-
2
-
-
9044240472
-
Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: a multicenter study
-
Budoff M.J., Georgiou D., Brody A., et al. Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: a multicenter study. Circulation 93 5 (1996) 898-904
-
(1996)
Circulation
, vol.93
, Issue.5
, pp. 898-904
-
-
Budoff, M.J.1
Georgiou, D.2
Brody, A.3
-
3
-
-
0025303528
-
Thrombotic and cardiovascular complications related to nonionic contrast media during cardiac catheterization: analysis of 8,517 patients
-
Davidson C.J., Mark D.B., Pieper K.S., et al. Thrombotic and cardiovascular complications related to nonionic contrast media during cardiac catheterization: analysis of 8,517 patients. Am J Cardiol 65 22 (1990) 1481-1484
-
(1990)
Am J Cardiol
, vol.65
, Issue.22
, pp. 1481-1484
-
-
Davidson, C.J.1
Mark, D.B.2
Pieper, K.S.3
-
4
-
-
0037433650
-
Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study
-
Omran H., Schmidt H., Hackenbroch M., et al. Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study. Lancet 361 9365 (2003) 1241-1246
-
(2003)
Lancet
, vol.361
, Issue.9365
, pp. 1241-1246
-
-
Omran, H.1
Schmidt, H.2
Hackenbroch, M.3
-
5
-
-
0020327391
-
The effect of rapid rise time magnetic fields on the ECG of the rat
-
Polson M.J., Barker A.T., and Gardiner S. The effect of rapid rise time magnetic fields on the ECG of the rat. Clin Phys Physiol Meas 3 3 (1982) 231-234
-
(1982)
Clin Phys Physiol Meas
, vol.3
, Issue.3
, pp. 231-234
-
-
Polson, M.J.1
Barker, A.T.2
Gardiner, S.3
-
6
-
-
0032873080
-
Novel real-time R wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions
-
Fischer S.E., Wickline S.A., and Lorenz C.H. Novel real-time R wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 42 2 (1999) 361-370
-
(1999)
Magn Reson Med
, vol.42
, Issue.2
, pp. 361-370
-
-
Fischer, S.E.1
Wickline, S.A.2
Lorenz, C.H.3
-
7
-
-
0034883846
-
Rapid evaluation of left ventricular volume and mass without breath holding using real-time interactive cardiac magnetic resonance imaging system
-
Kaji S., Yang P.C., Kerr A.B., et al. Rapid evaluation of left ventricular volume and mass without breath holding using real-time interactive cardiac magnetic resonance imaging system. J Am Coll Cardiol 38 2 (2001) 527-533
-
(2001)
J Am Coll Cardiol
, vol.38
, Issue.2
, pp. 527-533
-
-
Kaji, S.1
Yang, P.C.2
Kerr, A.B.3
-
8
-
-
0000456427
-
Coronary angiography. A technical, anatomic, and clinical study
-
Paulin S. Coronary angiography. A technical, anatomic, and clinical study. Acta Radiol Diagn (Stockh) Suppl 54 (1964) 1-215
-
(1964)
Acta Radiol Diagn (Stockh) Suppl
, vol.54
, pp. 1-215
-
-
Paulin, S.1
-
9
-
-
0032719272
-
Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography
-
Wang Y., Vidan E., and Bergman G.W. Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213 3 (1999) 751-758
-
(1999)
Radiology
, vol.213
, Issue.3
, pp. 751-758
-
-
Wang, Y.1
Vidan, E.2
Bergman, G.W.3
-
10
-
-
0031860874
-
Quantification of in-plane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification
-
Hofman M.B., Wickline S.A., and Lorenz C.H. Quantification of in-plane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification. J Magn Reson Imaging 8 3 (1998) 568-576
-
(1998)
J Magn Reson Imaging
, vol.8
, Issue.3
, pp. 568-576
-
-
Hofman, M.B.1
Wickline, S.A.2
Lorenz, C.H.3
-
11
-
-
0034801295
-
Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging
-
Kim W.Y., Danias P.G., Stuber M., et al. Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging. J Magn Reson Imaging 14 4 (2001) 383-390
-
(2001)
J Magn Reson Imaging
, vol.14
, Issue.4
, pp. 383-390
-
-
Kim, W.Y.1
Danias, P.G.2
Stuber, M.3
-
12
-
-
33645114985
-
Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta blocker use
-
Jahnke C., Paetsch I., Achenbach S., et al. Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta blocker use. Radiology 239 1 (2006) 71-78
-
(2006)
Radiology
, vol.239
, Issue.1
, pp. 71-78
-
-
Jahnke, C.1
Paetsch, I.2
Achenbach, S.3
-
13
-
-
34247632103
-
Comparison of individually adapted breath-hold and free-breathing coronary MRA using steady-state free precession
-
[abstract]
-
Jahnke C., Gebker R., Schnackenburg B., et al. Comparison of individually adapted breath-hold and free-breathing coronary MRA using steady-state free precession. [abstract]. J Cardiovasc Magn Reson 6 (2004) 166-167
-
(2004)
J Cardiovasc Magn Reson
, vol.6
, pp. 166-167
-
-
Jahnke, C.1
Gebker, R.2
Schnackenburg, B.3
-
14
-
-
0037306949
-
Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating
-
Plein S., Jones T.R., Ridgway J.P., et al. Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating. AJR Am J Roentgenol 180 2 (2003) 505-512
-
(2003)
AJR Am J Roentgenol
, vol.180
, Issue.2
, pp. 505-512
-
-
Plein, S.1
Jones, T.R.2
Ridgway, J.P.3
-
15
-
-
0033594967
-
Improved coronary artery definition with T2 weighted, free-breathing, three-dimensional coronary MRA
-
Botnar R.M., Stuber M., Danias P.G., et al. Improved coronary artery definition with T2 weighted, free-breathing, three-dimensional coronary MRA. Circulation 99 24 (1999) 3139-3148
-
(1999)
Circulation
, vol.99
, Issue.24
, pp. 3139-3148
-
-
Botnar, R.M.1
Stuber, M.2
Danias, P.G.3
-
16
-
-
26244453541
-
Correction for heart rate variability improves coronary magnetic resonance angiography
-
Leiner T., Katsimaglis G., Yeh E.N., et al. Correction for heart rate variability improves coronary magnetic resonance angiography. J Magn Reson Magn Imaging 22 (2005) 577-582
-
(2005)
J Magn Reson Magn Imaging
, vol.22
, pp. 577-582
-
-
Leiner, T.1
Katsimaglis, G.2
Yeh, E.N.3
-
17
-
-
34247619308
-
Automatic data acquisition window determination for coronary MRA
-
[abstract]
-
Bi X., Chung Y.C., Weale P., et al. Automatic data acquisition window determination for coronary MRA. [abstract]. J Cardiovasc Magn Reson 9 2 (2007) 234-235
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, Issue.2
, pp. 234-235
-
-
Bi, X.1
Chung, Y.C.2
Weale, P.3
-
18
-
-
4344713273
-
Nitrate-induced coronary vasodilation by stress-magnetic resonance imaging: a novel noninvasive test of coronary vasomotion
-
Pepe A., Lombardi M., Takacs I., et al. Nitrate-induced coronary vasodilation by stress-magnetic resonance imaging: a novel noninvasive test of coronary vasomotion. J Magn Reson Imaging 20 3 (2004) 390-394
-
(2004)
J Magn Reson Imaging
, vol.20
, Issue.3
, pp. 390-394
-
-
Pepe, A.1
Lombardi, M.2
Takacs, I.3
-
19
-
-
11144239428
-
Noninvasive assessment of coronary vasodilation using magnetic resonance angiography
-
Terachima M., Meyer C.H., Keeffe B.G., et al. Noninvasive assessment of coronary vasodilation using magnetic resonance angiography. J Am Coll Cardiol 45 1 (2005) 104-110
-
(2005)
J Am Coll Cardiol
, vol.45
, Issue.1
, pp. 104-110
-
-
Terachima, M.1
Meyer, C.H.2
Keeffe, B.G.3
-
20
-
-
0028929929
-
Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging
-
Wang Y., Riederer S.J., and Ehman R.L. Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn Reson Med 33 5 (1995) 713-719
-
(1995)
Magn Reson Med
, vol.33
, Issue.5
, pp. 713-719
-
-
Wang, Y.1
Riederer, S.J.2
Ehman, R.L.3
-
21
-
-
0031412991
-
MR navigator echo monitoring of temporal changes in diaphragm position: implications for MR coronary angiography
-
Taylor A.M., Jhooti P., Wiesmann F., et al. MR navigator echo monitoring of temporal changes in diaphragm position: implications for MR coronary angiography. J Magn Reson Imaging 7 4 (1997) 629-636
-
(1997)
J Magn Reson Imaging
, vol.7
, Issue.4
, pp. 629-636
-
-
Taylor, A.M.1
Jhooti, P.2
Wiesmann, F.3
-
22
-
-
33644788181
-
Analysis of residual coronary artery motion for breath-hold and navigator approaches using real-time coronary MRI
-
Fischer R.W., Botnar R.M., Nehrke K., et al. Analysis of residual coronary artery motion for breath-hold and navigator approaches using real-time coronary MRI. Magn Reson Med 55 3 (2006) 612-618
-
(2006)
Magn Reson Med
, vol.55
, Issue.3
, pp. 612-618
-
-
Fischer, R.W.1
Botnar, R.M.2
Nehrke, K.3
-
23
-
-
34247636140
-
Whole-heart cine MRI using real-time respiratory self-gating
-
[abstract]
-
Uribe S.A., Muthurangu V., Boubertakh Sr. R., et al. Whole-heart cine MRI using real-time respiratory self-gating. [abstract]. J Cardiovasc Magn Reson 9 2 (2007) 207-208
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, Issue.2
, pp. 207-208
-
-
Uribe, S.A.1
Muthurangu, V.2
Boubertakh Sr., R.3
-
24
-
-
0026316572
-
Coronary arteries: breath-hold MR angiography
-
Edelman R.R., Manning W.J., Burstein D., et al. Coronary arteries: breath-hold MR angiography. Radiology 181 3 (1991) 641-643
