메뉴 건너뛰기




Volumn 3, Issue 5, 2006, Pages 617-634

Physiological monitoring and control in hemodialysis: State of the art and outlook

Author keywords

Automation; Bioimpedance; Dialysis; Expert systems; Feedback control; Fluid status; Hypotension; Monitoring; Optical sensors; Ultrasound sensors; Uremic toxins

Indexed keywords

CITRATE CALCIUM; ERYTHROPOIETIN; HEPARIN;

EID: 33750471588     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/17434440.3.5.617     Document Type: Review
Times cited : (9)

References (112)
  • 2
    • 24044484898 scopus 로고    scopus 로고
    • Hemodialysis machines and monitors, chap. 14
    • In: Hörl WH, Koch K-M, Lindsay RM, Ronco C, Winchester JF (Eds). Kluwer Academic Publishers, Dordrecht/Boston/London
    • Polaschegg H-D, Levin NW. Hemodialysis machines and monitors, chap. 14. In: Replacement of Renal Function by Dialysis, 5th Edition. Hörl WH, Koch K-M, Lindsay RM, Ronco C, Winchester JF (Eds). Kluwer Academic Publishers, Dordrecht/Boston/London, 325-449 (2004).
    • (2004) Replacement of Renal Function By Dialysis, 5th Edition , pp. 325-449
    • Polaschegg, H.-D.1    Levin, N.W.2
  • 3
    • 84982719246 scopus 로고
    • The extracorporeal circuit
    • Polaschegg H-D. The extracorporeal circuit. Semin. Dial. 8, 299-304 (1995).
    • (1995) Semin. Dial. , vol.8 , pp. 299-304
    • Polaschegg, H.-D.1
  • 4
    • 0033518231 scopus 로고    scopus 로고
    • Comparison of mortality in all patients on dialysis, patients on dialysis awaiting transplantation, and recipients of a first cadaveric transplant
    • Wolfe RA, Ashby VB, Milford EL et al. Comparison of mortality in all patients on dialysis, patients on dialysis awaiting transplantation, and recipients of a first cadaveric transplant. N. Engl. J. Med. 341, 1725-1730 (1999).
    • (1999) N. Engl. J. Med. , vol.341 , pp. 1725-1730
    • Wolfe, R.A.1    Ashby, V.B.2    Milford, E.L.3
  • 7
    • 33750481327 scopus 로고    scopus 로고
    • Technologic aspects of hemodialysis and peritoneal dialysis, chap. 3
    • In: Nissenson AR, Fine RN (Eds). The McGraw Hill Companies, Inc
    • Schneditz D. Technologic aspects of hemodialysis and peritoneal dialysis, chap. 3. In: Clinical Dialysis, 4th Edition. Nissenson AR, Fine RN (Eds). The McGraw Hill Companies, Inc., 47-85 (2005).
    • (2005) Clinical Dialysis, 4th Edition , pp. 47-85
    • Schneditz, D.1
  • 8
    • 33750442647 scopus 로고    scopus 로고
    • Online monitoring and feedback-control, chap. 20
    • In: Hörl WH, Koch K-M, Lindsay RM, Ronco C, Winchester JF (Eds). Kluwer Academic Publishers, Dordrecht/Boston/London
    • Lindsay RM, Schneditz D. Online monitoring and feedback-control, chap. 20. In: Replacement of Renal Function by Dialysis, 5th Edition. Hörl WH, Koch K-M, Lindsay RM, Ronco C, Winchester JF (Eds). Kluwer Academic Publishers, Dordrecht/Boston/London, 555-584 (2004).
    • (2004) Replacement of Renal Function By Dialysis, 5th Edition , pp. 555-584
    • Lindsay, R.M.1    Schneditz, D.2
  • 11
    • 0032809457 scopus 로고    scopus 로고
    • Optical measurement of hematocrit and other biological constituents in renal therapy
    • Steuer RR, Bell DA, Barrett LL. Optical measurement of hematocrit and other biological constituents in renal therapy. Adv. Ren. Replace. Ther. 6, 217-224 (1999).
    • (1999) Adv. Ren. Replace. Ther. , vol.6 , pp. 217-224
    • Steuer, R.R.1    Bell, D.A.2    Barrett, L.L.3
  • 12
    • 0029048487 scopus 로고
    • Theory and validation of access flow measurement by dilution technique during hemodialysis
    • Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int. 48, 244-250 (1995).
    • (1995) Kidney Int. , vol.48 , pp. 244-250
    • Krivitski, N.M.1
  • 13
    • 0031939914 scopus 로고    scopus 로고
    • Accuracy of dilution techniques for access flow measurement during hemodialysis
    • Krivitski NM, MacGibbon D, Gleed RD, Dobson A. Accuracy of dilution techniques for access flow measurement during hemodialysis. Am. J. Kidney Dis. 31, 502-508 (1998).
    • (1998) Am. J. Kidney Dis. , vol.31 , pp. 502-508
    • Krivitski, N.M.1    MacGibbon, D.2    Gleed, R.D.3    Dobson, A.4
  • 14
    • 0004996865 scopus 로고
    • Automated measurement of recirculation
    • Kraemer M, Polaschegg H-D. Automated measurement of recirculation. EDTNA-ERCA. J. XIX, 8-15 (1993).
    • (1993) EDTNA-ERCA. J. , vol.19 , pp. 8-15
    • Kraemer, M.1    Polaschegg, H.-D.2
  • 15
    • 0034073031 scopus 로고    scopus 로고
    • Sensitivity and specificity of the thermodilution technique in detection of access recirculation
    • Wang E, Schneditz D, Kaufman AM, Levin NW. Sensitivity and specificity of the thermodilution technique in detection of access recirculation. Nephron 85, 134-141 (2000).
