-
1
-
-
0023866355
-
Detection of coronary artery bypass graft patency as assessed by magnetic resonance imaging
-
Jenkins JPR, Love HG, Foster CJ, Isherwood I, Rowlands DJ. Detection of coronary artery bypass graft patency as assessed by magnetic resonance imaging. Br J Radiol. 1988;61:2-4.
-
(1988)
Br J Radiol.
, vol.61
, pp. 2-4
-
-
Jenkins, J.P.R.1
Love, H.G.2
Foster, C.J.3
Isherwood, I.4
Rowlands, D.J.5
-
2
-
-
0024535628
-
A study of coronary artery bypass graft patency using MR imaging
-
Frija G, Schouman-Claeys E, Lacombe P, Bismuth V, Ollivier J-P. A study of coronary artery bypass graft patency using MR imaging. J Comput Assist Tomogr. 1989;13:226-232.
-
(1989)
J Comput Assist Tomogr.
, vol.13
, pp. 226-232
-
-
Frija, G.1
Schouman-Claeys, E.2
Lacombe, P.3
Bismuth, V.4
Ollivier, J.-P.5
-
3
-
-
0023252971
-
Coronary artery bypass graft patency: Noninvasive evaluation with MR imaging
-
White RD, Caputo GR, Mark AS, Modin GW, Higgins CB. Coronary artery bypass graft patency: noninvasive evaluation with MR imaging. Radiology. 1987;164:681-686.
-
(1987)
Radiology
, vol.164
, pp. 681-686
-
-
White, R.D.1
Caputo, G.R.2
Mark, A.S.3
Modin, G.W.4
Higgins, C.B.5
-
5
-
-
0023883415
-
Coronary artery bypass grafts: Evaluation of patency with cine MR imaging
-
White RD, Pflugfelder PW, Lipton MJ, Higgins CB. Coronary artery bypass grafts: evaluation of patency with cine MR imaging. Am J Radiol. 1988;150:1271-1274.
-
(1988)
Am J Radiol.
, vol.150
, pp. 1271-1274
-
-
White, R.D.1
Pflugfelder, P.W.2
Lipton, M.J.3
Higgins, C.B.4
-
6
-
-
0024807123
-
Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging
-
Aurigemma GP, Reichek N, Axel L, Schiebler M, Harris C, Kressel HY. Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging. Circulation. 1989;80: 1595-1602.
-
(1989)
Circulation
, vol.80
, pp. 1595-1602
-
-
Aurigemma, G.P.1
Reichek, N.2
Axel, L.3
Schiebler, M.4
Harris, C.5
Kressel, H.Y.6
-
7
-
-
0023626729
-
Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts
-
Rubinstein RI, Askenase AD, Thickman D, Feldman MS, Agarwal JB, Helfant RH. Magnetic resonance imaging to evaluate patency of aortocoronary bypass grafts. Circulation. 1987;76:786-791.
-
(1987)
Circulation
, vol.76
, pp. 786-791
-
-
Rubinstein, R.I.1
Askenase, A.D.2
Thickman, D.3
Feldman, M.S.4
Agarwal, J.B.5
Helfant, R.H.6
-
8
-
-
0023199386
-
Magnetic resonance velocity mapping: Clinical application of a new technique
-
Underwood SR, Firmin DN, Klipstein RH, Rees RSO, Longmore DB. Magnetic resonance velocity mapping: clinical application of a new technique. Br Heart J. 1987;57:404-412.
-
(1987)
Br Heart J.
, vol.57
, pp. 404-412
-
-
Underwood, S.R.1
Firmin, D.N.2
Klipstein, R.H.3
Rees, R.S.O.4
Longmore, D.B.5
-
9
-
-
0026547051
-
Global left ventricular perfusion: Noninvasive measurement with cine MR imaging and phase velocity mapping of coronary venous outflow
-
Van Rossum AC, Visser FC, Hofman MBM, Galjee MA, Westerhof N, Valk J. Global left ventricular perfusion: noninvasive measurement with cine MR imaging and phase velocity mapping of coronary venous outflow. Radiology. 1992;182:685-691.
-
(1992)
Radiology
, vol.182
, pp. 685-691
-
-
Van Rossum, A.C.1
Visser, F.C.2
Hofman, M.B.M.3
Galjee, M.A.4
Westerhof, N.5
Valk, J.6
-
10
-
-
0025974684
-
An in vivo validation of quantitative blood flow imaging in arteries and veins using magnetic resonance phase-shift technique
-
Van Rossum AC, Sprenger M, Visser FC, Peels KH, Valk J, Roos JP. An in vivo validation of quantitative blood flow imaging in arteries and veins using magnetic resonance phase-shift technique. Eur Heart J. 1991;12:117-126.
-
(1991)
Eur Heart J.
, vol.12
, pp. 117-126
-
-
Van Rossum, A.C.1
Sprenger, M.2
Visser, F.C.3
Peels, K.H.4
Valk, J.5
Roos, J.P.6
-
11
-
-
0017327654
-
Systolic time intervals
-
Weissler AM. Systolic time intervals. N Engl J Med. 1977;296: 321-328.
-
(1977)
N Engl J Med.