-
(1991)
Radiology
, vol.181
, Issue.3
, pp. 641-643
-
-
Edelman, R.R.1
Manning, W.J.2
Burstein, D.3
-
25
-
-
33745911137
-
The impact of different positions and thoraicial restrains on respiratory-induced cardiac motion
-
Huber S., Bornstedt A., Schnackenburg B., et al. The impact of different positions and thoraicial restrains on respiratory-induced cardiac motion. J Cardiovasc Magn Reson 8 3 (2006) 483-488
-
(2006)
J Cardiovasc Magn Reson
, vol.8
, Issue.3
, pp. 483-488
-
-
Huber, S.1
Bornstedt, A.2
Schnackenburg, B.3
-
26
-
-
0031788545
-
Diaphragmatic and cardiac motion during suspended breathing: preliminary experience and implications for breath-hold MR imaging
-
Holland A.E., Goldfarb J.W., and Edelman R.R. Diaphragmatic and cardiac motion during suspended breathing: preliminary experience and implications for breath-hold MR imaging. Radiology 209 2 (1998) 483-489
-
(1998)
Radiology
, vol.209
, Issue.2
, pp. 483-489
-
-
Holland, A.E.1
Goldfarb, J.W.2
Edelman, R.R.3
-
27
-
-
0031850651
-
Navigator assessment of breath-hold duration: impact of supplemental oxygen and hyperventilation
-
Danias P.G., Stuber M., Botnar R.M., et al. Navigator assessment of breath-hold duration: impact of supplemental oxygen and hyperventilation. AJR Am J Roentgenol 171 2 (1998) 395-397
-
(1998)
AJR Am J Roentgenol
, vol.171
, Issue.2
, pp. 395-397
-
-
Danias, P.G.1
Stuber, M.2
Botnar, R.M.3
-
28
-
-
0027280275
-
Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast
-
Li D., Paschal C.B., Haacke E.M., et al. Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. Radiology 187 2 (1993) 401-406
-
(1993)
Radiology
, vol.187
, Issue.2
, pp. 401-406
-
-
Li, D.1
Paschal, C.B.2
Haacke, E.M.3
-
29
-
-
0030966347
-
Comparison of respiratory suppression methods and navigator locations for MR coronary angiography
-
McConnell M.V., Khasgiwala V.C., Savord B.J., et al. Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol 168 5 (1997) 1369-1375
-
(1997)
AJR Am J Roentgenol
, vol.168
, Issue.5
, pp. 1369-1375
-
-
McConnell, M.V.1
Khasgiwala, V.C.2
Savord, B.J.3
-
30
-
-
0029848753
-
Two-dimensional coronary MR angiography without breath holding
-
Oshinski J.N., Hofland L., Mukundan Jr. S., et al. Two-dimensional coronary MR angiography without breath holding. Radiology 201 3 (1996) 737-743
-
(1996)
Radiology
, vol.201
, Issue.3
, pp. 737-743
-
-
Oshinski, J.N.1
Hofland, L.2
Mukundan Jr., S.3
-
31
-
-
0024453449
-
Adaptive technique for high-definition MR imaging of moving structures
-
Ehman R.L., and Felmlee J.P. Adaptive technique for high-definition MR imaging of moving structures. Radiology 173 1 (1989) 255-263
-
(1989)
Radiology
, vol.173
, Issue.1
, pp. 255-263
-
-
Ehman, R.L.1
Felmlee, J.P.2
-
32
-
-
0032810872
-
Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations
-
Stuber M., Botnar R.M., Danias P.G., et al. Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212 2 (1999) 579-587
-
(1999)
Radiology
, vol.212
, Issue.2
, pp. 579-587
-
-
Stuber, M.1
Botnar, R.M.2
Danias, P.G.3
-
33
-
-
0029952524
-
Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography
-
Post J.C., van Rossum A.C., Hofman M.B., et al. Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography. AJR Am J Roentgenol 166 6 (1996) 1399-1404
-
(1996)
AJR Am J Roentgenol
, vol.166
, Issue.6
, pp. 1399-1404
-
-
Post, J.C.1
van Rossum, A.C.2
Hofman, M.B.3
-
34
-
-
0029851614
-
Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating
-
Li D., Kaushikkar S., Haacke E.M., et al. Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. Radiology 201 3 (1996) 857-863
-
(1996)
Radiology
, vol.201
, Issue.3
, pp. 857-863
-
-
Li, D.1
Kaushikkar, S.2
Haacke, E.M.3
-
35
-
-
0036708122
-
Preliminary report on in vivo coronary MRA at 3 Tesla in humans
-
Stuber M., Botnar R.M., Fischer S.E., et al. Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 48 3 (2002) 425-429
-
(2002)
Magn Reson Med
, vol.48
, Issue.3
, pp. 425-429
-
-
Stuber, M.1
Botnar, R.M.2
Fischer, S.E.3
-
36
-
-
0032817865
-
Optimization of real-time adaptive navigator correction for 3D magnetic resonance coronary angiography
-
Nagel E., Bornstedt A., Schnackenburg B., et al. Optimization of real-time adaptive navigator correction for 3D magnetic resonance coronary angiography. Magn Reson Med 42 2 (1999) 408-411
-
(1999)
Magn Reson Med
, vol.42
, Issue.2
, pp. 408-411
-
-
Nagel, E.1
Bornstedt, A.2
Schnackenburg, B.3
-
37
-
-
0030977431
-
Prospective navigator correction of image position for coronary MR angiography
-
Danias P.G., McConnell M.V., Khasgiwala V.C., et al. Prospective navigator correction of image position for coronary MR angiography. Radiology 203 3 (1997) 733-736
-
(1997)
Radiology
, vol.203
, Issue.3
, pp. 733-736
-
-
Danias, P.G.1
McConnell, M.V.2
Khasgiwala, V.C.3
-
38
-
-
0032745137
-
Relationship between coronary artery and diaphragmatic respiratory motion: lessons from real-time cardiac MR imaging
-
Danias P.G., Stuber M., Botnar R.M., et al. Relationship between coronary artery and diaphragmatic respiratory motion: lessons from real-time cardiac MR imaging. AJR Am J Roentgenol 172 4 (1999) 1061-1065
-
(1999)
AJR Am J Roentgenol
, vol.172
, Issue.4
, pp. 1061-1065
-
-
Danias, P.G.1
Stuber, M.2
Botnar, R.M.3
-
39
-
-
0031033998
-
Prospective adaptive navigator correction for breath-hold MR coronary angiography
-
McConnell M.V., Khasgiwala V.C., Savord B.J., et al. Prospective adaptive navigator correction for breath-hold MR coronary angiography. Magn Reson Med 37 1 (1997) 148-152
-
(1997)
Magn Reson Med
, vol.37
, Issue.1
, pp. 148-152
-
-
McConnell, M.V.1
Khasgiwala, V.C.2
Savord, B.J.3
-
40
-
-
0036273882
-
Respiratory motion in coronary magnetic resonance angiography: a comparison of different motion models
-
Manke D., Nehrke K., Bornert P., et al. Respiratory motion in coronary magnetic resonance angiography: a comparison of different motion models. J Magn Reson Imaging 15 6 (2002) 661-671
-
(2002)
J Magn Reson Imaging
, vol.15
, Issue.6
, pp. 661-671
-
-
Manke, D.1
Nehrke, K.2
Bornert, P.3
-
41
-
-
0037587240
-
Novel prospective respiratory motion correction approach for free- breathing coronary MR angiography using a patient-adapted affine motion model
-
Manke D., Nehrke K., and Boernert P. Novel prospective respiratory motion correction approach for free- breathing coronary MR angiography using a patient-adapted affine motion model. Magn Reson Med 50 (2003) 122-131
-
(2003)
Magn Reson Med
, vol.50
, pp. 122-131
-
-
Manke, D.1
Nehrke, K.2
Boernert, P.3
-
42
-
-
0042592985
-
Direct monitoring of coronary artery motion with cardiac fat navigator echoes
-
Nguyen T.D., Nuval A., Mulukutla S., et al. Direct monitoring of coronary artery motion with cardiac fat navigator echoes. Magn Reson Med 50 (2003) 235-241
-
(2003)
Magn Reson Med
, vol.50
, pp. 235-241
-
-
Nguyen, T.D.1
Nuval, A.2
Mulukutla, S.3
-
43
-
-
0035148580
-
Superiority of prone position in free-breathing 3D coronary MRA in patients with coronary disease
-
Stuber M., Danias P.G., Botnar R.M., et al. Superiority of prone position in free-breathing 3D coronary MRA in patients with coronary disease. J Magn Reson Imaging 13 2 (2001) 185-191
-
(2001)
J Magn Reson Imaging
, vol.13
, Issue.2
, pp. 185-191
-
-
Stuber, M.1
Danias, P.G.2
Botnar, R.M.3
-
44
-
-
33750948187
-
Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography
-
Sakuma H., Ichikawa Y., Chino S., et al. Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. J Am Coll Cardiol 48 10 (2006) 1946-1950
-
(2006)
J Am Coll Cardiol
, vol.48
, Issue.10
, pp. 1946-1950
-
-
Sakuma, H.1
Ichikawa, Y.2
Chino, S.3
-
45
-
-
0034877825
-
The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography
-
Spuentrup E., Stuber M., Botnar R.M., et al. The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography. J Magn Reson Imaging 14 3 (2001) 311-318
-
(2001)
J Magn Reson Imaging
, vol.14
, Issue.3
, pp. 311-318
-
-
Spuentrup, E.1
Stuber, M.2
Botnar, R.M.3
-
46
-
-
0037626043
-
The impact of spatial resolution and respiratory motion on MR imaging of atherosclerotic plaque
-
Schar M., Kim W., and Stuber M. The impact of spatial resolution and respiratory motion on MR imaging of atherosclerotic plaque. J Magn Reson Imaging 17 5 (2003) 538-544
-
(2003)
J Magn Reson Imaging
, vol.17
, Issue.5
, pp. 538-544
-
-
Schar, M.1
Kim, W.2
Stuber, M.3
-
47
-
-
26844447059
-
4D Radial coronary artery imaging within a single breath hold: cine angiography with phase-sensitive fat suppression (CAPS)
-