    • (2000) Nephron , vol.85 , pp. 134-141
    • Wang, E.1    Schneditz, D.2    Kaufman, A.M.3    Levin, N.W.4
  • 16
    • 1242342180 scopus 로고    scopus 로고
    • Comparison of different techniques of hemodialysis vascular access flow evaluation
    • Lopot F, Nejedly B, Sulkova S, Blaha J. Comparison of different techniques of hemodialysis vascular access flow evaluation. Int. J. Artif. Organs 26, 1056-1063 (2003).
    • (2003) Int. J. Artif. Organs , vol.26 , pp. 1056-1063
    • Lopot, F.1    Nejedly, B.2    Sulkova, S.3    Blaha, J.4
  • 17
    • 0032919646 scopus 로고    scopus 로고
    • Validation of haemodialysis recirculation and access blood flow measured by thermodilution
    • Schneditz D, Wang E, Levin NW. Validation of haemodialysis recirculation and access blood flow measured by thermodilution. Nephrol. Dial. Transplant. 14, 376-383 (1999).
    • (1999) Nephrol. Dial. Transplant. , vol.14 , pp. 376-383
    • Schneditz, D.1    Wang, E.2    Levin, N.W.3
  • 18
    • 33750493388 scopus 로고    scopus 로고
    • III. NKF-DOQI Clinical Practice Guidelines for Vascular Access: Update 2000
    • NY, USA
    • III. NKF-DOQI Clinical Practice Guidelines for Vascular Access: Update 2000. NY, USA (2004).
    • (2004)
  • 21
    • 0031463650 scopus 로고    scopus 로고
    • Predictive measures of vascular access thrombosis: A prospective study
    • May RE, Himmelfarb J, Yenicesu M et al. Predictive measures of vascular access thrombosis: a prospective study. Kidney Int. 52, 1656-1662 (1997).
    • (1997) Kidney Int. , vol.52 , pp. 1656-1662
    • May, R.E.1    Himmelfarb, J.2    Yenicesu, M.3
  • 22
    • 0029029947 scopus 로고
    • High-output cardiac failure due to excessive shunting in a hemodialysis access fistula: An easily overlooked diagnosis
    • Engelberts I, Tordoir JH, Boon ES, Schreij G. High-output cardiac failure due to excessive shunting in a hemodialysis access fistula: an easily overlooked diagnosis. Am. J. Nephrol. 15, 323-326 (1995).
    • (1995) Am. J. Nephrol. , vol.15 , pp. 323-326
    • Engelberts, I.1    Tordoir, J.H.2    Boon, E.S.3    Schreij, G.4
  • 24
    • 0032842362 scopus 로고    scopus 로고
    • Determination of access blood flow from ionic dialysance: Theory and validation
    • Mercadal L, Hamani A, Béné B, Petitclerc T. Determination of access blood flow from ionic dialysance: theory and validation. Kidney Int. 56, 1560-1565 (1999).
    • (1999) Kidney Int. , vol.56 , pp. 1560-1565
    • Mercadal, L.1    Hamani, A.2    Béné, B.3    Petitclerc, T.4
  • 25
    • 0029897982 scopus 로고    scopus 로고
    • A device and a method for rapid and accurate measurement of access recirculation during hemodialysis
    • Lindsay RM, Burbank J, Brugger J et al. A device and a method for rapid and accurate measurement of access recirculation during hemodialysis. Kidney Int. 49, 1152-1160 (1996).
    • (1996) Kidney Int. , vol.49 , pp. 1152-1160
    • Lindsay, R.M.1    Burbank, J.2    Brugger, J.3
  • 26
    • 0036119454 scopus 로고    scopus 로고
    • Extracorporeal pressure monitoring and the detection of vascular access stenosis
    • Kleinekofort W, Kraemer M, Rode C, Wizemann V. Extracorporeal pressure monitoring and the detection of vascular access stenosis. Int. J. Artif. Organs 25, 45-50 (2002).
    • (2002) Int. J. Artif. Organs , vol.25 , pp. 45-50
    • Kleinekofort, W.1    Kraemer, M.2    Rode, C.3    Wizemann, V.4
  • 28
    • 0032410220 scopus 로고    scopus 로고
    • Dynamic pressure measurement for detection of blood access stenosis
    • Polaschegg H-D, Techert F, Wizemann V. Dynamic pressure measurement for detection of blood access stenosis. EDTNA-ERCA J. 24(4), 39-44 (1998).
    • (1998) EDTNA-ERCA J. , vol.24 , Issue.4 , pp. 39-44
    • Polaschegg, H.-D.1    Techert, F.2    Wizemann, V.3
  • 30
    • 29244439015 scopus 로고    scopus 로고
    • Access monitoring is worthwile and valuable
    • Besarab A. Access monitoring is worthwile and valuable. Blood Purif. 24, 77-89 (2006).
    • (2006) Blood Purif. , vol.24 , pp. 77-89
    • Besarab, A.1
  • 31
    • 23644447011 scopus 로고    scopus 로고
    • Hemodialysis adequacy: Basic essentials and practical points for the nephrologist in training
    • Depner TA. Hemodialysis adequacy: basic essentials and practical points for the nephrologist in training. Hemodial. Int. 9, 241-254 (2005).
    • (2005) Hemodial. Int. , vol.9 , pp. 241-254
    • Depner, T.A.1
  • 32
    • 29244459465 scopus 로고    scopus 로고
    • Association of achieved dialysis dose with mortality in the hemodialysis study: An example of "dose-targeting bias"
    • Greene T, Depner TA, Daugirdas JT et al. Association of achieved dialysis dose with mortality in the hemodialysis study: an example of "dose-targeting bias". J. Am. Soc. Nephrol. 16, 3371-3380 (2005).
