메뉴 건너뛰기




Volumn 15, Issue 3, 2008, Pages 314-325

Prediction of Perceptible Artifacts in JPEG2000 Compressed Abdomen CT Images Using a Perceptual Image Quality Metric

Author keywords

Abdomen CT; compression; human visual system; image quality metric

Indexed keywords

ACCURACY; ADULT; AGED; AREA UNDER THE CURVE; ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; MCNEMAR TEST; PREDICTION; PRIORITY JOURNAL; RADIOLOGIST; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; SIGNAL NOISE RATIO; STUDENT T TEST; VISUAL THRESHOLD;

EID: 39049132947     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2007.10.018     Document Type: Article
Times cited : (20)

References (46)
  • 1
    • 0031882994 scopus 로고    scopus 로고
    • Wavelet compression of medical images
    • Erickson B.J., Manduca A., Palisson P., et al. Wavelet compression of medical images. Radiology 206 (1998) 599-607
    • (1998) Radiology , vol.206 , pp. 599-607
    • Erickson, B.J.1    Manduca, A.2    Palisson, P.3
  • 2
    • 0032015058 scopus 로고    scopus 로고
    • Introduction to wavelet-based compression of medical images
    • Schomer D.F., Elekes A.A., Hazle J.D., et al. Introduction to wavelet-based compression of medical images. Radiographics 18 (1998) 469-481
    • (1998) Radiographics , vol.18 , pp. 469-481
    • Schomer, D.F.1    Elekes, A.A.2    Hazle, J.D.3
  • 4
    • 24044437885 scopus 로고    scopus 로고
    • Managing the CT data explosion: initial experiences of archiving volumetric datasets in a mini-PACS
    • Lee K.H., Lee H.J., Kim J.H., et al. Managing the CT data explosion: initial experiences of archiving volumetric datasets in a mini-PACS. J Digit Imaging 18 (2005) 188-195
    • (2005) J Digit Imaging , vol.18 , pp. 188-195
    • Lee, K.H.1    Lee, H.J.2    Kim, J.H.3
  • 5
    • 0034311808 scopus 로고    scopus 로고
    • Data explosion: the challenge of multidetector-row CT
    • Rubin G.D. Data explosion: the challenge of multidetector-row CT. Eur J Radiol 36 (2000) 74-80
    • (2000) Eur J Radiol , vol.36 , pp. 74-80
    • Rubin, G.D.1
  • 7
    • 0028008897 scopus 로고
    • Thoracic CT images: effect of lossy image compression on diagnostic accuracy
    • Cosman P.C., Davidson H.C., Bergin C.J., et al. Thoracic CT images: effect of lossy image compression on diagnostic accuracy. Radiology 190 (1994) 517-524
    • (1994) Radiology , vol.190 , pp. 517-524
    • Cosman, P.C.1    Davidson, H.C.2    Bergin, C.J.3
  • 8
    • 0031021235 scopus 로고    scopus 로고
    • Focal hepatic lesions: effect of three-dimensional wavelet compression on detection at CT
    • Goldberg M.A., Gazelle G.S., Boland G.W., et al. Focal hepatic lesions: effect of three-dimensional wavelet compression on detection at CT. Radiology 202 (1997) 159-165
    • (1997) Radiology , vol.202 , pp. 159-165
    • Goldberg, M.A.1    Gazelle, G.S.2    Boland, G.W.3
  • 9
    • 25144519182 scopus 로고    scopus 로고
    • Effect of CT image compression on computer-assisted lung nodule volume measurement
    • Ko J.P., Chang J., Bomsztyk E., et al. Effect of CT image compression on computer-assisted lung nodule volume measurement. Radiology 237 (2005) 83-88
    • (2005) Radiology , vol.237 , pp. 83-88
    • Ko, J.P.1    Chang, J.2    Bomsztyk, E.3
  • 10
    • 0037700168 scopus 로고    scopus 로고
    • Wavelet compression of low-dose chest CT data: effect on lung nodule detection
    • Ko J.P., Rusinek H., Naidich D.P., et al. Wavelet compression of low-dose chest CT data: effect on lung nodule detection. Radiology 228 (2003) 70-75
    • (2003) Radiology , vol.228 , pp. 70-75
    • Ko, J.P.1    Rusinek, H.2    Naidich, D.P.3
  • 11
    • 0035263541 scopus 로고    scopus 로고
    • Effects of JPEG and wavelet compression of spiral low-dose CT images on detection of small lung cancers
    • Li F., Sone S., Takashima S., et al. Effects of JPEG and wavelet compression of spiral low-dose CT images on detection of small lung cancers. Acta Radiol 42 (2001) 156-160
