메뉴 건너뛰기




Volumn 38, Issue 3, 2009, Pages 242-288

Microchip-based capillary electrophoresis for DNA analysis in modern biotechnology: A review

Author keywords

DNA; Genetically modified organisms; Microchip electrophoresis; Programmed field strength gradients

Indexed keywords

ANALYTICAL TECHNOLOGY; CLINICAL RESEARCH; DNA ANALYSIS; DNA FRAGMENT; FIELD STRENGTHS; GENETICALLY MODIFIED ORGANISMS; MICRO-FLUIDIC DEVICES; MICROCHIP ELECTROPHORESIS; MODERN BIOLOGY; MOLECULAR MANIPULATION; POTENTIAL APPLICATIONS; PROGRAMMED FIELD STRENGTH GRADIENTS; SIMULTANEOUS ANALYSIS; SMART DEVICES; VOLUME ANALYSIS;

EID: 70449635653     PISSN: 15422119     EISSN: 15422127     Source Type: Journal    
DOI: 10.1080/15422110903095136     Document Type: Article
Times cited : (24)

References (157)
  • 1
    • 27744560336 scopus 로고    scopus 로고
    • Application of capillary electrophoresis on microchip
    • Dolnik, V. and Liu, S. (2005) Application of capillary electrophoresis on microchip. J. Sep. Sci., 28: 1994-2009
    • (2005) J. Sep. Sci , vol.28 , pp. 1994-2009
    • Dolnik, V.1    Liu, S.2
  • 2
    • 0033989120 scopus 로고    scopus 로고
    • Capillary electrophoresis on microchip
    • Dolnik, V., Liu, S., and Jovanovich, S. (2000) Capillary electrophoresis on microchip. Electrophoresis, 21: 41-54
    • (2000) Electrophoresis , vol.21 , pp. 41-54
    • Dolnik, V.1    Liu, S.2    Jovanovich, S.3
  • 3
    • 29744467957 scopus 로고    scopus 로고
    • Clinical analysis by microchip capillary electrophoresis
    • Li, S.F.Y. and Kricka, J.L. (2006) Clinical analysis by microchip capillary electrophoresis. Clin. Chem., 52: 37-45
    • (2006) Clin. Chem , vol.52 , pp. 37-45
    • Li, S.F.Y.1    Kricka, J.L.2
  • 4
    • 0014159493 scopus 로고
    • Free zone electrophoresis
    • Hjerten, S. (1967) Free zone electrophoresis. Chromatogr. Rev., 9: 122-219
    • (1967) Chromatogr. Rev , vol.9 , pp. 122-219
    • Hjerten, S.1
  • 5
    • 0019589571 scopus 로고
    • Zone electrophoresis in opentubular glass capillaries
    • Jorgenson, J.W. and Lukacs, K.D. (1981) Zone electrophoresis in opentubular glass capillaries. Anal. Chem., 53: 1298-1302
    • (1981) Anal. Chem , vol.53 , pp. 1298-1302
    • Jorgenson, J.W.1    Lukacs, K.D.2
  • 7
    • 0025207507 scopus 로고
    • Miniaturized total chemical analysis systems: A novel concept for chemical sensing
    • Manz, A., Graber, N., and Widmer, H.M. (1990) Miniaturized total chemical analysis systems: A novel concept for chemical sensing. Sensors and Actuators B, 1: 244-248
    • (1990) Sensors and Actuators B , vol.1 , pp. 244-248
    • Manz, A.1    Graber, N.2    Widmer, H.M.3
  • 8
    • 0037096666 scopus 로고    scopus 로고
    • Micro total analysis systems. 1. Introduction, theory, and technology
    • DOI 10.1021/ac0202435
    • Reyes, D.R., Lossifidis, D., Auroux, P.A., and Manz, A. (2002) Micro total analysis systems. 1. Introduction, theory and technology. Anal. Chem., 74: 2623-2636 (Pubitemid 34651165)
    • (2002) Analytical Chemistry , vol.74 , Issue.12 , pp. 2623-2636
    • Reyes, D.R.1    Iossifidis, D.2    Auroux, P.-A.3    Manz, A.4
  • 11
    • 0037126895 scopus 로고    scopus 로고
    • Bioanalysis in microfluidic devices
    • Khandurina, J. and Guttman, A. (2002) Bioanalysis in microfluidic devices. J. Chromatogr. A, 943: 159-183
    • (2002) J. Chromatogr. A , vol.943 , pp. 159-183
    • Khandurina, J.1    Guttman, A.2
  • 12
    • 18844367723 scopus 로고    scopus 로고
    • Microchip-based electrochromatography: Designs and applications
    • Pumera, M. (2005) Microchip-based electrochromatography: designs and applications. Talanta, 66: 1048-1062
    • (2005) Talanta , vol.66 , pp. 1048-1062
    • Pumera, M.1
  • 13
    • 4344585484 scopus 로고    scopus 로고
    • Polymer solutions and entropic-based systems for double-stranded DNA capillary electrophoresis and microchip electrophoresis
    • Feng, X. and Baba, Y. (2004) Polymer solutions and entropic-based systems for double-stranded DNA capillary electrophoresis and microchip electrophoresis. Electrophoresis, 25: 2332-2345
    • (2004) Electrophoresis , vol.25 , pp. 2332-2345
    • Feng, X.1    Baba, Y.2
  • 14
    • 2442553856 scopus 로고    scopus 로고
    • Micro total analysis system (m-TAS) in biotechnology
    • Lee, S.J. and Lee, S.Y. (2004) Micro total analysis system (m-TAS) in biotechnology. Appl. Microbiol. Biotechnol., 64: 289-299
    • (2004) Appl. Microbiol. Biotechnol , vol.64 , pp. 289-299
    • Lee, S.J.1    Lee, S.Y.2
  • 15
    • 13444257560 scopus 로고    scopus 로고
    • Rapid microvolume PCR of DNA confirmed by microchip electrophoresis
    • Hataoka, Y., Zhang, L., Yukimasa, T., and Baba, Y. (2005) Rapid microvolume PCR of DNA confirmed by microchip electrophoresis. Anal. Sci., 21: 53-56
    • (2005) Anal. Sci , vol.21 , pp. 53-56
    • Hataoka, Y.1    Zhang, L.2    Yukimasa, T.3    Baba, Y.4
  • 17
    • 0033986278 scopus 로고    scopus 로고
    • Analysis of DNA fragments by microchip electrophoresis fabricated on poly(methyl methacrylate) substrates using a wire-imprinting method
    • Chen, Y. and Chen, S. (2000) Analysis of DNA fragments by microchip electrophoresis fabricated on poly(methyl methacrylate) substrates using a wire-imprinting method. Electrophoresis, 21: 165-170
    • (2000) Electrophoresis , vol.21 , pp. 165-170
    • Chen, Y.1    Chen, S.2
  • 18
    • 33845402660 scopus 로고    scopus 로고
    • Electrophoresis in nanochannels: Brief review and speculation
    • Baldessari, F. and Santiago, J.G. (2006) Electrophoresis in nanochannels: brief review and speculation. J. Nanobiotechnol., 4: 1-6
    • (2006) J. Nanobiotechnol , vol.4 , pp. 1-6
    • Baldessari, F.1    Santiago, J.G.2
  • 20
    • 0033794783 scopus 로고    scopus 로고
    • Rapid detection of deletion, insertion, and substitution mutations via heteroduplex analysis using capillary- and microchip-based electrophoresis
    • Tian, H.J., Brody, L.C., and Landers, J.P. (2000) Rapid detection of deletion, insertion, and substitution mutations via heteroduplex analysis using capillary- and microchip-based electrophoresis. Genome Res., 10: 1403-1413
    • (2000) Genome Res , vol.10 , pp. 1403-1413
    • Tian, H.J.1    Brody, L.C.2    Landers, J.P.3
  • 21
    • 0037437680 scopus 로고    scopus 로고
    • Microchip electrophoresis-based separation of DNA
    • Zhang, L., Dang, F., and Baba, Y. (2003) Microchip electrophoresis-based separation of DNA. J. Pharmaceut. Biomed. Anal., 30: 1645-1654
    • (2003) J. Pharmaceut. Biomed. Anal , vol.30 , pp. 1645-1654
    • Zhang, L.1    Dang, F.2    Baba, Y.3
  • 22
    • 11944262834 scopus 로고
    • Capillary electrophoresis and sample injection systems integrated on a planar glass chip
    • Harrison, D.J., Manz, A., Fan, Z., Luedi, H., and Widmer, H.M. (1992) Capillary electrophoresis and sample injection systems integrated on a planar glass chip. Anal. Chem., 64: 1926-1932
    • (1992) Anal. Chem , vol.64 , pp. 1926-1932
    • Harrison, D.J.1    Manz, A.2    Fan, Z.3    Luedi, H.4    Widmer, H.M.5
  • 24
    • 0034828783 scopus 로고    scopus 로고
    • Multiple-channel microchips for highthroughput DNA analysis by capillary electrophoresis
    • Gao, Q., Shi, Y., and Liu, S. (2001) Multiple-channel microchips for highthroughput DNA analysis by capillary electrophoresis. Fres. J. Anal. Chem., 371: 137-145
    • (2001) Fres. J. Anal. Chem , vol.371 , pp. 137-145
    • Gao, Q.1    Shi, Y.2    Liu, S.3
  • 26
    • 0033485575 scopus 로고    scopus 로고
    • Acoustooptical deflection-based laser beam scanning for fluorescence detection on multichannel electrophoretic microchips
    • Huang, Z., Munro, N., Hühmer, A.F.R., and Landers, J.P. (1999) Acoustooptical deflection-based laser beam scanning for fluorescence detection on multichannel electrophoretic microchips. Anal. Chem., 71: 5309-5314
