메뉴 건너뛰기




Volumn 52, Issue 8, 2007, Pages 2247-2266

Statistical reconstruction for x-ray computed tomography using energy-integrating detectors

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTERIZED TOMOGRAPHY; MATHEMATICAL MODELS; PHOTONS; POISSON DISTRIBUTION; STATISTICAL METHODS;

EID: 34147138229     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/8/014     Document Type: Article
Times cited : (75)

References (23)
  • 2
    • 0018399326 scopus 로고
    • Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector
    • Birch R and Marshall M 1979 Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector Phys. Med. Biol. 24 505-17
    • (1979) Phys. Med. Biol. , vol.24 , Issue.3 , pp. 505-517
    • Birch, R.1    Marshall, M.2
  • 3
    • 0033461146 scopus 로고    scopus 로고
    • Detective quantum efficiency dependence on x-ray energy weighting in mammography
    • Cahn R N, Cederstrom B, Danielsson M, Hall A, Lundqvist M and Nygren D 1999 Detective quantum efficiency dependence on x-ray energy weighting in mammography Med. Phys. 26 2680-3
    • (1999) Med. Phys. , vol.26 , Issue.12 , pp. 2680-2683
    • Cahn, R.N.1    Cederstrom, B.2    Danielsson, M.3    Hall, A.4    Lundqvist, M.5    Nygren, D.6
  • 8
    • 0042977266 scopus 로고    scopus 로고
    • Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation
    • Elbakri I A and Fessler J A 2003b Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation Phys. Med. Biol. 48 2453-77
    • (2003) Phys. Med. Biol. , vol.48 , Issue.15 , pp. 2453-2477
    • Elbakri, I.A.1    Fessler, J.A.2
  • 10
    • 0002638197 scopus 로고    scopus 로고
    • Statistical imaging reconstruction methods
    • Fessler J A 2000 Statistical imaging reconstruction methods Handbook of Medical Imaging (Washington, DC: SPIE)
    • (2000) Handbook of Medical Imaging
    • Fessler, J.A.1
  • 12
    • 0018877798 scopus 로고
    • Signal variance in computed tomography: The square root of N syndrome
    • Gore J C and Mccullough E C 1980 Signal variance in computed tomography: the square root of N syndrome Phys. Med. Biol. 25 153-5
    • (1980) Phys. Med. Biol. , vol.25 , Issue.1 , pp. 153-155
    • Gore, J.C.1    McCullough, E.C.2
  • 13
    • 0034257871 scopus 로고    scopus 로고
    • Investigation of a solid-state detector for advanced computed tomography
    • Hsieh J, Gurmen O E and King K F 2000 Investigation of a solid-state detector for advanced computed tomography IEEE Trans. Med. Imaging 19 930-40
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.9 , pp. 930-940
    • Hsieh, J.1    Gurmen, O.E.2    King, K.F.3
  • 15
    • 0022083110 scopus 로고
    • Ein programm für die berechnung von diagnostischen röntgenspektren
    • Nowotny R and Höfer A 1985 Ein programm für die berechnung von diagnostischen röntgenspektren Fortschr. Röntgenstr. 142 685-9
    • (1985) Fortschr. Röntgenstr. , vol.142 , pp. 685-689
    • Nowotny, R.1    Höfer, A.2
  • 17
    • 34147157049 scopus 로고    scopus 로고
    • Politte D G and Whiting B 2002 A fast, accurate projector/backprojector pair for use with iterative image reconstruction for two-dimensional fan-beam transmission imaging, unpublished
    • (2002)
    • Politte, D.G.1    Whiting, B.2
  • 19
    • 29144515780 scopus 로고    scopus 로고
    • Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: A simulation study
    • Shikhaliev P M 2005 Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study Phys. Med. Biol. 50 5813-27
    • (2005) Phys. Med. Biol. , vol.50 , Issue.24 , pp. 5813-5827
    • Shikhaliev, P.M.1
  • 20
    • 0034310513 scopus 로고    scopus 로고
    • Penalized weighted least-squares image reconstruction in single and dual energy x-ray computed tomography
    • Sukovic P and Clinthorne N H 2000 Penalized weighted least-squares image reconstruction in single and dual energy x-ray computed tomography IEEE Trans. Med. Imaging 19 1075-81
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.11 , pp. 1075-1081
    • Sukovic, P.1    Clinthorne, N.H.2
  • 21
    • 0015667930 scopus 로고
    • Absorption and noise in x-ray phosphors
    • Swank R K 1973 Absorption and noise in x-ray phosphors J. Appl. Phys. 44 4199
    • (1973) J. Appl. Phys. , vol.44 , Issue.9 , pp. 4199
    • Swank, R.K.1
  • 23
    • 0036798793 scopus 로고    scopus 로고
    • Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction
    • Williamson J F, Whiting B R, Benac J, Murphy R J, Blaine G J, O'sullivan J A, Politte D G and Snyder D L 2002 Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction Med. Phys. 29 2404-18
    • (2002) Med. Phys. , vol.29 , Issue.10 , pp. 2404-2418
    • Williamson, J.F.1    Whiting, B.R.2    Benac, J.3    Murphy, R.J.4    Blaine, G.J.5    O'Sullivan, J.A.6    Politte, D.G.7    Snyder, D.L.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.