메뉴 건너뛰기




Volumn 42, Issue 2, 2001, Pages 156-160

Effects of JPEG and wavelet compression of spiral low-dose ct images on detection of small lung cancers

Author keywords

CT; Data compression; JPEG algorithm; Lung cancer; Wavelet algorithm

Indexed keywords

ALGORITHM; ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; LUNG TUMOR; METHODOLOGY; PATHOLOGY; RADIOGRAPHY; ROC CURVE;

EID: 0035263541     PISSN: 02841851     EISSN: None     Source Type: Journal    
DOI: 10.1080/028418501127346657     Document Type: Article
Times cited : (30)

References (11)
  • 1
    • 0028008897 scopus 로고
    • Thoracic CT images. Effect of lossy image compression on diagnostic accuracy
    • COSMAN P. C., DAVIDSON H. C., BERGIN C. J. et al.: Thoracic CT images. Effect of lossy image compression on diagnostic accuracy. Radiology 190 (1994), 517.
    • (1994) Radiology , vol.190 , pp. 517
    • Cosman, P.C.1    Davidson, H.C.2    Bergin, C.J.3
  • 2
    • 0031882994 scopus 로고    scopus 로고
    • Wavelet compression of medical images
    • ERICKSON B. J., MANDUCA A., PERSONS K. R. et al.: Wavelet compression of medical images. Radiology 206 (1998), 599.
    • (1998) Radiology , vol.206 , pp. 599
    • Erickson, B.J.1    Manduca, A.2    Persons, K.R.3
  • 3
    • 0031021235 scopus 로고    scopus 로고
    • Focal hepatic lesions. Effect of three-dimensional wavelet compression on detection at CT
    • GOLDBERG M. A., GAZELLE G. S., BOLAND G. W. et al.: Focal hepatic lesions. Effect of three-dimensional wavelet compression on detection at CT Radiology 202 (1997), 159.
    • (1997) Radiology , vol.202 , pp. 159
    • Goldberg, M.A.1    Gazelle, G.S.2    Boland, G.W.3
  • 4
    • 0029805812 scopus 로고    scopus 로고
    • Peripheral lung cancer. Screening and detection with low-dose spiral CT versus radiography
    • KANEKO M., EGUCHI K., OHAMATSU H. et al.: Peripheral lung cancer. Screening and detection with low-dose spiral CT versus radiography. Radiology 201 (1996), 798.
    • (1996) Radiology , vol.201 , pp. 798
    • Kaneko, M.1    Eguchi, K.2    Ohamatsu, H.3
  • 5
    • 0026007731 scopus 로고
    • Data compression. Effect on diagnostic accuracy in digital chest radiography
    • MACMAHON H., DOI K., SANADA S. et al.: Data compression. Effect on diagnostic accuracy in digital chest radiography. Radiology 178 (1991), 175.
    • (1991) Radiology , vol.178 , pp. 175
    • Macmahon, H.1    Doi, K.2    Sanada, S.3
  • 6
    • 0030804883 scopus 로고    scopus 로고
    • Wavelet transform-based image compression for transmission of MR data
    • MALDIJIAN J. A., LIU W. C., HIRSCHORN D., MURTHY R. & SEMANCZUK W: Wavelet transform-based image compression for transmission of MR data. AJR 169 (1997), 23.
    • (1997) AJR , vol.169 , pp. 23
    • Maldijian, J.A.1    Liu, W.C.2    Hirschorn, D.3    Murthy, R.4    Semanczuk, W.5
  • 7
    • 0029738551 scopus 로고    scopus 로고
    • Wavelet compression of medical imagery
    • REITER E.: Wavelet compression of medical imagery. Telemed. J. 2 (1996), 131.
    • (1996) Telemed. J. , vol.2 , pp. 131
    • Reiter, E.1
  • 8
    • 0032471099 scopus 로고    scopus 로고
    • Wavelet versus JPEG (Joint Photographic Expert Group) and fractal compression
    • RICKE J., MAASS P., HANNINEN E. L. et al.: Wavelet versus JPEG (Joint Photographic Expert Group) and fractal compression. Invest. Radiol. 33 (1998), 456.
    • (1998) Invest. Radiol. , vol.33 , pp. 456
    • Ricke, J.1    Maass, P.2    Hanninen, E.L.3
  • 9
    • 0032015058 scopus 로고    scopus 로고
    • Introduction to wavelet-based compression of medical images
    • SCBOMER D. F., ELEKES A. A., HAZLE J. D. et al.: Introduction to wavelet-based compression of medical images. Radiographics 18 (1998), 469.
    • (1998) Radiographics , vol.18 , pp. 469
    • Scbomer, D.F.1    Elekes, A.A.2    Hazle, J.D.3
  • 10
    • 0034028146 scopus 로고    scopus 로고
    • Characteristics of small lung cancers invisible on conventional chest radiography and detected by population-based screening using spiral CT
    • SONE S., LI F., YANG Z. G. et al.: Characteristics of small lung cancers invisible on conventional chest radiography and detected by population-based screening using spiral CT. Br. J. Radiol. 73 (2000), 137.
    • (2000) Br. J. Radiol. , vol.73 , pp. 137
    • Sone, S.1    Li, F.2    Yang, Z.G.3
  • 11
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • SONE S., TAKASHIMA S., LI F. et al.: Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 351 (1998), 1242.
    • (1998) Lancet , vol.351 , pp. 1242
    • Sone, S.1    Takashima, S.2    Li, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.