    • (1999) Anal. Chem , vol.71 , pp. 5309-5314
    • Huang, Z.1    Munro, N.2    Hühmer, A.F.R.3    Landers, J.P.4
  • 28
    • 4244166752 scopus 로고    scopus 로고
    • High-speed DNA genotyping using microfabricated capillary array electrophoresis chips
    • Woolley, A.T., Sensabaugh, G.F., and Mathies, R.A. (1997) High-speed DNA genotyping using microfabricated capillary array electrophoresis chips. Anal. Chem., 69: 2181-2186
    • (1997) Anal. Chem , vol.69 , pp. 2181-2186
    • Woolley, A.T.1    Sensabaugh, G.F.2    Mathies, R.A.3
  • 30
    • 0037154216 scopus 로고    scopus 로고
    • High throughput DNA sequencing with a microfabricated 96- lane capillary array electrophoresis bioprocessor
    • Paegel, B.M., Emrich, C.A., Wedemayer, G.J., Scherer, J.R., and Mathies, R.A. (2002) High throughput DNA sequencing with a microfabricated 96- lane capillary array electrophoresis bioprocessor. Proc. Natl. Acad. Sci. USA, 99: 574-579
    • (2002) Proc. Natl. Acad. Sci. USA , vol.99 , pp. 574-579
    • Paegel, B.M.1    Emrich, C.A.2    Wedemayer, G.J.3    Scherer, J.R.4    Mathies, R.A.5
  • 31
    • 30144432504 scopus 로고    scopus 로고
    • Analysis of multiplex PCR fragments with PMMA microchip electrophoresis
    • Liu, D., Zhou, X., Zhong, R., Ye, N., Chang, G., Xiong, W., Mei, X., and Lin, B. (2006) Analysis of multiplex PCR fragments with PMMA microchip electrophoresis. Talanta, 68: 616-622
    • (2006) Talanta , vol.68 , pp. 616-622
    • Liu, D.1    Zhou, X.2    Zhong, R.3    Ye, N.4    Chang, G.5    Xiong, W.6    Mei, X.7    Lin, B.8
  • 32
    • 9244238182 scopus 로고    scopus 로고
    • Diversity of base-pair conformations and their occurrence in rRNA structure and RNA structural motifs
    • Lee, J.C. and Gutell, R.R. (2004) Diversity of base-pair conformations and their occurrence in rRNA structure and RNA structural motifs. J. Mol. Biol., 344: 1225-1249
    • (2004) J. Mol. Biol , vol.344 , pp. 1225-1249
    • Lee, J.C.1    Gutell, R.R.2
  • 33
    • 0006194302 scopus 로고    scopus 로고
    • Barciszewski, J. and Frederic, B.F.C. (eds.) Kluwer Academic: Boston, MA
    • Barciszewski, J. and Frederic, B.F.C. (eds.). (1999) RNA Biochemistry and Biotechnology. Kluwer Academic: Boston, MA, pp. 73-87
    • (1999) RNA Biochemistry and Biotechnology , pp. 73-87
  • 36
    • 0032922742 scopus 로고    scopus 로고
    • Antisense RNA gene therapy for studying and modulating biological processes
    • Weiss, B., Davidkova, G., and Zhou, L.W. (1999) Antisense RNA gene therapy for studying and modulating biological processes. Cell. Mol. Life Sci., 55: 334-358
    • (1999) Cell. Mol. Life Sci , vol.55 , pp. 334-358
    • Weiss, B.1    Davidkova, G.2    Zhou, L.W.3
  • 37
    • 0035220362 scopus 로고    scopus 로고
    • Replaceable polymers for DNA sequencing by capillary electrophoresis
    • Quesada, M.A. and Menchen, S. (2001) Replaceable polymers for DNA sequencing by capillary electrophoresis. Methods Mol. Biol., 162: 139-166
    • (2001) Methods Mol. Biol , vol.162 , pp. 139-166
    • Quesada, M.A.1    Menchen, S.2
  • 38
    • 0023665648 scopus 로고
    • High-performance sodium dodecyl sulfate polyacrylamide gel capillary electrophoresis of peptides and proteins
    • Cohen, A.S. and Karger, B.L. (1987) High-performance sodium dodecyl sulfate polyacrylamide gel capillary electrophoresis of peptides and proteins. J. Chromatogr., 397: 409-417
    • (1987) J. Chromatogr , vol.397 , pp. 409-417
    • Cohen, A.S.1    Karger, B.L.2
  • 39
    • 0032043390 scopus 로고    scopus 로고
    • A matrix for DNA separation: Genotyping and sequencing using poly(vinylpyrrolidone) solution in uncoated capillaries
    • Gao, Q. and Yeung, E.S. (1998) A matrix for DNA separation: genotyping and sequencing using poly(vinylpyrrolidone) solution in uncoated capillaries. Anal. Chem., 70: 1382-1388 (Pubitemid 128669453)
    • (1998) Analytical Chemistry , vol.70 , Issue.7 , pp. 1382-1388
    • Gao, Q.1
  • 40
    • 0035098616 scopus 로고    scopus 로고
    • Optimization of DNA electrophoretic behavior in poly(vinyl pyrrolidone) sieving matrix for DNA sequencing
    • Song, J.M. and Yeung, E.S. (2001) Optimization of DNA electrophoretic behavior in poly(vinyl pyrrolidone) sieving matrix for DNA sequencing. Electrophoresis, 22: 748-754
    • (2001) Electrophoresis , vol.22 , pp. 748-754
    • Song, J.M.1    Yeung, E.S.2
  • 41
    • 70449658586 scopus 로고    scopus 로고
    • Ultra-fast simultaneous analysis of GMOs in maize by microchip electrophoresis with laser-induced fluorescence detector
    • Kailasa, S.K. and Kang, S.H. (2007) Ultra-fast simultaneous analysis of GMOs in maize by microchip electrophoresis with laser-induced fluorescence detector. Electrophoresis, 28: 4247-4254
    • (2007) Electrophoresis , vol.28 , pp. 4247-4254
    • Kailasa, S.K.1    Kang, S.H.2
  • 42
    • 0343851564 scopus 로고    scopus 로고
    • High-speed chiral separations on microchip electrophoresis devices
    • Rodriguez, I., Jin, L.J., and Li, S.F.Y. (2000) High-speed chiral separations on microchip electrophoresis devices. Electrophoresis, 21: 211-219
    • (2000) Electrophoresis , vol.21 , pp. 211-219
    • Rodriguez, I.1    Jin, L.J.2    Li, S.F.Y.3
  • 43
    • 0034002175 scopus 로고    scopus 로고
    • Single strand conformation polymorphism analysis by capillary and microchip electrophoresis: A fast, simple method for detection of common mutations in BRCA1 and BRCA2
    • Tian, H., Jaquins-Gerstl, A., Munro, N., Trucco, M., Brody, L.C., and Landers, J.P. (2000) Single strand conformation polymorphism analysis by capillary and microchip electrophoresis: A fast, simple method for detection of common mutations in BRCA1 and BRCA2. Genomics, 63: 25-34
    • (2000) Genomics , vol.63 , pp. 25-34
    • Tian, H.1    Jaquins-Gerstl, A.2    Munro, N.3    Trucco, M.4    Brody, L.C.5    Landers, J.P.6
  • 44
    • 0035142744 scopus 로고    scopus 로고
    • DNA analysis on electrophoretic microchips: Effect of operational variables
    • Ronal, Z., Barta, C., Sasvari-Szekely, M., and Guttman, A. (2001) DNA analysis on electrophoretic microchips: Effect of operational variables. Electrophoresis, 22: 294-299
    • (2001) Electrophoresis , vol.22 , pp. 294-299
    • Ronal, Z.1    Barta, C.2    Sasvari-Szekely, M.3    Guttman, A.4
  • 45
    • 31444442778 scopus 로고    scopus 로고
    • Chemiluminescence detection for capillary electrophoresis and microchip capillary electrophoresis
    • DOI 10.1016/j.trac.2005.07.001, PII S0165993605001755
    • Huang, X. and Ren, J. (2006) Chemiluminescence detection for capillary electrophoresis and microchip capillary electrophoresis, Trends Anal. Chem., 25: 155-166 (Pubitemid 43152037)
    • (2006) TrAC - Trends in Analytical Chemistry , vol.25 , Issue.2 , pp. 155-166
    • Huang, X.1    Ren, J.2
  • 46
    • 0036863549 scopus 로고    scopus 로고
    • Recent developments in amperometric detection for microchip capillary electrophoresis
    • Vandaveer IV, W.R., Pasas, S.A., Martin, R.S., and Lunte, M.S. (2002) Recent developments in amperometric detection for microchip capillary electrophoresis. Electrophoresis, 23: 3667-3677
    • (2002) Electrophoresis , vol.23 , pp. 3667-3677
    • Vandaveer Iv, W.R.1    Pasas, S.A.2    Martin, R.S.3    Lunte, M.S.4
  • 48
    • 0036790244 scopus 로고    scopus 로고
    • Microliter format for simultaneous multianalyte detection and development of a PCR chemiluminescent enzyme immunoassay for typing human papillomavirus DNAs
    • Aldo, R., Mara, M., Simona, V., Monica, C., Francesca, B., Mario, B., Patrizia, P., Marialuisa, Z., and Monica, M. (2002) Microliter format for simultaneous multianalyte detection and development of a PCR chemiluminescent enzyme immunoassay for typing human papillomavirus DNAs. Clin. Chem., 48: 1654-1660
    • (2002) Clin. Chem , vol.48 , pp. 1654-1660