    • (2001) Acta Radiol , vol.42 , pp. 156-160
    • Li, F.1    Sone, S.2    Takashima, S.3
  • 12
    • 0036616980 scopus 로고    scopus 로고
    • Computed tomography diagnosis utilizing compressed image data: an ROC analysis using acute appendicitis as a model
    • Megibow A.J., Rusinek H., Lisi V., et al. Computed tomography diagnosis utilizing compressed image data: an ROC analysis using acute appendicitis as a model. J Digit Imaging 15 (2002) 84-90
    • (2002) J Digit Imaging , vol.15 , pp. 84-90
    • Megibow, A.J.1    Rusinek, H.2    Lisi, V.3
  • 13
    • 0037381406 scopus 로고    scopus 로고
    • Acute cerebral infarction: effect of JPEG compression on detection at CT
    • Ohgiya Y., Gokan T., Nobusawa H., et al. Acute cerebral infarction: effect of JPEG compression on detection at CT. Radiology 227 (2003) 124-127
    • (2003) Radiology , vol.227 , pp. 124-127
    • Ohgiya, Y.1    Gokan, T.2    Nobusawa, H.3
  • 14
    • 0034914234 scopus 로고    scopus 로고
    • CT colonography with teleradiology: effect of lossy wavelet compression on polyp detection-initial observations
    • Zalis M.E., Hahn P.F., Arellano R.S., et al. CT colonography with teleradiology: effect of lossy wavelet compression on polyp detection-initial observations. Radiology 220 (2001) 387-392
    • (2001) Radiology , vol.220 , pp. 387-392
    • Zalis, M.E.1    Hahn, P.F.2    Arellano, R.S.3
  • 15
    • 0034146474 scopus 로고    scopus 로고
    • Effect of CT digital image compression on detection of coronary artery calcification
    • Zheng L.M., Sone S., Itani Y., et al. Effect of CT digital image compression on detection of coronary artery calcification. Acta Radiol 41 (2000) 116-121
    • (2000) Acta Radiol , vol.41 , pp. 116-121
    • Zheng, L.M.1    Sone, S.2    Itani, Y.3
  • 16
    • 39049086103 scopus 로고    scopus 로고
    • Kim TJ, Lee KW, Kim B, et al. Regional variance of visually lossless threshold in compressed chest CT Images: lung versus mediastinum and chest Wall. Eur J Radiol. In press.
    • Kim TJ, Lee KW, Kim B, et al. Regional variance of visually lossless threshold in compressed chest CT Images: lung versus mediastinum and chest Wall. Eur J Radiol. In press.
  • 17
    • 34548213118 scopus 로고    scopus 로고
    • JPEG 2000 compression of abdominal CT: difference in compression tolerance between thin- and thick-section images
    • Woo H.S., Kim K.J., Kim T.J., et al. JPEG 2000 compression of abdominal CT: difference in compression tolerance between thin- and thick-section images. Am J Roentgenol 189 (2007) 535-541
    • (2007) Am J Roentgenol , vol.189 , pp. 535-541
    • Woo, H.S.1    Kim, K.J.2    Kim, T.J.3
  • 18
    • 0033997178 scopus 로고    scopus 로고
    • Assessment of visually lossless irreversible image compression: comparison of three methods by using an image-comparison workstation
    • Slone R.M., Foos D.H., Whiting B.R., et al. Assessment of visually lossless irreversible image compression: comparison of three methods by using an image-comparison workstation. Radiology 215 (2000) 543-553
    • (2000) Radiology , vol.215 , pp. 543-553
    • Slone, R.M.1    Foos, D.H.2    Whiting, B.R.3
  • 19
    • 33747608185 scopus 로고    scopus 로고
    • JPEG2000 compression of thin-section CT images of the lung: effect of compression ratio on image quality
    • Ringl H., Schernthaner R.E., Bankier A.A., et al. JPEG2000 compression of thin-section CT images of the lung: effect of compression ratio on image quality. Radiology 240 (2006) 869-877
    • (2006) Radiology , vol.240 , pp. 869-877
    • Ringl, H.1    Schernthaner, R.E.2    Bankier, A.A.3
  • 20
    • 0041842457 scopus 로고    scopus 로고
    • Irreversible JPEG compression of digital chest radiographs for primary interpretation: assessment of visually lossless threshold
    • Slone R.M., Muka E., and Pilgram T.K. Irreversible JPEG compression of digital chest radiographs for primary interpretation: assessment of visually lossless threshold. Radiology 228 (2003) 425-429
