Fracture strength and fatigue resistance of all-ceramic molar crowns manufactured with CAD/CAM technology

Author keywords

Cyclic loading; Fatigue resistance; Feldspathic porcelain; Fracture strength; Zirconium oxide ceramics

Indexed keywords

ALUMINUM SILICATE; PANAVIA FLUORO; PANAVIA-FLUORO; POTASSIUM DERIVATIVE; RESIN CEMENT; YTTRIA STABILIZED TETRAGONAL ZIRCONIA POLYCRYSTALS CERAMIC; YTTRIA-STABILIZED TETRAGONAL ZIRCONIA POLYCRYSTALS CERAMIC; YTTRIUM;

EID: 47249085178     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2008.00305.x     Document Type: Article
Times cited : (101)

References (54)
  • 2
    • 0034241846 scopus 로고    scopus 로고
    • Cytotoxicity of dental alloys, metals, and ceramics assessed by millipore filter, agar overlay, and MTT tests
    • Sjogren G, Sletten G, Dahl JE : Cytotoxicity of dental alloys, metals, and ceramics assessed by millipore filter, agar overlay, and MTT tests. J Prosthet Dent 2000 84 : 229 236
    • (2000) J Prosthet Dent , vol.84 , pp. 229-236
    • Sjogren, G.1    Sletten, G.2    Dahl, J.E.3
  • 3
    • 0028537137 scopus 로고
    • Where is the gap? Machinable ceramic systems and conventional laboratory restorations at a glance
    • Siervo S, Pampalone A, Siervo P, et al : Where is the gap? Machinable ceramic systems and conventional laboratory restorations at a glance. Quintessence Int 1994 25 : 773 779
    • (1994) Quintessence Int , vol.25 , pp. 773-779
    • Siervo, S.1    Pampalone, A.2    Siervo, P.3    Al, E.4
  • 4
    • 0036593234 scopus 로고    scopus 로고
    • Long-term clinical success of all-ceramic posterior restorations
    • Blatz MB : Long-term clinical success of all-ceramic posterior restorations. Quintessence Int 2002 33 : 415 426
    • (2002) Quintessence Int , vol.33 , pp. 415-426
    • Blatz, M.B.1
  • 5
    • 9944256780 scopus 로고    scopus 로고
    • Ceramic Behavior under Different Environmental and Loading Conditions
    • Chicago, IL, Quintessence, pp.
    • Drummond JL, Eliades G : Ceramic Behavior Under Different Environmental and Loading Conditions. Dental Materials In Vivo: Aging and Related Phenomena. Chicago, IL, Quintessence, 2003, pp. 35 45
    • (2003) Dental Materials in Vivo: Aging and Related Phenomena. , pp. 35-45
    • Drummond, J.L.1    Eliades, G.2
  • 7
    • 0016071137 scopus 로고
    • Slow crack growth in brittle materials under dynamic loading conditions
    • Evans AG : Slow crack growth in brittle materials under dynamic loading conditions. Int J Fract 1974 10 : 251 259
    • (1974) Int J Fract , vol.10 , pp. 251-259
    • Evans, A.G.1
  • 8
    • 0016471942 scopus 로고
    • Fracture stress and its dependence on slow crack growth
    • Evans AG, Johnson H : Fracture stress and its dependence on slow crack growth. J Mater Sci 1975 10 : 214 222
    • (1975) J Mater Sci , vol.10 , pp. 214-222
    • Evans, A.G.1    Johnson, H.2
  • 9
    • 0001572676 scopus 로고
    • Moisture assisted crack growth in ceramics
    • Wiederho SM : Moisture assisted crack growth in ceramics. Int J Fract Mech 1968 4 : 171 177
    • (1968) Int J Fract Mech , vol.4 , pp. 171-177
    • Wiederho, S.M.1
  • 11
    • 3242748246 scopus 로고    scopus 로고
    • Dental ceramics: Current thinking and trends
    • viii
    • Kelly JR : Dental ceramics: current thinking and trends. Dent Clin North Am 2004 48 : viii, 513 530
    • (2004) Dent Clin North Am , vol.48 , pp. 513-530
    • Kelly, J.R.1
  • 13
    • 0029262154 scopus 로고
    • Stress fatigue: Basic principles and prosthodontic implications
    • Wiskott HW, Nicholls JI, Belser UC : Stress fatigue: basic principles and prosthodontic implications. Int J Prosthodont 1995 8 : 105 116
    • (1995) Int J Prosthodont , vol.8 , pp. 105-116
    • Wiskott, H.W.1    Nicholls, J.I.2    Belser, U.C.3
  • 14
    • 9944254157 scopus 로고    scopus 로고
    • Influence of cyclic loading and luting agents on the fracture load of two all-ceramic crown systems
    • Attia A, Kern M : Influence of cyclic loading and luting agents on the fracture load of two all-ceramic crown systems. J Prosthet Dent 2004 92 : 551 556
