Volumn 16, Issue 2, 2008, Pages 67-88

A practical reconstruction method for dual energy computed tomography

Author keywords

Basis material decomposition; Dual energy computed tomography; Effective atomic number; Spectrum estimation

Indexed keywords

ATOMS; COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC RADIOGRAPHY; IMAGE PROCESSING; IMAGE RECONSTRUCTION; MEDICAL IMAGING; REPAIR; RESTORATION; THERMOGRAPHY (TEMPERATURE MEASUREMENT); TOMOGRAPHY;

EID: 48249089664     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (73)

References (58)
  • 1
    • 0025433902 scopus 로고
    • Review of dual-energy computed tomography techniques
    • P. Engler and W.D. Friedman, Review of dual-energy computed tomography techniques, Materials Evaluation 48(5) (1990), 623-629.
    • (1990) Materials Evaluation , vol.48 , Issue.5 , pp. 623-629
    • Engler, P.1    Friedman, W.D.2
  • 2
    • 1642380221 scopus 로고    scopus 로고
    • Comparison of dual energy detector system performance
    • R.E. Alvarez, J.A. Seibert and S.K. Thompson, Comparison of dual energy detector system performance, Med Phys 31(3) (2004), 556-565.
    • (2004) Med Phys , vol.31 , Issue.3 , pp. 556-565
    • Alvarez, R.E.1    Seibert, J.A.2    Thompson, S.K.3
  • 3
    • 0021195789 scopus 로고
    • Discrimination between thorotrast and iodine contrast medium by means of dual-energy CT scanning
    • M. Takai and M. Kaneko, Discrimination between thorotrast and iodine contrast medium by means of dual-energy CT scanning, Phys Med Biol 29(8) (1984), 959-967.
    • (1984) Phys Med Biol , vol.29 , Issue.8 , pp. 959-967
    • Takai, M.1    Kaneko, M.2
  • 4
    • 0023102408 scopus 로고
    • Systematic errors inbone-mineral measurements byquantitative computed tomography
    • G.U. Rao, I.Yaghmai, A.O. Wist and G.Arora, Systematic errors inbone-mineral measurements byquantitative computed tomography, Med Phys 14(1) (1987), 62-69.
    • (1987) Med Phys , vol.14 , Issue.1 , pp. 62-69
    • Rao, G.U.1    Yaghmai, I.2    Wist, A.O.3    Arora, G.4
  • 5
    • 0026621616 scopus 로고
    • Prototype of dual energy X-ray tomodensimeter for lumbar spine bone mineral density measurements: Choice of the reconstruction algorithm and first experimental results
    • P.-O. Kotzi, D. Mariano-Goulart and M. Rossi, Prototype of dual energy X-ray tomodensimeter for lumbar spine bone mineral density measurements: choice of the reconstruction algorithm and first experimental results, Phys Med Biol 37(12) (1992), 2253-2265.
    • (1992) Phys Med Biol , vol.37 , Issue.12 , pp. 2253-2265
    • Kotzi, P.-O.1    Mariano-Goulart, D.2    Rossi, M.3
  • 6
    • 0029743578 scopus 로고    scopus 로고
    • in situ measurement of iron overload in liver tissue by dual-energy methods
    • S. Oelckers and W. Graeff, in situ measurement of iron overload in liver tissue by dual-energy methods, Phys Med Biol 41(7) (1996), 1149-1165.
    • (1996) Phys Med Biol , vol.41 , Issue.7 , pp. 1149-1165
    • Oelckers, S.1    Graeff, W.2
  • 7
    • 0022407220 scopus 로고
    • A beam-hardening correction using dual-energy computed. tomography
    • A.J. Coleman and M. Sinclair, A beam-hardening correction using dual-energy computed. tomography, Phys Med Biol 30(11) (1985), 1251-1256.
    • (1985) Phys Med Biol , vol.30 , Issue.11 , pp. 1251-1256
    • Coleman, A.J.1    Sinclair, M.2
  • 8
    • 3042824019 scopus 로고    scopus 로고
    • Impact of polychromatic X-ray sources on helical, cone-beam computed tomography and dual-energy methods
    • E.Y. Sidky, Y. Zou and X. Pan, Impact of polychromatic X-ray sources on helical, cone-beam computed tomography and dual-energy methods, Phys Med Biol 49(11) (2004), 2293-2303.
