1
-
-
1542358759
-
Microneedles for transdermal drug delivery
-
M. R. Prausnitz, "Microneedles for transdermal drug delivery," Adv. Drug Deliv. Rev., vol. 56, pp. 581-587, 2004.
-
(2004)
Adv. Drug Deliv. Rev
, vol.56
, pp. 581-587
-
-
Prausnitz, M.R.1
-
2
-
-
0034902043
-
Novel mechanisms and devices to enable successful transdermal drug delivery
-
B. Barry, "Novel mechanisms and devices to enable successful transdermal drug delivery," Eur. J. Pharmaceut. Sci., vol. 14, pp. 101-114, 2001.
-
(2001)
Eur. J. Pharmaceut. Sci
, vol.14
, pp. 101-114
-
-
Barry, B.1
-
3
-
-
1242308254
-
Current status and future potential of transdermal drug delivery
-
M. R. Prausnitz, S. Mitragotri, and R. Langer, "Current status and future potential of transdermal drug delivery," Nat. Rev. Drug. Discov., vol. 3, pp. 115-124, 2004.
-
(2004)
Nat. Rev. Drug. Discov
, vol.3
, pp. 115-124
-
-
Prausnitz, M.R.1
Mitragotri, S.2
Langer, R.3
-
4
-
-
0035142406
-
Lack of pain associated with microfabricated microneedles
-
S. Kaushik, A. H. Hord, D. D. Denson, D. V. McAllister, S. Smitra, M. G. Allen, and M. R. Prausnitz, "Lack of pain associated with microfabricated microneedles," Anesth. Analg., vol. 92, pp. 502-504, 2001.
-
(2001)
Anesth. Analg
, vol.92
, pp. 502-504
-
-
Kaushik, S.1
Hord, A.H.2
Denson, D.D.3
McAllister, D.V.4
Smitra, S.5
Allen, M.G.6
Prausnitz, M.R.7
-
5
-
-
17444403584
-
Clinical microneedle injection of methyl nicotinate: Stratum corneum penetration
-
R. K. Sivamani, B. Stoeber, G. C. Wu, H. Zhai, D. Liepmann, and H. Maibach, "Clinical microneedle injection of methyl nicotinate: Stratum corneum penetration," Skin Res. Technol., vol. 11, no. 11, pp. 152-156, 2005.
-
(2005)
Skin Res. Technol
, vol.11
, Issue.11
, pp. 152-156
-
-
Sivamani, R.K.1
Stoeber, B.2
Wu, G.C.3
Zhai, H.4
Liepmann, D.5
Maibach, H.6
-
6
-
-
39749113820
-
-
U.S. Patent No.3,964,482: Drug Delivery Device 1976
-
M. Gerstel and V. Place, U.S. Patent No.3,964,482: Drug Delivery Device 1976.
-
-
-
Gerstel, M.1
Place, V.2
-
7
-
-
0035659567
-
Transdermal delivery of antisense oligonucleotides with microprojection patch (Macroflux) technology
-
W. Lin, M. Cormier, A. Samiee, A. Griffin, B. Johnson, C. Teng, G. Hardee, and P. Daddona, "Transdermal delivery of antisense oligonucleotides with microprojection patch (Macroflux) technology," Pharmaceut. Res., vol. 18, no. 12, pp. 1789-1793, 2001.
-
(2001)
Pharmaceut. Res
, vol.18
, Issue.12
, pp. 1789-1793
-
-
Lin, W.1
Cormier, M.2
Samiee, A.3
Griffin, A.4
Johnson, B.5
Teng, C.6
Hardee, G.7
Daddona, P.8
-
8
-
-
0036007129
-
Macroflux microprojection array patch technology: A new and efficient approach for intracutaneous immunization
-
J. A. Matriano, M. Cormier, J. Johnson, W. Young, M. Buttery, K. Nyam, and P. Daddona, "Macroflux microprojection array patch technology: A new and efficient approach for intracutaneous immunization," Pharmaceut. Res., vol. 19, no. 1, pp. 63-70, 2002.