    • Aldo, R.1    Mara, M.2    Simona, V.3    Monica, C.4    Francesca, B.5    Mario, B.6    Patrizia, P.7    Marialuisa, Z.8    Monica, M.9
  • 49
    • 1242273723 scopus 로고    scopus 로고
    • Chemiluminescent detection of genetic polymorphisms based on mismatch hybridization: Application to cytochrome P4501A1
    • Wu, X., Zhou, Y., and Xu, S. (2004) Chemiluminescent detection of genetic polymorphisms based on mismatch hybridization: Application to cytochrome P4501A1. Mol. Cell. Probes, 18: 17-22
    • (2004) Mol. Cell. Probes , vol.18 , pp. 17-22
    • Wu, X.1    Zhou, Y.2    Xu, S.3
  • 50
    • 4444225584 scopus 로고    scopus 로고
    • Electrochemiluminescence detection with integrated indium tin oxideelectrode on electrophoretic microchip for direct bioanalysis of lincomycin in the urine
    • Zhao, X., You, T., Qiu, H., Yan, J., Yang, X., and Wang, E. (2004) Electrochemiluminescence detection with integrated indium tin oxideelectrode on electrophoretic microchip for direct bioanalysis of lincomycin in the urine. J. Chromatogr. B, 810: 137-142
    • (2004) J. Chromatogr. B , vol.810 , pp. 137-142
    • Zhao, X.1    You, T.2    Qiu, H.3    Yan, J.4    Yang, X.5    Wang, E.6
  • 52
    • 0023650982 scopus 로고
    • Automated DNA sequencing: Ultrasensitive detection of fluorescent bands during electrophoresis
    • Ansorge, W., Sproat, B., Stegemann, J., Schwager, C., and Zenke, M. (1987) Automated DNA sequencing: ultrasensitive detection of fluorescent bands during electrophoresis. Nucl. Acids Res., 15: 4593-4602
    • (1987) Nucl. Acids Res , vol.15 , pp. 4593-4602
    • Ansorge, W.1    Sproat, B.2    Stegemann, J.3    Schwager, C.4    Zenke, M.5
  • 55
    • 3242665504 scopus 로고    scopus 로고
    • Fast diagnosis of bovine theileriosis by whole blood PCR and microchip electrophoresis
    • Jang, S., Cho, K., Chae, J.S., and Kang, S.H. (2004) Fast diagnosis of bovine theileriosis by whole blood PCR and microchip electrophoresis. Bull. Korean Chem. Soc., 25: 757-760
    • (2004) Bull. Korean Chem. Soc , vol.25 , pp. 757-760
    • Jang, S.1    Cho, K.2    Chae, J.S.3    Kang, S.H.4
  • 56
    • 33749023293 scopus 로고    scopus 로고
    • Single-strand conformation polymorphism analysis by microchip electrophoresis for the rapid detection of point mutation in human obesity gene
    • Kang, S.H., Jang, S., and Park, S.K. (2006) Single-strand conformation polymorphism analysis by microchip electrophoresis for the rapid detection of point mutation in human obesity gene. Bull. Korean Chem. Soc., 27: 1346-1352
    • (2006) Bull. Korean Chem. Soc , vol.27 , pp. 1346-1352
    • Kang, S.H.1    Jang, S.2    Park, S.K.3
  • 57
    • 24144478887 scopus 로고    scopus 로고
    • Separation of DNA fragments for fast diagnosis by microchip electrophoresis using programmed field strength gradient
    • Kang, S.H., Park, M., and Cho, K. (2005) Separation of DNA fragments for fast diagnosis by microchip electrophoresis using programmed field strength gradient. Electrophoresis, 26: 3179-3184
    • (2005) Electrophoresis , vol.26 , pp. 3179-3184
    • Kang, S.H.1    Park, M.2    Cho, K.3
  • 58
    • 21544448360 scopus 로고    scopus 로고
    • Microchip capillary gel electrophoresis using programmed field strength gradients for the ultra-fast analysis of genetically modified organisms in soybeans
    • Kim, Y.J., Chae, J.S., Chang, J.K., and Kang, S.H. (2005) Microchip capillary gel electrophoresis using programmed field strength gradients for the ultra-fast analysis of genetically modified organisms in soybeans. J. Chromatogr, A, 1083: 179-184
    • (2005) J. Chromatogr, A , vol.1083 , pp. 179-184
    • Kim, Y.J.1    Chae, J.S.2    Chang, J.K.3    Kang, S.H.4
  • 59
    • 33947179890 scopus 로고    scopus 로고
    • Frontal analysis in microchip CE: A simple and accurate method for determination of protein-DNA dissociation constant
    • Gong, M., Wehmeyer, K.R., Limbach, P.A., and Heineman, W.R. (2007) Frontal analysis in microchip CE: A simple and accurate method for determination of protein-DNA dissociation constant. Electrophoresis, 28: 837-842
    • (2007) Electrophoresis , vol.28 , pp. 837-842
    • Gong, M.1    Wehmeyer, K.R.2    Limbach, P.A.3    Heineman, W.R.4
  • 60
    • 33750268533 scopus 로고    scopus 로고
    • Microchip and single-photon avalache diodes for DNA separation with high sensitivity
    • Ivan, R., Sergio, C., Alessandro, R., Massimo, G., Marcella, C., and Marina, C. (2006) Microchip and single-photon avalache diodes for DNA separation with high sensitivity. Electrophoresis, 27: 3797-3804
    • (2006) Electrophoresis , vol.27 , pp. 3797-3804
    • Ivan, R.1    Sergio, C.2    Alessandro, R.3    Massimo, G.4    Marcella, C.5    Marina, C.6
  • 61
    • 0037109692 scopus 로고    scopus 로고
    • Hydroxyethylcellulose as an effective polymer network for DNA analysis in uncoated glass microchips: Optimization and application to mutation detection via heteroduplex analysis
    • Tian, H.J. and Landers, J.P. (2002) Hydroxyethylcellulose as an effective polymer network for DNA analysis in uncoated glass microchips: optimization and application to mutation detection via heteroduplex analysis. Anal. Biochem., 309: 212-223
    • (2002) Anal. Biochem , vol.309 , pp. 212-223
    • Tian, H.J.1    Landers, J.P.2
  • 62
    • 0036894404 scopus 로고    scopus 로고
    • Dual conductivity/amperometric detection system for microchip capillary electrophoresis
    • Wang, J. and Pumera, M. (2002) Dual conductivity/amperometric detection system for microchip capillary electrophoresis. Anal. Chem., 74: 5919-5923
    • (2002) Anal. Chem , vol.74 , pp. 5919-5923
    • Wang, J.1    Pumera, M.2
  • 63
    • 0036864617 scopus 로고    scopus 로고
    • Conductimetric and potentiometric detection in conventional and microchip capillary electrophoresis
    • DOI 10.1002/1522-2683(200211)23:21<3659::AID-ELPS3659>3.0.CO;2-M
    • Tanyanyiwa, J., Leuthardt, S., and Hauser, P.C. (2002) Conductimetric and potentiometric detection in conventional and microchip capillary electrophoresis. Electrophoresis, 23: 3659-3666 (Pubitemid 35469547)
    • (2002) Electrophoresis , vol.23 , Issue.21 , pp. 3659-3666
    • Tanyanyiwa, J.1    Leuthardt, S.2    Hauser, P.C.3
  • 64
    • 2342517480 scopus 로고    scopus 로고
    • Development of a microfabricated palladium decoupler/electrochemical detector for microchip capillaryelectrophoresis using a hybrid glass/poly(dimethylsiloxane) device
    • Lacher, N.A. and Lunte, S.M. (2004) Development of a microfabricated palladium decoupler/electrochemical detector for microchip capillaryelectrophoresis using a hybrid glass/poly(dimethylsiloxane) device. Anal. Chem., 76: 2482-2491
    • (2004) Anal. Chem , vol.76 , pp. 2482-2491
    • Lacher, N.A.1    Lunte, S.M.2
  • 65
    • 33749566620 scopus 로고    scopus 로고
    • Analytical performance of CE microchips with amperometric detection instrumentation
    • Castano-Alvarez, M., Fernandez-Abedul, M., and Costa-Garcia, A. (2006) Analytical performance of CE microchips with amperometric detection instrumentation. Science & Technology, 34, pp. 697-710
    • (2006) Science & Technology , vol.34 , pp. 697-710
    • Castano-Alvarez, M.1    Fernandez-Abedul, M.2    Costa-Garcia, A.3
  • 66
    • 0029817378 scopus 로고    scopus 로고
    • Continuous separations with microfabricated electrophoresis- electrochemical array detection
    • Gavin, P.F. and Ewing, A.G. (1996) Continuous separations with microfabricated electrophoresis-electrochemical array detection. J. Am. Chem. Soc., 118: 8932-8936
    • (1996) J. Am. Chem. Soc , vol.118 , pp. 8932-8936
    • Gavin, P.F.1    Ewing, A.G.2
  • 67
    • 0000227812 scopus 로고    scopus 로고
    • Characterization of electrochemical array detection for continuous channel electrophoretic separations in micrometer and submicrometer channels