Park J., Larson A.C., Zhang Q., et al. 4D Radial coronary artery imaging within a single breath hold: cine angiography with phase-sensitive fat suppression (CAPS). Magn Reson Med 54 5 (2005) 833-840
-
(2005)
Magn Reson Med
, vol.54
, Issue.5
, pp. 833-840
-
-
Park, J.1
Larson, A.C.2
Zhang, Q.3
-
48
-
-
0028937380
-
Coronary angiography with magnetization-prepared T2 contrast
-
Brittain J.H., Hu B.S., Wright G.A., et al. Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33 5 (1995) 689-696
-
(1995)
Magn Reson Med
, vol.33
, Issue.5
, pp. 689-696
-
-
Brittain, J.H.1
Hu, B.S.2
Wright, G.A.3
-
49
-
-
0036235861
-
Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation
-
Shea S.M., Deshpande V.S., Chung Y.C., et al. Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation. J Magn Reson Imaging 15 5 (2002) 597-602
-
(2002)
J Magn Reson Imaging
, vol.15
, Issue.5
, pp. 597-602
-
-
Shea, S.M.1
Deshpande, V.S.2
Chung, Y.C.3
-
50
-
-
0026877440
-
Magnetization transfer contrast in magnetic resonance imaging
-
Balaban R.S., and Ceckler T.L. Magnetization transfer contrast in magnetic resonance imaging. Magn Reson Q 8 2 (1992) 116-137
-
(1992)
Magn Reson Q
, vol.8
, Issue.2
, pp. 116-137
-
-
Balaban, R.S.1
Ceckler, T.L.2
-
51
-
-
34247579118
-
MR coronary vein imaging in cardiac resynchronization therapy: initial experience
-
[abstract]
-
Nezsafat R., Yeon S., Wylie J.V., et al. MR coronary vein imaging in cardiac resynchronization therapy: initial experience. [abstract]. J Cardiovasc Magn Reson 9 2 (2007) 139-140
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, Issue.2
, pp. 139-140
-
-
Nezsafat, R.1
Yeon, S.2
Wylie, J.V.3
-
53
-
-
0023100837
-
MR imaging of the aortic root and proximal coronary arteries
-
Paulin S., von Schulthess G.K., Fossel E., et al. MR imaging of the aortic root and proximal coronary arteries. AJR Am J Roentgenol 148 4 (1987) 665-670
-
(1987)
AJR Am J Roentgenol
, vol.148
, Issue.4
, pp. 665-670
-
-
Paulin, S.1
von Schulthess, G.K.2
Fossel, E.3
-
54
-
-
0027403101
-
A preliminary report comparing magnetic resonance coronary angiography with conventional angiography
-
Manning W.J., Li W., and Edelman R.R. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 328 12 (1993) 828-832
-
(1993)
N Engl J Med
, vol.328
, Issue.12
, pp. 828-832
-
-
Manning, W.J.1
Li, W.2
Edelman, R.R.3
-
55
-
-
0027395731
-
Fat-suppressed breath-hold magnetic resonance coronary angiography
-
Manning W.J., Li W., Boyle N., et al. Fat-suppressed breath-hold magnetic resonance coronary angiography. Circulation 87 1 (1993) 94-104
-
(1993)
Circulation
, vol.87
, Issue.1
, pp. 94-104
-
-
Manning, W.J.1
Li, W.2
Boyle, N.3
-
56
-
-
3042755199
-
Intra- and interstudy reproducibility of coronary artery diameter measurements in magnetic resonance coronary angiography
-
Keegan J., Horkaew P., Buchanan T.J., et al. Intra- and interstudy reproducibility of coronary artery diameter measurements in magnetic resonance coronary angiography. J Magn Reson Imaging 20 1 (2004) 160-166
-
(2004)
J Magn Reson Imaging
, vol.20
, Issue.1
, pp. 160-166
-
-
Keegan, J.1
Horkaew, P.2
Buchanan, T.J.3
-
57
-
-
0027053145
-
Fast spiral coronary artery imaging
-
Meyer C.H., Hu B.S., Nishimura D.G., et al. Fast spiral coronary artery imaging. Magn Reson Med 28 2 (1992) 202-213
-
(1992)
Magn Reson Med
, vol.28
, Issue.2
, pp. 202-213
-
-
Meyer, C.H.1
Hu, B.S.2
Nishimura, D.G.3
-
58
-
-
0032701253
-
Double-oblique free-breathing high-resolution three-dimensional coronary magnetic resonance angiography
-
Stuber M., Botnar R.M., Danias P.G., et al. Double-oblique free-breathing high-resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol 34 2 (1999) 524-531
-
(1999)
J Am Coll Cardiol
, vol.34
, Issue.2
, pp. 524-531
-
-
Stuber, M.1
Botnar, R.M.2
Danias, P.G.3
-
59
-
-
0037154321
-
Detection of vein graft disease using high-resolution magnetic resonance angiography
-
Langerak S.E., Vliegen H.W., de Roos A., et al. Detection of vein graft disease using high-resolution magnetic resonance angiography. Circulation 105 3 (2002) 328-333
-
(2002)
Circulation
, vol.105
, Issue.3
, pp. 328-333
-
-
Langerak, S.E.1
Vliegen, H.W.2
de Roos, A.3
-
60
-
-
1642528008
-
Coronary MR angiography: comparison of quantitative and qualitative data from four techniques
-
Maintz D., Aepfelbacher F.C., Kissinger K.V., et al. Coronary MR angiography: comparison of quantitative and qualitative data from four techniques. AJR Am J Roentgenol 182 2 (2004) 515-521
-
(2004)
AJR Am J Roentgenol
, vol.182
, Issue.2
, pp. 515-521
-
-
Maintz, D.1
Aepfelbacher, F.C.2
Kissinger, K.V.3
-
61
-
-
0034839555
-
3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries
-
Deshpande V.S., Shea S.M., Laub G., et al. 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries. Magn Reson Med 46 3 (2001) 494-502
-
(2001)
Magn Reson Med
, vol.46
, Issue.3
, pp. 494-502
-
-
Deshpande, V.S.1
Shea, S.M.2
Laub, G.3
-
62
-
-
4644225120
-
Feasibility and performance of breath-hold 3D TRUE-FISP coronary MRAQ using self-calibrating parallel acquisition
-
Park J., McCarthy R., and Li D. Feasibility and performance of breath-hold 3D TRUE-FISP coronary MRAQ using self-calibrating parallel acquisition. Magn Reson Med 52 1 (2004) 7-13
-
(2004)
Magn Reson Med
, vol.52
, Issue.1
, pp. 7-13
-
-
Park, J.1
McCarthy, R.2
Li, D.3
-
63
-
-
16444367513
-
Short breath-hold volumetric coronary MR angiography employing steady-state free precession in conjunction with parallel imaging
-
Niendorf T., Saranathan M., Lingamneni A., et al. Short breath-hold volumetric coronary MR angiography employing steady-state free precession in conjunction with parallel imaging. Magn Reson Med 53 4 (2005) 885-894
-
(2005)
Magn Reson Med
, vol.53
, Issue.4
, pp. 885-894
-
-
Niendorf, T.1
Saranathan, M.2
Lingamneni, A.3
-
64
-
-
0344305581
-
Whole-heart steady-state free precession coronary artery magnetic resonance angiography
-
Weber O.M., Martin A.J., and Higgins C.B. Whole-heart steady-state free precession coronary artery magnetic resonance angiography. Magn Reson Med 50 6 (2003) 1223-1228
-
(2003)
Magn Reson Med
, vol.50
, Issue.6
, pp. 1223-1228
-
-
Weber, O.M.1
Martin, A.J.2
Higgins, C.B.3
-
65
-
-
14744299542
-
Free-breathing 3D balanced FFE coronary magnetic resonance angiography with prolonged cardiac acquisition windows and intra-RR motion correction
-
Stehning C., Boernert P., Nehrke K., et al. Free-breathing 3D balanced FFE coronary magnetic resonance angiography with prolonged cardiac acquisition windows and intra-RR motion correction. Magn Reson Med 53 3 (2005) 719-723
-
(2005)
Magn Reson Med
, vol.53
, Issue.3
, pp. 719-723
-
-
Stehning, C.1
Boernert, P.2
Nehrke, K.3
-
66
-
-
33845887707
-
Reproducibility of free-breathing cardiovascular magnetic resonance coronary angiography
-
Greil G.F., Desai M.Y., Fenchel M., et al. Reproducibility of free-breathing cardiovascular magnetic resonance coronary angiography. J Cardiovasc Magn Reson 9 1 (2007) 49-56
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, Issue.1
, pp. 49-56
-
-
Greil, G.F.1
Desai, M.Y.2
Fenchel, M.3
-
67
-
-
0036828308
-
Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography
-
Spuentrup E., Boernert P., Botnar R.M., et al. Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography. Invest Radiol 37 11 (2002) 637-642
-
(2002)
Invest Radiol
, vol.37
, Issue.11
, pp. 637-642
-
-
Spuentrup, E.1
Boernert, P.2
Botnar, R.M.3
-
68
-
-
25144439472
-
Assessment of coronary arteries with total study time of less than 30 minutes using whole-heart coronary MR angiography
-
Sakuma H., Ichikawa Y., Suzawa N., et al. Assessment of coronary arteries with total study time of less than 30 minutes using whole-heart coronary MR angiography. Radiology 237 1 (2005) 316-321
-
(2005)
Radiology
, vol.237
, Issue.1
, pp. 316-321
-
-
Sakuma, H.1
Ichikawa, Y.2
Suzawa, N.3
-
69
-
-
0034082822
-
Free-breathing 3D coronary MRA: the impact of isotropic image resolution
-
Botnar R.M., Stuber M., and Kissinger K.V. Free-breathing 3D coronary MRA: the impact of isotropic image resolution. J Magn Reson Imaging 11 4 (2000) 389-393
-
(2000)
J Magn Reson Imaging
, vol.11
, Issue.4
, pp. 389-393
-
-
Botnar, R.M.1
Stuber, M.2
Kissinger, K.V.3
-
70
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays
-
Sodickson D.K., and Manning W.J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 38 4 (1997) 591-603
-
(1997)
Magn Reson Med
, vol.38
, Issue.4
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
71
-
-
33744549479
-
Toward single breath hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system
-