-
(2002)
Pharmaceut. Res
, vol.19
, Issue.1
, pp. 63-70
-
-
Matriano, J.A.1
Cormier, M.2
Johnson, J.3
Young, W.4
Buttery, M.5
Nyam, K.6
Daddona, P.7
-
9
-
-
0036105150
-
Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery
-
Online, Available
-
J. A. Mikszta, J. B. Alarcon, J. M. Brittingham, D. E. Sutter, R. J. Pettis, and N. G. Harvey, "Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery," Nat. Med., vol. 8, no. 4, pp. 415-9, 2002 [Online]. Available: http://www.dx.doi.org/10.1038/nm0402-415
-
(2002)
Nat. Med
, vol.8
, Issue.4
, pp. 415-419
-
-
Mikszta, J.A.1
Alarcon, J.B.2
Brittingham, J.M.3
Sutter, D.E.4
Pettis, R.J.5
Harvey, N.G.6
-
10
-
-
0344270926
-
-
D. V. McAllister, P. M. Wang, S. P. Davis, J.-H. Park, P. J. Canatella, M. G. Allen, and M. R. Prausnitz, Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies, Proc. Nat. Acad. Sci. USA, 100, no. 24, pp. 13 755-13 760, 2003 [Online]. Available: http://www.pnas.org/cgi/content/abstract/100/24/ 13755
-
D. V. McAllister, P. M. Wang, S. P. Davis, J.-H. Park, P. J. Canatella, M. G. Allen, and M. R. Prausnitz, "Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies," Proc. Nat. Acad. Sci. USA, vol. 100, no. 24, pp. 13 755-13 760, 2003 [Online]. Available: http://www.pnas.org/cgi/content/abstract/100/24/ 13755
-
-
-
-
11
-
-
0742301752
-
Silicon micromachined hollow microneedles for transdermal liquid transport
-
Jun
-
H. J. G. E. Gardeniers, R. Luttge, E. J. W. Berenschot, M. J. de Boer, S. Y. Yeshurun, M. Hefetz, R. van't Oever, and A. van den Berg, "Silicon micromachined hollow microneedles for transdermal liquid transport," IEEE ASME J. Microelectromech. Syst., vol. 12, no. 6, pp. 855-862, Jun. 2003.
-
(2003)
IEEE ASME J. Microelectromech. Syst
, vol.12
, Issue.6
, pp. 855-862
-
-
Gardeniers, H.J.G.E.1
Luttge, R.2
Berenschot, E.J.W.3
de Boer, M.J.4
Yeshurun, S.Y.5
Hefetz, M.6
van't Oever, R.7
van den Berg, A.8
-
12
-
-
3042809905
-
Transdermal delivery of insulin using microneedles in vivo
-
W. Martanto, S. Davis, H. Holiday, J. Wang, H. Gill, and M. Prausnitz, "Transdermal delivery of insulin using microneedles in vivo," Pharmaceut. Res., vol. 21, no. 6, pp. 947-952, 2004.
-
(2004)
Pharmaceut. Res
, vol.21
, Issue.6
, pp. 947-952
-
-
Martanto, W.1
Davis, S.2
Holiday, H.3
Wang, J.4
Gill, H.5
Prausnitz, M.6
-
13
-
-
18744377499
-
Hollow metal microneedles for insulin delivery to diabetic rats
-
May
-
S. Davis, W. Martanto, M. Allen, and M. Prausnitz, "Hollow metal microneedles for insulin delivery to diabetic rats," IEEE Trans. Biomed. Eng., vol. 52, no. 5, pp. 909-915, May 2005.
-
(2005)
IEEE Trans. Biomed. Eng
, vol.52
, Issue.5
, pp. 909-915
-
-
Davis, S.1
Martanto, W.2
Allen, M.3
Prausnitz, M.4
-
14
-
-
0036092989
-
Characterization of micromachined spiked biopotential electrodes
-
Jun
-
P. Griss, H. Tolvanen-Laakso, P. Merilainen, and G. Stemme, "Characterization of micromachined spiked biopotential electrodes," IEEE Trans. Biomed. Eng., vol. 49, no. 6, pp. 597-604, Jun. 2002.