    • (2004) J Prosthet Dent , vol.92 , pp. 551-556
    • Attia, A.1    Kern, M.2
  • 15
    • 0033209858 scopus 로고    scopus 로고
    • Effects of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns
    • Chen HY, Hickel R, Setcos JC, et al : Effects of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns. J Prosthet Dent 1999 82 : 468 475
    • (1999) J Prosthet Dent , vol.82 , pp. 468-475
    • Chen, H.Y.1    Hickel, R.2    Setcos, J.C.3    Al, E.4
  • 16
    • 0026102567 scopus 로고
    • Strength of the In-Ceram system under mechanical loads and thermocycling in artificial saliva
    • Kappert HF, Knode H, Schultheiss R : Strength of the In-Ceram system under mechanical loads and thermocycling in artificial saliva. Dtsch Zahnarztl Z 1991 46 : 129 131
    • (1991) Dtsch Zahnarztl Z , vol.46 , pp. 129-131
    • Kappert, H.F.1    Knode, H.2    Schultheiss, R.3
  • 17
    • 0027585968 scopus 로고
    • Fracture strength of all-porcelain, resin-bonded bridges after testing in an artificial oral environment
    • Kern M, Douglas WH, Fechtig T, et al : Fracture strength of all-porcelain, resin-bonded bridges after testing in an artificial oral environment. J Dent 1993 21 : 117 121
    • (1993) J Dent , vol.21 , pp. 117-121
    • Kern, M.1    Douglas, W.H.2    Fechtig, T.3    Al, E.4
  • 18
    • 0032610772 scopus 로고    scopus 로고
    • Effects of cyclic loading on the strength of all-ceramic materials
    • Ohyama T, Yoshinari M, Oda Y : Effects of cyclic loading on the strength of all-ceramic materials. Int J Prosthodont 1999 12 : 28 37
    • (1999) Int J Prosthodont , vol.12 , pp. 28-37
    • Ohyama, T.1    Yoshinari, M.2    Oda, Y.3
  • 19
    • 0032062509 scopus 로고    scopus 로고
    • Investigation of the dry and wet fatigue properties of three all-ceramic crown systems
    • Sobrinho LC, Cattell MJ, Glover RH, et al : Investigation of the dry and wet fatigue properties of three all-ceramic crown systems. Int J Prosthodont 1998 11 : 255 262
    • (1998) Int J Prosthodont , vol.11 , pp. 255-262
    • Sobrinho, L.C.1    Cattell, M.J.2    Glover, R.H.3    Al, E.4
  • 20
    • 0032170619 scopus 로고    scopus 로고
    • Comparison of the wet and dry fatigue properties of all ceramic crowns
    • Sobrinho LC, Glover RH, Knowles JC, et al : Comparison of the wet and dry fatigue properties of all ceramic crowns. J Mater Sci Mater Med 1998 9 : 517 521
    • (1998) J Mater Sci Mater Med , vol.9 , pp. 517-521
    • Sobrinho, L.C.1    Glover, R.H.2    Knowles, J.C.3    Al, E.4
  • 21
    • 0032195997 scopus 로고    scopus 로고
    • Fracture strength of 5 different all-ceramic crown systems
    • Strub JR, Beschnidt SM : Fracture strength of 5 different all-ceramic crown systems. Int J Prosthodont 1998 11 : 602 609
    • (1998) Int J Prosthodont , vol.11 , pp. 602-609
    • Strub, J.R.1    Beschnidt, S.M.2
  • 22
    • 11844264547 scopus 로고    scopus 로고
    • Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic
    • Guazzato M, Quach L, Albakry M, et al : Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic. J Dent 2005 33 : 9 18
    • (2005) J Dent , vol.33 , pp. 9-18
    • Guazzato, M.1    Quach, L.2    Albakry, M.3    Al, E.4
  • 23
    • 1842783267 scopus 로고    scopus 로고
    • Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics
    • Guazzato M, Albakry M, Ringer SP, et al : Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004 20 : 449 456
    • (2004) Dent Mater , vol.20 , pp. 449-456
    • Guazzato, M.1    Albakry, M.2    Ringer, S.P.3    Al, E.4
  • 24
    • 22644448001 scopus 로고    scopus 로고
    • Flexural strength of a layered zirconia and porcelain dental all-ceramic system
    • White SN, Miklus VG, McLaren EA, et al : Flexural strength of a layered zirconia and porcelain dental all-ceramic system. J Prosthet Dent 2005 94 : 125 131
    • (2005) J Prosthet Dent , vol.94 , pp. 125-131
    • White, S.N.1    Miklus, V.G.2    McLaren, E.A.3    Al, E.4
  • 25
    • 47249102416 scopus 로고
    • Vitablocks Mark II CEREC Porcelain
    • Liverpool, UK, Liverpool University Press, pp.