    • (2004) Phys Med Biol , vol.49 , Issue.11 , pp. 2293-2303
    • Sidky, E.Y.1    Zou, Y.2    Pan, X.3
  • 9
    • 33748033063 scopus 로고    scopus 로고
    • Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging
    • P.E. Kinahan, A.M. Alessio and J.A. Fessler, Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging, TECHNOL CANCER RES T 5(4) (2006), 319-327.
    • (2006) TECHNOL CANCER RES T , vol.5 , Issue.4 , pp. 319-327
    • Kinahan, P.E.1    Alessio, A.M.2    Fessler, J.A.3
  • 10
    • 16444381711 scopus 로고    scopus 로고
    • Application of conventional- and dual-energy X-ray tomography in process engineering
    • S. Gehrke and K. Wirth, Application of conventional- and dual-energy X-ray tomography in process engineering, IEEE SENS J 5(2) (2005), 183-187.
    • (2005) IEEE SENS J , vol.5 , Issue.2 , pp. 183-187
    • Gehrke, S.1    Wirth, K.2
  • 13
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in X-ray Computerized Tomography
    • R. Alvarez and A. Macovski, Energy-selective reconstructions in X-ray Computerized Tomography, Phys Med Biol 21(5) (1976), 733-744.
    • (1976) Phys Med Biol , vol.21 , Issue.5 , pp. 733-744
    • Alvarez, R.1    Macovski, A.2
  • 14
    • 0022528983 scopus 로고
    • Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
    • W.A. Kalender, W.H. Perman, J.R. Vetter and E. Klotz, Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies, Med Phys 13(3) (1986), 334-339.
    • (1986) Med Phys , vol.13 , Issue.3 , pp. 334-339
    • Kalender, W.A.1    Perman, W.H.2    Vetter, J.R.3    Klotz, E.4
  • 15
    • 0019389495 scopus 로고
    • Generalized image combinations in dual KVP digital radiography
    • L.A. Lehmann, R.E. Alvarez, A. Macovske, W.R. Brody and etc., Generalized image combinations in dual KVP digital radiography, Med Phys 8(5) (1981), 659-667.
    • (1981) Med Phys , vol.8 , Issue.5 , pp. 659-667
    • Lehmann, L.A.1    Alvarez, R.E.2    Macovske, A.3    Brody, W.R.4    and etc5
  • 16
    • 0023185657 scopus 로고
    • A fast dual-energy computational method using iso-transmission lines and table lookup
    • K.S. Chuang and H.K. Huang, A fast dual-energy computational method using iso-transmission lines and table lookup, Med Phys 14(2) (1987), 186-192.
    • (1987) Med Phys , vol.14 , Issue.2 , pp. 186-192
    • Chuang, K.S.1    Huang, H.K.2
  • 18
    • 0025324060 scopus 로고
    • An accurate method for direct dual-energy calibration and decomposition
    • H.N. Cardinal and A. Fenster, An accurate method for direct dual-energy calibration and decomposition, Med Phys 17(3) (1990), 327-341.
    • (1990) Med Phys , vol.17 , Issue.3 , pp. 327-341
    • Cardinal, H.N.1    Fenster, A.2
  • 19
    • 0026002868 scopus 로고
    • Analytic approximation of the log-signal and log-variance functions of X-ray imaging systems, with application to dual-energy imaging
    • H.N. Cardinal and A. Fenster, Analytic approximation of the log-signal and log-variance functions of X-ray imaging systems, with application to dual-energy imaging, Med Phys 18(5) (1991), 867-879.
    • (1991) Med Phys , vol.18 , Issue.5 , pp. 867-879
    • Cardinal, H.N.1    Fenster, A.2
  • 22
    • 34548299710 scopus 로고    scopus 로고
    • Empirical dual energy calibration (EDEC) for cone-beam computed tomography
    • P.Stenner, T. Berkus and M. Kachelrieß, Empirical dual energy calibration (EDEC) for cone-beam computed tomography, Med Phys 34(9) (2007), 3630-3641.
    • (2007) Med Phys , vol.34 , Issue.9 , pp. 3630-3641
    • Stenner, P.1    Berkus, T.2    Kachelrieß, M.3
  • 23
    • 0021715676 scopus 로고
    • Exact treatment of the dual-energy method in CT using polyenergetic X-ray spectra
    • G. Christ, Exact treatment of the dual-energy method in CT using polyenergetic X-ray spectra, Phys Med Biol 29(12) (1984), 1501-1510.