    • (2005) J. Am. Soc. Nephrol. , vol.16 , pp. 3371-3380
    • Greene, T.1    Depner, T.A.2    Daugirdas, J.T.3
  • 33
    • 0037406406 scopus 로고    scopus 로고
    • Review on uremic toxins: Classification, concentration, and interindividual variability
    • Vanholder R, De Smet R, Glorieux G et al. Review on uremic toxins: classification, concentration, and interindividual variability. Kidney Int. 63(5), 1934-1943 (2003).
    • (2003) Kidney Int. , vol.63 , Issue.5 , pp. 1934-1943
    • Vanholder, R.1    De Smet, R.2    Glorieux, G.3
  • 35
    • 0035221369 scopus 로고    scopus 로고
    • Clinical practice guidelines for hemodialysis adequacy: Update 2000
    • NKF-DOQI
    • NKF-DOQI. Clinical practice guidelines for hemodialysis adequacy: update 2000. Nephrol. Dial. Transplant. 37, S7-S64 (2001).
    • (2001) Nephrol. Dial. Transplant. , vol.37
  • 36
    • 0036052220 scopus 로고    scopus 로고
    • European best practice guidelines expert group on hemodialysis, European Renal Association. Section II. Hemodialysis adequacy
    • European best practice guidelines expert group on hemodialysis, European Renal Association. Section II. Hemodialysis adequacy. Nephrol. Dial. Transplant. 17, 16-31 (2002).
    • (2002) Nephrol. Dial. Transplant. , vol.17 , pp. 16-31
  • 38
    • 0029655986 scopus 로고    scopus 로고
    • Quantifying hemodialysis
    • Depner TA. Quantifying hemodialysis. Am. J. Nephrol. 16, 17-28 (1996).
    • (1996) Am. J. Nephrol. , vol.16 , pp. 17-28
    • Depner, T.A.1
  • 39
    • 8544219678 scopus 로고    scopus 로고
    • Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement
    • Argiles; A, Ficheux A, Thomas M et al. Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement. Kidney Int. 52, 530-537 (1997).
    • (1997) Kidney Int. , vol.52 , pp. 530-537
    • Argiles, A.1    Ficheux, A.2    Thomas, M.3
  • 40
    • 0031839030 scopus 로고    scopus 로고
    • A new biosensor for continuous monitoring of the spent dialysate urea level in standard hemodialysis
    • Calzavara P, Calconi G, Canini E, Paolini F. A new biosensor for continuous monitoring of the spent dialysate urea level in standard hemodialysis. Int. J. Artif. Organs 21, 147-150 (1998).
    • (1998) Int. J. Artif. Organs , vol.21 , pp. 147-150
    • Calzavara, P.1    Calconi, G.2    Canini, E.3    Paolini, F.4
  • 41
    • 0029869495 scopus 로고    scopus 로고
    • Multicenter clinical validation of an on-line monitor of dialysis adequacy
    • Depner TA, Keshaviah P, Ebben JP et al. Multicenter clinical validation of an on-line monitor of dialysis adequacy. J. Am. Soc. Nephrol. 7, 464-471 (1996).
    • (1996) J. Am. Soc. Nephrol. , vol.7 , pp. 464-471
    • Depner, T.A.1    Keshaviah, P.2    Ebben, J.P.3
  • 42
    • 0028466398 scopus 로고
    • Accuracy of an on-line urea monitor compared with urea kinetic model and direct dialysis quantification
    • Bosticardo GM, Avalle U, Giacchino F, Molino A, Alloatti S. Accuracy of an on-line urea monitor compared with urea kinetic model and direct dialysis quantification. ASAIO J. 40, M426-M430 (1994).
    • (1994) ASAIO J. , vol.40
    • Bosticardo, G.M.1    Avalle, U.2    Giacchino, F.3    Molino, A.4    Alloatti, S.5
  • 43
    • 0028884195 scopus 로고
    • Biochemical aspects and clinical perspectives of continuous urea monitoring in plasman ultrafiltrate
    • Colasanti G, Arrigo G, Santoro A et al. Biochemical aspects and clinical perspectives of continuous urea monitoring in plasman ultrafiltrate. Int. J. Artif. Organs 18, 544-547 (1995).
    • (1995) Int. J. Artif. Organs , vol.18 , pp. 544-547
    • Colasanti, G.1    Arrigo, G.2    Santoro, A.3
  • 44
    • 0027227636 scopus 로고
    • Automatic, noninvasive intradialytic clearance measurement
    • Polaschegg H-D. Automatic, noninvasive intradialytic clearance measurement. Int. J. Artif. Organs 16, 185-191 (1993).
    • (1993) Int. J. Artif. Organs , vol.16 , pp. 185-191
    • Polaschegg, H.-D.1
  • 45
    • 0027483770 scopus 로고
    • A model for non-invasive estimation of in vivo dialyzer performances and patient's conductivity during hemodialysis
    • Petitclerc T, Goux N, Reynier AL, Bene B. A model for non-invasive estimation of in vivo dialyzer performances and patient's conductivity during hemodialysis. Int. J. Artif. Organs 16, 585-591 (1993).
    • (1993) Int. J. Artif. Organs , vol.16 , pp. 585-591
    • Petitclerc, T.1    Goux, N.2    Reynier, A.L.3    Bene, B.4
  • 46
    • 0036044027 scopus 로고    scopus 로고
    • On-line clearance: Advanced methodology to monitor adequacy of dialysis at no cost
    • Gotch F. On-line clearance: advanced methodology to monitor adequacy of dialysis at no cost. Contrib. Nephrol. 137, 268-271 (2002).
    • (2002) Contrib. Nephrol. , vol.137 , pp. 268-271
    • Gotch, F.1
  • 49
    • 0038079282 scopus 로고    scopus 로고
    • Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate
    • Uhlin F, Fridolin I, Lindberg LG, Magnusson M. Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate. Am. J. Kidney Dis. 41, 1026-1036 (2003).