Niendorf T., Hardy C.J., and Giaquinto R.O. Toward single breath hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system. Magn Reson Med 56 1 (2006) 167-176
-
(2006)
Magn Reson Med
, vol.56
, Issue.1
, pp. 167-176
-
-
Niendorf, T.1
Hardy, C.J.2
Giaquinto, R.O.3
-
73
-
-
34247577535
-
Whole-heart coronary MRA using high SENSE factors
-
[abstract]
-
Weber O., Martin A., and Higgins C.B. Whole-heart coronary MRA using high SENSE factors. [abstract]. J Cardiovasc Magn Reson 6 1 (2004) 317-325
-
(2004)
J Cardiovasc Magn Reson
, vol.6
, Issue.1
, pp. 317-325
-
-
Weber, O.1
Martin, A.2
Higgins, C.B.3
-
74
-
-
27644446048
-
High-resolution steady-state free precession coronary magnetic resonance angiography within a breath hold: parallel imaging with extended cardiac data acquisition
-
Park J., Larson A.C., Zhang Q., et al. High-resolution steady-state free precession coronary magnetic resonance angiography within a breath hold: parallel imaging with extended cardiac data acquisition. Magn Reson Med 54 5 (2005) 1100-1106
-
(2005)
Magn Reson Med
, vol.54
, Issue.5
, pp. 1100-1106
-
-
Park, J.1
Larson, A.C.2
Zhang, Q.3
-
75
-
-
0034799783
-
Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography
-
Bornert P., Stuber M., Botnar R.M., et al. Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography. Magn Reson Med 46 4 (2001) 789-794
-
(2001)
Magn Reson Med
, vol.46
, Issue.4
, pp. 789-794
-
-
Bornert, P.1
Stuber, M.2
Botnar, R.M.3
-
76
-
-
0032994288
-
Fast magnetic resonance coronary angiography with a three-dimensional stack of spirals trajectory
-
Thedens D.R., Irarrazaval P., Sachs T.S., et al. Fast magnetic resonance coronary angiography with a three-dimensional stack of spirals trajectory. Magn Reson Med 41 6 (1999) 1170-1179
-
(1999)
Magn Reson Med
, vol.41
, Issue.6
, pp. 1170-1179
-
-
Thedens, D.R.1
Irarrazaval, P.2
Sachs, T.S.3
-
77
-
-
0035163255
-
Improved 3D spiral imaging for coronary MR angiography
-
Bornert P., Aldefeld B., and Nehrke K. Improved 3D spiral imaging for coronary MR angiography. Magn Reson Med 45 1 (2001) 172-175
-
(2001)
Magn Reson Med
, vol.45
, Issue.1
, pp. 172-175
-
-
Bornert, P.1
Aldefeld, B.2
Nehrke, K.3
-
78
-
-
4344637817
-
Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences
-
Weber O.M., Pujadas S., Martin A.J., et al. Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences. J Magn Reson Imaging 20 3 (2004) 395-402
-
(2004)
J Magn Reson Imaging
, vol.20
, Issue.3
, pp. 395-402
-
-
Weber, O.M.1
Pujadas, S.2
Martin, A.J.3
-
79
-
-
34247574196
-
Comparison of Cartesian and radial balanced GTFE coronary MRA
-
[abstract]
-
Leiner T., Katsimaglis G., Kissinger K.V., et al. Comparison of Cartesian and radial balanced GTFE coronary MRA. [abstract]. J Cardiovasc Magn Reson 6 1 (2004) 75
-
(2004)
J Cardiovasc Magn Reson
, vol.6
, Issue.1
, pp. 75
-
-
Leiner, T.1
Katsimaglis, G.2
Kissinger, K.V.3
-
80
-
-
0034700239
-
Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging
-
Botnar R.M., Stuber M., Kissinger K.V., et al. Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging. Circulation 102 12 (2000) 2582-2587
-
(2000)
Circulation
, vol.102
, Issue.12
, pp. 2582-2587
-
-
Botnar, R.M.1
Stuber, M.2
Kissinger, K.V.3
-
81
-
-
0033302114
-
Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: initial experience
-
Zheng J., Li D., Bae K.T., et al. Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: initial experience. J Cardiovasc Magn Reson 1 1 (1999) 33-41
-
(1999)
J Cardiovasc Magn Reson
, vol.1
, Issue.1
, pp. 33-41
-
-
Zheng, J.1
Li, D.2
Bae, K.T.3
-
82
-
-
0031909558
-
Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography
-
Goldfarb J.W., and Edelman R.R. Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography. Radiology 206 3 (1998) 830-834
-
(1998)
Radiology
, vol.206
, Issue.3
, pp. 830-834
-
-
Goldfarb, J.W.1
Edelman, R.R.2
-
83
-
-
0042839674
-
Contrast-enhanced coronary artery imaging using 3D TrueFISP
-
Deshpande V., and Li D. Contrast-enhanced coronary artery imaging using 3D TrueFISP. Magn Reson Med 50 3 (2003) 570-577
-
(2003)
Magn Reson Med
, vol.50
, Issue.3
, pp. 570-577
-
-
Deshpande, V.1
Li, D.2
-
84
-
-
33745904454
-
Detection of coronary stenoses with contrast-enhanced, three-dimensional free-breathing coronary MR angiography using the gadolinium-based intravascular contrast agent gadocoletic acid (B-22956)
-
Paetsch I., Jahnke C., Barkhausen J., et al. Detection of coronary stenoses with contrast-enhanced, three-dimensional free-breathing coronary MR angiography using the gadolinium-based intravascular contrast agent gadocoletic acid (B-22956). J Cardiovasc Magn Reson 8 3 (2006) 509-516
-
(2006)
J Cardiovasc Magn Reson
, vol.8
, Issue.3
, pp. 509-516
-
-
Paetsch, I.1
Jahnke, C.2
Barkhausen, J.3
-
85
-
-
0032755672
-
Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography
-
Stuber M., Botnar R.M., Danias P.G., et al. Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography. J Magn Reson Imaging 10 5 (1999) 790-799
-
(1999)
J Magn Reson Imaging
, vol.10
, Issue.5
, pp. 790-799
-
-
Stuber, M.1
Botnar, R.M.2
Danias, P.G.3
-
86
-
-
0037227771
-
Performance of a new gadolinium-based intravascular contrast agent in free-breathing inversion-recovery 3D coronary MRA
-
Huber M.E., Paetsch I., Schnackenburg B., et al. Performance of a new gadolinium-based intravascular contrast agent in free-breathing inversion-recovery 3D coronary MRA. Magn Reson Med 49 1 (2003) 115-121
-
(2003)
Magn Reson Med
, vol.49
, Issue.1
, pp. 115-121
-
-
Huber, M.E.1
Paetsch, I.2
Schnackenburg, B.3
-
87
-
-
0141853040
-
Coronary arteries: contrast-enhanced MR imaging with SH L 643A-experience in 12 volunteers
-
Herborn C.U., Barkhausen J., Paetsch I., et al. Coronary arteries: contrast-enhanced MR imaging with SH L 643A-experience in 12 volunteers. Radiology 229 1 (2003) 217-223
-
(2003)
Radiology
, vol.229
, Issue.1
, pp. 217-223
-
-
Herborn, C.U.1
Barkhausen, J.2
Paetsch, I.3
-
88
-
-
0036890782
-
Multislice breath-hold spiral magnetic resonance coronary angiography in patients with coronary artery disease: effect of intravascular contrast medium
-
Knuesel P.R., Nanz D., Wolfensberger U., et al. Multislice breath-hold spiral magnetic resonance coronary angiography in patients with coronary artery disease: effect of intravascular contrast medium. J Magn Reson Imaging 16 6 (2002) 660-667
-
(2002)
J Magn Reson Imaging
, vol.16
, Issue.6
, pp. 660-667
-
-
Knuesel, P.R.1
Nanz, D.2
Wolfensberger, U.3
-
89
-
-
0032968339
-
Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography
-
Taylor A.M., Panting J.R., Keegan J., et al. Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging 9 2 (1999) 220-227
-
(1999)
J Magn Reson Imaging
, vol.9
, Issue.2
, pp. 220-227
-
-
Taylor, A.M.1
Panting, J.R.2
Keegan, J.3
-
90
-
-
0035014416
-
Breath-hold 3D MR coronary angiography with a new intravascular contrast agent (feruglose)-first clinical experiences
-
Sandstede J.J., Pabst T., Wacker C., et al. Breath-hold 3D MR coronary angiography with a new intravascular contrast agent (feruglose)-first clinical experiences. Magn Reson Imaging 19 2 (2001) 201-205
-
(2001)
Magn Reson Imaging
, vol.19
, Issue.2
, pp. 201-205
-
-
Sandstede, J.J.1
Pabst, T.2
Wacker, C.3
-
91
-
-
0033659567
-
Human cardiac imaging at 3 T using phased array coils
-
Noeske R., Seifert F., Rhein K.H., et al. Human cardiac imaging at 3 T using phased array coils. Magn Reson Med 44 6 (2000) 978-982
-
(2000)
Magn Reson Med
, vol.44
, Issue.6
, pp. 978-982
-
-
Noeske, R.1
Seifert, F.2
Rhein, K.H.3
-
92
-
-
0035142561
-
Cardiac susceptibility artifacts arising from the heart-lung interface
-
Atalay M.K., Poncelet B.P., Kantor H.L., et al. Cardiac susceptibility artifacts arising from the heart-lung interface. Magn Reson Med 45 2 (2001) 341-345
-
(2001)
Magn Reson Med
, vol.45
, Issue.2
, pp. 341-345
-
-
Atalay, M.K.1
Poncelet, B.P.2
Kantor, H.L.3
-
93
-
-
32544454469
-
Single breath-hold whole-heart MRA using variable density spirals at 3T
-
Santos J.M., Cunningham C.H., Lustig M., et al. Single breath-hold whole-heart MRA using variable density spirals at 3T. Magn Reson Med 55 2 (2006) 371-379
-
(2006)
Magn Reson Med
, vol.55
, Issue.2
, pp. 371-379
-
-
Santos, J.M.1
Cunningham, C.H.2
Lustig, M.3
-
94
-
-
12744268351
-
Coronary arteries at 3.0T: contrast-enhanced magnetization-prepared three-dimensional breath-hold MR angiography
-
Bi X., and Li D. Coronary arteries at 3.0T: contrast-enhanced magnetization-prepared three-dimensional breath-hold MR angiography. J Magn Reson Imaging 21 2 (2005) 133-139
-
(2005)