    • Gavin, P.F. and Ewing, A.G. (1997) Characterization of electrochemical array detection for continuous channel electrophoretic separations in micrometer and submicrometer channels. Anal. Chem., 69: 3838-3845
    • (1997) Anal. Chem , vol.69 , pp. 3838-3845
    • Gavin, P.F.1    Ewing, A.G.2
  • 68
    • 0000740598 scopus 로고    scopus 로고
    • Characterization of lateral dispersion in microfabricated electrophoresis-electrochemical array detection
    • Gavin, P.F. and Ewing, A.G. (1998) Characterization of lateral dispersion in microfabricated electrophoresis-electrochemical array detection. J. Microcolumn Separ., 10: 357-364
    • (1998) J. Microcolumn Separ , vol.10 , pp. 357-364
    • Gavin, P.F.1    Ewing, A.G.2
  • 69
    • 0032001616 scopus 로고    scopus 로고
    • Capillary electrophoresis chips with integrated electrochemical detection
    • Woolley, A.T., Lao, K., Glazer, A.N., and Mathies, R.A. (1998) Capillary electrophoresis chips with integrated electrochemical detection. Anal. Chem., 70: 684-688
    • (1998) Anal. Chem , vol.70 , pp. 684-688
    • Woolley, A.T.1    Lao, K.2    Glazer, A.N.3    Mathies, R.A.4
  • 70
    • 23844479713 scopus 로고    scopus 로고
    • Microchip electrophoresis with a cellulose-DNA modified screen printed electrode for the analysis of neurotransmitters
    • Shiddiky, M.J.A., Kim, R.E., and Shim, Y.B. (2005) Microchip electrophoresis with a cellulose-DNA modified screen printed electrode for the analysis of neurotransmitters. Electrophoresis, 26: 3043-3052
    • (2005) Electrophoresis , vol.26 , pp. 3043-3052
    • Shiddiky, M.J.A.1    Kim, R.E.2    Shim, Y.B.3
  • 71
    • 33846565774 scopus 로고    scopus 로고
    • Determination of cationic neurotransmitters and metabolites in brain homogenates by microchip electrophoresis and carbon nanotube-modified amperometry
    • Vlckova, M. and Schwarz, M.A. (2007) Determination of cationic neurotransmitters and metabolites in brain homogenates by microchip electrophoresis and carbon nanotube-modified amperometry. J. Chromatogr. A, 1142: 214-221
    • (2007) J. Chromatogr. A , vol.1142 , pp. 214-221
    • Vlckova, M.1    Schwarz, M.A.2
  • 72
    • 34249040859 scopus 로고    scopus 로고
    • Trace analysis of DNA: Preconcentration, separation, and electrochemical detection in microchip electrophoresis using Au nanoparticles
    • Shiddiky, M.J.A. and Shim, Y.B. (2007) Trace analysis of DNA: preconcentration, separation, and electrochemical detection in microchip electrophoresis using Au nanoparticles. Anal. Chem., 79: 3724-3733
    • (2007) Anal. Chem , vol.79 , pp. 3724-3733
    • Shiddiky, M.J.A.1    Shim, Y.B.2
  • 73
    • 15944368874 scopus 로고    scopus 로고
    • Development of a microfabricated disposable microchip with a capillary electrophoresis and integrated threeelectrode electrochemcial detection
    • Kim, J.H.,Kang, C.J., and Kim, S.Y. (2005) Development of a microfabricated disposable microchip with a capillary electrophoresis and integrated threeelectrode electrochemcial detection. Biosensors Bioelectron., 20: 2314-2317
    • (2005) Biosensors Bioelectron , vol.20 , pp. 2314-2317
    • Kim, J.H.1    Kang, C.J.2    Kim, S.Y.3
  • 74
    • 0142219928 scopus 로고    scopus 로고
    • Analysis of doublestranded DNA by microchip capillary electrophoresis using polymer solutions containing gold nanoparticles
    • Lin, Y.W., Huang, M.J., and Chang, H.T. (2003) Analysis of doublestranded DNA by microchip capillary electrophoresis using polymer solutions containing gold nanoparticles. J. Chromatogr. A, 1014: 47-55
    • (2003) J. Chromatogr. A , vol.1014 , pp. 47-55
    • Lin, Y.W.1    Huang, M.J.2    Chang, H.T.3
  • 75
    • 0035800067 scopus 로고    scopus 로고
    • Chromophore structure in lumirhodopsin and metarhodopsin i by time resolved resonance Raman microchip spectroscopy
    • Pan, D. and Mathies, R.A. (2001) Chromophore structure in lumirhodopsin and metarhodopsin I by time resolved resonance Raman microchip spectroscopy. Biochemistry, 40: 7929-7936
    • (2001) Biochemistry , vol.40 , pp. 7929-7936
    • Pan, D.1    Mathies, R.A.2
  • 76
    • 0036534856 scopus 로고    scopus 로고
    • Single-cell analysis by a scanning thermal lens microscope with a microchip: Direct monitoring of cytochrome c distribution during apoptosis process
    • Tamaki, E., Sato, K., Tokeshi, M., Sato, K., Aihara, M., and Kitamori, T. (2002) Single-cell analysis by a scanning thermal lens microscope with a microchip: Direct monitoring of cytochrome c distribution during apoptosis process. Anal. Chem., 74: 1560-1564
    • (2002) Anal. Chem , vol.74 , pp. 1560-1564
    • Tamaki, E.1    Sato, K.2    Tokeshi, M.3    Sato, K.4    Aihara, M.5    Kitamori, T.6
  • 77
    • 7944225288 scopus 로고    scopus 로고
    • Suppression of nonspecific adsorption using sheath flow
    • Munson, M.S., Hasenbank, M.S., Fu, E., and Yager, P. (2004) Suppression of nonspecific adsorption using sheath flow. Lab on a Chip, 4: 438-445
    • (2004) Lab on A Chip , vol.4 , pp. 438-445
    • Munson, M.S.1    Hasenbank, M.S.2    Fu, E.3    Yager, P.4
  • 78
    • 0036712676 scopus 로고    scopus 로고
    • A microscale-molecular weight sensor: Probing molecular diffusion between adjacent laminar flows by refractive index gradient detection
    • Costin, C.D. and Synovec, R.E. (2002) A microscale-molecular weight sensor: Probing molecular diffusion between adjacent laminar flows by refractive index gradient detection. Anal. Chem., 74: 4558-4565
    • (2002) Anal. Chem , vol.74 , pp. 4558-4565
    • Costin, C.D.1    Synovec, R.E.2
  • 79
    • 0031816049 scopus 로고    scopus 로고
    • Holographic refractive index detector for application in microchipbased separation systems
    • Burggraf, N., Krattiger, B., de Mello, A.J., de Rooij, N.F., and Manz, A. (1998) Holographic refractive index detector for application in microchipbased separation systems. Analyst, 123: 1443-1447
    • (1998) Analyst , vol.123 , pp. 1443-1447
    • Burggraf, N.1    Krattiger, B.2    De Mello, A.J.3    De Rooij, N.F.4    Manz, A.5
  • 80
    • 0030850138 scopus 로고    scopus 로고
    • Integrated multichannel microchip electrospray ionization mass spectrometry: Analysis of peptides from on-chip tryptic digestion of melittin
    • Xue, Q., Dunayevskiy, Y.M., Foret, F., and Karger, B.L. (1997) Integrated multichannel microchip electrospray ionization mass spectrometry: Analysis of peptides from on-chip tryptic digestion of melittin. Rapid Commun. Mass Spectrom., 11: 1253-1256
    • (1997) Rapid Commun. Mass Spectrom , vol.11 , pp. 1253-1256
    • Xue, Q.1    Dunayevskiy, Y.M.2    Foret, F.3    Karger, B.L.4
  • 81
    • 0005036961 scopus 로고    scopus 로고
    • Generating electrospray from microchip devices using electroosmotic pumping
    • Ramsey, R.S. and Ramsey, J.M. (1997) Generating electrospray from microchip devices using electroosmotic pumping. Anal. Chem., 69: 1174-1178
    • (1997) Anal. Chem , vol.69 , pp. 1174-1178
    • Ramsey, R.S.1    Ramsey, J.M.2
  • 82
    • 0033198571 scopus 로고    scopus 로고
    • Subattomole-sensitivity microchip nanoelectrospray source with time-offlight mass spectrometry detection
    • Lazar, I.M., Ramsey, R.S., Sundberg, S., and Ramsey, J.M. (1999) Subattomole-sensitivity microchip nanoelectrospray source with time-offlight mass spectrometry detection. Anal. Chem., 71: 3627-3631
    • (1999) Anal. Chem , vol.71 , pp. 3627-3631
    • Lazar, I.M.1    Ramsey, R.S.2    Sundberg, S.3    Ramsey, J.M.4
  • 83
    • 0036283726 scopus 로고    scopus 로고
    • Integrating micromachined devices with modern mass spectrometry
    • Limbach, P.A. and Meng, Z. (2002) Integrating micromachined devices with modern mass spectrometry. Analyst, 127: 693-700
    • (2002) Analyst , vol.127 , pp. 693-700
    • Limbach, P.A.1    Meng, Z.2
  • 84
    • 0036228575 scopus 로고    scopus 로고