-
(2002)
IEEE Trans. Biomed. Eng
, vol.49
, Issue.6
, pp. 597-604
-
-
Griss, P.1
Tolvanen-Laakso, H.2
Merilainen, P.3
Stemme, G.4
-
15
-
-
27744539771
-
Non-invasive and microinvasive electrical impedance spectra of skin cancer - A comparison between two techniques
-
Online, Available
-
P. Åberg, P. Geladi, I. Nicander, J. Hansson, U. Holmgren, and S. Ollmar, "Non-invasive and microinvasive electrical impedance spectra of skin cancer - A comparison between two techniques," Skin Res. Technol., vol. 11, no. 4, pp. 281-286, 2005 [Online]. Available: http://www.blackwell-synergy.com/doi/abs/10.1111/j.0909-725X.2005.00125.x
-
(2005)
Skin Res. Technol
, vol.11
, Issue.4
, pp. 281-286
-
-
Åberg, P.1
Geladi, P.2
Nicander, I.3
Hansson, J.4
Holmgren, U.5
Ollmar, S.6
-
16
-
-
0037871729
-
Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
-
Dec
-
P. Griss and G. Stemme, "Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer," IEEE ASME J. Microelectromech. Syst., vol. 12, no. 3, pp. 296-301, Dec. 2003.
-
(2003)
IEEE ASME J. Microelectromech. Syst
, vol.12
, Issue.3
, pp. 296-301
-
-
Griss, P.1
Stemme, G.2
-
17
-
-
0037235939
-
Can needle-free administration of vaccines become the norm in global immunization?
-
Online, Available
-
M. M. Levine, "Can needle-free administration of vaccines become the norm in global immunization?," Nat. Med., vol. 9, no. 1, pp. 99-103, 2003 [Online]. Available: http://www.dx.doi.org/10.1038/nm0103-99
-
(2003)
Nat. Med
, vol.9
, Issue.1
, pp. 99-103
-
-
Levine, M.M.1
-
18
-
-
17644390191
-
Vaccines: Past, present and future
-
S. A. Plotkin, "Vaccines: Past, present and future," Nat. Med., vol. 11, no. 4, pp. S5-S11, 2005.
-
(2005)
Nat. Med
, vol.11
, Issue.4
-
-
Plotkin, S.A.1
-
19
-
-
33646148967
-
Precise microinjection into skin using hollow microneedles
-
Online, Available
-
P. M. Wang, M. Cornwell, J. Hill, and M. R. Prausnitz, "Precise microinjection into skin using hollow microneedles," J. Investig. Dermatol., vol. 126, no. 5, pp. 1080-1087, 2006 [Online]. Available: http://www.dx.doi.org/10.1038/sj.jid.5700150
-
(2006)
J. Investig. Dermatol
, vol.126
, Issue.5
, pp. 1080-1087
-
-
Wang, P.M.1
Cornwell, M.2
Hill, J.3
Prausnitz, M.R.4
-
20
-
-
32244440926
-
Microinfusion using hollow microneedles
-
W. Martanto, J. S. Moore, O. Kashlan, R. Kamath, P. M. Wang, J. M. O'Neal, and M. R. Prausnitz, "Microinfusion using hollow microneedles," Pharmaceut. Res., vol. 23, no. 1, pp. 104-113, 2006.