    • (2003) Am. J. Kidney Dis. , vol.41 , pp. 1026-1036
    • Uhlin, F.1    Fridolin, I.2    Lindberg, L.G.3    Magnusson, M.4
  • 50
    • 2942729885 scopus 로고    scopus 로고
    • Online monitoring of urea concentration in dialysate with dual-beam Fourier-transform near-infrared spectroscopy
    • Snoer Jensen P, Bak J, Ladefoged S, Andersson-Engels S, Friis-Hansen L. Online monitoring of urea concentration in dialysate with dual-beam Fourier-transform near-infrared spectroscopy. J. Biomed. Opt. 9, 553-557 (2004).
    • (2004) J. Biomed. Opt. , vol.9 , pp. 553-557
    • Snoer Jensen, P.1    Bak, J.2    Ladefoged, S.3    Andersson-Engels, S.4    Friis-Hansen, L.5
  • 51
    • 1642533457 scopus 로고    scopus 로고
    • Online measurement of urea concentration in spent dialysate during hemodialysis
    • Olesberg JT, Arnold MA, Flanigan MJ. Online measurement of urea concentration in spent dialysate during hemodialysis. Clin. Chem. 50, 175-181 (2004).
    • (2004) Clin. Chem. , vol.50 , pp. 175-181
    • Olesberg, J.T.1    Arnold, M.A.2    Flanigan, M.J.3
  • 52
    • 33646529157 scopus 로고    scopus 로고
    • Detection limit of methods to assess fluid status changes in dialysis patients
    • Kraemer M, Rode C, Wizemann V. Detection limit of methods to assess fluid status changes in dialysis patients. Kidney Int. 69, 1609-1620 (2006).
    • (2006) Kidney Int. , vol.69 , pp. 1609-1620
    • Kraemer, M.1    Rode, C.2    Wizemann, V.3
  • 53
    • 0029843821 scopus 로고    scopus 로고
    • Role of volume overload in dialysis-refractory hypertension
    • Fishbane S, Natke E, Maesaka JK. Role of volume overload in dialysis-refractory hypertension. Am. J. Kidney Dis. 28, 257-261 (1996).
    • (1996) Am. J. Kidney Dis. , vol.28 , pp. 257-261
    • Fishbane, S.1    Natke, E.2    Maesaka, J.K.3
  • 54
    • 0030011060 scopus 로고    scopus 로고
    • Impact of hypertension on cardiomyopathy, morbidity and mortality in end-stage renal disease
    • Foley RN, Parfrey PS, Harnett JD, Kent GM, Murray DC, Barre PE. Impact of hypertension on cardiomyopathy, morbidity and mortality in end-stage renal disease. Kidney Int. 49, 1379-1385 (1996).
    • (1996) Kidney Int. , vol.49 , pp. 1379-1385
    • Foley, R.N.1    Parfrey, P.S.2    Harnett, J.D.3    Kent, G.M.4    Murray, D.C.5    Barre, P.E.6
  • 55
    • 0001822935 scopus 로고    scopus 로고
    • Pathogenesis of cardiac disease in dialysis patients
    • Parfrey PS. Pathogenesis of cardiac disease in dialysis patients. Semin. Dial. 12, 62-68 (1999).
    • (1999) Semin. Dial. , vol.12 , pp. 62-68
    • Parfrey, P.S.1
  • 56
    • 0031779420 scopus 로고    scopus 로고
    • Dry weight in dialysis: The history of a concept
    • Charra B. Dry weight in dialysis: the history of a concept. Nephrol. Dial. Transplant. 13, 1882-1885 (1998).
    • (1998) Nephrol. Dial. Transplant. , vol.13 , pp. 1882-1885
    • Charra, B.1
  • 57
    • 0032936433 scopus 로고    scopus 로고
    • Assessment of dry weight in hemodialysis: An overview
    • Jaeger JQ, Mehta RL. Assessment of dry weight in hemodialysis: an overview. J. Am. Soc. Nephrol. 10, 392-403 (1999).
    • (1999) J. Am. Soc. Nephrol. , vol.10 , pp. 392-403
    • Jaeger, J.Q.1    Mehta, R.L.2
  • 59
    • 0028790558 scopus 로고
    • Dilemma of assessing volume state - The use and the limitations of a clinical score
    • Wizemann V, Schilling M. Dilemma of assessing volume state - the use and the limitations of a clinical score. Nephrol. Dial. Transplant. 10, 2114-2117 (1995).
    • (1995) Nephrol. Dial. Transplant. , vol.10 , pp. 2114-2117
    • Wizemann, V.1    Schilling, M.2
  • 60
    • 0029555935 scopus 로고
    • The inferior vena cava diameter as a marker of dry weight in chronic hemodialyzed patients
    • Ando Y, Yanagiba S, Asano Y. The inferior vena cava diameter as a marker of dry weight in chronic hemodialyzed patients. Artif. Organs 12, 1237-1242 (1995).
    • (1995) Artif. Organs , vol.12 , pp. 1237-1242
    • Ando, Y.1    Yanagiba, S.2    Asano, Y.3
  • 61
    • 0030099435 scopus 로고    scopus 로고
    • Echography of the inferior vena cava for estimating fluid removal from patients undergoing hemodialysis
    • Kusaba T, Yamaguchi K, Oda H. Echography of the inferior vena cava for estimating fluid removal from patients undergoing hemodialysis. Jpn J. Nephrol. 38, 119-123 (1996).
    • (1996) Jpn J. Nephrol. , vol.38 , pp. 119-123
    • Kusaba, T.1    Yamaguchi, K.2    Oda, H.3
  • 62
    • 0033866828 scopus 로고    scopus 로고
    • Diameter of inferior caval vein and impedance analysis for assessment of hydration status in peritoneal dialysis
    • Oe B, de Fijter CW, Geers TB, Vos PF, Donker ABJ, de Vries PM. Diameter of inferior caval vein and impedance analysis for assessment of hydration status in peritoneal dialysis. Artif. Organs 24, 575-583 (2000).