    • (1984) Phys Med Biol , vol.29 , Issue.12 , pp. 1501-1510
    • Christ, G.1
  • 24
    • 0026697397 scopus 로고
    • Selection of fat-equivalent materials in postprocessing dual-energy quantitative CT
    • J.C.M. Steenbeek, C. van Kuijk, J.L. Grashuis and R.B. Eck, Selection of fat-equivalent materials in postprocessing dual-energy quantitative CT, Med Phys 19(4) (1992), 1051-1056.
    • (1992) Med Phys , vol.19 , Issue.4 , pp. 1051-1056
    • Steenbeek, J.C.M.1    van Kuijk, C.2    Grashuis, J.L.3    Eck, R.B.4
  • 25
    • 0026671575 scopus 로고
    • Precision in quantitative CT: Impact of X-ray dose and matrix size
    • M.M. Goodsitt and R.H. Johnson, Precision in quantitative CT: impact of X-ray dose and matrix size, Med Phys 19(4) (1992), 1025-1036.
    • (1992) Med Phys , vol.19 , Issue.4 , pp. 1025-1036
    • Goodsitt, M.M.1    Johnson, R.H.2
  • 26
    • 0029115573 scopus 로고
    • Beam hardening errors in post-processing dual energy quantitative computed tomography
    • M.M. Goodsitt, Beam hardening errors in post-processing dual energy quantitative computed tomography, Med Phys 22(7) (1995), 1039-1047.
    • (1995) Med Phys , vol.22 , Issue.7 , pp. 1039-1047
    • Goodsitt, M.M.1
  • 27
    • 0042510909 scopus 로고    scopus 로고
    • Density and atomic number measurements with spectral X-ray attenuation method
    • B.J. Heismann, J. Leppert and K. Stierstorfer, Density and atomic number measurements with spectral X-ray attenuation method, J Appl Phys 94(3) (2003), 2073-2079.
    • (2003) J Appl Phys , vol.94 , Issue.3 , pp. 2073-2079
    • Heismann, B.J.1    Leppert, J.2    Stierstorfer, K.3
  • 29
    • 0034310513 scopus 로고    scopus 로고
    • Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
    • P. Sukovic and N.H. Clinthorne, Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography, IEEE Trans Med Imag 19(11) (2000), 1075-1081.
    • (2000) IEEE Trans Med Imag , vol.19 , Issue.11 , pp. 1075-1081
    • Sukovic, P.1    Clinthorne, N.H.2
  • 30
    • 0037423924 scopus 로고    scopus 로고
    • Electron density measurement with dual-energy X-ray CT using synchrotron radiation
    • M. Torikoshi, T. Tsunoo, M. Sasaki, M. Endo, Y. Noda, Y. Ohno and etc., Electron density measurement with dual-energy X-ray CT using synchrotron radiation, Phys Med Biol 48(5) (2003), 673-685.
    • (2003) Phys Med Biol , vol.48 , Issue.5 , pp. 673-685
    • Torikoshi, M.1    Tsunoo, T.2    Sasaki, M.3    Endo, M.4    Noda, Y.5    Ohno, Y.6    and etc7
  • 35
    • 0032096112 scopus 로고    scopus 로고
    • X-ray dual-energy calibration based on estimated spectral properties of the experimental system
    • U. Hassler, L. Garnero and P. Rio, X-ray dual-energy calibration based on estimated spectral properties of the experimental system, IEEE Trans Nucl Sci 45(3) (1998), 1699-1712.
    • (1998) IEEE Trans Nucl Sci , vol.45 , Issue.3 , pp. 1699-1712
    • Hassler, U.1    Garnero, L.2    Rio, P.3
  • 36
    • 0016819212 scopus 로고
    • Photon attenuation in computed tomography
    • E.C. McCullough, Photon attenuation in computed tomography, Med Phys 2(6) (1975), 307-320.
    • (1975) Med Phys , vol.2 , Issue.6 , pp. 307-320
    • McCullough, E.C.1
  • 37
    • 8544232177 scopus 로고    scopus 로고
    • Effective atomic numbers of composite materials for total and partial interaction processes for photons, electrons, and protons
    • S.G. Prasad, K. Parthasaradhi and W.D. Bloomer, Effective atomic numbers of composite materials for total and partial interaction processes for photons, electrons, and protons, Med Phys 24(6) (1997), 883-885.