J Magn Reson Imaging
, vol.21
, Issue.2
, pp. 133-139
-
-
Bi, X.1
Li, D.2
-
95
-
-
0033301602
-
Safety of implantable coronary stents during 1H-magnetic resonance imaging at 1.0 and 1.5 T
-
Strohm O., Kivelitz D., Gross W., et al. Safety of implantable coronary stents during 1H-magnetic resonance imaging at 1.0 and 1.5 T. J Cardiovasc Magn Reson 1 3 (1999) 239-245
-
(1999)
J Cardiovasc Magn Reson
, vol.1
, Issue.3
, pp. 239-245
-
-
Strohm, O.1
Kivelitz, D.2
Gross, W.3
-
96
-
-
0034525189
-
Absence of adverse outcomes after magnetic resonance imaging early after stent placement for acute myocardial infarction: a preliminary study
-
Kramer C.M., Rogers Jr. W.J., and Pakstis D.L. Absence of adverse outcomes after magnetic resonance imaging early after stent placement for acute myocardial infarction: a preliminary study. J Cardiovasc Magn Reson 2 4 (2000) 257-261
-
(2000)
J Cardiovasc Magn Reson
, vol.2
, Issue.4
, pp. 257-261
-
-
Kramer, C.M.1
Rogers Jr., W.J.2
Pakstis, D.L.3
-
97
-
-
0141615770
-
Clinical safety of magnetic resonance imaging early after coronary artery stent placement
-
Gerber T.C., Fasseas P., Lennon R.J., et al. Clinical safety of magnetic resonance imaging early after coronary artery stent placement. J Am Coll Cardiol 42 7 (2003) 1295-1298
-
(2003)
J Am Coll Cardiol
, vol.42
, Issue.7
, pp. 1295-1298
-
-
Gerber, T.C.1
Fasseas, P.2
Lennon, R.J.3
-
98
-
-
0033836904
-
Coronary arterial stents: safety and artifacts during MR imaging
-
Hug J., Nagel E., Bornstedt, et al. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 216 3 (2000) 781-787
-
(2000)
Radiology
, vol.216
, Issue.3
, pp. 781-787
-
-
Hug, J.1
Nagel, E.2
Bornstedt3
-
99
-
-
0028364655
-
Absence of movement of coronary stents after placement in a magnetic resonance imaging field
-
Scott N.A., and Pettigrew R.I. Absence of movement of coronary stents after placement in a magnetic resonance imaging field. Am J Cardiol 73 12 (1994) 900-901
-
(1994)
Am J Cardiol
, vol.73
, Issue.12
, pp. 900-901
-
-
Scott, N.A.1
Pettigrew, R.I.2
-
100
-
-
0032866019
-
Metallic stents: evaluation of MR imaging safety
-
Shellock F.G., and Shellock V.J. Metallic stents: evaluation of MR imaging safety. AJR Am J Roentgenol 173 3 (1999) 543-547
-
(1999)
AJR Am J Roentgenol
, vol.173
, Issue.3
, pp. 543-547
-
-
Shellock, F.G.1
Shellock, V.J.2
-
101
-
-
34047250974
-
MR safety at 3-Tesla: bare metal and drug-eluting coronary artery stents
-
Shellock F.G. MR safety at 3-Tesla: bare metal and drug-eluting coronary artery stents. Signals 53 2 (2005) 26-27
-
(2005)
Signals
, vol.53
, Issue.2
, pp. 26-27
-
-
Shellock, F.G.1
-
102
-
-
0036367519
-
Coronary magnetic resonance angiography for assessment of the stent lumen: a phantom study
-
Maintz D.C., Botnar R.M., Fischbach R., et al. Coronary magnetic resonance angiography for assessment of the stent lumen: a phantom study. J Cardiovasc Magn Reson 4 3 (2002) 359-367
-
(2002)
J Cardiovasc Magn Reson
, vol.4
, Issue.3
, pp. 359-367
-
-
Maintz, D.C.1
Botnar, R.M.2
Fischbach, R.3
-
103
-
-
0037133176
-
Magnetic resonance-guided coronary artery stent placement in a swine model
-
Spuentrup E., Ruebben A., Schaeffter T., et al. Magnetic resonance-guided coronary artery stent placement in a swine model. Circulation 105 7 (2002) 874-879
-
(2002)
Circulation
, vol.105
, Issue.7
, pp. 874-879
-
-
Spuentrup, E.1
Ruebben, A.2
Schaeffter, T.3
-
104
-
-
35548978896
-
-
Meyer CH, Macovski A, Nishimura DG. Coronary vessel wall imaging [abstract]. Proc Inter Soc Magn Reson Med. Presented at the 6th Annual Meeting of the International Society of Magnetic Resonance in Medicine. Sydney, Australia, 1998. p. 15.
-
-
-
-
105
-
-
0034255293
-
Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging
-
Fayad Z.A., Fuster V., Fallon J.T., et al. Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 102 5 (2000) 506-510
-
(2000)
Circulation
, vol.102
, Issue.5
, pp. 506-510
-
-
Fayad, Z.A.1
Fuster, V.2
Fallon, J.T.3
-
106
-
-
0242583848
-
Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3Tesla
-
Botnar R.M., Stuber M., Lamerichs R., et al. Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3Tesla. J Cardiovasc Magn Reson 5 4 (2003) 589-594
-
(2003)
J Cardiovasc Magn Reson
, vol.5
, Issue.4
, pp. 589-594
-
-
Botnar, R.M.1
Stuber, M.2
Lamerichs, R.3
-
107
-
-
12744261207
-
Coronary artery wall imaging: initial experience at 3 Tesla
-
Koktzoglou I., Simonetti O., and Li D. Coronary artery wall imaging: initial experience at 3 Tesla. J Magn Reson Imaging 21 2 (2005) 128-132
-
(2005)
J Magn Reson Imaging
, vol.21
, Issue.2
, pp. 128-132
-
-
Koktzoglou, I.1
Simonetti, O.2
Li, D.3
-
108
-
-
34247552210
-
In vivo molecular MR imaging of acute coronary thrombosis using a fibrin-targeted contrast agent
-
[abstract]
-
Botnar R.M., Wiethoff A.J., Parsons Jr. E.C., et al. In vivo molecular MR imaging of acute coronary thrombosis using a fibrin-targeted contrast agent. [abstract]. J Cardiovasc Magn Reson 6 (2004) 109-110
-
(2004)
J Cardiovasc Magn Reson
, vol.6
, pp. 109-110
-
-
Botnar, R.M.1
Wiethoff, A.J.2
Parsons Jr., E.C.3
-
109
-
-
0034543128
-
Real-time projection MR angiography: feasibility study
-
Serfaty J.M., Atalar E., Declerck J., et al. Real-time projection MR angiography: feasibility study. Radiology 217 1 (2000) 290-295
-
(2000)
Radiology
, vol.217
, Issue.1
, pp. 290-295
-
-
Serfaty, J.M.1
Atalar, E.2
Declerck, J.3
-
110
-
-
0344305573
-
Catheter-directed contrast-enhanced coronary MR angiography in swine using magnetization-prepared True-FISP
-
Green J.D., Omary R.A., Schirf B.E., et al. Catheter-directed contrast-enhanced coronary MR angiography in swine using magnetization-prepared True-FISP. Magn Reson Med 50 6 (2003) 1317-1321
-
(2003)
Magn Reson Med
, vol.50
, Issue.6
, pp. 1317-1321
-
-
Green, J.D.1
Omary, R.A.2
Schirf, B.E.3
-
111
-
-
4944229996
-
Projection imaging of the right coronary artery with an intravenous injection of contrast agent
-
Green J.D., Schirf B.E., Omary R.A., et al. Projection imaging of the right coronary artery with an intravenous injection of contrast agent. Magn Reson Med 52 4 (2004) 699-703
-
(2004)
Magn Reson Med
, vol.52
, Issue.4
, pp. 699-703
-
-
Green, J.D.1
Schirf, B.E.2
Omary, R.A.3
-
112
-
-
33645791612
-
MR coronary angiography in pigs with intra-arterial injections of a hyperpolarized 13C substance
-
Olsson L.E., Chai C.M., Axelsson O., et al. MR coronary angiography in pigs with intra-arterial injections of a hyperpolarized 13C substance. Magn Reson Med 55 4 (2006) 731-737
-
(2006)
Magn Reson Med
, vol.55
, Issue.4
, pp. 731-737
-
-
Olsson, L.E.1
Chai, C.M.2
Axelsson, O.3
-
113
-
-
0027373560
-
Magnetic resonance imaging of coronary arteries: technique and preliminary results
-
Pennell D.J., Keegan J., Firmin D.N., et al. Magnetic resonance imaging of coronary arteries: technique and preliminary results. Br Heart J 70 4 (1993) 315-326
-
(1993)
Br Heart J
, vol.70
, Issue.4
, pp. 315-326
-
-
Pennell, D.J.1
Keegan, J.2
Firmin, D.N.3
-
114
-
-
0028036749
-
Two-dimensional coronary MR angiography: analysis of initial clinical results
-
Duerinckx A.J., and Urman M.K. Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology 193 3 (1994) 731-738
-
(1994)
Radiology
, vol.193
, Issue.3
, pp. 731-738
-
-
Duerinckx, A.J.1
Urman, M.K.2
-
115
-
-
0028085927
-
Breath-hold MR cine angiography of coronary arteries in healthy volunteers: value of multiangle oblique imaging planes
-
Sakuma H., Caputo G.R., Steffens J.C., et al. Breath-hold MR cine angiography of coronary arteries in healthy volunteers: value of multiangle oblique imaging planes. AJR Am J Roentgenol 163 3 (1994) 533-537
-
(1994)
AJR Am J Roentgenol
, vol.163
, Issue.3
, pp. 533-537
-
-
Sakuma, H.1
Caputo, G.R.2
Steffens, J.C.3
-
116
-
-
0028897927
-
MR angiography of the coronary arteries
-
Masui T., Isoda H., Mochizuki T., et al. MR angiography of the coronary arteries. Radiat Med 13 1 (1995) 47-50
-
(1995)
Radiat Med
, vol.13
, Issue.1
, pp. 47-50
-
-
Masui, T.1
Isoda, H.2
Mochizuki, T.3
-
117
-
-
0029999876
-
Magnetic resonance coronary angiography in heart transplant recipients
-
Davis S.F., Kannam J.P., Edelman R.R., et al. Magnetic resonance coronary angiography in heart transplant recipients. J Heart Lung Transplant 15 6 (1996) 580-586
-
(1996)
J Heart Lung Transplant
, vol.15
, Issue.6
, pp. 580-586
-
-
Davis, S.F.1
Kannam, J.P.2
Edelman, R.R.3
-
118
-
-
0031660282
-
Breath-hold coronary MR angiography with volume-targeted imaging
-
Wielopolski P.A., van Geuns R.J., de Feyter P.J., et al. Breath-hold coronary MR angiography with volume-targeted imaging. Radiology 209 1 (1998) 209-219