    • Liquid phase interfacing and miniaturization in matrix-assisted laser desorption/ionization mass spectrometry
    • Foret, F. and Preisler, J. (2002) Liquid phase interfacing and miniaturization in matrix-assisted laser desorption/ionization mass spectrometry. Proteomics, 2: 360-372
    • (2002) Proteomics , vol.2 , pp. 360-372
    • Foret, F.1    Preisler, J.2
  • 85
    • 0036231855 scopus 로고    scopus 로고
    • Adapting arrays and lab-on-a-chip technology for proteomics
    • Figeys, D. (2002) Adapting arrays and lab-on-a-chip technology for proteomics, Proteomics. 2: 373-382
    • (2002) Proteomics , vol.2 , pp. 373-382
    • Figeys, D.1
  • 86
    • 29844439008 scopus 로고    scopus 로고
    • Quantitation in capillary electrophoresis-mass spectrometry
    • Ohnesorge, J., Neusüß, C., and Wätzig, H. (2005) Quantitation in capillary electrophoresis-mass spectrometry. Electrophoresis, 26: 3973-3987
    • (2005) Electrophoresis , vol.26 , pp. 3973-3987
    • Ohnesorge, J.1    Neusüß, C.2    Wätzig, H.3
  • 87
    • 33745738692 scopus 로고    scopus 로고
    • Microfabricated devices: A new sample introduction approach to mass spectrometry
    • Lazar, I.M., Grym, J., and Foret, F. (2006) Microfabricated devices: A new sample introduction approach to mass spectrometry. Mass Spectrom. Rev., 25: 573-594
    • (2006) Mass Spectrom. Rev , vol.25 , pp. 573-594
    • Lazar, I.M.1    Grym, J.2    Foret, F.3
  • 88
    • 33749477297 scopus 로고    scopus 로고
    • Microfluidic technologies for MALDIMS in proteomics
    • DeVoe, D.L. and Lee, C.S. (2006) Microfluidic technologies for MALDIMS in proteomics. Electrophoresis. 27: 3559-3568
    • (2006) Electrophoresis , vol.27 , pp. 3559-3568
    • Devoe, D.L.1    Lee, C.S.2
  • 89
    • 4344684428 scopus 로고    scopus 로고
    • Efficient electrospray ionization from polymer microchannels using integrated hydrophobic membranes
    • Wang, Y.X., Cooper, J.W, Lee, C.S., and DeVoe, D.L. (2004) Efficient electrospray ionization from polymer microchannels using integrated hydrophobic membranes. Lab Chip, 4: 363-367
    • (2004) Lab Chip , vol.4 , pp. 363-367
    • Wang, Y.X.1    Cooper, J.W.2    Lee, C.S.3    Devoe, D.L.4
  • 90
    • 26844538112 scopus 로고    scopus 로고
    • Simple chip-based interfaces for on-line monitoring of supramolecular interactions by nano-ESI MS
    • Brivio, M., Oosterbroeck, R.E., Verboom, W., van den Berg, A., and Reinhoudt, D.N. (2005) Simple chip-based interfaces for on-line monitoring of supramolecular interactions by nano-ESI MS. Lab Chip, 5: 1111-1122
    • (2005) Lab Chip , vol.5 , pp. 1111-1122
    • Brivio, M.1    Oosterbroeck, R.E.2    Verboom, W.3    Van Den Berg, A.4    Reinhoudt, D.N.5
  • 91
    • 0034134015 scopus 로고    scopus 로고
    • Separation and identification of peptides from gel-isolated membrane proteins using a microfabricated device for combined capillary electrophoresis/ nanoelectrospray mass spectrometry
    • Li, J., Kelly, J.F., Chernushevich, I., Harrison, D.J., and Thibault, P. (2000) Separation and identification of peptides from gel-isolated membrane proteins using a microfabricated device for combined capillary electrophoresis/ nanoelectrospray mass spectrometry. Anal. Chem., 72: 599-609
    • (2000) Anal. Chem , vol.72 , pp. 599-609
    • Li, J.1    Kelly, J.F.2    Chernushevich, I.3    Harrison, D.J.4    Thibault, P.5
  • 92
    • 0032799817 scopus 로고    scopus 로고
    • Integration of microfabricated devices to capillary electrophoresis- electrospray mass spectrometry using a low dead volume connection: Application to rapid analyses of proteolytic digests
    • Li, J., Thibault, P., Bings, N.H., Skinner, C.D., Wang, C., Colyer, C., and Harrison, J. (1999) Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: Application to rapid analyses of proteolytic digests. Anal. Chem., 71, 3036-3045
    • (1999) Anal. Chem , vol.71 , pp. 3036-3045
    • Li, J.1    Thibault, P.2    Bings, N.H.3    Skinner, C.D.4    Wang, C.5    Colyer, C.6    Harrison, J.7
  • 93
    • 0034161639 scopus 로고    scopus 로고
    • A microdevice with integrated liquid junction for facile peptide and protein analysis by capillary electrophoresis/electrospray mass spectrometry
    • Zhang, B., Foret, F., and Karger, B.L. (2000) A microdevice with integrated liquid junction for facile peptide and protein analysis by capillary electrophoresis/electrospray mass spectrometry. Anal. Chem., 72: 1015-1022
    • (2000) Anal. Chem , vol.72 , pp. 1015-1022
    • Zhang, B.1    Foret, F.2    Karger, B.L.3
  • 94
    • 0346497613 scopus 로고    scopus 로고
    • Integrated sample preparation and MALDI mass spectrometry on a microfluidic compact disk
    • Gustafsson, M., Hirschberg, D., Palmberg, C., Jornvall, H., and Bergman, T. (2004) Integrated sample preparation and MALDI mass spectrometry on a microfluidic compact disk. Anal. Chem., 76: 345-350
    • (2004) Anal. Chem , vol.76 , pp. 345-350
    • Gustafsson, M.1    Hirschberg, D.2    Palmberg, C.3    Jornvall, H.4    Bergman, T.5
  • 95
    • 4043091975 scopus 로고    scopus 로고
    • Electrowetting-based microfluidics for analysis of peptides and proteins bymatrix-assisted laser desorption/ionization mass spectrometry
    • Wheeler, A.R., Moon, H., Kim, C.-J., Loo, J.A., and Garrell, R.L. (2004) Electrowetting-based microfluidics for analysis of peptides and proteins bymatrix-assisted laser desorption/ionization mass spectrometry. Anal. Chem., 76: 4833-4838
    • (2004) Anal. Chem , vol.76 , pp. 4833-4838
    • Wheeler, A.R.1    Moon, H.2    Kim, C.-J.3    Loo, J.A.4    Garrell, R.L.5
  • 96
    • 33747876882 scopus 로고    scopus 로고
    • An integrated digital microfluidic chip for multiplexed proteomic sample preparation and analysis by MALDI-MS
    • Moon, H., Wheeler, A.R., Garrell, R.L., Loo, J.A., and Kim, C.J. (2006) An integrated digital microfluidic chip for multiplexed proteomic sample preparation and analysis by MALDI-MS. Lab Chip, 6: 1213-1219
    • (2006) Lab Chip , vol.6 , pp. 1213-1219
    • Moon, H.1    Wheeler, A.R.2    Garrell, R.L.3    Loo, J.A.4    Kim, C.J.5
  • 97
    • 0034650858 scopus 로고    scopus 로고
    • Integrated microanalytical technology enabling rapid and automated protein identification
    • Ekstrom, S., Onnerfjord, P., Nilsson, J., Bengtsson, M., Laurell, T., and Marko-Varga, G. (2000) Integrated microanalytical technology enabling rapid and automated protein identification. Anal. Chem., 72, 286-293
    • (2000) Anal. Chem , vol.72 , pp. 286-293
    • Ekstrom, S.1    Onnerfjord, P.2    Nilsson, J.3    Bengtsson, M.4    Laurell, T.5    Marko-Varga, G.6
  • 98
    • 0034755602 scopus 로고    scopus 로고
    • Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption/ionization-time of flight-mass spectrometry: I. Microstructure development and manufacturing
    • DOI 10.1002/1522-2683(200110)22:18<3978::AID-ELPS3978>3.0.CO;2-7
    • Marko-Varga, G., Ekström, S., Helldin, G., Nilsson, J., and Laurell, T. (2001) Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption ionization-time-of-flight mass spectrometry: I. Microstructure development and manufacturing. Electrophoresis, 22: 3978-3983 (Pubitemid 33040217)
    • (2001) Electrophoresis , vol.22 , Issue.18 , pp. 3978-3983
    • Marko-Varga, G.1    Ekstrom, S.2    Helldin, G.3    Nilsson, J.4    Laurell, T.5
  • 99
    • 0034761614 scopus 로고    scopus 로고
    • Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption ionization-time-of-flight mass spectrometry: II
    • Ekström, S., Nilsson, J., Helldin, G., Laurell, T., and Marko-Varga, G. (2001) Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption ionization-time-of-flight mass spectrometry: II. Biological applications, Electrophoresis, 22: 3984-3992
    • (2001) Biological Applications, Electrophoresis , vol.22 , pp. 3984-3992
    • Ekström, S.1    Nilsson, J.2    Helldin, G.3    Laurell, T.4    Marko-Varga, G.5