    • (1997) Med Phys , vol.24 , Issue.6 , pp. 883-885
    • Prasad, S.G.1    Parthasaradhi, K.2    Bloomer, W.D.3
  • 38
    • 0023612391 scopus 로고
    • Effective atomic numbers for low-energy total photon interactions in human tissues
    • N.C. Yang, P.K. Leichner and W.G. Hawkins, Effective atomic numbers for low-energy total photon interactions in human tissues, Med Phys 14(5) (1987), 759-766.
    • (1987) Med Phys , vol.14 , Issue.5 , pp. 759-766
    • Yang, N.C.1    Leichner, P.K.2    Hawkins, W.G.3
  • 41
    • 48249120192 scopus 로고    scopus 로고
    • W.H. Press, B.P. Flannery and S.A. Teukolsky, Numerical Recipes in C, Cambridge University Press, Cambridge, 1988.
    • W.H. Press, B.P. Flannery and S.A. Teukolsky, Numerical Recipes in C, Cambridge University Press, Cambridge, 1988.
  • 42
    • 35148866301 scopus 로고    scopus 로고
    • Noise transfer analysis of base material decomposition methods
    • B.J. Heismann, Noise transfer analysis of base material decomposition methods, in proceedings of SPIE Medical Imaging 6510 (2007), 651011.
    • (2007) proceedings of SPIE Medical Imaging , vol.6510 , pp. 651011
    • Heismann, B.J.1
  • 43
    • 0006064254 scopus 로고
    • Determination of the spectral composition of X-ray radiation from filtration data
    • L. Silberstein, Determination of the spectral composition of X-ray radiation from filtration data, J Opt Soc Am 22 (1932), 265-280.
    • (1932) J Opt Soc Am , vol.22 , pp. 265-280
    • Silberstein, L.1
  • 44
    • 21144445512 scopus 로고    scopus 로고
    • Assessment of different computational models for generation of X-ray spectra in diagnostic radiology and mammography
    • M.R. Ay, S. Sarkar, M. Shahriari, D. Sardari and H. Zaidi, Assessment of different computational models for generation of X-ray spectra in diagnostic radiology and mammography, Med Phys 32(6) (2005), 1660-1675,.
    • (2005) Med Phys , vol.32 , Issue.6 , pp. 1660-1675
    • Ay, M.R.1    Sarkar, S.2    Shahriari, M.3    Sardari, D.4    Zaidi, H.5
  • 45
    • 0030919839 scopus 로고    scopus 로고
    • Estimation of a photon energy spectrum for a computed tomography scanner
    • C. Ruth and P.M. Joseph, Estimation of a photon energy spectrum for a computed tomography scanner, Med Phys 24(5) (1997), 695-702.
    • (1997) Med Phys , vol.24 , Issue.5 , pp. 695-702
    • Ruth, C.1    Joseph, P.M.2
  • 46
    • 0032767841 scopus 로고    scopus 로고
    • X-ray spectra estimation using attenuation measurements from 25kVp to 18MV
    • R.G. Waggener, M.M. Blough, J.A. Terry and etc., X-ray spectra estimation using attenuation measurements from 25kVp to 18MV, Med Phys 26(7) (1999), 1269-1278.
    • (1999) Med Phys , vol.26 , Issue.7 , pp. 1269-1278
    • Waggener, R.G.1    Blough, M.M.2    Terry, J.A.3    and etc4
  • 47
    • 33750545592 scopus 로고    scopus 로고
    • Characteristic features of a high-energy X-ray spectra estimation method based on the Waggener iterative perturbation principle
    • A. Iwasaki, M. Kubota and J. Hirota, Characteristic features of a high-energy X-ray spectra estimation method based on the Waggener iterative perturbation principle, Med Phys 33(11) (2006), 4056-4063.
    • (2006) Med Phys , vol.33 , Issue.11 , pp. 4056-4063
    • Iwasaki, A.1    Kubota, M.2    Hirota, J.3
  • 48
    • 33847667857 scopus 로고    scopus 로고
    • Determination of X-ray spectra from attenuation data by imposing a priori positiveness and bounded support: Theory and experimental validation
    • V. Delgado, Determination of X-ray spectra from attenuation data by imposing a priori positiveness and bounded support: Theory and experimental validation, Med Phys 34(3) (2007), 994-1006.
