메뉴 건너뛰기




Volumn 206, Issue 3, 1998, Pages 599-607

Wavelet compression of medical images

Author keywords

Images, storage and retrieval; Picture archiving and communication system (PACS); State of art reviews

Indexed keywords

COMPUTER PROGRAM; DIAGNOSTIC IMAGING; DIGITAL RADIOGRAPHY; IMAGE PROCESSING; IMAGE RECONSTRUCTION; INFORMATION RETRIEVAL; PRIORITY JOURNAL; REVIEW;

EID: 0031882994     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.206.3.9494473     Document Type: Review
Times cited : (99)

References (45)
  • 2
    • 0026142897 scopus 로고
    • The JPEG still picture compression standard
    • Wallace GK. The JPEG still picture compression standard. Comm ACM 1991; 34:30-44.
    • (1991) Comm ACM , vol.34 , pp. 30-44
    • Wallace, G.K.1
  • 3
    • 0028372949 scopus 로고
    • Displaying radiologic images on personal computers: Image storage and compression. II
    • Erratum: J Digit Imaging 1994; 7:60
    • Gillespy T III, Rowberg AH. Displaying radiologic images on personal computers: image storage and compression. II. J Digit Imaging 1994; 7:1-12. [Erratum: J Digit Imaging 1994; 7:60.]
    • (1994) J Digit Imaging , vol.7 , pp. 1-12
    • Gillespy III, T.1    Rowberg, A.H.2
  • 4
    • 0027740437 scopus 로고
    • Interactive wavelet-based 2-D and 3-D image compression
    • Manduca A. Interactive wavelet-based 2-D and 3-D image compression. Proc SPIE 1993; 1897:307-318.
    • (1993) Proc SPIE , vol.1897 , pp. 307-318
    • Manduca, A.1
  • 5
    • 0024921922 scopus 로고
    • Wavelets and dilation equations: A brief introduction
    • Strang G. Wavelets and dilation equations: a brief introduction. SIAM Rev 1989; 31:614-627.
    • (1989) SIAM Rev , vol.31 , pp. 614-627
    • Strang, G.1
  • 7
    • 0024700097 scopus 로고
    • A theory for multiresolution signal decomposition
    • Mallat S. A theory for multiresolution signal decomposition. IEEE Trans Pattern Anal Machine Intell 1989; 11:674-693.
    • (1989) IEEE Trans Pattern Anal Machine Intell , vol.11 , pp. 674-693
    • Mallat, S.1
  • 8
    • 0030127507 scopus 로고    scopus 로고
    • A review of waveless in biomedical applications
    • Unser M, Aldroubi A. A review of waveless in biomedical applications. Proc IEEE 1996; 84:626-638.
    • (1996) Proc IEEE , vol.84 , pp. 626-638
    • Unser, M.1    Aldroubi, A.2
  • 10
  • 11
    • 0027798110 scopus 로고
    • Embedded image coding using zerotrees of wavelet coeffficients
    • Shapiro JM. Embedded image coding using zerotrees of wavelet coeffficients. IEEE Trans Signal Processing 1993; 41:3445-3462.
    • (1993) IEEE Trans Signal Processing , vol.41 , pp. 3445-3462
    • Shapiro, J.M.1
  • 13
    • 0030173121 scopus 로고    scopus 로고
    • A new fast and effficient image codec based on set partitioning in hierarchical trees
    • Said A, Pearlman W. A new fast and effficient image codec based on set partitioning in hierarchical trees. IEEE Trans Circuits Systems Video Technology 1996; 6:243-250.
    • (1996) IEEE Trans Circuits Systems Video Technology , vol.6 , pp. 243-250
    • Said, A.1    Pearlman, W.2
  • 15
    • 0000563196 scopus 로고
    • Ideal denoising in an orthonormal basis chosen from a library of bases
    • Donoho DI, Johnstone IM. Ideal denoising in an orthonormal basis chosen from a library of bases. Comptes Rendus Acad Sci 1994; 319:1311-1322.
    • (1994) Comptes Rendus Acad Sci , vol.319 , pp. 1311-1322
    • Donoho, D.I.1    Johnstone, I.M.2