    • Jedynakiewicz NM : Vitablocks Mark II CEREC Porcelain. CAD-CAM in Restorative Dentistry: CEREC Method. Liverpool, UK, Liverpool University Press, 1993, pp. 147 148
    • (1993) CAD-CAM in Restorative Dentistry: CEREC Method. , pp. 147-148
    • Jedynakiewicz, N.M.1
  • 26
    • 0347482410 scopus 로고    scopus 로고
    • Fracture load of CAD/CAM-generated slot-inlay FPDs
    • Bindl A, Luthy H, Mormann WH : Fracture load of CAD/CAM-generated slot-inlay FPDs. Int J Prosthodont 2003 16 : 653 660
    • (2003) Int J Prosthodont , vol.16 , pp. 653-660
    • Bindl, A.1    Luthy, H.2    Mormann, W.H.3
  • 27
    • 0030330338 scopus 로고    scopus 로고
    • Mechanical properties of a new mica-based machinable glass ceramic for CAD/CAM restorations
    • Thompson JY, Bayne SC, Heymann HO : Mechanical properties of a new mica-based machinable glass ceramic for CAD/CAM restorations. J Prosthet Dent 1996 76 : 619 623
    • (1996) J Prosthet Dent , vol.76 , pp. 619-623
    • Thompson, J.Y.1    Bayne, S.C.2    Heymann, H.O.3
  • 28
    • 0031615244 scopus 로고    scopus 로고
    • Resistance to fracture of three all-ceramic systems
    • Neiva G, Yaman P, Dennison JB, et al : Resistance to fracture of three all-ceramic systems. J Esthet Dent 1998 10 : 60 66
    • (1998) J Esthet Dent , vol.10 , pp. 60-66
    • Neiva, G.1    Yaman, P.2    Dennison, J.B.3    Al, E.4
  • 29
    • 47249161897 scopus 로고    scopus 로고
    • Bond strength of porcelain to zirconia
    • Abstract 544)
    • Giordano R, Abrosa C, Ober R, et al : Bond strength of porcelain to zirconia. J Dent Res 2005 84 (Special Issue A Abstract 544)
    • (2005) J Dent Res , vol.84
    • Giordano, R.1    Abrosa, C.2    Ober, R.3    Al, E.4
  • 30
    • 0038644503 scopus 로고    scopus 로고
    • Resin-ceramic bonding: A review of the literature
    • Blatz MB, Sadan A, Kern M : Resin-ceramic bonding: a review of the literature. J Prosthet Dent 2003 89 : 268 274
    • (2003) J Prosthet Dent , vol.89 , pp. 268-274
    • Blatz, M.B.1    Sadan, A.2    Kern, M.3
  • 31
    • 1842527538 scopus 로고    scopus 로고
    • Fracture strength of all-ceramic crowns luted using two bonding methods
    • Attia A, Kern M : Fracture strength of all-ceramic crowns luted using two bonding methods. J Prosthet Dent 2004 91 : 247 252
    • (2004) J Prosthet Dent , vol.91 , pp. 247-252
    • Attia, A.1    Kern, M.2
  • 32
    • 2342589454 scopus 로고    scopus 로고
    • Cementation of zirconium-oxide ceramic restorations
    • Blatz MB : Cementation of zirconium-oxide ceramic restorations. Pract Proced Aesthet Dent 2004 16 : 14
    • (2004) Pract Proced Aesthet Dent , vol.16 , pp. 14
    • Blatz, M.B.1
  • 33
    • 2942547986 scopus 로고    scopus 로고
    • Fracture resistance of three all-ceramic restorative systems for posterior applications
    • Pallis K, Griggs JA, Woody RD, et al : Fracture resistance of three all-ceramic restorative systems for posterior applications. J Prosthet Dent 2004 91 : 561 569
    • (2004) J Prosthet Dent , vol.91 , pp. 561-569
    • Pallis, K.1    Griggs, J.A.2    Woody, R.D.3    Al, E.4
  • 34
    • 0033146116 scopus 로고    scopus 로고
    • Clinically relevant approach to failure testing of all-ceramic restorations
    • Kelly JR : Clinically relevant approach to failure testing of all-ceramic restorations. J Prosthet Dent 1999 81 : 652 661
    • (1999) J Prosthet Dent , vol.81 , pp. 652-661
    • Kelly, J.R.1
  • 35
    • 33646122906 scopus 로고    scopus 로고
    • Simulating clinical failure during in vitro testing of all-ceramic crowns
    • Abstract 1175)
    • Kelly JR, Hunter BD, Brenyo MR, et al : Simulating clinical failure during in vitro testing of all-ceramic crowns. J Dent Res 1998 77 (Special Issue B 778 (Abstract 1175)
    • (1998) J Dent Res , vol.77 , pp. 778
    • Kelly, J.R.1    Hunter, B.D.2    Brenyo, M.R.3    Al, E.4
  • 36
    • 0003749418 scopus 로고
    • (ed 2). Cambridge, UK, Cambridge University Press, pp.