    • (2000) Artif. Organs , vol.24 , pp. 575-583
    • Oe, B.1    de Fijter, C.W.2    Geers, T.B.3    Vos, P.F.4    Donker, A.B.J.5    de Vries, P.M.6
  • 63
    • 1842503926 scopus 로고    scopus 로고
    • Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf
    • Zhu F, Kuhlmann U, Sarkar S et al. Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf. Int. J. Artif. Organs 27, 104-109 (2004).
    • (2004) Int. J. Artif. Organs , vol.27 , pp. 104-109
    • Zhu, F.1    Kuhlmann, U.2    Sarkar, S.3
  • 64
    • 0037256790 scopus 로고    scopus 로고
    • Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis
    • Zhu F, Sarkar S, Kaiwatcharachai C, Greenwood R, Ronco C, Levin NW. Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis. Blood Purif. 21, 131-136 (2003).
    • (2003) Blood Purif. , vol.21 , pp. 131-136
    • Zhu, F.1    Sarkar, S.2    Kaiwatcharachai, C.3    Greenwood, R.4    Ronco, C.5    Levin, N.W.6
  • 65
    • 0032736669 scopus 로고    scopus 로고
    • Multiple frequency bioelectrical impedance analysis: A cross-validation study of the inductor circuit and cole models
    • Ward L, Cornish BH, Paton NI, Thomas BJ. Multiple frequency bioelectrical impedance analysis: a cross-validation study of the inductor circuit and cole models. Physiol. Meas. 20, 333-347 (1999).
    • (1999) Physiol. Meas. , vol.20 , pp. 333-347
    • Ward, L.1    Cornish, B.H.2    Paton, N.I.3    Thomas, B.J.4
  • 66
    • 0032870173 scopus 로고    scopus 로고
    • Single- and multifrequency models for bioelectrical impedance analysis of body water compartments
    • Gudivaka R, Schoeller DA, Kushner RF, Bolt JG. Single- and multifrequency models for bioelectrical impedance analysis of body water compartments. J. Appl. Physiol. 87, 1087-1096 (1999).
    • (1999) J. Appl. Physiol. , vol.87 , pp. 1087-1096
    • Gudivaka, R.1    Schoeller, D.A.2    Kushner, R.F.3    Bolt, J.G.4
  • 67
    • 0027767434 scopus 로고
    • Use of bioimpedance spectroscopy to determine extracellular fluid, intracellular fluid, total body water, and fat-free mass
    • In: Ellis KJ, Eastman JD. (Eds), Plenum Press, NY, USA
    • van Loan MD, Withers PO, Matthie JR, Mayclin PL. Use of bioimpedance spectroscopy to determine extracellular fluid, intracellular fluid, total body water, and fat-free mass. In: Human Body Composition. Ellis KJ, Eastman JD. (Eds), Plenum Press, NY, USA, 67-70 (1993).
    • (1993) Human Body Composition , pp. 67-70
    • van Loan, M.D.1    Withers, P.O.2    Matthie, J.R.3    Mayclin, P.L.4
  • 68
    • 0028344740 scopus 로고
    • Estimation of total body and extracellular water using single- and multiple-frequency bioimpedance
    • Patel RV, Matthie JR, Withers PO, Peterson EL, Zarowitz BJ. Estimation of total body and extracellular water using single- and multiple-frequency bioimpedance. Ann. Pharmacother. 28, 565-569 (1994).
    • (1994) Ann. Pharmacother. , vol.28 , pp. 565-569
    • Patel, R.V.1    Matthie, J.R.2    Withers, P.O.3    Peterson, E.L.4    Zarowitz, B.J.5
  • 70
    • 0036113534 scopus 로고    scopus 로고
    • A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance
    • Chamney P, Kraemer M, Rode C, Kleinekofort W, Wizemann V. A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance. Kidney Int. 61, 2250-2258 (2002).
    • (2002) Kidney Int. , vol.61 , pp. 2250-2258
    • Chamney, P.1    Kraemer, M.2    Rode, C.3    Kleinekofort, W.4    Wizemann, V.5
  • 71
    • 0029943697 scopus 로고    scopus 로고
    • Multifrequency bioimpedance in assessment of dry weight in haemodialysis
    • Katzarski K, Charra B, Laurent G et al. Multifrequency bioimpedance in assessment of dry weight in haemodialysis. Nephrol. Dial. Transplant. 11, 20-23 (1996).
    • (1996) Nephrol. Dial. Transplant. , vol.11 , pp. 20-23
    • Katzarski, K.1    Charra, B.2    Laurent, G.3
  • 72
    • 0030012199 scopus 로고    scopus 로고
    • Assessment of excess fluid distribution in chronic hemodialysis patients using bioimpedance spectroscopy
    • Fisch BJ, Spiegel DM. Assessment of excess fluid distribution in chronic hemodialysis patients using bioimpedance spectroscopy. Kidney Int. 49, 1105-1109 (1996).
    • (1996) Kidney Int. , vol.49 , pp. 1105-1109
    • Fisch, B.J.1    Spiegel, D.M.2
  • 73
    • 33746554268 scopus 로고    scopus 로고
    • A new model for determination of fluid status and body composition from bioimpedance measurements
    • Kraemer M. A new model for determination of fluid status and body composition from bioimpedance measurements. Physiol. Meas. 27, 901-919 (2006).
    • (2006) Physiol. Meas. , vol.27 , pp. 901-919
    • Kraemer, M.1
  • 74
    • 0001685173 scopus 로고    scopus 로고
    • Assessing the nutritional status of patients with end-stage renal disease
    • Chertow GM. Assessing the nutritional status of patients with end-stage renal disease. Semin. Dial. 10, 108-114 (1997).