  • 101
    • 33947284982 scopus 로고    scopus 로고
    • In-situ grafting hydrophilic polymer on chitosan modified poly (dimethylsiloxane) microchip for separation of biomolecules
    • Wang, A.J., Xu, J.J., and Chen, H.Y. (2007) In-situ grafting hydrophilic polymer on chitosan modified poly (dimethylsiloxane) microchip for separation of biomolecules. J. Chromatogr. A, 1147: 120-126
    • (2007) J. Chromatogr. A , vol.1147 , pp. 120-126
    • Wang, A.J.1    Xu, J.J.2    Chen, H.Y.3
  • 103
    • 33646423051 scopus 로고    scopus 로고
    • Designing polymer matrix for microchip-based double-stranded DNA capillary electrophoresis
    • Zhang, J., Weidong, H., Liang, D., Fang, D., Chu, B., and Marcus, G. (2006) Designing polymer matrix for microchip-based double-stranded DNA capillary electrophoresis. J. Chromatogr. A, 1117: 219-227
    • (2006) J. Chromatogr. A , vol.1117 , pp. 219-227
    • Zhang, J.1    Weidong, H.2    Liang, D.3    Fang, D.4    Chu, B.5    Marcus, G.6
  • 105
    • 33846966340 scopus 로고    scopus 로고
    • Multichannel microchip electrophoresis device fabricated in polycarbonate with an integrated contact conductivity sensor array
    • Shadpour, H., Hupert, M.L., Patterson, D., Liu, C., Galloway, M., Stryjewski, W., Goettert, J., and Steven, A.S. (2007) Multichannel microchip electrophoresis device fabricated in polycarbonate with an integrated contact conductivity sensor array. Anal. Chem., 79: 870-878
    • (2007) Anal. Chem , vol.79 , pp. 870-878
    • Shadpour, H.1    Hupert, M.L.2    Patterson, D.3    Liu, C.4    Galloway, M.5    Stryjewski, W.6    Goettert, J.7    Steven, A.S.8
  • 106
    • 29144485765 scopus 로고    scopus 로고
    • Ultrafast diagnosis of the genetic-related disorders using the combined technologies of multiplex PCR and multichannel microchip electrophoresis
    • Mohammad, J., Ashraf, A.E., Xu, F., Ping, G., Maged, F., Shinka, T., Nakahori, Y., Ishikawa, M., and Baba, Y. (2005) Ultrafast diagnosis of the genetic-related disorders using the combined technologies of multiplex PCR and multichannel microchip electrophoresis. Anal. Sci., 21: 1537-1539
    • (2005) Anal. Sci , vol.21 , pp. 1537-1539
    • Mohammad, J.1    Ashraf, A.E.2    Xu, F.3    Ping, G.4    Maged, F.5    Shinka, T.6    Nakahori, Y.7    Ishikawa, M.8    Baba, Y.9
  • 108
    • 38949160813 scopus 로고    scopus 로고
    • Ultra-fast detection and differentiation of Mycoplasma haemofelis and Candidatus M. Haemominutum in Korean feral cats by microchip electrophoresis with programmed field strength gradients
    • Kailasa, S.K., Lee, H.G., Yoo, D.J., and Kang, S.H. (2008) Ultra-fast detection and differentiation of Mycoplasma haemofelis and Candidatus M. Haemominutum in Korean feral cats by microchip electrophoresis with programmed field strength gradients. Bull. Korean Chem. Soc., 29: 153-158
    • (2008) Bull. Korean Chem. Soc , vol.29 , pp. 153-158
    • Kailasa, S.K.1    Lee, H.G.2    Yoo, D.J.3    Kang, S.H.4
  • 109
    • 39649116717 scopus 로고    scopus 로고
    • Microchip gel electrophoresis with programmed field strength gradients for ultra-fast detection of canine T-cell lymphoma in dogs
    • Kailasa, S.K., Lee, M. J., Park, J., and Kang, S.H. (2008) Microchip gel electrophoresis with programmed field strength gradients for ultra-fast detection of canine T-cell lymphoma in dogs. Talanta, 75: 49-55
    • (2008) Talanta , vol.75 , pp. 49-55
    • Kailasa, S.K.1    Lee, M.J.2    Park, J.3    Kang, S.H.4
  • 110
    • 44649144066 scopus 로고    scopus 로고
    • Ultrafast simultaneous detection of obesity-related coenzymes in mice using microchip electrophoresis with a LIF detector
    • Lee, H.G., Kumar, K.S., Soh, J.R., Cha, Y.S., and Kang, S.H. (2008) Ultrafast simultaneous detection of obesity-related coenzymes in mice using microchip electrophoresis with a LIF detector. Anal. Chim. Acta, 619: 94-100
    • (2008) Anal. Chim. Acta , vol.619 , pp. 94-100
    • Lee, H.G.1    Kumar, K.S.2    Soh, J.R.3    Cha, Y.S.4    Kang, S.H.5
  • 111
    • 3042699922 scopus 로고    scopus 로고
    • Influence of the pH on separating DNA by high-speed microchip electrophoresis
    • Osafune, T., Nagata, H., and Baba, Y. (2004) Influence of the pH on separating DNA by high-speed microchip electrophoresis. Anal. Sci., 20: 971-974
    • (2004) Anal. Sci , vol.20 , pp. 971-974
    • Osafune, T.1    Nagata, H.2    Baba, Y.3
  • 112
    • 0032524099 scopus 로고    scopus 로고
    • Chemical amplification: Continuous-flow PCR on a chip
    • Kopp, U.M., de Mello, A.J., and Manz, A. (1998) Chemical amplification: Continuous-flow PCR on a chip. Science, 280: 1046-1048
    • (1998) Science , vol.280 , pp. 1046-1048
    • Kopp, U.M.1    De Mello, A.J.2    Manz, A.3
  • 113
    • 13844275643 scopus 로고    scopus 로고
    • A triple-injection method for microchip electrophoresis
    • Tabuchi, M. and Baba, Y. (2005) A triple-injection method for microchip electrophoresis. Electrophoresis, 26: 376-382
    • (2005) Electrophoresis , vol.26 , pp. 376-382
    • Tabuchi, M.1    Baba, Y.2
  • 115
    • 34047271112 scopus 로고    scopus 로고
    • Microchip electrophoresis for detection of circle-to-circle amplification products towards sensitive and rapid DNA analysis
    • Laili, M., Melin, J., Mohamad, M. R., Yamada, K., Ohta, M., Kaji, N., Tokeshi, M., Nilsson, M., and Baba, Y. (2007) Microchip electrophoresis for detection of circle-to-circle amplification products towards sensitive and rapid DNA analysis. Chem. Lett., 36: 396-397
    • (2007) Chem. Lett , vol.36 , pp. 396-397
    • Laili, M.1    Melin, J.2    Mohamad, M.R.3    Yamada, K.4    Ohta, M.5    Kaji, N.6    Tokeshi, M.7    Nilsson, M.8    Baba, Y.9
  • 116
    • 70449624584 scopus 로고    scopus 로고
    • Sieving matrices for DNA separation in capillary electrophoreis and microchip electrophoresis
    • Huan, H. and Guohua, Z. (2006) Sieving matrices for DNA separation in capillary electrophoreis and microchip electrophoresis. Yaowu Fenxi Zazhi, 26: 138-143
    • (2006) Yaowu Fenxi Zazhi , vol.26 , pp. 138-143
    • Huan, H.1    Guohua, Z.2
  • 117
    • 33745714747 scopus 로고    scopus 로고
    • Self-associating block copolymer networks for microchip electrophoresis provide enhanced DNA separation via "inchworm" chain dynamics
    • Thomas, C.N., Karl, W.P., Meena, B., Patrick, M., Kashan, A. S., Edgar, G.D., Chang, L., and Anneliese, E.B. (2006) Self-associating block copolymer networks for microchip electrophoresis provide enhanced DNA separation via "Inchworm" chain dynamics. Anal. Chem., 78: 4409-4415
    • (2006) Anal. Chem , vol.78 , pp. 4409-4415
    • Thomas, C.N.1    Karl, W.P.2    Meena, B.3    Patrick, M.4    Kashan, A.S.5    Edgar, G.D.6    Chang, L.7    Anneliese, E.B.8
  • 118
    • 17644366157 scopus 로고    scopus 로고
    • Analysis of sources of error in quantitation of purified DNA fragments and unpurified PCR products by DNA microchip electrophoresis
    • Mohamadi, M.R., Kataoka, M., Mahmoudian, L., Jabasini, M., Shinohara, Y., and Baba, Y. (2005) Analysis of sources of error in quantitation of purified DNA fragments and unpurified PCR products by DNA microchip electrophoresis. Chromatographia, 61: 339-344
    • (2005) Chromatographia , vol.61 , pp. 339-344
    • Mohamadi, M.R.1    Kataoka, M.2    Mahmoudian, L.3    Jabasini, M.4    Shinohara, Y.5    Baba, Y.6
  • 119
    • 59349098838 scopus 로고    scopus 로고
    • Microfluidic device for integrated restriction digestion reaction and resulting DNA fragment analysis
    • Xie, H., Li, B., Zhong, R., Qin, J., Zhu, Y., and Lin, B. (2008) Microfluidic device for integrated restriction digestion reaction and resulting DNA fragment analysis. Electrophoresis, 29: 4956-4963
    • (2008) Electrophoresis , vol.29 , pp. 4956-4963
    • Xie, H.1    Li, B.2    Zhong, R.3    Qin, J.4    Zhu, Y.5    Lin, B.6