  • 16
    • 0031195551 scopus 로고    scopus 로고
    • Evaluation of irreversible compression of digitized PA chest radiographs
    • Erickson BJ, Manduca A, Persons KR, et al. Evaluation of irreversible compression of digitized PA chest radiographs. J Digit Imaging 1997; 10:97-102.
    • (1997) J Digit Imaging , vol.10 , pp. 97-102
    • Erickson, B.J.1    Manduca, A.2    Persons, K.R.3
  • 18
    • 0001935107 scopus 로고
    • What's wrong with mean-squared error?
    • Watson A, ed. Cambridge, Mass: MIT Press
    • Girod B. What's wrong with mean-squared error? In: Watson A, ed. Digital images and human vision. Cambridge, Mass: MIT Press, 1993; 207-220.
    • (1993) Digital Images and Human Vision , pp. 207-220
    • Girod, B.1
  • 19
    • 0025901562 scopus 로고
    • Evaluation of the effect of noise on subjective image quality
    • Barten P. Evaluation of the effect of noise on subjective image quality. Proc SPIE 1991; 1453:2-15.
    • (1991) Proc SPIE , vol.1453 , pp. 2-15
    • Barten, P.1
  • 20
    • 0000075547 scopus 로고
    • Objective image quality measure derived from digital image power spectra
    • Will N, Bouzas B. Objective image quality measure derived from digital image power spectra. Opt Eng 1992; 31:813-825.
    • (1992) Opt Eng , vol.31 , pp. 813-825
    • Will, N.1    Bouzas, B.2
  • 21
    • 0029706394 scopus 로고    scopus 로고
    • Evaluation of image compression using plausible "non visually weighted" image fidelity measures
    • Good W, Lattner S, Maitz G. Evaluation of image compression using plausible "non visually weighted" image fidelity measures. Proc SPIE 1996; 2707:301-309.
    • (1996) Proc SPIE , vol.2707 , pp. 301-309
    • Good, W.1    Lattner, S.2    Maitz, G.3
  • 22
    • 0029697570 scopus 로고    scopus 로고
    • Visually weighted assessment of image degradation resulting from image compression
    • Lattner S, Good W, Maitz G. Visually weighted assessment of image degradation resulting from image compression. Proc SPIE 1996; 2707:507-518.
    • (1996) Proc SPIE , vol.2707 , pp. 507-518
    • Lattner, S.1    Good, W.2    Maitz, G.3
  • 23
    • 0025299945 scopus 로고
    • Clinical evaluation of irreversible image compression: Analysis of chest imaging with computed radiography
    • Ishigaki T, Sakuma S, Ikeda M, Itch Y, Suzuki M, Iwai S. Clinical evaluation of irreversible image compression: analysis of chest imaging with computed radiography. Radiology 1990; 175:739-743.
    • (1990) Radiology , vol.175 , pp. 739-743
    • Ishigaki, T.1    Sakuma, S.2    Ikeda, M.3    Itch, Y.4    Suzuki, M.5    Iwai, S.6
  • 24
    • 0031021235 scopus 로고    scopus 로고
    • Focal hepatic lesions: Effect of three-dimensional wavelet compression on detection at CT
    • Goldberg MA, Gazelle GS, Boland GW, et al. Focal hepatic lesions: effect of three-dimensional wavelet compression on detection at CT. Radiology 1997; 202:159-165.
    • (1997) Radiology , vol.202 , pp. 159-165
    • Goldberg, M.A.1    Gazelle, G.S.2    Boland, G.W.3
  • 25
    • 0029160703 scopus 로고
    • Detection of discrete white matter lesions after irreversible compression of MR images
    • Clunie DA, Mitchell PI, Howieson J, Roman-Goldstein S, Szumowski J. Detection of discrete white matter lesions after irreversible compression of MR images. AJNR 1995; 16:1435-1440.
    • (1995) AJNR , vol.16 , pp. 1435-1440
    • Clunie, D.A.1    Mitchell, P.I.2    Howieson, J.3    Roman-Goldstein, S.4    Szumowski, J.5