    • (1997) Semin. Dial. , vol.10 , pp. 108-114
    • Chertow, G.M.1
  • 75
    • 0037403524 scopus 로고    scopus 로고
    • Can bioelectrical impedance analysis identify malnutrition in preoperative nutrition assessment?
    • Barbosa-Silva MCG, Barros AJD, Post CLA, Waitzberg DL, Heymsfield SB. Can bioelectrical impedance analysis identify malnutrition in preoperative nutrition assessment? Nutrition 19(5), 422-426 (2003).
    • (2003) Nutrition , vol.19 , Issue.5 , pp. 422-426
    • Barbosa-Silva, M.C.G.1    Barros, A.J.D.2    Post, C.L.A.3    Waitzberg, D.L.4    Heymsfield, S.B.5
  • 76
    • 0030696713 scopus 로고    scopus 로고
    • The impact of malnutrtion in morbidity and mortality in stable haemodialysis patients
    • Marcen R, Teruel JL, de la Cal MA, Gamez C. The impact of malnutrtion in morbidity and mortality in stable haemodialysis patients. Nephrol. Dial. Transplant. 12, 2324-2331 (1997).
    • (1997) Nephrol. Dial. Transplant. , vol.12 , pp. 2324-2331
    • Marcen, R.1    Teruel, J.L.2    de la Cal, M.A.3    Gamez, C.4
  • 77
    • 84982758333 scopus 로고
    • Preventing and managing hypotension
    • Daugirdas JT. Preventing and managing hypotension. Semin. Dial. 7, 276-283 (1994).
    • (1994) Semin. Dial. , vol.7 , pp. 276-283
    • Daugirdas, J.T.1
  • 78
    • 0026469888 scopus 로고
    • Paradoxical withdrawal of reflex vasoconstriction as a cause of hemodialyis-induced hypotension
    • Converse RL, Jacobsen TN, Jost CH et al. Paradoxical withdrawal of reflex vasoconstriction as a cause of hemodialyis-induced hypotension. J. Clin. Invest. 90, 1657-1665 (1992).
    • (1992) J. Clin. Invest. , vol.90 , pp. 1657-1665
    • Converse, R.L.1    Jacobsen, T.N.2    Jost, C.H.3
  • 79
    • 0035097586 scopus 로고    scopus 로고
    • Prevention of haemodialysis-induced hypotension by biofeedback control of ultrafiltration and infusion
    • Schmidt R, Roeher O, Hickstein H, Korth S. Prevention of haemodialysis-induced hypotension by biofeedback control of ultrafiltration and infusion. Nephrol. Dial. Tansplant. 16, 595-603 (2001).
    • (2001) Nephrol. Dial. Tansplant. , vol.16 , pp. 595-603
    • Schmidt, R.1    Roeher, O.2    Hickstein, H.3    Korth, S.4
  • 80
    • 0000552482 scopus 로고    scopus 로고
    • Non-invasive blood volume monitoring during hemodialysis: Technical and physiological aspects
    • Schneditz D, Levin NW. Non-invasive blood volume monitoring during hemodialysis: technical and physiological aspects. Semin. Dial. 10, 166-169 (1997).
    • (1997) Semin. Dial. , vol.10 , pp. 166-169
    • Schneditz, D.1    Levin, N.W.2
  • 81
    • 0028234683 scopus 로고
    • Prevention of hypovolemia-induced hypotension during hemodialysis by means of an optical reflection method
    • de Vries JP, Donker AJM, de Vries PM. Prevention of hypovolemia-induced hypotension during hemodialysis by means of an optical reflection method. Int. J. Artif. Organs 17, 209-214 (1994).
    • (1994) Int. J. Artif. Organs , vol.17 , pp. 209-214
    • de Vries, J.P.1    Donker, A.J.M.2    de Vries, P.M.3
  • 82
    • 0023554479 scopus 로고
    • A new method of continuous haemoglobinometric measurement of blood volume during haemodialysis
    • Schallenberg U, Stiller S, Mann H. A new method of continuous haemoglobinometric measurement of blood volume during haemodialysis. Life Support Syst. 5, 293-305 (1987).
    • (1987) Life Support Syst. , vol.5 , pp. 293-305
    • Schallenberg, U.1    Stiller, S.2    Mann, H.3
  • 83
    • 0023280895 scopus 로고
    • Continuous monitoring of blood volume changes in humans
    • Hinghofer-Szalkay H, Greenleaf JE. Continuous monitoring of blood volume changes in humans. J. Appl. Physiol. 63(3), 1003-1007 (1987).
    • (1987) J. Appl. Physiol. , vol.63 , Issue.3 , pp. 1003-1007
    • Hinghofer-Szalkay, H.1    Greenleaf, J.E.2
  • 84
    • 0025092293 scopus 로고
    • A blood protein monitor for the continuous measurement of blood volume changes during hemodialysis
    • Schneditz D, Pogglitsch H, Horina J, Binswanger U. A blood protein monitor for the continuous measurement of blood volume changes during hemodialysis. Kidney Int. 38, 342-346 (1990).
    • (1990) Kidney Int. , vol.38 , pp. 342-346
    • Schneditz, D.1    Pogglitsch, H.2    Horina, J.3    Binswanger, U.4
  • 87
    • 0021355417 scopus 로고
    • Serial blood water estimations and in-line blood viscometry: The continuous measurement of blood volume during dialysis
    • Greenwood R, Aldridge C, Cattell WR. Serial blood water estimations and in-line blood viscometry: the continuous measurement of blood volume during dialysis. Clin. Sci. 66, 583 (1984).
