1
-
-
0023940197
-
Recirculation: Review, techniques for measurement and ability to predict hemoaccess stenosis before and after angioplasty
-
Nardi L, Bosch J: Recirculation: Review, techniques for measurement and ability to predict hemoaccess stenosis before and after angioplasty. Blood Purif 1988;6:85-89.
-
(1988)
Blood Purif
, vol.6
, pp. 85-89
-
-
Nardi, L.1
Bosch, J.2
-
2
-
-
0002745499
-
NKF-DOQI clinical practice guideline for vascular access. II. Monitoring and maintenance
-
NKF-DOQI Clinical Practice Guideline for Vascular Access. II. Monitoring and Maintenance. Am J Kidney Dis 1997;30(suppl 3): 162-166.
-
(1997)
Am J Kidney Dis
, vol.30
, Issue.SUPPL. 3
, pp. 162-166
-
-
-
3
-
-
0031929256
-
The role of recirculation in access monitoring
-
Sherman RA, Kapoian K: The role of recirculation in access monitoring. ASAIO J 1998;44: 40-41.
-
(1998)
ASAIO J
, vol.44
, pp. 40-41
-
-
Sherman, R.A.1
Kapoian, K.2
-
4
-
-
0032170885
-
Predictive value of access blood flow in detecting access thrombosis
-
Wang E, Schneditz D, Nepomuceno C, Lavarias T, Martin K, Morris AT, Levin NW: Predictive value of access blood flow in detecting access thrombosis. ASAIO J 1998;44:M555-M558.
-
(1998)
ASAIO J
, vol.44
-
-
Wang, E.1
Schneditz, D.2
Nepomuceno, C.3
Lavarias, T.4
Martin, K.5
Morris, A.T.6
Levin, N.W.7
-
5
-
-
0031463650
-
Predictive measures of vascular access thrombosis: A prospective study
-
May RE, Himmelfarb J, Yenicesu M, Knights S, Ikizler TA, Schulman G, Hernaz-Schulman M, Shyr Y, Hakim RM: Predictive measures of vascular access thrombosis: A prospective study. Kidney Int 1997;52:1656-1662.
-
(1997)
Kidney Int
, vol.52
, pp. 1656-1662
-
-
May, R.E.1
Himmelfarb, J.2
Yenicesu, M.3
Knights, S.4
Ikizler, T.A.5
Schulman, G.6
Hernaz-Schulman, M.7
Shyr, Y.8
Hakim, R.M.9
-
6
-
-
0027364459
-
The measurement of dialysis access recirculation
-
Sherman RA: The measurement of dialysis access recirculation. Am J Kidney Dis 1993;22: 616-621.
-
(1993)
Am J Kidney Dis
, vol.22
, pp. 616-621
-
-
Sherman, R.A.1
-
7
-
-
0030030593
-
Peripheral venous blood is not the appropriate specimen to determine the amount of recirculation during hemodialysis
-
Van Stone JC: Peripheral venous blood is not the appropriate specimen to determine the amount of recirculation during hemodialysis. ASAIO J 1996;42:41-45.
-
(1996)
ASAIO J
, vol.42
, pp. 41-45
-
-
Van Stone, J.C.1
-
8
-
-
0028359999
-
Recirculation reassessed: The impact of blood flow rate and the low-flow method reevaluated
-
Sherman RA, Materal JJ, Novik L, Cody RP: Recirculation reassessed: The impact of blood flow rate and the low-flow method reevaluated. Am J Kidney Dis 1994;23:846-848.
-
(1994)
Am J Kidney Dis
, vol.23
, pp. 846-848
-
-
Sherman, R.A.1
Materal, J.J.2
Novik, L.3
Cody, R.P.4
-
9
-
-
0037562257
-
Hemodialysis access recirculation measurement by blood temperature monitoring: A new technique
-
Kaufman AM, Kraemer M, Godmere R, Morris AT, Amerling R, Polaschegg HD, Levin NW: Hemodialysis access recirculation measurement by blood temperature monitoring: A new technique (abstract). J Am Soc Nephrol 1991;2:332.