  • 26
    • 0028486916 scopus 로고
    • Joint photographic experts group (JPEG) compatible data compression of mammograms
    • Good WE, Maitz GS, Gur D. Joint photographic experts group (JPEG) compatible data compression of mammograms. J Digit Imaging 1994; 7:123-132.
    • (1994) J Digit Imaging , vol.7 , pp. 123-132
    • Good, W.E.1    Maitz, G.S.2    Gur, D.3
  • 27
    • 0028445482 scopus 로고
    • Evaluating quality of compressed medical images: SNR, subjective rating, and diagnostic accuracy
    • Cosman PC, Gray RM, Olshen RA. Evaluating quality of compressed medical images: SNR, subjective rating, and diagnostic accuracy. Proc IEEE 1994; 82:919-932.
    • (1994) Proc IEEE , vol.82 , pp. 919-932
    • Cosman, P.C.1    Gray, R.M.2    Olshen, R.A.3
  • 28
    • 0030035975 scopus 로고    scopus 로고
    • Clinical use of lossy image compression in digital angiography
    • Elion JE, Whiting JS. Clinical use of lossy image compression in digital angiography (editorial). Am J Cardiol 1996; 78:219-220.
    • (1996) Am J Cardiol , vol.78 , pp. 219-220
    • Elion, J.E.1    Whiting, J.S.2
  • 29
    • 0028021577 scopus 로고
    • Application of wavelet compression to digitized radiographs
    • Goldberg MA, Pivovarov M, Mayo-Smith WW, et al. Application of wavelet compression to digitized radiographs. AJR 1994; 163:463-468.
    • (1994) AJR , vol.163 , pp. 463-468
    • Goldberg, M.A.1    Pivovarov, M.2    Mayo-Smith, W.W.3
  • 31
    • 0027398152 scopus 로고
    • A new asymmetric screen-film combination for conventional chest radiography: Evaluation in 50 patients
    • Swensen SJ, Gray JE, Brown LR, Aughenbaugh GL, Harms GF, Stears J. A new asymmetric screen-film combination for conventional chest radiography: evaluation in 50 patients. AJR 1993; 160:483-486.
    • (1993) AJR , vol.160 , pp. 483-486
    • Swensen, S.J.1    Gray, J.E.2    Brown, L.R.3    Aughenbaugh, G.L.4    Harms, G.F.5    Stears, J.6
  • 32
    • 0030201349 scopus 로고    scopus 로고
    • Clinical evaluation of irreversible data compression for computed radiography in excretory urography
    • Uchida K, Nakamura K, Watanabe H, et al. Clinical evaluation of irreversible data compression for computed radiography in excretory urography. J Digit Imaging 1996; 9:145-149.
    • (1996) J Digit Imaging , vol.9 , pp. 145-149
    • Uchida, K.1    Nakamura, K.2    Watanabe, H.3
  • 33
    • 0030095040 scopus 로고    scopus 로고
    • Impact of lossy image compression on accuracy of caries detection in digital images taken with a storage phosphor system
    • Wenzel A, Gottredsen E, Borg E, Grondahl HG. Impact of lossy image compression on accuracy of caries detection in digital images taken with a storage phosphor system. Oral Surg Med Pathol Radiol Endodont 1996; 81:351-355.
    • (1996) Oral Surg Med Pathol Radiol Endodont , vol.81 , pp. 351-355
    • Wenzel, A.1    Gottredsen, E.2    Borg, E.3    Grondahl, H.G.4
  • 34
    • 0026993091 scopus 로고
    • Effect of data compression on diagnostic accuracy in digital hand and chest radiography
    • Sayre J, Aberle DR, Boechat I, et al. Effect of data compression on diagnostic accuracy in digital hand and chest radiography. Proc SPIE 1992; 1653:232-240.
    • (1992) Proc SPIE , vol.1653 , pp. 232-240
    • Sayre, J.1    Aberle, D.R.2    Boechat, I.3
  • 35
    • 0031883646 scopus 로고    scopus 로고
    • Detection of subtle abnormalities on chest radiographs after irreversible compression