    • (2003) Radiology , vol.228 , pp. 425-429
    • Slone, R.M.1    Muka, E.2    Pilgram, T.K.3
  • 21
    • 34248652953 scopus 로고    scopus 로고
    • Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold
    • Lee K.H., Kim Y.H., Kim B.H., et al. Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold. Eur Radiol 17 (2007) 1529-1534
    • (2007) Eur Radiol , vol.17 , pp. 1529-1534
    • Lee, K.H.1    Kim, Y.H.2    Kim, B.H.3
  • 22
    • 39049111396 scopus 로고    scopus 로고
    • Kim B, Lee KH, Kim KJ, et al. Prediction of perceptible artifacts in JPEG2000 compressed chest CT images using mathematical and perceptual quality metrics. Am J Roentgenol. In press.
    • Kim B, Lee KH, Kim KJ, et al. Prediction of perceptible artifacts in JPEG2000 compressed chest CT images using mathematical and perceptual quality metrics. Am J Roentgenol. In press.
  • 23
    • 33847206055 scopus 로고    scopus 로고
    • Choosing a radiology workstation: technical and clinical considerations
    • Krupinski E.A., and Kallergi M. Choosing a radiology workstation: technical and clinical considerations. Radiology 242 (2007) 671-682
    • (2007) Radiology , vol.242 , pp. 671-682
    • Krupinski, E.A.1    Kallergi, M.2
  • 25
    • 0035187964 scopus 로고    scopus 로고
    • Dose and pitch relationship for a particular multislice CT scanner
    • Mahesh M., Scatarige J.C., Cooper J., et al. Dose and pitch relationship for a particular multislice CT scanner. Am J Roentgenol 177 (2001) 1273-1275
    • (2001) Am J Roentgenol , vol.177 , pp. 1273-1275
    • Mahesh, M.1    Scatarige, J.C.2    Cooper, J.3
  • 26
    • 39049095578 scopus 로고    scopus 로고
    • Kim KJ, Kim B, Choi SW, et al. Definition of compression ratio: difference between two commercial JPEG2000 program libraries. Telemed J E Health. In press.
    • Kim KJ, Kim B, Choi SW, et al. Definition of compression ratio: difference between two commercial JPEG2000 program libraries. Telemed J E Health. In press.
  • 29
    • 0016242648 scopus 로고
    • A vector magnitude model of contrast detection
    • Quick R.F. A vector magnitude model of contrast detection. Kybernetik 16 (1974) 65-67
    • (1974) Kybernetik , vol.16 , pp. 65-67
    • Quick, R.F.1
  • 30
    • 0032202314 scopus 로고    scopus 로고
    • Perceptual quality metrics applied to still image compression
    • Eckert M.P., and Bradley A.P. Perceptual quality metrics applied to still image compression. Signal Processing 70 (1998) 177-200
    • (1998) Signal Processing , vol.70 , pp. 177-200
    • Eckert, M.P.1    Bradley, A.P.2
  • 31
    • 84970216868 scopus 로고
    • The reliability of dichotomous judgements: unequal numbers of judges per subject
    • Fleiss J.L., and Cuzick J. The reliability of dichotomous judgements: unequal numbers of judges per subject. Appl Psychol Measurement 3 (1979) 537-542
    • (1979) Appl Psychol Measurement , vol.3 , pp. 537-542
    • Fleiss, J.L.1    Cuzick, J.2
  • 32
    • 0031195511 scopus 로고    scopus 로고
    • An analytical look at the effects of compression on medical images
    • Persons K., Palisson P., Manduca A., et al. An analytical look at the effects of compression on medical images. J Digit Imaging 10 (1997) 60-66
    • (1997) J Digit Imaging , vol.10 , pp. 60-66
    • Persons, K.1    Palisson, P.2    Manduca, A.3
  • 33
    • 0003162539 scopus 로고
    • The visible differences predictor: an algorithm for the assessment of image fidelity
    • Watson A.B. (Ed), MIT Press, Cambridge, MA
    • Daly S. The visible differences predictor: an algorithm for the assessment of image fidelity. In: Watson A.B. (Ed). Digital images and human vision (1993), MIT Press, Cambridge, MA 179-206
    • (1993) Digital images and human vision , pp. 179-206
    • Daly, S.1
  • 34
    • 0002434611 scopus 로고
    • The use of psychophysical data and models in the analysis of display system performance