-
(1998)
Radiology
, vol.209
, Issue.1
, pp. 209-219
-
-
Wielopolski, P.A.1
van Geuns, R.J.2
de Feyter, P.J.3
-
119
-
-
0010483020
-
Validation of coronary artery MR angiography: comparison of measured vessel diameters with quantitative contrast angiography
-
[abstract]
-
Scheidegger M.B., Hess O.M., and Boesiger P. Validation of coronary artery MR angiography: comparison of measured vessel diameters with quantitative contrast angiography. [abstract]. Soc of Magnetic Reson: Book of Abstracts (1994) 497
-
(1994)
Soc of Magnetic Reson: Book of Abstracts
, pp. 497
-
-
Scheidegger, M.B.1
Hess, O.M.2
Boesiger, P.3
-
120
-
-
0016719586
-
Major variations in anatomical origin of the coronary arteries: angiographic observations in 4250 patients without associated congenital heart disease
-
Engel H.J., Torres C., and Page Jr. H.L. Major variations in anatomical origin of the coronary arteries: angiographic observations in 4250 patients without associated congenital heart disease. Cathet Cardiovasc Diagn 1 2 (1975) 157-169
-
(1975)
Cathet Cardiovasc Diagn
, vol.1
, Issue.2
, pp. 157-169
-
-
Engel, H.J.1
Torres, C.2
Page Jr., H.L.3
-
121
-
-
0016892217
-
Clinical, angiographic, and hemodynamic findings in patients with anomalous origin of the coronary arteries
-
Chaitman B.R., Lesperance J., Saltiel J., et al. Clinical, angiographic, and hemodynamic findings in patients with anomalous origin of the coronary arteries. Circulation 53 1 (1976) 122-131
-
(1976)
Circulation
, vol.53
, Issue.1
, pp. 122-131
-
-
Chaitman, B.R.1
Lesperance, J.2
Saltiel, J.3
-
122
-
-
33947728336
-
Coronary artery anomolies: an entity in search of an identity
-
Angelini P. Coronary artery anomolies: an entity in search of an identity. Circulation 115 10 (2007) 1296-1305
-
(2007)
Circulation
, vol.115
, Issue.10
, pp. 1296-1305
-
-
Angelini, P.1
-
123
-
-
0028791286
-
Identification of anomalous coronary arteries and their anatomic course by magnetic resonance coronary angiography
-
McConnell M.V., Ganz P., Selwyn A., et al. Identification of anomalous coronary arteries and their anatomic course by magnetic resonance coronary angiography. Circulation 92 11 (1995) 3158-3162
-
(1995)
Circulation
, vol.92
, Issue.11
, pp. 3158-3162
-
-
McConnell, M.V.1
Ganz, P.2
Selwyn, A.3
-
124
-
-
0028866518
-
Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course?
-
Post J.C., van Rossum A.C., Bronzwaer, et al. Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course?. Circulation 92 11 (1995) 3163-3171
-
(1995)
Circulation
, vol.92
, Issue.11
, pp. 3163-3171
-
-
Post, J.C.1
van Rossum, A.C.2
Bronzwaer3
-
125
-
-
0030951394
-
Value of fast gradient echo magnetic resonance angiography as an adjunct to coronary arteriography in detecting and confirming the course of clinically significant coronary artery anomalies
-
Vliegen H.W., Doornbos J., de Roos A., et al. Value of fast gradient echo magnetic resonance angiography as an adjunct to coronary arteriography in detecting and confirming the course of clinically significant coronary artery anomalies. Am J Cardiol 79 6 (1997) 773-776
-
(1997)
Am J Cardiol
, vol.79
, Issue.6
, pp. 773-776
-
-
Vliegen, H.W.1
Doornbos, J.2
de Roos, A.3
-
126
-
-
0034636113
-
Coronary artery imaging in grown-up congenital heart disease: complementary role of magnetic resonance and x-ray coronary angiography
-
Taylor A.M., Thorne S.A., Rubens M.B., et al. Coronary artery imaging in grown-up congenital heart disease: complementary role of magnetic resonance and x-ray coronary angiography. Circulation 101 14 (2000) 1670-1678
-
(2000)
Circulation
, vol.101
, Issue.14
, pp. 1670-1678
-
-
Taylor, A.M.1
Thorne, S.A.2
Rubens, M.B.3
-
127
-
-
0345726361
-
Coronary artery anomalies: assessment with free-breathing three-dimensional coronary MR angiography
-
Bunce N.H., Lorenz C.H., Keegan J., et al. Coronary artery anomalies: assessment with free-breathing three-dimensional coronary MR angiography. Radiology 227 1 (2003) 201-208
-
(2003)
Radiology
, vol.227
, Issue.1
, pp. 201-208
-
-
Bunce, N.H.1
Lorenz, C.H.2
Keegan, J.3
-
128
-
-
0000697598
-
Coronary magnetic resonance angiography (CMRA): the gold standard for determining the proximal course of anomalous coronary arteries
-
[abstract]
-
Razmi R.M., Chun W., Rathi V.K., et al. Coronary magnetic resonance angiography (CMRA): the gold standard for determining the proximal course of anomalous coronary arteries. [abstract]. J Am Coll Cardiol 37 (2001) 380
-
(2001)
J Am Coll Cardiol
, Issue.37
, pp. 380
-
-
Razmi, R.M.1
Chun, W.2
Rathi, V.K.3
-
129
-
-
34247642683
-
Exclusion of coronary artery anomalies in patients with congenital cardiovascular abnormalities using whole-heart approach
-
[abstract]
-
Setser R.M., Arruda J., Weaver J.A., et al. Exclusion of coronary artery anomalies in patients with congenital cardiovascular abnormalities using whole-heart approach. [abstract]. J Cardiovasc Magn Reson 9 2 (2007) 128-129
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, Issue.2
, pp. 128-129
-
-
Setser, R.M.1
Arruda, J.2
Weaver, J.A.3
-
130
-
-
34247636139
-
Feasibility of using free-breathing 3D whole-heart coronary MR angiography at 3T to assess coronary artery anomalies and variants
-
[abstract]
-
Gharib A.M., Ho V.B., Rosing D.R., et al. Feasibility of using free-breathing 3D whole-heart coronary MR angiography at 3T to assess coronary artery anomalies and variants. [abstract]. J Cardiovasc Magn Reson 9 2 (2007) 129-130
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, Issue.2
, pp. 129-130
-
-
Gharib, A.M.1
Ho, V.B.2
Rosing, D.R.3
-
131
-
-
33747016315
-
Visualization of coronary artery anomalies by contrast-enhanced multidetector rows spiral computed tomography
-
Schmid M., Achenbach S., Ludwig J., et al. Visualization of coronary artery anomalies by contrast-enhanced multidetector rows spiral computed tomography. Int J Cardiol 111 3 (2006) 430-435
-
(2006)
Int J Cardiol
, vol.111
, Issue.3
, pp. 430-435
-
-
Schmid, M.1
Achenbach, S.2
Ludwig, J.3
-
132
-
-
3442892339
-
Imaging of congenital coronary anomalies with multislice computed tomography
-
Deibler A.R., Kuzo R.S., Vohringer M., et al. Imaging of congenital coronary anomalies with multislice computed tomography. Mayo Clin Proc 79 8 (2004) 1017-1023
-
(2004)
Mayo Clin Proc
, vol.79
, Issue.8
, pp. 1017-1023
-
-
Deibler, A.R.1
Kuzo, R.S.2
Vohringer, M.3
-
133
-
-
0026539724
-
Outcome of coronary artery aneurysms after Kawasaki disease
-
Akagi T., Rose V., Benson L.N., et al. Outcome of coronary artery aneurysms after Kawasaki disease. J Pediatr 121 5 Pt 1 (1992) 689-694
-
(1992)
J Pediatr
, vol.121
, Issue.5 PART 1
, pp. 689-694
-
-
Akagi, T.1
Rose, V.2
Benson, L.N.3
-
134
-
-
0019935978
-
Fate of coronary aneurysms in Kawasaki disease: serial coronary angiography and long-term follow-up study
-
Kato H., Ichinose E., Yoshioka F., et al. Fate of coronary aneurysms in Kawasaki disease: serial coronary angiography and long-term follow-up study. Am J Cardiol 49 7 (1982) 1758-1766
-
(1982)
Am J Cardiol
, vol.49
, Issue.7
, pp. 1758-1766
-
-
Kato, H.1
Ichinose, E.2
Yoshioka, F.3
-
135
-
-
0037176970
-
Coronary magnetic resonance angiography in adolescents and young adults with Kawasaki disease
-
Greil G.F., Stuber M., Botnar R.M., et al. Coronary magnetic resonance angiography in adolescents and young adults with Kawasaki disease. Circulation 105 8 (2002) 908-911
-
(2002)
Circulation
, vol.105
, Issue.8
, pp. 908-911
-
-
Greil, G.F.1
Stuber, M.2
Botnar, R.M.3
-
136
-
-
10744221798
-
Magnetic resonance angiography is equivalent to x-ray coronary angiography for the evaluation of coronary arteries in Kawasaki disease
-
Mavrogeni S., Papadopoulos G., Douskou M., et al. Magnetic resonance angiography is equivalent to x-ray coronary angiography for the evaluation of coronary arteries in Kawasaki disease. J Am Coll Cardiol 43 4 (2004) 649-652
-
(2004)
J Am Coll Cardiol
, vol.43
, Issue.4
, pp. 649-652
-
-
Mavrogeni, S.1
Papadopoulos, G.2
Douskou, M.3
-
137
-
-
33745904455
-
Magnetic resonance angiography, function and viability evaluation in patients with Kawasaki disease
-
Mavrogeni S., Papadopoulos G., Douskou M., et al. Magnetic resonance angiography, function and viability evaluation in patients with Kawasaki disease. J Cardiovasc Magn Reson 8 4 (2006) 493-498
-
(2006)
J Cardiovasc Magn Reson
, vol.8
, Issue.4
, pp. 493-498
-
-
Mavrogeni, S.1
Papadopoulos, G.2
Douskou, M.3
-
138
-
-
1542373637
-