-
(2006)
Pharmaceut. Res
, vol.23
, Issue.1
, pp. 104-113
-
-
Martanto, W.1
Moore, J.S.2
Kashlan, O.3
Kamath, R.4
Wang, P.M.5
O'Neal, J.M.6
Prausnitz, M.R.7
-
21
-
-
33646709695
-
Mechanism of fluid infusion during microneedle insertion and retraction
-
Online, Available
-
W. Martanto, J. S. Moore, T. Couse, and M. R. Prausnitz, "Mechanism of fluid infusion during microneedle insertion and retraction," J. Control Release, vol. 112, no. 3, pp. 357-361, 2006 [Online]. Available: http://www.sciencedirect.com/science/article/B6T3D-4JS206B-1/2/ adf0925867608d5b4734cf1bfca4c487
-
(2006)
J. Control Release
, vol.112
, Issue.3
, pp. 357-361
-
-
Martanto, W.1
Moore, J.S.2
Couse, T.3
Prausnitz, M.R.4
-
22
-
-
0027370108
-
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus, New Eng. J. Med., 329, no. 14, pp. 977-986, 1993 [Online]. Available: http://www.content.nejm.org/cgi/content/abstract/329/14/ 977, The Diabetes Control and Complications Trial Research Group
-
"The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus," New Eng. J. Med., vol. 329, no. 14, pp. 977-986, 1993 [Online]. Available: http://www.content.nejm.org/cgi/content/abstract/329/14/ 977, The Diabetes Control and Complications Trial Research Group
-
-
-
-
23
-
-
39749194934
-
-
Sep. 2006, Online, Available
-
"Minimed paradigm insulin pumps," Sep. 2006. [Online]. Available: http://www.minimed.com
-
Minimed paradigm insulin pumps
-
-
-
25
-
-
3042553015
-
A review of micropumps
-
Online, Available
-
D. J. Laser and J. G. Santiago, "A review of micropumps," J. Micromech. Microeng., vol. 14, no. 6, pp. R35-R64, 2004 [Online]. Available: http://www.stacks.iop.org/0960-1317/14/R35
-
(2004)
J. Micromech. Microeng
, vol.14
, Issue.6
-
-
Laser, D.J.1
Santiago, J.G.2
-
26
-
-
0037716781
-
Electrothermally actuated inline microfluidic valve
-
Online, Available: http://www.dx.doi.org/10.1016/S0924-4247(03)00030-X
-
P. Selvaganapathy, E. T. Carlen, and C. H. Mastrangelo, "Electrothermally actuated inline microfluidic valve," Sens. Actuators A, Phys., vol. 104, no. 3, pp. 275-282, 2003 [Online]. Available: http://www.dx.doi.org/10.1016/S0924-4247(03)00030-X
-
(2003)
Sens. Actuators A, Phys
, vol.104
, Issue.3
, pp. 275-282
-
-
Selvaganapathy, P.1
Carlen, E.T.2
Mastrangelo, C.H.3
-
27
-
-
12444299614
-
Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers
-
C. Yu, S. Mutlu, P. Selvaganapathy, C. Mastrangelo, F. Svec, and J. Frechet, "Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers," Anal. Chem., vol. 75, pp. 1958-1961, 2003.
-
(2003)
Anal. Chem
, vol.75
, pp. 1958-1961
-
-
Yu, C.1
Mutlu, S.2
Selvaganapathy, P.3
Mastrangelo, C.4
Svec, F.5
Frechet, J.6
-
28
-
-
33947208945
-
A thermally responsive PDMS composite and its microfluidic applications
-
B. Samel, P. Griss, and G. Stemme, "A thermally responsive PDMS composite and its microfluidic applications," IEEE ASME J. Microelectromech. Syst., vol. 16, no. 1, pp. 50-57, 2007.
-
(2007)
IEEE ASME J. Microelectromech. Syst
, vol.16
, Issue.1
, pp. 50-57
-
-
Samel, B.1
Griss, P.2
Stemme, G.3
-
29
-
-
36949000879
-
Penetration-enhanced ultra-sharp microneedles and prediction on skin interaction for efficient transdermal drug delivery
-
Dec
-
N. Roxhed, T. C. Gasser, P. Griss, G. A. Holzapfel, and G. Stemme, "Penetration-enhanced ultra-sharp microneedles and prediction on skin interaction for efficient transdermal drug delivery," IEEE ASME J. Microelectromech. Syst., vol. 16, no. 6, pp. 1429-1440, Dec. 2007.