    • Lawn B : Fracture of Brittle Solids (ed 2). Cambridge, UK, Cambridge University Press, 1993, pp. 249 306
    • (1993) Fracture of Brittle Solids , pp. 249-306
    • Lawn, B.1
  • 37
    • 32244437938 scopus 로고    scopus 로고
    • Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns
    • Attia A, Abdelaziz KM, Freitag S, et al : Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns. J Prosthet Dent 2006 95 : 117 123
    • (2006) J Prosthet Dent , vol.95 , pp. 117-123
    • Attia, A.1    Abdelaziz, K.M.2    Freitag, S.3    Al, E.4
  • 39
    • 0025492382 scopus 로고
    • Fracture surface analysis of dental ceramics: Clinically failed restorations
    • Kelly JR, Giordano R, Pober R, et al : Fracture surface analysis of dental ceramics: clinically failed restorations. Int J Prosthodont 1990 3 : 430 440
    • (1990) Int J Prosthodont , vol.3 , pp. 430-440
    • Kelly, J.R.1    Giordano, R.2    Pober, R.3    Al, E.4
  • 40
    • 0033301391 scopus 로고    scopus 로고
    • Zirconia-TZP and alumina-advanced technologies for the manufacturing of single crowns
    • Luthardt RG, Sandkuhl O, Reitz B : Zirconia-TZP and alumina-advanced technologies for the manufacturing of single crowns. Eur J Prosthodont Restor Dent 1999 7 : 113 119
    • (1999) Eur J Prosthodont Restor Dent , vol.7 , pp. 113-119
    • Luthardt, R.G.1    Sandkuhl, O.2    Reitz, B.3
  • 41
    • 29144487947 scopus 로고    scopus 로고
    • Load-to-fracture value of different all-ceramic crown systems
    • Snyder MD, Hogg KD : Load-to-fracture value of different all-ceramic crown systems. J Contemp Dent Pract 2005 6 : 54 63
    • (2005) J Contemp Dent Pract , vol.6 , pp. 54-63
    • Snyder, M.D.1    Hogg, K.D.2
  • 42
    • 3242741859 scopus 로고    scopus 로고
    • A comparison of fracture strength of yttrium-oxide- partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics
    • Sundh A, Sjogren G : A comparison of fracture strength of yttrium-oxide- partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. J Oral Rehabil 2004 31 : 682 688
    • (2004) J Oral Rehabil , vol.31 , pp. 682-688
    • Sundh, A.1    Sjogren, G.2
  • 43
    • 47249109268 scopus 로고    scopus 로고
    • Fracture strength of two oxide ceramic crown materials after cyclic preloading and thermocycling
    • Vult von SP : Fracture strength of two oxide ceramic crown materials after cyclic preloading and thermocycling. Swed Dent J Suppl 2005 173 : 1 21
    • (2005) Swed Dent J Suppl , Issue.173 , pp. 1-21
    • Vult Von, S.P.1
  • 44
    • 30144443459 scopus 로고    scopus 로고
    • Resistance to fracture of two all-ceramic crown materials following endodontic access
    • Wood KC, Berzins DW, Luo Q, et al : Resistance to fracture of two all-ceramic crown materials following endodontic access. J Prosthet Dent 2006 95 : 33 41
    • (2006) J Prosthet Dent , vol.95 , pp. 33-41
    • Wood, K.C.1    Berzins, D.W.2    Luo, Q.3    Al, E.4
  • 45
    • 1942468620 scopus 로고    scopus 로고
    • Strength, reliability and mode of fracture of bilayered porcelain/zirconia (Y-TZP) dental ceramics
    • Guazzato M, Proos K, Quach L, et al : Strength, reliability and mode of fracture of bilayered porcelain/zirconia (Y-TZP) dental ceramics. Biomaterials 2004 25 : 5045 5052
    • (2004) Biomaterials , vol.25 , pp. 5045-5052
    • Guazzato, M.1    Proos, K.2    Quach, L.3    Al, E.4
  • 46
    • 0028709614 scopus 로고
    • Fracture surface characterization of clinically failed all-ceramic crowns
    • Thompson JY, Anusavice KJ, Naman A, et al : Fracture surface characterization of clinically failed all-ceramic crowns. J Dent Res 1994 73 : 1824 1832