    • (1984) Clin. Sci. , vol.66 , pp. 583
    • Greenwood, R.1    Aldridge, C.2    Cattell, W.R.3
  • 88
    • 0033043510 scopus 로고    scopus 로고
    • On-line monitoring of intravascular volume during haemodialysis by continuous refractometry
    • Kuhlmann U, Buren FV, Aziz O, Lange H. On-line monitoring of intravascular volume during haemodialysis by continuous refractometry. Int. J. Artif. Organs 22, 205-209 (1999).
    • (1999) Int. J. Artif. Organs , vol.22 , pp. 205-209
    • Kuhlmann, U.1    Buren, F.V.2    Aziz, O.3    Lange, H.4
  • 91
    • 0038691523 scopus 로고    scopus 로고
    • Characteristics of hypotension-prone hemodialysis patients: Is there a critical relative blood volume?
    • Barth C, Boer W, Garzoni D et al. Characteristics of hypotension-prone hemodialysis patients: is there a critical relative blood volume? Nephrol. Dial. Transplant. 18, 1353-1360 (2003).
    • (2003) Nephrol. Dial. Transplant. , vol.18 , pp. 1353-1360
    • Barth, C.1    Boer, W.2    Garzoni, D.3
  • 92
    • 0010112965 scopus 로고    scopus 로고
    • New strategies for reducing intradialytic symptoms
    • Kraemer M. New strategies for reducing intradialytic symptoms. Semin. Dial. 12, 389-395 (1999).
    • (1999) Semin. Dial. , vol.12 , pp. 389-395
    • Kraemer, M.1
  • 93
    • 33750479604 scopus 로고    scopus 로고
    • Less intradialytic morbid events by automatic blood volume controlled ultrafiltration (abstract)
    • Schuemann E, Wojke R, Gauly A et al. Less intradialytic morbid events by automatic blood volume controlled ultrafiltration (abstract). Int. J. Artif. Organs 26, 652 (2003).
    • (2003) Int. J. Artif. Organs , vol.26 , pp. 652
    • Schuemann, E.1    Wojke, R.2    Gauly, A.3
  • 94
    • 0035145183 scopus 로고    scopus 로고
    • Efficacy and safety of haemodialysis treatment with the hemocontrol biofeedback system: A prospective medium-term study
    • Basile C, Giordano R, Vernaglione L et al. Efficacy and safety of haemodialysis treatment with the hemocontrol biofeedback system: a prospective medium-term study. Nephrol. Dial. Transplant. 16, 328-334 (2001).
    • (2001) Nephrol. Dial. Transplant. , vol.16 , pp. 328-334
    • Basile, C.1    Giordano, R.2    Vernaglione, L.3
  • 95
    • 18744368078 scopus 로고    scopus 로고
    • Blood volume controlled hemodialysis in hypotension-prone patients: A randomized, multicenter controlled trial
    • Santoro A, Mancini E, Basile C et al. Blood volume controlled hemodialysis in hypotension-prone patients: a randomized, multicenter controlled trial. Kidney Int. 62, 1034-1045 (2002).
    • (2002) Kidney Int. , vol.62 , pp. 1034-1045
    • Santoro, A.1    Mancini, E.2    Basile, C.3
  • 96
    • 0024703722 scopus 로고
    • An analysis of thermal regulation in hemodialysis with one and three compartment models
    • Gotch FA, Keen ML, Yarian SR. An analysis of thermal regulation in hemodialysis with one and three compartment models. ASAIO Trans. 35, 622-624 (1989).
    • (1989) ASAIO Trans. , vol.35 , pp. 622-624
    • Gotch, F.A.1    Keen, M.L.2    Yarian, S.R.3
  • 97
    • 0035459796 scopus 로고    scopus 로고
    • Temperature and thermal balance in hemodialysis
    • Schneditz D. Temperature and thermal balance in hemodialysis. Semin. Dial. 14, 357-364 (2001).
    • (2001) Semin. Dial. , vol.14 , pp. 357-364
    • Schneditz, D.1
  • 98
    • 0345543700 scopus 로고
    • Optimization of a sensor head for blood temperature measurement during hemodialysis
    • Kraemer M, Steil H, Polaschegg HD. Optimization of a sensor head for blood temperature measurement during hemodialysis. Proc. of the IEEE 14(4), 1610-1611 (1992).
    • (1992) Proc. of the IEEE , vol.14 , Issue.4 , pp. 1610-1611
    • Kraemer, M.1    Steil, H.2    Polaschegg, H.D.3
  • 99
    • 28844439974 scopus 로고
    • Control of blood temperature and thermal energy balance during hemodialysis
    • Kraemer M, Polaschegg H-D. Control of blood temperature and thermal energy balance during hemodialysis. Proc. of the IEEE 14(4) (1992).
    • (1992) Proc. of the IEEE , vol.14 , Issue.4
    • Kraemer, M.1    Polaschegg, H.-D.2
  • 100
    • 0036326468 scopus 로고    scopus 로고
    • The effects of control of thermal balance on vascular stability in hemodialysis patients: Results of the European randomized clinical trial
    • Maggiore Q, Pizzarelli F, Santoro A et al. The effects of control of thermal balance on vascular stability in hemodialysis patients: results of the European randomized clinical trial. Am. J. Kidney Dis. 40, 280-290 (2002).
    • (2002) Am. J. Kidney Dis. , vol.40 , pp. 280-290
    • Maggiore, Q.1    Pizzarelli, F.2    Santoro, A.3
  • 101
    • 0031959646 scopus 로고    scopus 로고
    • Effects of controlled blood cooling on hemodynamic stability and urea kinetics during high-efficiency hemodialysis
    • Kaufman AM, Morris AT, Lavarias VA et al. Effects of controlled blood cooling on hemodynamic stability and urea kinetics during high-efficiency hemodialysis. J. Am. Soc. Nephrol. 9, 877-883 (1998).