Correlation between magnetic resonance angiography (MRA) and quantitative coronary angiography (QCA) in ectatic coronary vessels
-
Mavrogeni S., Papadakis E., Foussas S., et al. Correlation between magnetic resonance angiography (MRA) and quantitative coronary angiography (QCA) in ectatic coronary vessels. J Cardiovasc Magn Reson 6 1 (2004) 17-23
-
(2004)
J Cardiovasc Magn Reson
, vol.6
, Issue.1
, pp. 17-23
-
-
Mavrogeni, S.1
Papadakis, E.2
Foussas, S.3
-
139
-
-
14944360212
-
Coronary magnetic resonance angiography for the detection of coronary stenoses
-
Kim W.Y., Danias P.G., Stuber M., et al. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345 26 (2001) 1863-1869
-
(2001)
N Engl J Med
, vol.345
, Issue.26
, pp. 1863-1869
-
-
Kim, W.Y.1
Danias, P.G.2
Stuber, M.3
-
140
-
-
0030028281
-
Assessment of coronary artery stenosis by magnetic resonance imaging
-
Pennell D.J., Bogren H.G., Keegan J., et al. Assessment of coronary artery stenosis by magnetic resonance imaging. Heart 75 2 (1996) 127-133
-
(1996)
Heart
, vol.75
, Issue.2
, pp. 127-133
-
-
Pennell, D.J.1
Bogren, H.G.2
Keegan, J.3
-
141
-
-
0031056691
-
Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease
-
Post J.C., van Rossum A.C., Hofman M.B., et al. Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease. Eur Heart J 18 3 (1997) 426-433
-
(1997)
Eur Heart J
, vol.18
, Issue.3
, pp. 426-433
-
-
Post, J.C.1
van Rossum, A.C.2
Hofman, M.B.3
-
142
-
-
0029351385
-
Clinical application of magnetic resonance angiography for coronary arteries: correlation with conventional angiography and evaluation of imaging time
-
Nitatori T., Hanaoka H., Yoshino A., et al. Clinical application of magnetic resonance angiography for coronary arteries: correlation with conventional angiography and evaluation of imaging time. Nippon Igaku Hoshasen Gakkai Zasshi 55 9 (1995) 670-676
-
(1995)
Nippon Igaku Hoshasen Gakkai Zasshi
, vol.55
, Issue.9
, pp. 670-676
-
-
Nitatori, T.1
Hanaoka, H.2
Yoshino, A.3
-
143
-
-
0032907360
-
Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography
-
Sandstede J.J., Pabst T., Beer M., et al. Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography. AJR Am J Roentgenol 172 1 (1999) 135-139
-
(1999)
AJR Am J Roentgenol
, vol.172
, Issue.1
, pp. 135-139
-
-
Sandstede, J.J.1
Pabst, T.2
Beer, M.3
-
144
-
-
34247561219
-
Comparison of spoiled TFE and balancedTFE coronary MR angiography
-
[abstract]
-
Ozgun M., Quante M., Kouwenhoven M., et al. Comparison of spoiled TFE and balancedTFE coronary MR angiography. [abstract]. J Cardiovasc Magn Reson 6 1 (2004) 268-269
-
(2004)
J Cardiovasc Magn Reson
, vol.6
, Issue.1
, pp. 268-269
-
-
Ozgun, M.1
Quante, M.2
Kouwenhoven, M.3
-
145
-
-
24644481147
-
Comparison of 3D segmented gradient-echo and steady-state free precession coronary MRI sequences in patients with coronary artery disease
-
Ozgun M., Hoffmeier A., Kouwenhoven M., et al. Comparison of 3D segmented gradient-echo and steady-state free precession coronary MRI sequences in patients with coronary artery disease. AJR Am J Roentgenol 185 1 (2005) 103-109
-
(2005)
AJR Am J Roentgenol
, vol.185
, Issue.1
, pp. 103-109
-
-
Ozgun, M.1
Hoffmeier, A.2
Kouwenhoven, M.3
-
146
-
-
4143114435
-
Coronary MR angiography with steady-state free precession: individually adapted breath-hold technique versus free-breathing technique
-
Jahnke C., Paetsch I., Schnackenburg B., et al. Coronary MR angiography with steady-state free precession: individually adapted breath-hold technique versus free-breathing technique. Radiology 232 3 (2004) 669-676
-
(2004)
Radiology
, vol.232
, Issue.3
, pp. 669-676
-
-
Jahnke, C.1
Paetsch, I.2
Schnackenburg, B.3
-
147
-
-
0031404187
-
Proximal coronary artery stenosis: three-dimensional MRI with fat saturation and navigator echo
-
Muller M.F., Fleisch M., Kroeker R., et al. Proximal coronary artery stenosis: three-dimensional MRI with fat saturation and navigator echo. J Magn Reson Imaging 7 4 (1997) 644-651
-
(1997)
J Magn Reson Imaging
, vol.7
, Issue.4
, pp. 644-651
-
-
Muller, M.F.1
Fleisch, M.2
Kroeker, R.3
-
148
-
-
0031940113
-
Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience
-
Woodard P.K., Li D., Haacke E.M., et al. Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience. AJR Am J Roentgenol 170 4 (1998) 883-888
-
(1998)
AJR Am J Roentgenol
, vol.170
, Issue.4
, pp. 883-888
-
-
Woodard, P.K.1
Li, D.2
Haacke, E.M.3
-
149
-
-
0032853832
-
Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique
-
van Geuns R.J., de Bruin H.G., Rensing B.J., et al. Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique. Heart 82 4 (1999) 515-519
-
(1999)
Heart
, vol.82
, Issue.4
, pp. 515-519
-
-
van Geuns, R.J.1
de Bruin, H.G.2
Rensing, B.J.3
-
150
-
-
0032966265
-
Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: results from healthy volunteers and patients with proximal coronary artery stenoses
-
Huber A., Nikolaou K., Gonschior P., et al. Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: results from healthy volunteers and patients with proximal coronary artery stenoses. AJR Am J Roentgenol 173 1 (1999) 95-101
-
(1999)
AJR Am J Roentgenol
, vol.173
, Issue.1
, pp. 95-101
-
-
Huber, A.1
Nikolaou, K.2
Gonschior, P.3
-
151
-
-
0034097058
-
Three-dimensional, navigator echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference
-
Sardanelli F., Molinari G., Zandrino F., et al. Three-dimensional, navigator echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference. Radiology 214 3 (2000) 808-814
-
(2000)
Radiology
, vol.214
, Issue.3
, pp. 808-814
-
-
Sardanelli, F.1
Molinari, G.2
Zandrino, F.3
-
152
-
-
0010516070
-
The assessment of coronary artery disease by combined magnetic resonance coronary arteriography and perfusion
-
[abstract]
-
Bunce N.R.S., Jhooti P., Lorenz C., et al. The assessment of coronary artery disease by combined magnetic resonance coronary arteriography and perfusion. [abstract]. J Cardiovasc Magn Reson 3 1 (2001) 118
-
(2001)
J Cardiovasc Magn Reson
, vol.3
, Issue.1
, pp. 118
-
-
Bunce, N.R.S.1
Jhooti, P.2
Lorenz, C.3
-
153
-
-
0000697595
-
Coronary magnetic resonance angiography using a free breathing, T2 weighted, three-dimensional gradient echo sequence with navigator respiratory and ECG gating used to detect coronary artery disease
-
[abstract]
-
Moustapha A.I., Muthupillai R., Wilson J., et al. Coronary magnetic resonance angiography using a free breathing, T2 weighted, three-dimensional gradient echo sequence with navigator respiratory and ECG gating used to detect coronary artery disease. [abstract]. J Am Coll Cardiol 37 Suppl (2001) 380
-
(2001)
J Am Coll Cardiol
, vol.37
, Issue.SUPPL
, pp. 380
-
-
Moustapha, A.I.1
Muthupillai, R.2
Wilson, J.3
-
154
-
-
0002780269
-
Submillimeter 3D coronary MR angiography with real-time navigator correction inn 112 patients with suspected coronary artery disease
-
[abstract]
-
Sommer T., Hofer U., Meyer C., et al. Submillimeter 3D coronary MR angiography with real-time navigator correction inn 112 patients with suspected coronary artery disease. [abstract]. J Cardiovasc Magn Reson 4 1 (2002) 28
-
(2002)
J Cardiovasc Magn Reson
, vol.4
, Issue.1
, pp. 28
-
-
Sommer, T.1
Hofer, U.2
Meyer, C.3
-
155
-
-
0037370055
-
Coronary artery imaging with real-time navigator three-dimensional turbo-field-echo MR coronary angiography: initial experience
-
Bogaert J., Kuzo R., Dymarkowski S., et al. Coronary artery imaging with real-time navigator three-dimensional turbo-field-echo MR coronary angiography: initial experience. Radiology 226 3 (2003) 707-716
-
(2003)
Radiology
, vol.226
, Issue.3
, pp. 707-716
-
-
Bogaert, J.1
Kuzo, R.2
Dymarkowski, S.3
-
156
-
-
0036788357
-
Coronary artery disease: assessment with a comprehensive MR imaging protocol-initial results
-
Plein S., Radjenovic A., Ridgway J.P., et al. Coronary artery disease: assessment with a comprehensive MR imaging protocol-initial results. Radiology 225 1 (2002) 300-307
-
(2002)
Radiology
, vol.225
, Issue.1
, pp. 300-307
-
-
Plein, S.1
Radjenovic, A.2
Ridgway, J.P.3
-
157
-
-
33646171174
-
Combination of free-breathing and breath-hold steady-state free precession magnetic resonance angiography for detection of coronary artery stenoses
-
Dewey M., Teige F., Schnapauff D., et al. Combination of free-breathing and breath-hold steady-state free precession magnetic resonance angiography for detection of coronary artery stenoses. J Magn Reson Imaging 23 5 (2006) 674-681
-
(2006)
J Magn Reson Imaging
, vol.23
, Issue.5
, pp. 674-681
-
-
Dewey, M.1
Teige, F.2
Schnapauff, D.3
-
158
-
-
33748466768
-
