메뉴 건너뛰기




Volumn 16, Issue 6, 2002, Pages 660-667

Multislice breath-hold spiral magnetic resonance coronary angiography in patients with coronary artery disease: Effect of intravascular contrast medium

Author keywords

Coronary artery disease; Intravascular contrast medium; Magnetic resonance coronary angiography; Spiral MR imaging; Ultrasmall superparamagnetic iron oxide crystals

Indexed keywords

CONTRAST MEDIUM; ULTRASMALL SUPERPARAMAGNETIC IRON OXIDE;

EID: 0036890782     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.10202     Document Type: Article
Times cited : (16)

References (25)
  • 1
    • 0027403101 scopus 로고
    • A preliminary report comparing magnetic resonance coronary angiography with conventional angiography
    • Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 1993:328:828-832.
    • (1993) N Engl J Med , vol.328 , pp. 828-832
    • Manning, W.J.1    Li, W.2    Edelman, R.R.3
  • 2
    • 0034543127 scopus 로고    scopus 로고
    • MR coronary angiography with breath-hold targeted volumes: Preliminary clinical results
    • Van Geuns RJM, Wielopolski PA, De Bruin HG, et al. MR coronary angiography with breath-hold targeted volumes: Preliminary clinical results. Radiology 2000;217:270-277.
    • (2000) Radiology , vol.217 , pp. 270-277
    • Van Geuns, R.J.M.1    Wielopolski, P.A.2    De Bruin, H.G.3
  • 3
    • 0031724906 scopus 로고    scopus 로고
    • Two-dimensional multishot echo-planar coronary MR angiography
    • Slavin GS, Riederer SJ, Ehman RL. Two-dimensional multishot echo-planar coronary MR angiography. Magn Reson Med 1998;40:883-889.
    • (1998) Magn Reson Med , vol.40 , pp. 883-889
    • Slavin, G.S.1    Riederer, S.J.2    Ehman, R.L.3
  • 5
    • 0035163255 scopus 로고    scopus 로고
    • Improved 3D spiral imaging for coronary MR angiography
    • Börnert P, Aldefeld B, Nehrke K. Improved 3D spiral imaging for coronary MR angiography. Magn Reson Med 2001:45:172-175.
    • (2001) Magn Reson Med , vol.45 , pp. 172-175
    • Börnert, P.1    Aldefeld, B.2    Nehrke, K.3
  • 6
    • 0033005781 scopus 로고    scopus 로고
    • Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse
    • Hofman MB, Henson RE, Kovacs SJ, et al. Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse. Magn Reson Med 1999;41:360-367.
    • (1999) Magn Reson Med , vol.41 , pp. 360-367
    • Hofman, M.B.1    Henson, R.E.2    Kovacs, S.J.3
  • 7
    • 0031809104 scopus 로고    scopus 로고
    • Three-dimensional MRI of coronary arteries using an intravascular contrast agent
    • Li D, Dolan RP, Walovitch RC, Lauffer RB. Three-dimensional MRI of coronary arteries using an intravascular contrast agent. Magn Reson Med 1998;39:1014-1018.
    • (1998) Magn Reson Med , vol.39 , pp. 1014-1018
    • Li, D.1    Dolan, R.P.2    Walovitch, R.C.3    Lauffer, R.B.4
  • 8
    • 0032755672 scopus 로고    scopus 로고
    • Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography
    • Stuber M, Botnar RM, Danias PG, et al. Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography. J Magn Reson Imaging 1999;10:790-799.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 790-799
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3
  • 9
    • 0034762978 scopus 로고    scopus 로고
    • Coronary magnetic resonance angiography: Experimental evaluation of the new rapid clearance blood pool contrast medium P792
    • Taupitz M, Schnorr J, Wagner S, et al. Coronary magnetic resonance angiography: experimental evaluation of the new rapid clearance blood pool contrast medium P792. Magn Reson Med 2001;46:932-938.
    • (2001) Magn Reson Med , vol.46 , pp. 932-938
    • Taupitz, M.1    Schnorr, J.2    Wagner, S.3
  • 10
    • 0033302114 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: Initial experience
    • Zheng J, Li D, Kyongtae T, Woodard P, Haacke EM. Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: Initial experience. J Cardiovasc Magn Res 1999;1:33-41
    • (1999) J Cardiovasc Magn Res , vol.1 , pp. 33-41
    • Zheng, J.1    Li, D.2    Kyongtae, T.3    Woodard, P.4    Haacke, E.M.5
  • 11
    • 0031860874 scopus 로고    scopus 로고
    • Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification
    • Hofman MB. Wickline SA, Lorenz CH. Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification. J Magn Reson Imaging 1998;8:568-576.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 568-576
    • Hofman, M.B.1    Wickline, S.A.2    Lorenz, C.H.3
  • 12
    • 0032719272 scopus 로고    scopus 로고
    • Cardiac motion of coronary arteries: Variability in the rest period and implications for coronary MR angiography
    • Wang Y, Vidan E, Bergman G. Cardiac motion of coronary arteries: Variability in the rest period and implications for coronary MR angiography. Radiology 1999;213:751-758.
    • (1999) Radiology , vol.213 , pp. 751-758
    • Wang, Y.1    Vidan, E.2    Bergman, G.3
  • 13