-
(2007)
IEEE ASME J. Microelectromech. Syst
, vol.16
, Issue.6
, pp. 1429-1440
-
-
Roxhed, N.1
Gasser, T.C.2
Griss, P.3
Holzapfel, G.A.4
Stemme, G.5
-
30
-
-
27544444627
-
Film transfer and bonding technique to cover lab on a chip
-
J. W. Kwon, S. Kamal-Bahl, and E. S. Kim, "Film transfer and bonding technique to cover lab on a chip," in Proc. IEEE Int. Conf. Solid-State Sensors, Actuators, and Microsystems (Transducers), 2005, vol. 1, pp. 940-943.
-
(2005)
Proc. IEEE Int. Conf. Solid-State Sensors, Actuators, and Microsystems (Transducers)
, vol.1
, pp. 940-943
-
-
Kwon, J.W.1
Kamal-Bahl, S.2
Kim, E.S.3
-
32
-
-
0036240178
-
Evaluation of MEMS materials of construction for implantable medical devices
-
Online, Available
-
G. Kotzar, M. Freas, P. Abel, A. Fleischman, S. Roy, C. Zorman, J. M. Moran, and J. Melzak, "Evaluation of MEMS materials of construction for implantable medical devices," Biomaterials, vol. 23, no. 13, pp. 2737-2750, 2002 [Online]. Available: http://www.sciencedirect.com/science/ article/B6TWB-44XTMP8-1/2/819e74899475ca357cc88748c98f6424
-
(2002)
Biomaterials
, vol.23
, Issue.13
, pp. 2737-2750
-
-
Kotzar, G.1
Freas, M.2
Abel, P.3
Fleischman, A.4
Roy, S.5
Zorman, C.6
Moran, J.M.7
Melzak, J.8
-
33
-
-
0037400556
-
Biocompatibility and biofouling of MEMS drug delivery devices
-
Online, Available
-
G. Voskerician, M. S. Shive, R. S. Shawgo, H. von Recum, J. M. Anderson, M. J. Cima, and R. Langer, "Biocompatibility and biofouling of MEMS drug delivery devices," Biomaterials, vol. 24, no. 11, pp. 1959-1967, 2003 [Online]. Available: http://www.sciencedirect.com/science/article/B6TWB- 47VS5BP-7/2/03785737a42db8291177b62e195975e3
-
(2003)
Biomaterials
, vol.24
, Issue.11
, pp. 1959-1967
-
-
Voskerician, G.1
Shive, M.S.2
Shawgo, R.S.3
von Recum, H.4
Anderson, J.M.5
Cima, M.J.6
Langer, R.7
-
34
-
-
0346777282
-
An in vivo biocompatibility assessment of MEMS materials for spinal fusion monitoring
-
Online, Available
-
L. Ferrara, A. Fleischman, D. Togawa, T. Bauer, E. Benzel, and S. Roy, "An in vivo biocompatibility assessment of MEMS materials for spinal fusion monitoring," Biomed. Microdevices, vol. 5, no. 4, pp. 297-302, 2003 [Online]. Available: http://www.dx.doi.org/10.1023/A:1027305729456
-
(2003)
Biomed. Microdevices
, vol.5
, Issue.4
, pp. 297-302
-
-
Ferrara, L.1
Fleischman, A.2
Togawa, D.3
Bauer, T.4
Benzel, E.5
Roy, S.6
-
35
-
-
0015254063
-
Epidermal "turnover time" - A re-examination
-
Online, Available
-
K. M. Halparin, "Epidermal "turnover time" - A re-examination," Brit. J. Dermat., vol. 86, no. 1, pp. 14-19, 1972 [Online]. Available: http://www.blackwell-synergy.com/doi/abs/10.1111/j.1365- 2133.1972.tb01886.x
-
(1972)
Brit. J. Dermat
, vol.86
, Issue.1
, pp. 14-19
-
-
Halparin, K.M.1
|