, vol.296
, pp. 321-328
-
-
Weissler, A.M.1
-
13
-
-
0025115322
-
Comparison of coronary hemodynamics in patients with internal mammary artery and saphenous vein coronary artery bypass grafts: A noninvasive approach using combined two-dimensional and Doppler echocardiography
-
Fusejima K, Takahara Y, Sudo Y, Murayama H, Masuda Y, Inagaki Y. Comparison of coronary hemodynamics in patients with internal mammary artery and saphenous vein coronary artery bypass grafts: a noninvasive approach using combined two-dimensional and Doppler echocardiography. J Am Coll Cardiol. 1990;15:131-139.
-
(1990)
J Am Coll Cardiol.
, vol.15
, pp. 131-139
-
-
Fusejima, K.1
Takahara, Y.2
Sudo, Y.3
Murayama, H.4
Masuda, Y.5
Inagaki, Y.6
-
14
-
-
0026731176
-
Combined two-dimensional and Doppler echographic examination of internal mammary artery grafts from the supraclavicular fossa
-
Krijne R, Lyttwin RM, Höltgen R, Heinrich KW, Marx R, Sons H. Combined two-dimensional and Doppler echographic examination of internal mammary artery grafts from the supraclavicular fossa. Int J Cardiol. 1992;37:61-64.
-
(1992)
Int J Cardiol.
, vol.37
, pp. 61-64
-
-
Krijne, R.1
Lyttwin, R.M.2
Höltgen, R.3
Heinrich, K.W.4
Marx, R.5
Sons, H.6
-
16
-
-
0003111985
-
The measurement of coronary blood flow, oxygen consumption and efficiency of the left ventricle in man
-
Bing RJ, Hammond MM, Handelsman JC, Powers SR, Spenger FC, Eckenhoff JE, Goodale WT, Hafkenschiel JH, Kety SS. The measurement of coronary blood flow, oxygen consumption and efficiency of the left ventricle in man. Am Heart J. 1949;38:1-24.
-
(1949)
Am Heart J.
, vol.38
, pp. 1-24
-
-
Bing, R.J.1
Hammond, M.M.2
Handelsman, J.C.3
Powers, S.R.4
Spenger, F.C.5
Eckenhoff, J.E.6
Goodale, W.T.7
Hafkenschiel, J.H.8
Kety, S.S.9
-
17
-
-
0011838048
-
Left ventricular oxygen consumption blood flow and performance in mitral stenosis
-
Frank MJ, Levinson GE, Hellens HL. Left ventricular oxygen consumption blood flow and performance in mitral stenosis. Circulation. 1965;31:824-833.
-
(1965)
Circulation
, vol.31
, pp. 824-833
-
-
Frank, M.J.1
Levinson, G.E.2
Hellens, H.L.3
-
18
-
-
0019952894
-
Blood velocity, flow and dimensions of aortocoronary venous bypass grafts in the postoperative state
-
Simon R, Amende I, Oelert H, Hetzer R, Borst HG, Lichtlen PR. Blood velocity, flow and dimensions of aortocoronary venous bypass grafts in the postoperative state. Circulation. 1982;66(suppl I):I-34-I-39.
-
(1982)
Circulation
, vol.66
, Issue.1 SUPPL.
-
-
Simon, R.1
Amende, I.2
Oelert, H.3
Hetzer, R.4
Borst, H.G.5
Lichtlen, P.R.6
-
19
-
-
0028235971
-
Relation between myocardial blood flow and the severity of coronary artery stenosis
-
Uren NG, Melin JA, De Bruyne B, Wijns W, Baudhuin T, Camici P. Relation between myocardial blood flow and the severity of coronary artery stenosis. N Engl J Med. 1994;330:1782-1788.
-
(1994)
N Engl J Med.
, vol.330
, pp. 1782-1788
-
-
Uren, N.G.1
Melin, J.A.2
De Bruyne, B.3
Wijns, W.4
Baudhuin, T.5
Camici, P.6
-
20
-
-
0027403101
-
A preliminary report comparing magnetic resonance coronary angiography with conventional angiography
-
Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Eng J Med. 1993;328:828-832.
-
(1993)
N Eng J Med.
, vol.328
, pp. 828-832
-
-
Manning, W.J.1
Li, W.2
Edelman, R.R.3
-
21
-
-
0028795906
-
MRI of coronary arteries: 2 D breath-hold versus 3 D respiratory gated acquisition
-
Hofman MBM, Paschal CB, Li D, Haacke M, Van Rossum AC, Sprenger M. MRI of coronary arteries: 2 D breath-hold versus 3 D respiratory gated acquisition. J Comput Assist Tomogr. 1995;19: 56-62.
-
(1995)
J Comput Assist Tomogr.
, vol.19
, pp. 56-62
-
-
Hofman, M.B.M.1
Paschal, C.B.2
Li, D.3
Haacke, M.4
Van Rossum, A.C.5
Sprenger, M.6
-
22
-
-
0027373560
-
Magnetic resonance imaging of coronary arteries: Technique and preliminary results
-
Pennell DJ, Keegan J, Firmin DN, Gatehouse PD, Underwood SR, Longmore DB. Magnetic resonance imaging of coronary arteries: technique and preliminary results. Br Heart J. 1993;70:315-326.
-
(1993)
Br Heart J.
, vol.70
, pp. 315-326
-
-
Pennell, D.J.1
Keegan, J.2
Firmin, D.N.3
Gatehouse, P.D.4
Underwood, S.R.5
Longmore, D.B.6
|