    • (2007) Med Phys , vol.34 , Issue.3 , pp. 994-1006
    • Delgado, V.1
  • 49
    • 21644449154 scopus 로고    scopus 로고
    • A robust method ofX-ray source spectrum estimation from transmission measurements: Demonstrated on computer simulated, scatter-free transmission data
    • E.Y. Sidky, L. Yu, X. Pan, Y.Zou and M. Vannier, A robust method ofX-ray source spectrum estimation from transmission measurements: Demonstrated on computer simulated, scatter-free transmission data, J Appl Phys 97 (2005), 124701.
    • (2005) J Appl Phys , vol.97 , pp. 124701
    • Sidky, E.Y.1    Yu, L.2    Pan, X.3    Zou, Y.4    Vannier, M.5
  • 50
    • 33748300890 scopus 로고    scopus 로고
    • Properties of preprocessed sinogram data in X-ray computed tomography
    • B.R. Whiting, P.Massoumzadeh and O.A. Earl, Properties of preprocessed sinogram data in X-ray computed tomography, Med Phys 33(9) (2006), 3290-3303.
    • (2006) Med Phys , vol.33 , Issue.9 , pp. 3290-3303
    • Whiting, B.R.1    Massoumzadeh, P.2    Earl, O.A.3
  • 52
    • 0036462553 scopus 로고    scopus 로고
    • Statistical image reconstruction for polyenergetic X-ray computed tomography
    • I.A. Elbakri and J.A. Fessler, Statistical image reconstruction for polyenergetic X-ray computed tomography, IEEE Trans Med Imag 21(2) (2002), 89-99.
    • (2002) IEEE Trans Med Imag , vol.21 , Issue.2 , pp. 89-99
    • Elbakri, I.A.1    Fessler, J.A.2
  • 53
    • 34147138229 scopus 로고    scopus 로고
    • Statistical reconstruction for X-ray computed tomography using energyintegrating detectors
    • G.M. Lasio, B.R. Whiting and J.F. Williamson, Statistical reconstruction for X-ray computed tomography using energyintegrating detectors, Phys Med Biol 52(8) (2007), 2247-2266.
    • (2007) Phys Med Biol , vol.52 , Issue.8 , pp. 2247-2266
    • Lasio, G.M.1    Whiting, B.R.2    Williamson, J.F.3
  • 54
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R.Carson, EM reconstruction algorithms for emission and transmission tomography, J Comp Assist Tomogr 8(2) (1984), 306-316.
    • (1984) J Comp Assist Tomogr , vol.8 , Issue.2 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 55
    • 0031120191 scopus 로고    scopus 로고
    • Energy-dependent systematic errors in dual-energy X-ray CT
    • K.L. Goh, S.C. Liew and B.H. Hasegawa, Energy-dependent systematic errors in dual-energy X-ray CT, IEEE Trans Nucl Sci 44(2) (1997), 212-217.
    • (1997) IEEE Trans Nucl Sci , vol.44 , Issue.2 , pp. 212-217
    • Goh, K.L.1    Liew, S.C.2    Hasegawa, B.H.3
  • 56
    • 0031342908 scopus 로고    scopus 로고
    • Correction of energy-dependent systematic errors in dual-energy X-ray CT using a basis material coefficients transformation method
    • K.L. Goh, S.C. Liew and B.H. Hasegawa, Correction of energy-dependent systematic errors in dual-energy X-ray CT using a basis material coefficients transformation method, IEEE Trans Nucl Sci 44(6) (1997), 2419-2424.
    • (1997) IEEE Trans Nucl Sci , vol.44 , Issue.6 , pp. 2419-2424
    • Goh, K.L.1    Liew, S.C.2    Hasegawa, B.H.3
  • 57
    • 0023771636 scopus 로고
    • Correction for scattered radiation and other background signals in dual-energy computed tomography material thickness measurements
    • J.R. Vetter and J.E. Holden, Correction for scattered radiation and other background signals in dual-energy computed tomography material thickness measurements, Med Phys 15(5) (1988), 726-731.
    • (1988) Med Phys , vol.15 , Issue.5 , pp. 726-731
    • Vetter, J.R.1    Holden, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.