  • 120
    • 59449102688 scopus 로고    scopus 로고
    • A simple and sensitive transient ITP method for on-chip analysis of PCR samples
    • Wang, L., Liu, D., Chen, H., and Zhou, X. (2008) A simple and sensitive transient ITP method for on-chip analysis of PCR samples. Electrophoresis, 29: 4976-4983
    • (2008) Electrophoresis , vol.29 , pp. 4976-4983
    • Wang, L.1    Liu, D.2    Chen, H.3    Zhou, X.4
  • 121
    • 0035138104 scopus 로고    scopus 로고
    • Capillary and microchip electrophoresis for rapid detection of known mutations bycombining allele-specific DNA amplification with heteroduplex analysis
    • Tian, H., Brody, L. C., Fan, S., Huang, Z., Landers, J. P. (2001) Capillary and microchip electrophoresis for rapid detection of known mutations bycombining allele-specific DNA amplification with heteroduplex analysis. Clin. Chem., 47: 173-185
    • (2001) Clin. Chem , vol.47 , pp. 173-185
    • Tian, H.1    Brody, L.C.2    Fan, S.3    Huang, Z.4    Landers, J.P.5
  • 122
    • 0343656081 scopus 로고    scopus 로고
    • Rapid diagnosis of Herpes simplex encephalitis using microchip electrophoresis of PCR products
    • Hofgartner, T.W., Huhmer, F.R.A., Landers, P.J., and Kant, A.J. (1999) Rapid diagnosis of Herpes simplex encephalitis using microchip electrophoresis of PCR products. Clin. Chem., 45: 2120-2128
    • (1999) Clin. Chem , vol.45 , pp. 2120-2128
    • Hofgartner, T.W.1    Huhmer, F.R.A.2    Landers, P.J.3    Kant, A.J.4
  • 123
    • 0032733812 scopus 로고    scopus 로고
    • Plastic microchip electrophoresis for analysis of PCR products of Hepatitis C virus
    • Chen, Y.H., Wang, W.C., Young, K.C., Chang, T.T., and Chen, S.H. (1999) Plastic microchip electrophoresis for analysis of PCR products of Hepatitis C virus. Clin. Chem., 45: 1938-1943
    • (1999) Clin. Chem , vol.45 , pp. 1938-1943
    • Chen, Y.H.1    Wang, W.C.2    Young, K.C.3    Chang, T.T.4    Chen, S.H.5
  • 124
    • 0035041991 scopus 로고    scopus 로고
    • Plastic microchip electrophoresis for genetic screening: The analysis of polymerase chain reactions products of fragile X (CGG)n alleles
    • Sung, W.C., Lee, B.G., Tzeng, C.C., and Chen, S.H. (2001) Plastic microchip electrophoresis for genetic screening: The analysis of polymerase chain reactions products of fragile X (CGG)n alleles. Electrophoresis, 22: 1188-1193
    • (2001) Electrophoresis , vol.22 , pp. 1188-1193
    • Sung, W.C.1    Lee, B.G.2    Tzeng, C.C.3    Chen, S.H.4
  • 125
    • 0035288179 scopus 로고    scopus 로고
    • Exploiting sensitive laser-induced fluorescence detection on electrophoretic microchips for executing rapid clinical diagnostics
    • Ferrance, J. and Landers, J.P. (2001) Exploiting sensitive laser-induced fluorescence detection on electrophoretic microchips for executing rapid clinical diagnostics. Luminescence, 16: 79-88
    • (2001) Luminescence , vol.16 , pp. 79-88
    • Ferrance, J.1    Landers, J.P.2
  • 126
    • 0347764542 scopus 로고    scopus 로고
    • Evaluation of RNA messengers involved in lipid trafficking of human intestinal cells by reverse-transcription polymerase chain reaction with competimer technology and microchip electrophoresis
    • Cantafora, A., Blotta, I., Rivabene, R., Pisciotta, L., and Bertolini, S. (2003) Evaluation of RNA messengers involved in lipid trafficking of human intestinal cells by reverse-transcription polymerase chain reaction with competimer technology and microchip electrophoresis. Electrophoresis, 24: 3748-3754
    • (2003) Electrophoresis , vol.24 , pp. 3748-3754
    • Cantafora, A.1    Blotta, I.2    Rivabene, R.3    Pisciotta, L.4    Bertolini, S.5
  • 127
    • 3042772974 scopus 로고    scopus 로고
    • Capillary and microelectrophoretic separations of ligase detection reaction products produced from low-abundant point mutations in genomic DNA
    • Thomas, G., Sinville, R., Sutton, S., Farquar, H., Hammer, R.P., Soper, S.A., Cheng, Y. W., and Francis, B. (2004) Capillary and microelectrophoretic separations of ligase detection reaction products produced from low-abundant point mutations in genomic DNA. Electrophoresis, 25: 1668-1677
    • (2004) Electrophoresis , vol.25 , pp. 1668-1677
    • Thomas, G.1    Sinville, R.2    Sutton, S.3    Farquar, H.4    Hammer, R.P.5    Soper, S.A.6    Cheng, Y.W.7    Francis, B.8
  • 129
    • 0036207534 scopus 로고    scopus 로고
    • Detection of homocysteine by conventional and microchip capillary electrophoresis/ electrochemistry
    • Pasas, S.A., Lacher, N.A., Davies, M.I., and Lunte, S.M. (2002) Detection of homocysteine by conventional and microchip capillary electrophoresis/ electrochemistry. Electrophoresis, 23: 759-766
    • (2002) Electrophoresis , vol.23 , pp. 759-766
    • Pasas, S.A.1    Lacher, N.A.2    Davies, M.I.3    Lunte, S.M.4
  • 130
    • 0036535481 scopus 로고    scopus 로고
    • Analysis of lipoproteins by capillary zone electrophoresis in microfluidic devices: Assay development and surface roughness measurements
    • Weiller, B.H., Ceriotti, L., Shibata, T., Rein, D., Roberts, M. A., Lichtenberg, J., German, J.B., de Rooij, N.F., and Elisabeth, V. (2002) Analysis of lipoproteins by capillary zone electrophoresis in microfluidic devices: Assay development and surface roughness measurements. Anal. Chem., 74: 1702-1711
    • (2002) Anal. Chem , vol.74 , pp. 1702-1711
    • Weiller, B.H.1    Ceriotti, L.2    Shibata, T.3    Rein, D.4    Roberts, M.A.5    Lichtenberg, J.6    German, J.B.7    De Rooij, N.F.8    Elisabeth, V.9
  • 131
    • 4444349430 scopus 로고    scopus 로고
    • Detection of cariogenic bacterial genes by microchip electrophoresis
    • Karasawa, K., Arakawa, H., Igarashi, T., Goto, N., and Maeda, M. (2004) Detection of cariogenic bacterial genes by microchip electrophoresis. J. Chromatogr. B, 810: 41-44
    • (2004) J. Chromatogr. B , vol.810 , pp. 41-44
    • Karasawa, K.1    Arakawa, H.2    Igarashi, T.3    Goto, N.4    Maeda, M.5
  • 133
    • 0041837248 scopus 로고    scopus 로고
    • Integrating polymerase chain reaction, valving, and electrophoresis in a plastic device for bacterial detection
    • Koh, C.G., Tan, W., Zhao, M.Q., Ricco, A.J., and Fan, Z.H. (2003) Integrating polymerase chain reaction, valving, and electrophoresis in a plastic device for bacterial detection. Anal. Chem., 75: 4591-4598
    • (2003) Anal. Chem , vol.75 , pp. 4591-4598
    • Koh, C.G.1    Tan, W.2    Zhao, M.Q.3    Ricco, A.J.4    Fan, Z.H.5
  • 134
    • 0029989857 scopus 로고    scopus 로고
    • Functional integration of PCR amplification andcapillary electrophoresis in a microfabricated DNA analysis device
    • Woolley, A.T., Hadley, D., Landre, P., deMello, A.J., Mathies, R.A., and Northrup, M.A. (1996) Functional integration of PCR amplification andcapillary electrophoresis in a microfabricated DNA analysis device. Anal. Chem., 68: 4081-4086
    • (1996) Anal. Chem , vol.68 , pp. 4081-4086
    • Woolley, A.T.1    Hadley, D.2    Landre, P.3    Demello, A.J.4    Mathies, R.A.5    Northrup, M.A.6
  • 137
    • 0037437664 scopus 로고    scopus 로고
    • Detection of bacterial pathogen DNA using an integrated complementary metal oxide semiconductor microchip with capillary array electrophoresis
    • Song, J.M., Mobley, J., and Tuan, V.D. (2003) Detection of bacterial pathogen DNA using an integrated complementary metal oxide semiconductor microchip with capillary array electrophoresis. J. Chromatogr. B, 783: 501-508
    • (2003) J. Chromatogr. B , vol.783 , pp. 501-508
    • Song, J.M.1    Mobley, J.2    Tuan, V.D.3
  • 138
    • 3042698127 scopus 로고    scopus 로고
    • Capillary electrophoresis chips with a sheath-flow supported electrochemical detection system
    • Ertl, P., Emrich, C.A., Singhal, P., and Mathies, R.A. (2004) Capillary electrophoresis chips with a sheath-flow supported electrochemical detection system. Anal. Chem., 76: 3749-3755