    • Savcenko V, Erickson BJ, Palisson PM, et al. Detection of subtle abnormalities on chest radiographs after irreversible compression. Radiology 1998; 206:609-616.
    • (1998) Radiology , vol.206 , pp. 609-616
    • Savcenko, V.1    Erickson, B.J.2    Palisson, P.M.3
  • 36
    • 0027982780 scopus 로고
    • Irreversible data compression in chest imaging using computed radiography: An evaluation
    • Mori T, Nakata H. Irreversible data compression in chest imaging using computed radiography: an evaluation. J Thorac Imaging 1994; 9:23-30.
    • (1994) J Thorac Imaging , vol.9 , pp. 23-30
    • Mori, T.1    Nakata, H.2
  • 37
    • 0026007731 scopus 로고
    • Data compression: Effect on diagnostic accuracy in digital chest radiography
    • MacMahon H, Doi K, Sanada S, et al. Data compression: effect on diagnostic accuracy in digital chest radiography. Radiology 1991; 178:175-179.
    • (1991) Radiology , vol.178 , pp. 175-179
    • MacMahon, H.1    Doi, K.2    Sanada, S.3
  • 39
    • 0029127982 scopus 로고
    • Objective methods for optimizing JPEG compression of coronary angiographic images
    • Onnasch DG, Prause GP, Ploger A. Objective methods for optimizing JPEG compression of coronary angiographic images. Int J Card Imaging 1995; 11:151-162.
    • (1995) Int J Card Imaging , vol.11 , pp. 151-162
    • Onnasch, D.G.1    Prause, G.P.2    Ploger, A.3
  • 40
    • 0028854570 scopus 로고
    • Using JPEG image compression to facilitate telemedicine
    • Yamamoto LG. Using JPEG image compression to facilitate telemedicine. Am J Emerg Med 1995; 13:55-57.
    • (1995) Am J Emerg Med , vol.13 , pp. 55-57
    • Yamamoto, L.G.1
  • 41
    • 0027849701 scopus 로고
    • The effect of irreversible image compression on diagnostic accuracy in thoracic imaging
    • Aberle DR, Gleeson F, Sayre JW, et al. The effect of irreversible image compression on diagnostic accuracy in thoracic imaging. Invest Radiol 1993; 28:398-403.
    • (1993) Invest Radiol , vol.28 , pp. 398-403
    • Aberle, D.R.1    Gleeson, F.2    Sayre, J.W.3
  • 42
    • 0029810535 scopus 로고    scopus 로고
    • Image compression in digital mammography: Effects on computerized detection of subtle microcalcifications
    • Chan HP, Lo SC, Niklason LT, Ikeda DM, Lam KL. Image compression in digital mammography: effects on computerized detection of subtle microcalcifications. Med Phys 1996; 23:1325-1336.
    • (1996) Med Phys , vol.23 , pp. 1325-1336
    • Chan, H.P.1    Lo, S.C.2    Niklason, L.T.3    Ikeda, D.M.4    Lam, K.L.5
  • 43
    • 0029124155 scopus 로고
    • Applying wavelet transforms with arithmetic coding to radiological image compression
    • Saiptech P, Ho BK, Panwar R, Ma M, Wei J. Applying wavelet transforms with arithmetic coding to radiological image compression. IEEE Eng Med Biol 1995; 14:587-593.
    • (1995) IEEE Eng Med Biol , vol.14 , pp. 587-593
    • Saiptech, P.1    Ho, B.K.2    Panwar, R.3    Ma, M.4    Wei, J.5
  • 45
    • 2642708030 scopus 로고    scopus 로고
    • Radiology devices: Proposed classifications for five medical image management devices
    • December 2
    • Food and Drug Administration. Radiology devices: proposed classifications for five medical image management devices. Federal Register, December 2, 1996; 61:63769-63774.
    • (1996) Federal Register , vol.61 , pp. 63769-63774


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.