Volumn 52, Issue 1, 2004, Pages 7-13

Feasibility and performance of breath-hold 3D TRUE-FISP coronary MRA using self-calibrating parallel acquisition

Author keywords

Coronary arteries; Magnetic resonance imaging; MR angiography; Parallel MRI; True FISP

Indexed keywords

ANGIOGRAPHY; CALIBRATION; DATA ACQUISITION; HEART; IMAGE RESOLUTION; MAGNETIC RESONANCE IMAGING;

EID: 4644225120     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20153     Document Type: Article
Times cited : (14)

References (19)
  • 2
    • 0035152560 scopus 로고    scopus 로고
    • Coronary artery imaging: 3D segmented k-space data acquisition with multiple breath-holds and real-time slab following
    • Shea SM, Kroeker RM, Deshpande V, Laub G, Zheng J, Finn JP, Li D. Coronary artery imaging: 3D segmented k-space data acquisition with multiple breath-holds and real-time slab following. J Magn Reson Imaging 2001;13:301-307.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 301-307
    • Shea, S.M.1    Kroeker, R.M.2    Deshpande, V.3    Laub, G.4    Zheng, J.5    Finn, J.P.6    Li, D.7
  • 3
    • 0035084261 scopus 로고    scopus 로고
    • Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography
    • Li D, Carr JC, Shea SM, Zheng J, Deshpande VS, Wielopolski PA, Finn JP. Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography. Radiology 2001;219:270-277.
    • (2001) Radiology , vol.219 , pp. 270-277
    • Li, D.1    Carr, J.C.2    Shea, S.M.3    Zheng, J.4    Deshpande, V.S.5    Wielopolski, P.A.6    Finn, J.P.7
  • 8
    • 0032425458 scopus 로고    scopus 로고
    • AUTO-SMASH: A self-calibrating technique for SMASH imaging. Simultaneous acquisition of spatial harmonics
    • Jakob PM, Griswold MA, Edelman RR, Sodickson DK. AUTO-SMASH: a self-calibrating technique for SMASH imaging. Simultaneous acquisition of spatial harmonics. MAGMA 1998;7:42-54.
    • (1998) MAGMA , vol.7 , pp. 42-54
    • Jakob, P.M.1    Griswold, M.A.2    Edelman, R.R.3    Sodickson, D.K.4
  • 11
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 12
    • 0033856106 scopus 로고    scopus 로고
    • Tailored SMASH image reconstructions for robust in vivo parallel MR imaging
    • Sodickson DK. Tailored SMASH image reconstructions for robust in vivo parallel MR imaging. Magn Reson Med 2000;44:243-251.
    • (2000) Magn Reson Med , vol.44 , pp. 243-251
    • Sodickson, D.K.1
  • 13
    • 0034845169 scopus 로고    scopus 로고
    • A generalized approach to parallel magnetic resonance imaging
    • Sodickson DK, McKenzie CA. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001;28:1629-1643.
    • (2001) Med Phys , vol.28 , pp. 1629-1643
    • Sodickson, D.K.1    McKenzie, C.A.2
  • 14
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4
  • 17
    • 0036135913 scopus 로고    scopus 로고
    • Impact of navigator timing on free-breathing submillimeter 3D coronary magnetic resonance angiography
    • Spuentrup E, Manning WJ, Botnar RM, Kissinger KV, Stuber M. Impact of navigator timing on free-breathing submillimeter 3D coronary magnetic resonance angiography. Magn Reson Med 2002;47:196-201.
    • (2002) Magn Reson Med , vol.47 , pp. 196-201
    • Spuentrup, E.1    Manning, W.J.2    Botnar, R.M.3    Kissinger, K.V.4    Stuber, M.5
  • 18
    • 0034877825 scopus 로고    scopus 로고
    • The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography
    • Spuentrup E, Stuber M, Botnar RM, Manning WJ. The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography. J Magn Reson Imaging 2001;14:311-318.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 311-318
    • Spuentrup, E.1    Stuber, M.2    Botnar, R.M.3    Manning, W.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.