Discrimination of ischemic vs. nonischemic cardiomyopathy among patients with heart failure using combined coronary MRI and delayed enhancement MR
-
[abstract]
-
Hauser T.H., Yeon S.B., Appelbaum E., et al. Discrimination of ischemic vs. nonischemic cardiomyopathy among patients with heart failure using combined coronary MRI and delayed enhancement MR. [abstract]. J Cardiovasc Magn Reson 7 1 (2005) 94
-
(2005)
J Cardiovasc Magn Reson
, vol.7
, Issue.1
, pp. 94
-
-
Hauser, T.H.1
Yeon, S.B.2
Appelbaum, E.3
-
159
-
-
27544463754
-
Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance
-
Jahnke C., Paetsch I., Nehrke K., et al. Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance. Eur Heart J 26 21 (2005) 2313-2319
-
(2005)
Eur Heart J
, vol.26
, Issue.21
, pp. 2313-2319
-
-
Jahnke, C.1
Paetsch, I.2
Nehrke, K.3
-
160
-
-
10644288594
-
Coronary artery stenosis: direct comparison of four section multidetector row CT and three-dimensional navigator MR imaging for detection-initial results
-
Gerber B.L., Coche E., Pasquet A., et al. Coronary artery stenosis: direct comparison of four section multidetector row CT and three-dimensional navigator MR imaging for detection-initial results. Radiology 234 1 (2005) 98-108
-
(2005)
Radiology
, vol.234
, Issue.1
, pp. 98-108
-
-
Gerber, B.L.1
Coche, E.2
Pasquet, A.3
-
161
-
-
0023626729
-
Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts
-
Rubinstein R.I., Askenase A.D., Thickman D., et al. Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts. Circulation 76 4 (1987) 786-791
-
(1987)
Circulation
, vol.76
, Issue.4
, pp. 786-791
-
-
Rubinstein, R.I.1
Askenase, A.D.2
Thickman, D.3
-
162
-
-
0023866355
-
Detection of coronary artery bypass graft patency as assessed by magnetic resonance imaging
-
Jenkins J.P., Love H.G., Foster C.J., et al. Detection of coronary artery bypass graft patency as assessed by magnetic resonance imaging. Br J Radiol 61 721 (1988) 2-4
-
(1988)
Br J Radiol
, vol.61
, Issue.721
, pp. 2-4
-
-
Jenkins, J.P.1
Love, H.G.2
Foster, C.J.3
-
163
-
-
21344469283
-
Head-to-head comparison of three-dimensional navigator-gated magnetic resonance imaging and 16-slice computed tomography to detect coronary artery stenosis in patients
-
Kefer J., Coche E., Legros G., et al. Head-to-head comparison of three-dimensional navigator-gated magnetic resonance imaging and 16-slice computed tomography to detect coronary artery stenosis in patients. J Am Coll Cardiol 46 1 (2005) 92-100
-
(2005)
J Am Coll Cardiol
, vol.46
, Issue.1
, pp. 92-100
-
-
Kefer, J.1
Coche, E.2
Legros, G.3
-
164
-
-
33749174732
-
Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging
-
Dewey M., Teige F., Schnapauff D., et al. Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging. Ann Intern Med 145 6 (2006) 407-415
-
(2006)
Ann Intern Med
, vol.145
, Issue.6
, pp. 407-415
-
-
Dewey, M.1
Teige, F.2
Schnapauff, D.3
-
165
-
-
0024423739
-
Saphenous vein graft patency 1 year after coronary artery bypass surgery and effects of antiplatelet therapy. Results of a Veterans Administration cooperative study
-
Goldman S., Copeland J., Moritz T., et al. Saphenous vein graft patency 1 year after coronary artery bypass surgery and effects of antiplatelet therapy. Results of a Veterans Administration cooperative study. Circulation 80 5 (1989) 1190-1197
-
(1989)
Circulation
, vol.80
, Issue.5
, pp. 1190-1197
-
-
Goldman, S.1
Copeland, J.2
Moritz, T.3
-
166
-
-
0030245599
-
Coronary bypass graft fate and patient outcome: angiographic follow-up of 5065 grafts related to survival and reoperation in 1388 patients during 25 years
-
Fitzgibbon G.M., Kafka H.P., Leach A.J., et al. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5065 grafts related to survival and reoperation in 1388 patients during 25 years. J Am Coll Cardiol 28 3 (1996) 616-626
-
(1996)
J Am Coll Cardiol
, vol.28
, Issue.3
, pp. 616-626
-
-
Fitzgibbon, G.M.1
Kafka, H.P.2
Leach, A.J.3
-
167
-
-
0034543127
-
MR coronary angiography with breath-hold targeted volumes: preliminary clinical results
-
van Geuns R.J., Wielopolski P.A., de Bruin H.G., et al. MR coronary angiography with breath-hold targeted volumes: preliminary clinical results. Radiology 217 1 (2000) 270-277
-
(2000)
Radiology
, vol.217
, Issue.1
, pp. 270-277
-
-
van Geuns, R.J.1
Wielopolski, P.A.2
de Bruin, H.G.3
-
168
-
-
0023252971
-
Coronary artery bypass graft patency: noninvasive evaluation with MR imaging
-
White R.D., Caputo G.R., Mark A.S., et al. Coronary artery bypass graft patency: noninvasive evaluation with MR imaging. Radiology 164 3 (1987) 681-686
-
(1987)
Radiology
, vol.164
, Issue.3
, pp. 681-686
-
-
White, R.D.1
Caputo, G.R.2
Mark, A.S.3
-
169
-
-
0023883415
-
Coronary artery bypass grafts: evaluation of patency with cine MR imaging
-
White R.D., Pflugfelder P.W., Lipton M.J., et al. Coronary artery bypass grafts: evaluation of patency with cine MR imaging. AJR Am J Roentgenol 150 6 (1988) 1271-1274
-
(1988)
AJR Am J Roentgenol
, vol.150
, Issue.6
, pp. 1271-1274
-
-
White, R.D.1
Pflugfelder, P.W.2
Lipton, M.J.3
-
170
-
-
0030049876
-
Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study
-
Galjee M.A., van Rossum A.C., Doesburg T., et al. Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study. Circulation 93 4 (1996) 660-666
-
(1996)
Circulation
, vol.93
, Issue.4
, pp. 660-666
-
-
Galjee, M.A.1
van Rossum, A.C.2
Doesburg, T.3
-
171
-
-
0024807123
-
Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging
-
Aurigemma G.P., Reichek N., Axel L., et al. Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging. Circulation 80 6 (1989) 1595-1602
-
(1989)
Circulation
, vol.80
, Issue.6
, pp. 1595-1602
-
-
Aurigemma, G.P.1
Reichek, N.2
Axel, L.3
-
172
-
-
0033758102
-
Noninvasive coronary bypass graft imaging after multivessel revascularisation
-
Engelmann M.G., Knez A., von Smekal A., et al. Noninvasive coronary bypass graft imaging after multivessel revascularisation. Int J Cardiol 76 1 (2000) 65-74
-
(2000)
Int J Cardiol
, vol.76
, Issue.1
, pp. 65-74
-
-
Engelmann, M.G.1
Knez, A.2
von Smekal, A.3
-
173
-
-
0033646137
-
Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass grafts
-
Molinari G., Sardanelli F., Zandrino F., et al. Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass grafts. Int J Card Imaging 16 3 (2000) 149-160
-
(2000)
Int J Card Imaging
, vol.16
, Issue.3
, pp. 149-160
-
-
Molinari, G.1
Sardanelli, F.2
Zandrino, F.3
-
174
-
-
0031877299
-
Patency of coronary bypass grafts: assessment with breath-hold contrast-enhanced MR angiography-value of a nonelectrocardiographically triggered technique
-
Wintersperger B.J., Engelmann M.G., von Smekal A., et al. Patency of coronary bypass grafts: assessment with breath-hold contrast-enhanced MR angiography-value of a nonelectrocardiographically triggered technique. Radiology 208 2 (1998) 345-351
-
(1998)
Radiology
, vol.208
, Issue.2
, pp. 345-351
-
-
Wintersperger, B.J.1
Engelmann, M.G.2
von Smekal, A.3
-
175
-
-
0030911958
-
Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts
-
Vrachliotis T.G., Bis K.G., Aliabadi D., et al. Contrast-enhanced breath-hold MR angiography for evaluating patency of coronary artery bypass grafts. AJR Am J Roentgenol 168 4 (1997) 1073-1080
-
(1997)
AJR Am J Roentgenol
, vol.168
, Issue.4
, pp. 1073-1080
-
-
Vrachliotis, T.G.1
Bis, K.G.2
Aliabadi, D.3
-
176
-
-
0242585292
-
Coronary artery bypass graft patency: assessment with true ast imaging with steady-state precession versus gadolinium-enhanced MR angiography
-
Bunce N.H., Lorenz C.H., John A.S., et al. Coronary artery bypass graft patency: assessment with true ast imaging with steady-state precession versus gadolinium-enhanced MR angiography. Radiology 227 2 (2003) 440-446
-
(2003)
Radiology
, vol.227
, Issue.2
, pp. 440-446
-
-
Bunce, N.H.1
Lorenz, C.H.2
John, A.S.3
-
177
-
-
0036136003
-
MR flow mapping in coronary artery bypass grafts: a validation study with Doppler flow measurements
-
Langerak S.E., Kunz P., Vliegen H.W., et al. MR flow mapping in coronary artery bypass grafts: a validation study with Doppler flow measurements. Radiology 222 1 (2002) 127-135
-
(2002)
Radiology
, vol.222
, Issue.1
, pp. 127-135
-
-
Langerak, S.E.1
Kunz, P.2
Vliegen, H.W.3
-
178
-
-
0037465864
-
Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries
-
Langerak S.E., Vliegen H.W., Jukema J.W., et al. Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries. Circulation 107 11 (2003) 1502-1508
-
(2003)
Circulation
, vol.107
, Issue.11
, pp. 1502-1508
-
-
Langerak, S.E.1
Vliegen, H.W.2
Jukema, J.W.3
|