    • 0032968339 scopus 로고    scopus 로고
    • Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography
    • Taylor AM, Panting JR, Keegan J, et al. Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging 1999;9:220-227.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 220-227
    • Taylor, A.M.1    Panting, J.R.2    Keegan, J.3
  • 14
    • 0025111082 scopus 로고
    • Validation of a new automatic system for biplane quantitative coronary arteriography
    • Buchi M, Hess OM, Kirkeeide RL, et al. Validation of a new automatic system for biplane quantitative coronary arteriography. Int J Card Imaging 1990;5:93-103.
    • (1990) Int J Card Imaging , vol.5 , pp. 93-103
    • Buchi, M.1    Hess, O.M.2    Kirkeeide, R.L.3
  • 15
    • 0027395731 scopus 로고
    • Fat-suppressed breath-hold magnetic resonance coronary angiography
    • Manning WJ, Li W, Boyle NG, Edelman RR. Fat-suppressed breath-hold magnetic resonance coronary angiography. Circulation 1993;87:94-104.
    • (1993) Circulation , vol.87 , pp. 94-104
    • Manning, W.J.1    Li, W.2    Boyle, N.G.3    Edelman, R.R.4
  • 16
    • 0033910516 scopus 로고    scopus 로고
    • Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography
    • Regenfus M, Ropers D, Achenbach S, et al. Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography. J Am Coll Cardiol 2000;36:44-50.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 44-50
    • Regenfus, M.1    Ropers, D.2    Achenbach, S.3
  • 17
    • 0034097058 scopus 로고    scopus 로고
    • Three-dimensional navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference
    • Sardanelli F, Molinari G, Zandrino F, Balbi M. Three-dimensional navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference. Radiology 2000;214:808-814.
    • (2000) Radiology , vol.214 , pp. 808-814
    • Sardanelli, F.1    Molinari, G.2    Zandrino, F.3    Balbi, M.4
  • 18
    • 0032747628 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the coronary arteries: Techniques and results
    • van Geuns RJ, Wielopolski PA, de Bruin HG, et al. Magnetic resonance imaging of the coronary arteries: Techniques and results. Prog Cardiovasc Dis 1999;42:157-166.
    • (1999) Prog Cardiovasc Dis , vol.42 , pp. 157-166
    • Van Geuns, R.J.1    Wielopolski, P.A.2    De Bruin, H.G.3
  • 19
    • 0032966265 scopus 로고    scopus 로고
    • Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Results from healthy volunteers and patients with proximal coronary artery stenoses
    • Huber A, Nikolaou K, Gonschior P, et al. Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Results from healthy volunteers and patients with proximal coronary artery stenoses. AJR Am J Roentgenol 1999;173:95-101.
    • (1999) AJR Am J Roentgenol , vol.173 , pp. 95-101
    • Huber, A.1    Nikolaou, K.2    Gonschior, P.3
  • 20
    • 0033594967 scopus 로고    scopus 로고
    • Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    • Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 1998;99:3139-3148.
    • (1998) Circulation , vol.99 , pp. 3139-3148
    • Botnar, R.M.1    Stuber, M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 21
    • 14944360212 scopus 로고    scopus 로고
    • Coronary MR angiography for the detection of coronary stenoses
    • Kim WY, Danias PG, Stuber M, et al. Coronary MR angiography for the detection of coronary stenoses. N Engl J Med 2001;345:1863-1869.
    • (2001) N Engl J Med , vol.345 , pp. 1863-1869
    • Kim, W.Y.1    Danias, P.G.2    Stuber, M.3
  • 22
    • 0031788545 scopus 로고    scopus 로고
    • Diaphragmatic and cardiac motion during suspended breathing: Preliminary experience and implications for breath-hold MR imaging
    • Holland AE, Goldfarb JW, Edelman RR. Diaphragmatic and cardiac motion during suspended breathing: Preliminary experience and implications for breath-hold MR imaging. Radiology 1998;209:483-489.
    • (1998) Radiology , vol.209 , pp. 483-489
    • Holland, A.E.1    Goldfarb, J.W.2    Edelman, R.R.3
  • 23
    • 0032932986 scopus 로고    scopus 로고
    • Benefit of T1 reduction for magnetic resonance coronary angiography: A numerical simulation and phantom study
    • Johansson LO, Fischer SE, Lorenz CH. Benefit of T1 reduction for magnetic resonance coronary angiography: A numerical simulation and phantom study. J Magn Reson Imaging 1999;9:552-556.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 552-556
    • Johansson, L.O.1    Fischer, S.E.2    Lorenz, C.H.3
  • 25
    • 0032900232 scopus 로고    scopus 로고
    • Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging - Initial experience
    • Kessler W, Laub G, Achenbach S, et al. Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging - Initial experience. Radiology 1999;210:566-572.
    • (1999) Radiology , vol.210 , pp. 566-572
    • Kessler, W.1    Laub, G.2    Achenbach, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.