메뉴 건너뛰기




Volumn 171, Issue 2, 1998, Pages 395-397

Navigator assessment of breath-hold duration: Impact of supplemental oxygen and hyperventilation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; ARTIFACT REDUCTION; BREATH HOLDING; COMPUTER ASSISTED TOMOGRAPHY; DIAPHRAGM; FEMALE; HUMAN; HUMAN EXPERIMENT; HYPERVENTILATION; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OXYGEN SUPPLY; PRIORITY JOURNAL;

EID: 0031850651     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/ajr.171.2.9694460     Document Type: Article
Times cited : (41)

References (15)
  • 1
    • 0025342374 scopus 로고
    • Quantification of coronary artery calcium using ultrafast computed tomography
    • Agatston AS, Janowitz WR, Hildner FJ, et al. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 1990;15:827-832
    • (1990) J Am Coll Cardiol , vol.15 , pp. 827-832
    • Agatston, A.S.1    Janowitz, W.R.2    Hildner, F.J.3
  • 2
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single breath-hold technique, continuous transport and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single breath-hold technique, continuous transport and continuous scanner rotation. Radiology 1990;176:181-183
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 4
    • 0028915260 scopus 로고
    • Respiratory blur in 3D coronary MR imaging
    • Wang Y, Grist TM, Korosec FR, et al. Respiratory blur in 3D coronary MR imaging. Magn Reson Med 1995;33:541-548
    • (1995) Magn Reson Med , vol.33 , pp. 541-548
    • Wang, Y.1    Grist, T.M.2    Korosec, F.R.3
  • 5
    • 0031567855 scopus 로고    scopus 로고
    • Measurement of coronary blood flow velocity during handgrip exercise using breath-hold velocity encoded cine magnetic resonance imaging
    • Globits S, Sakuma H, Shimakawa A, et al. Measurement of coronary blood flow velocity during handgrip exercise using breath-hold velocity encoded cine magnetic resonance imaging. Am J Cardiol 1997;79:234-237
    • (1997) Am J Cardiol , vol.79 , pp. 234-237
    • Globits, S.1    Sakuma, H.2    Shimakawa, A.3
  • 6
    • 0023202862 scopus 로고
    • Oxygen-assisted breath-holding in computed tomography
    • Sadatoh N, Hatabu H, Takahashi M, et al. Oxygen-assisted breath-holding in computed tomography. J Comput Assist Tomogr 1987;11:742-744
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 742-744
    • Sadatoh, N.1    Hatabu, H.2    Takahashi, M.3
  • 8
    • 0031401343 scopus 로고
    • Breath-holding in healthy and pulmonary compromised populations: Effects of hyperventilation and oxygen inspiration
    • Marks B, Mitchell DG, Simelaro JP. Breath-holding in healthy and pulmonary compromised populations: effects of hyperventilation and oxygen inspiration. J Magn Reson Imaging 1977;7:595-597
    • (1977) J Magn Reson Imaging , vol.7 , pp. 595-597
    • Marks, B.1    Mitchell, D.G.2    Simelaro, J.P.3
  • 9
    • 0028915260 scopus 로고
    • Respiratory blur in 3D coronary MR imaging
    • Wang Y, Grist TM, Korosec FR, et al. Respiratory blur in 3D coronary MR imaging. Magn Reson Med 1995;33:541-548
    • (1995) Magn Reson Med , vol.33 , pp. 541-548
    • Wang, Y.1    Grist, T.M.2    Korosec, F.R.3
  • 10
    • 0000905614 scopus 로고
    • Breath holding after breathing of oxygen
    • Klocke FJ, Rahn H. Breath holding after breathing of oxygen. J Appl Physiol 1959;14:689-693
    • (1959) J Appl Physiol , vol.14 , pp. 689-693
    • Klocke, F.J.1    Rahn, H.2
  • 11
    • 0004309459 scopus 로고
    • Voluntary breathholding. II. The relation of the maximum time of breathholding to the oxygen tension of the inspired air
    • Engel GL, Ferns EB, Webb JP, Stevens CD. Voluntary breathholding. II. The relation of the maximum time of breathholding to the oxygen tension of the inspired air. J Clin Invest 1946;25:729-733
    • (1946) J Clin Invest , vol.25 , pp. 729-733
    • Engel, G.L.1    Ferns, E.B.2    Webb, J.P.3    Stevens, C.D.4
  • 12
    • 0030977431 scopus 로고    scopus 로고
    • Prospective navigator correction of image position for coronary MR angiography
    • Danias PG, McConnell MV, Khasgiwala VC. et al. Prospective navigator correction of image position for coronary MR angiography. Radiology 1997;203:733-736
    • (1997) Radiology , vol.203 , pp. 733-736
    • Danias, P.G.1    McConnell, M.V.2    Khasgiwala, V.C.3
  • 13
    • 0031412991 scopus 로고    scopus 로고
    • MR navigator-echo monitoring of temporal changes in diaphragm position: Implications for MR coronary angiography
    • Taylor AM, Jhooti P, Wiessmann F, et al. MR navigator-echo monitoring of temporal changes in diaphragm position: implications for MR coronary angiography. J Magn Reson Imaging 1997;7:629-636
    • (1997) J Magn Reson Imaging , vol.7 , pp. 629-636
    • Taylor, A.M.1    Jhooti, P.2    Wiessmann, F.3
  • 14
    • 0023148303 scopus 로고
    • Hyperoxic-induced hypercapnia in stable chronic obstructive pulmonary disease
    • Sassoon CSH, Hassell KT, Mahutte CK. Hyperoxic-induced hypercapnia in stable chronic obstructive pulmonary disease. Am Rev Respir Dis 1987;135:907-911
    • (1987) Am Rev Respir Dis , vol.135 , pp. 907-911
    • Sassoon, C.S.H.1    Hassell, K.T.2    Mahutte, C.K.3
  • 15
    • 0025949110 scopus 로고
    • Oxygen-induced hypercarbia in obstructive pulmonary disease
    • Dunn WF, Nelson SB, Hubmayr RD. Oxygen-induced hypercarbia in obstructive pulmonary disease. Am Rev Respir Dis 1991;144:526-530
    • (1991) Am Rev Respir Dis , vol.144 , pp. 526-530
    • Dunn, W.F.1    Nelson, S.B.2    Hubmayr, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.