    • (1998) J. Am. Soc. Nephrol. , vol.9 , pp. 877-883
    • Kaufman, A.M.1    Morris, A.T.2    Lavarias, V.A.3
  • 103
    • 0030787650 scopus 로고    scopus 로고
    • Plasma potassium in patients with terminal renal failure during and after haemodialysis: Relationship with dialytic potassium removal and total body potassium
    • Blumberg A, Roser HW, Zehnder C, Mueller-Brand J. Plasma potassium in patients with terminal renal failure during and after haemodialysis: relationship with dialytic potassium removal and total body potassium. Nephrol. Dial. Transplant. 12, 1629-1634 (1997).
    • (1997) Nephrol. Dial. Transplant. , vol.12 , pp. 1629-1634
    • Blumberg, A.1    Roser, H.W.2    Zehnder, C.3    Mueller-Brand, J.4
  • 104
    • 0032229826 scopus 로고    scopus 로고
    • Epidemiology of cardiovascular disease in chronic renal disease
    • Foley RN, Parfrey PS, Sarnak MJ. Epidemiology of cardiovascular disease in chronic renal disease. J. Am. Soc. Nephrol. 9, S16-S23 (1998).
    • (1998) J. Am. Soc. Nephrol. , vol.9
    • Foley, R.N.1    Parfrey, P.S.2    Sarnak, M.J.3
  • 105
    • 0032812832 scopus 로고    scopus 로고
    • Cardiac output and central blood volume during hemodialysis: Methodology
    • Krivitski NM, Depner TA. Cardiac output and central blood volume during hemodialysis: methodology. Adv. Ren. Replace. Ther. 6, 225-232 (1999).
    • (1999) Adv. Ren. Replace. Ther. , vol.6 , pp. 225-232
    • Krivitski, N.M.1    Depner, T.A.2
  • 106
    • 0034427050 scopus 로고    scopus 로고
    • Impedance cardiography: Noninvasive measurement of cardiac stroke volume and thoracic fluid content (editorial)
    • Strobeck JE, Silver MA, Ventura H. Impedance cardiography: noninvasive measurement of cardiac stroke volume and thoracic fluid content (editorial). Congest. Heart Fail. 6, 3-6 (2000).
    • (2000) Congest. Heart Fail. , vol.6 , pp. 3-6
    • Strobeck, J.E.1    Silver, M.A.2    Ventura, H.3
  • 107
    • 0034427136 scopus 로고    scopus 로고
    • Comparative overview of cardiac output measurement methods: Has impedance cardiography come of age?
    • De Maria AN, Raisinghani A. Comparative overview of cardiac output measurement methods: has impedance cardiography come of age? Congest. Heart Fail. 6, 7-18 (2000).
    • (2000) Congest. Heart Fail. , vol.6 , pp. 7-18
    • De Maria, A.N.1    Raisinghani, A.2
  • 108
    • 0034426946 scopus 로고    scopus 로고
    • Reproducibility of impedance cardiography hemodynamic measures in clinically stable heart failure patients
    • Greenberg BH, Hermann DD, Pranulis MF, Lazio L, Cloutier D. Reproducibility of impedance cardiography hemodynamic measures in clinically stable heart failure patients. Congest. Heart Fail. 6, 19-26 (2000).
    • (2000) Congest. Heart Fail. , vol.6 , pp. 19-26
    • Greenberg, B.H.1    Hermann, D.D.2    Pranulis, M.F.3    Lazio, L.4    Cloutier, D.5
  • 109
    • 0033810113 scopus 로고    scopus 로고
    • European best practice guidelines 9-13: Anaemia management
    • Vilderrabano F, Hoerl WH, Jacobs C et al. European best practice guidelines 9-13: anaemia management. Nephrol. Dial. Tansplant. 15(Suppl. 4), 33-42 (2000).
    • (2000) Nephrol. Dial. Tansplant. , vol.15 , Issue.SUPPL. 4 , pp. 33-42
    • Vilderrabano, F.1    Hoerl, W.H.2    Jacobs, C.3
  • 110
    • 0029913675 scopus 로고    scopus 로고
    • Citrate compared to low molecular weight heparin anticoagulation in chronic hemodialysis patients
    • Janssen MJ, Deegens JK, Kapinga TH et al. Citrate compared to low molecular weight heparin anticoagulation in chronic hemodialysis patients. Kidney Int. 49, 806-813 (1996).
    • (1996) Kidney Int. , vol.49 , pp. 806-813
    • Janssen, M.J.1    Deegens, J.K.2    Kapinga, T.H.3
  • 111
    • 14844296995 scopus 로고    scopus 로고
    • Citrate for long-term hemodialysis: Prospective study of 1,009 consecutive high-flux treatments in 59 patients
    • Apsner R, Buchmayer H, Gruber D, Sunder-Plassmann G. Citrate for long-term hemodialysis: prospective study of 1,009 consecutive high-flux treatments in 59 patients. Am. J. Kidney Dis. 45, 557-564 (2005).
    • (2005) Am. J. Kidney Dis. , vol.45 , pp. 557-564
    • Apsner, R.1    Buchmayer, H.2    Gruber, D.3    Sunder-Plassmann, G.4
  • 112
    • 29144482671 scopus 로고    scopus 로고
    • Regional citrate anticoagulation during hemodialysis: A simplified procedure using Duocart biofiltration
    • Ridel C, Mercadal L, Bene B, Hamani A, Deray G, Petitclerc T. Regional citrate anticoagulation during hemodialysis: a simplified procedure using Duocart biofiltration. Blood Purif. 23, 473-480 (2005).
    • (2005) Blood Purif. , vol.23 , pp. 473-480
    • Ridel, C.1    Mercadal, L.2    Bene, B.3    Hamani, A.4    Deray, G.5    Petitclerc, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.