메뉴 건너뛰기




Volumn 21, Issue 2, 2005, Pages 128-132

Coronary artery wall imaging: Initial experience at 3 Tesla

Author keywords

Black blood; Coronary artery; High field imaging; Magnetic resonance imaging (MRI); Vessel wall imaging

Indexed keywords

ADULT; ARTERY DIAMETER; ARTERY WALL; ARTICLE; ATHEROSCLEROTIC PLAQUE; BREATH HOLDING; BREATHING; CALCULATION; ELECTROCARDIOGRAM; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; LEFT ANTERIOR DESCENDING CORONARY ARTERY; MALE; MEASUREMENT; NEUROIMAGING; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PRIORITY JOURNAL; RADIOFREQUENCY; SIGNAL NOISE RATIO; WHOLE BODY SCANNER;

EID: 12744261207     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20232     Document Type: Article
Times cited : (35)

References (12)
  • 1
    • 0034255293 scopus 로고    scopus 로고
    • Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging
    • Fayad ZA, Fuster V, Fallon JT, et al. Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 2000;102:506-510.
    • (2000) Circulation , vol.102 , pp. 506-510
    • Fayad, Z.A.1    Fuster, V.2    Fallon, J.T.3
  • 3
    • 0035146394 scopus 로고    scopus 로고
    • Three-dimensional high-resolution fast spin-echo coronary magnetic resonance angiography
    • Stuber M, Botnar RM, Spuentrup E, Kissinger KV, Manning WJ. Three-dimensional high-resolution fast spin-echo coronary magnetic resonance angiography. Magn Reson Med 2001;45:206-211.
    • (2001) Magn Reson Med , vol.45 , pp. 206-211
    • Stuber, M.1    Botnar, R.M.2    Spuentrup, E.3    Kissinger, K.V.4    Manning, W.J.5
  • 4
    • 0036708122 scopus 로고    scopus 로고
    • Preliminary report on in vivo coronary MRA at 3 Tesla in humans
    • Stuber M, Botnar RM, Fischer SE, et al. Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 2002;48:425-429.
    • (2002) Magn Reson Med , vol.48 , pp. 425-429
    • Stuber, M.1    Botnar, R.M.2    Fischer, S.E.3
  • 5
    • 0242583848 scopus 로고    scopus 로고
    • Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 Tesla
    • Botnar RM, Stuber M, Lamerichs R, et al. Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 Tesla. J Cardiovasc Magn Reson 2003;5:589-594.
    • (2003) J Cardiovasc Magn Reson , vol.5 , pp. 589-594
    • Botnar, R.M.1    Stuber, M.2    Lamerichs, R.3
  • 6
    • 0031083548 scopus 로고    scopus 로고
    • The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5. 3, and 4 T
    • Wen H, Denison TJ, Singerman RW, Balaban RS. The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5. 3, and 4 T. J Magn Reson 1997;125:65-71.
    • (1997) J Magn Reson , vol.125 , pp. 65-71
    • Wen, H.1    Denison, T.J.2    Singerman, R.W.3    Balaban, R.S.4
  • 7
    • 0038050726 scopus 로고    scopus 로고
    • Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T
    • Greenman RL, Shirosky JE, Mulkern RV, Rofsky NM. Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T. J Magn Reson Imaging 2003;17:648-655.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 648-655
    • Greenman, R.L.1    Shirosky, J.E.2    Mulkern, R.V.3    Rofsky, N.M.4
  • 8
    • 0029978378 scopus 로고    scopus 로고
    • "Black blood" T2-weighted inversion-recovery MR imaging of the heart
    • Simonetti OP, Finn JP, White RD, Laub G, Henry DA. "Black blood" T2-weighted inversion-recovery MR imaging of the heart. Radiology 1996;199:49-57.
    • (1996) Radiology , vol.199 , pp. 49-57
    • Simonetti, O.P.1    Finn, J.P.2    White, R.D.3    Laub, G.4    Henry, D.A.5
  • 10
    • 0033660024 scopus 로고    scopus 로고
    • Easy improvement of signal-to-noise in RARE-sequences with low refocusing flip angles. Rapid acquisition with relaxation enhancement
    • Hennig J, Scheffler K. Easy improvement of signal-to-noise in RARE-sequences with low refocusing flip angles. Rapid acquisition with relaxation enhancement. Magn Reson Med 2000;44:983-985.
    • (2000) Magn Reson Med , vol.44 , pp. 983-985
    • Hennig, J.1    Scheffler, K.2
  • 11
    • 0032745137 scopus 로고    scopus 로고
    • Relationship between motion of coronary arteries and diaphragm during free breathing: Lessons from real-time MR imaging
    • Danias PG, Stuber M, Botnar RM, Kissinger KV, Edelman RR, Manning WJ. Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging. AJR Am J Roentgenol 1999;172:1061-1065.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 1061-1065
    • Danias, P.G.1    Stuber, M.2    Botnar, R.M.3    Kissinger, K.V.4    Edelman, R.R.5    Manning, W.J.6
  • 12
    • 0031022460 scopus 로고    scopus 로고
    • The sensitivity of low flip angle RARE imaging
    • Alsop DC. The sensitivity of low flip angle RARE imaging. Magn Reson Med 1997;37:176-184.
    • (1997) Magn Reson Med , vol.37 , pp. 176-184
    • Alsop, D.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.