 2832-2838
    • Fidler, A.1    Skaleric, U.2
  • 38
    • 0141719771 scopus 로고    scopus 로고
    • Comparing subjective video quality testing methodologies
    • 0277-786X
    • M. Pinson and S. Wolf, " Comparing subjective video quality testing methodologies.," Proc. SPIE 5150, 572-582 (2003). 0277-786X
    • (2003) Proc. SPIE , vol.5150 , pp. 572-582
    • Pinson, M.1    Wolf, S.2
  • 40
    • 0033354138 scopus 로고    scopus 로고
    • Time-varying image quality: Modeling the relation between instantaneous and overall quality
    • R. Hamberg and H. Ridder, " Time-varying image quality: modeling the relation between instantaneous and overall quality.," SMPTE J. 108, 802-811 (1999).
    • (1999) SMPTE J. , vol.108 , pp. 802-811
    • Hamberg, R.1    Ridder, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.