    • (1994) J Dent Res , vol.73 , pp. 1824-1832
    • Thompson, J.Y.1    Anusavice, K.J.2    Naman, A.3    Al, E.4
  • 47
    • 33746623731 scopus 로고    scopus 로고
    • Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics
    • Aboushelib MN, Kleverlaan CJ, Feilzer AJ : Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: zirconia veneering ceramics. Dent Mater 2006 22 : 857 863
    • (2006) Dent Mater , vol.22 , pp. 857-863
    • Aboushelib, M.N.1    Kleverlaan, C.J.2    Feilzer, A.J.3
  • 48
    • 0242289420 scopus 로고    scopus 로고
    • The influence of the veneering porcelain and different surface treatments on the biaxial flexural strength of a heat-pressed ceramic
    • Isgro G, Pallav P, Van Der Zel JM, et al : The influence of the veneering porcelain and different surface treatments on the biaxial flexural strength of a heat-pressed ceramic. J Prosthet Dent 2003 90 : 465 473
    • (2003) J Prosthet Dent , vol.90 , pp. 465-473
    • Isgro, G.1    Pallav, P.2    Van Der Zel, J.M.3    Al, E.4
  • 49
    • 25144511110 scopus 로고    scopus 로고
    • Microtensile bond strength of different components of core veneered all-ceramic restorations
    • Aboushelib MN, de JN, Kleverlaan CJ, Feilzer AJ : Microtensile bond strength of different components of core veneered all-ceramic restorations. Dent Mater 2005 21 : 984 991
    • (2005) Dent Mater , vol.21 , pp. 984-991
    • Aboushelib, M.N.1    De, J.N.2    Kleverlaan, C.J.3    Feilzer, A.J.4
  • 50
    • 1942489372 scopus 로고    scopus 로고
    • Shear strength of core-veneer interface in bi-layered ceramics
    • Al-Dohan HM, Yaman P, Dennison JB, et al : Shear strength of core-veneer interface in bi-layered ceramics. J Prosthet Dent 2004 91 : 349 355
    • (2004) J Prosthet Dent , vol.91 , pp. 349-355
    • Al-Dohan, H.M.1    Yaman, P.2    Dennison, J.B.3    Al, E.4
  • 51
    • 0029318343 scopus 로고
    • Failure of all-ceramic fixed partial dentures in vitro and in vivo: Analysis and modeling
    • Kelly JR, Tesk JA, Sorensen JA : Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling. J Dent Res 1995 74 : 1253 1258
    • (1995) J Dent Res , vol.74 , pp. 1253-1258
    • Kelly, J.R.1    Tesk, J.A.2    Sorensen, J.A.3
  • 52
    • 0036886280 scopus 로고    scopus 로고
    • Transformation-toughened zirconia for dental inlays, crowns and bridges: Chemical stability and effect of low-temperature aging on flexural strength and surface structure
    • Ardlin BI : Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of low-temperature aging on flexural strength and surface structure. Dent Mater 2002 18 : 590 595
    • (2002) Dent Mater , vol.18 , pp. 590-595
    • Ardlin, B.I.1
  • 53
    • 2342500842 scopus 로고    scopus 로고
    • Critical effect of cubic phase on aging in 3mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis
    • Chevalier J, Deville S, Munch E, et al : Critical effect of cubic phase on aging in 3mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis. Biomaterials 2004 25 : 5539 5545
    • (2004) Biomaterials , vol.25 , pp. 5539-5545
    • Chevalier, J.1    Deville, S.2    Munch, E.3    Al, E.4
  • 54
    • 16344387546 scopus 로고    scopus 로고
    • Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing
    • Sundh A, Molin M, Sjogren G : Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater 2005 21 : 476 482
    • (2005) Dent Mater , vol.21 , pp. 476-482
    • Sundh, A.1    Molin, M.2    Sjogren, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.