    • Watson A.B. (Ed), MIT Press, Cambridge, MA
    • Lubin J. The use of psychophysical data and models in the analysis of display system performance. In: Watson A.B. (Ed). Digital images and human vision (1993), MIT Press, Cambridge, MA 163-178
    • (1993) Digital images and human vision , pp. 163-178
    • Lubin, J.1
  • 35
    • 23844501793 scopus 로고    scopus 로고
    • Correlation of radiologists' image quality perception with quantitative assessment parameters: just-noticeable difference vs. peak signal-to-noise ratios
    • Siddiqui K.M., Siegel E.L., Reiner B.I., et al. Correlation of radiologists' image quality perception with quantitative assessment parameters: just-noticeable difference vs. peak signal-to-noise ratios. Proc SPIE 5748 (2005) 58-64
    • (2005) Proc SPIE , vol.5748 , pp. 58-64
    • Siddiqui, K.M.1    Siegel, E.L.2    Reiner, B.I.3
  • 36
    • 0041817694 scopus 로고    scopus 로고
    • Using a human visual system model to optimize soft-copy mammography display
    • Krupinski E.A., Johnson J., Roehrig H., et al. Using a human visual system model to optimize soft-copy mammography display. Acad Radiol 10 (2003) 1030-1035
    • (2003) Acad Radiol , vol.10 , pp. 1030-1035
    • Krupinski, E.A.1    Johnson, J.2    Roehrig, H.3
  • 37
    • 85076750845 scopus 로고    scopus 로고
    • A comparison of two image quality models
    • Li B., Meyer G.W., and Klassen R.V. A comparison of two image quality models. Proc SPIE 3299 (1998) 98-109
    • (1998) Proc SPIE , vol.3299 , pp. 98-109
    • Li, B.1    Meyer, G.W.2    Klassen, R.V.3
  • 39
    • 84997701270 scopus 로고
    • A visual model for optimizing the design of image processing algorithms
    • Daly S. A visual model for optimizing the design of image processing algorithms. IEEE Int Conf Image Proc (1994) 16-20
    • (1994) IEEE Int Conf Image Proc , pp. 16-20
    • Daly, S.1
  • 40
    • 23844467547 scopus 로고    scopus 로고
    • Discrete cosine transform JPEG compression vs. 2D JPEG2000 compression: JNDmetrix visual discrimination model image quality analysis
    • Siddiqui K.M., Johnson J.P., Reiner B.I., et al. Discrete cosine transform JPEG compression vs. 2D JPEG2000 compression: JNDmetrix visual discrimination model image quality analysis. Proc SPIE 5748 (2005) 202-207
    • (2005) Proc SPIE , vol.5748 , pp. 202-207
    • Siddiqui, K.M.1    Johnson, J.P.2    Reiner, B.I.3
  • 42
    • 0029530359 scopus 로고
    • Image quality measures and their performance
    • Eskicioglu A.M., and Fisher P.S. Image quality measures and their performance. IEEE Trans Comm 43 (1995) 2959-2965
    • (1995) IEEE Trans Comm , vol.43 , pp. 2959-2965
    • Eskicioglu, A.M.1    Fisher, P.S.2
  • 44
    • 1942436689 scopus 로고    scopus 로고
    • Image quality assessment: from error visibility to structural similarity
    • Wang Z., Bovik A.C., Sheikh H.R., et al. Image quality assessment: from error visibility to structural similarity. IEEE Trans Image Proc 13 (2004) 600-612
    • (2004) IEEE Trans Image Proc , vol.13 , pp. 600-612
    • Wang, Z.1    Bovik, A.C.2    Sheikh, H.R.3
  • 45
    • 33747827820 scopus 로고    scopus 로고
    • Computed tomography diagnosis of acute appendicitis: advantages of reviewing thin-section datasets using sliding slab average intensity projection technique
    • Lee K.H., Kim Y.H., Hahn S., et al. Computed tomography diagnosis of acute appendicitis: advantages of reviewing thin-section datasets using sliding slab average intensity projection technique. Invest Radiol 41 (2006) 579-585
    • (2006) Invest Radiol , vol.41 , pp. 579-585
    • Lee, K.H.1    Kim, Y.H.2    Hahn, S.3
  • 46
    • 0842323879 scopus 로고    scopus 로고
    • Multislice CT: technical principles and future trends
    • Prokop M. Multislice CT: technical principles and future trends. Eur Radiol 13 Suppl 5 (2003) M3-M13
    • (2003) Eur Radiol , vol.13 , Issue.SUPPL. 5
    • Prokop, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.