    • (2004) Anal. Chem , vol.76 , pp. 3749-3755
    • Ertl, P.1    Emrich, C.A.2    Singhal, P.3    Mathies, R.A.4
  • 140
  • 141
    • 0036909374 scopus 로고    scopus 로고
    • A simple PDMS-based electro-fluidic interface for microchip electrophoretic separations
    • Sanders, J.C., Breadmore, M.C., Mitchell, P.S., and Landers, J.P. (2002) A simple PDMS-based electro-fluidic interface for microchip electrophoretic separations. Analyst, 127: 1558-1563
    • (2002) Analyst , vol.127 , pp. 1558-1563
    • Sanders, J.C.1    Breadmore, M.C.2    Mitchell, P.S.3    Landers, J.P.4
  • 142
    • 0036156065 scopus 로고    scopus 로고
    • Evaluation of microchip electrophoresis as a molecular diagnostic method for Duchenne muscular dystrophy
    • Ferrance, J., Snow, K., and Landers, J.P. (2002) Evaluation of microchip electrophoresis as a molecular diagnostic method for Duchenne muscular dystrophy. Clin. Chem., 48: 380-383
    • (2002) Clin. Chem , vol.48 , pp. 380-383
    • Ferrance, J.1    Snow, K.2    Landers, J.P.3
  • 143
    • 34248576770 scopus 로고    scopus 로고
    • Microchip electrophoresis coupled with multiplex polymerase chain reaction for typing multiple single nucleotide polymorphisms simultaneously
    • Wang, W., Ni, K., and Zhou, G. (2006) Microchip electrophoresis coupled with multiplex polymerase chain reaction for typing multiple single nucleotide polymorphisms simultaneously. Fenxi Huaxue, 34: 1389-1394
    • (2006) Fenxi Huaxue , vol.34 , pp. 1389-1394
    • Wang, W.1    Ni, K.2    Zhou, G.3
  • 144
    • 70449673998 scopus 로고    scopus 로고
    • Non-invasive detection of fetal gentics traits by analyzing extracellular DNAs in blood samples
    • (EP 1524321)
    • Sinuhe, H., Bernhard, Z., Wolfgang, H., and Ying, L. (2005) Non-invasive detection of fetal gentics traits by analyzing extracellular DNAs in blood samples, Eur. Pat. Appl., (EP 1524321), p. 9-9
    • (2005) Eur. Pat. Appl. , pp. 9-9
    • Sinuhe, H.1    Bernhard, Z.2    Wolfgang, H.3    Ying, L.4
  • 145
    • 4644339362 scopus 로고    scopus 로고
    • Single-step quantitation of DNA in microchip electrophoresis with linear imaging UV detection and fluorescence detection through co-migration with a digest
    • Feng, X., Mohammad, J., Bingmei, Z., Ling, Y., Xuezhi, C., Ahihiro, A., and Baba, Y. (2004) Single-step quantitation of DNA in microchip electrophoresis with linear imaging UV detection and fluorescence detection through co-migration with a digest, J. Chromatogr. A, 1051: 147-153
    • (2004) J. Chromatogr. A , vol.1051 , pp. 147-153
    • Feng, X.1    Mohammad, J.2    Bingmei, Z.3    Ling, Y.4    Xuezhi, C.5    Ahihiro, A.6    Baba, Y.7
  • 146
    • 0032754872 scopus 로고    scopus 로고
    • Molecular diagnostics on microfabricated electrophoretic devices: From slab gel to capillary to microchip based assays for T-and B-cell lymphoproliferative disorders
    • Munro, J.N., Snow, K., Kant, A.J., and Landers, P.J. (1999) Molecular diagnostics on microfabricated electrophoretic devices: From slab gel to capillary to microchip based assays for T-and B-cell lymphoproliferative disorders. Clin. Chem., 45: 1906-1917
    • (1999) Clin. Chem , vol.45 , pp. 1906-1917
    • Munro, J.N.1    Snow, K.2    Kant, A.J.3    Landers, P.J.4
  • 148
    • 59349086935 scopus 로고    scopus 로고
    • Microchip assays for screening monoclonal antibody product quality
    • Chen, X., Tang, K., Lee, M., and Flynn, G.C. (2008) Microchip assays for screening monoclonal antibody product quality. Electrophoresis, 29: 4993-5002
    • (2008) Electrophoresis , vol.29 , pp. 4993-5002
    • Chen, X.1    Tang, K.2    Lee, M.3    Flynn, G.C.4
  • 149
    • 59349116250 scopus 로고    scopus 로고
    • Rapid chip-based capillary electrophoretic mobility shift assay with negative pressure injection for the binding study of transcription factor Abf1 in Saccharomyces cerevisiae
    • Yang, Q., Zhao, Y.C., Xiong, Q., and Cheng, J. (2008) Rapid chip-based capillary electrophoretic mobility shift assay with negative pressure injection for the binding study of transcription factor Abf1 in Saccharomyces cerevisiae. Electrophoresis, 29: 5003-5009
    • (2008) Electrophoresis , vol.29 , pp. 5003-5009
    • Yang, Q.1    Zhao, Y.C.2    Xiong, Q.3    Cheng, J.4
  • 150
    • 59349092389 scopus 로고    scopus 로고
    • Internally calibrated quantification of protein analytes in human serum by fluorescence immunoassays in disposable elastomeric microfluidic devices
    • Kartalov, E.P., Lin, H.D., Lee, T.D., Anderson, F.W., Taylor, R.C., and Scherer, A. (2008) Internally calibrated quantification of protein analytes in human serum by fluorescence immunoassays in disposable elastomeric microfluidic devices. Electrophoresis, 29: 5010-5016
    • (2008) Electrophoresis , vol.29 , pp. 5010-5016
    • Kartalov, E.P.1    Lin, H.D.2    Lee, T.D.3    Anderson, F.W.4    Taylor, R.C.5    Scherer, A.6
  • 151
    • 59349102130 scopus 로고    scopus 로고
    • Simple, fast and high-throughput single-cell analysis on PDMS microfluidic chips
    • Yu, L., Huang, H., Dong, X., Wu, D., Qin, J., and Lin, B. (2008) Simple, fast and high-throughput single-cell analysis on PDMS microfluidic chips. Electrophoresis, 29, 5055-5060
    • (2008) Electrophoresis , vol.29 , pp. 5055-5060
    • Yu, L.1    Huang, H.2    Dong, X.3    Wu, D.4    Qin, J.5    Lin, B.6
  • 153
    • 65549160441 scopus 로고    scopus 로고
    • Determination of foodborne pathogenic bacteria by multiplex PCR-microchip capillary electrophoresis with genetic algorithm-support vector regression optimization
    • Li, Y., Li, Y., Zheng, B., Qu, L., and Li. C. (2009) Determination of foodborne pathogenic bacteria by multiplex PCR-microchip capillary electrophoresis with genetic algorithm-support vector regression optimization. Anal. Chim. Acta, 643: 100-107
    • (2009) Anal. Chim. Acta , vol.643 , pp. 100-107
    • Li, Y.1    Li, Y.2    Zheng, B.3    Qu, L.4    Li, C.5
  • 154
    • 65949087674 scopus 로고    scopus 로고
    • Dispersion of protein bands in a horseshoe microchannel during IEF
    • Shim, J., Dutta, P., and Ivory, F.C. (2009) Dispersion of protein bands in a horseshoe microchannel during IEF. Electrophoresis, 30: 723-731
    • (2009) Electrophoresis , vol.30 , pp. 723-731
    • Shim, J.1    Dutta, P.2    Ivory, F.C.3
  • 155
    • 65349177046 scopus 로고    scopus 로고
    • Estimation of allele frequency in pooled DNA by using PCR-RFLP combined with microchip electrophoresis
    • Wang, W.P., Zhang, R.H., Wu, P., Wang, S., and Li, R. (2009) Estimation of allele frequency in pooled DNA by using PCR-RFLP combined with microchip electrophoresis. J. Chromatogr. B, 877: 1603-1606
    • (2009) J. Chromatogr. B , vol.877 , pp. 1603-1606
    • Wang, W.P.1    Zhang, R.H.2    Wu, P.3    Wang, S.4    Li, R.5
  • 156
    • 59349096698 scopus 로고    scopus 로고
    • Generating high peak capacity 2-D maps of complex proteomes using PMMA microchip electrophoresis
    • Osiri, J.K., Shadpour, H., Park, S., Snowden, B.C., Chen, Z.Y., and Soper, S.A. (2008) Generating high peak capacity 2-D maps of complex proteomes using PMMA microchip electrophoresis. Electrophoresis, 29, 4984-4992
    • (2008) Electrophoresis , vol.29 , pp. 4984-4992
    • Osiri, J.K.1    Shadpour, H.2    Park, S.3    Snowden, B.C.4    Chen, Z.Y.5    Soper, S.A.6
  • 157
    • 59349108167 scopus 로고    scopus 로고
    • Miniaturized electrochemical detector as a tool for detection of DNA amplified by PCR
    • Huska, D., Hubalek, J., Adam, V., and Kizek, R. (2008) Miniaturized electrochemical detector as a tool for detection of DNA amplified by PCR. Electrophoresis, 29: 4964-4971
    • (2008) Electrophoresis , vol.29 , pp. 4964-4971
    • Huska, D.1    Hubalek, J.2    Adam, V.3    Kizek, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.