-
(1991)
J Am Soc Nephrol
, vol.2
, pp. 332
-
-
Kaufman, A.M.1
Kraemer, M.2
Godmere, R.3
Morris, A.T.4
Amerling, R.5
Polaschegg, H.D.6
Levin, N.W.7
-
10
-
-
0026592005
-
Non-invasive determination of recirculation in the patient on dialysis
-
Hester RL, Curry E, Bower J: Non-invasive determination of recirculation in the patient on dialysis. ASAIO J 1992;38:M190-M193.
-
(1992)
ASAIO J
, vol.38
-
-
Hester, R.L.1
Curry, E.2
Bower, J.3
-
11
-
-
0028823187
-
Hemodialysis access recirculation measured by ultrasound dilution
-
Depner TA, Krivistski NM, MacGibbon D: Hemodialysis access recirculation measured by ultrasound dilution. ASAIO J 1995;41:M749-M753.
-
(1995)
ASAIO J
, vol.41
-
-
Depner, T.A.1
Krivistski, N.M.2
MacGibbon, D.3
-
12
-
-
0029897982
-
A device and a method for rapid and accurate measurement of access recirculation
-
Lindsay RM, Burbank J, Brugger J, Bradfield E, Kram R, Malek P, Blake PG: A device and a method for rapid and accurate measurement of access recirculation. Kidney Int 1996;49:1152-1160.
-
(1996)
Kidney Int
, vol.49
, pp. 1152-1160
-
-
Lindsay, R.M.1
Burbank, J.2
Brugger, J.3
Bradfield, E.4
Kram, R.5
Malek, P.6
Blake, P.G.7
-
13
-
-
0031905727
-
Direct determination of blood recirculation rate in hemodialysis by a conductivity method
-
Bosc JY, LeBlanc M, Ganred LJ, Marc JM, Foret M, Babinet F, Tetta C, Canaud B: Direct determination of blood recirculation rate in hemodialysis by a conductivity method. ASAIO J 1998;44:68-73.
-
(1998)
ASAIO J
, vol.44
, pp. 68-73
-
-
Bosc, J.Y.1
LeBlanc, M.2
Ganred, L.J.3
Marc, J.M.4
Foret, M.5
Babinet, F.6
Tetta, C.7
Canaud, B.8
-
14
-
-
0026468057
-
Cardiopulmonary recirculation during hemodialysis
-
Schneditz D, Kaufman AM, Polaschegg H, Levin NW, Daugirdas JT: Cardiopulmonary recirculation during hemodialysis. Kidney Int 1992;42:1450-1456.
-
(1992)
Kidney Int
, vol.42
, pp. 1450-1456
-
-
Schneditz, D.1
Kaufman, A.M.2
Polaschegg, H.3
Levin, N.W.4
Daugirdas, J.T.5
-
15
-
-
0031906839
-
Measurement of access flow during hemodialysis using the constant infusion approach
-
Schneditz D, Fan Z, Kaufman AM, Levin NW: Measurement of access flow during hemodialysis using the constant infusion approach. ASAIO J 1998;44:74-81.
-
(1998)
ASAIO J
, vol.44
, pp. 74-81
-
-
Schneditz, D.1
Fan, Z.2
Kaufman, A.M.3
Levin, N.W.4
-
16
-
-
0029048487
-
Theory and validation of access flow measurement by dilution technique during hemodialysis
-
Krivitski NM: Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 1995;48:244-250.
-
(1995)
Kidney Int
, vol.48
, pp. 244-250
-
-
Krivitski, N.M.1
-
17
-
-
0028793648
-
Clinical measurement of blood flow in hemodialysis access fistulae and grafts by ultrasound dilution
-
Depner TA, Krivitski NM: Clinical measurement of blood flow in hemodialysis access fistulae and grafts by ultrasound dilution. ASAIO J 1995;41:M745-M749.
-
(1995)
ASAIO J
, vol.41
-
-
Depner, T.A.1
Krivitski, N.M.2
-
18
-
-
0030933211
-
The relationship of recirculation to access blood flow
-
Besarab A, Sherman RA: The relationship of recirculation to access blood flow. Am J Kidney Dis 1997;29:223-229.
-
(1997)
Am J Kidney Dis
, vol.29
, pp. 223-229
-
-
Besarab, A.1
Sherman, R.A.2
-
19
-
-
0030250444
-
Access flow measured during hemodialysis
-
Sands J, Glidden D, Miranda C: Access flow measured during hemodialysis. ASAIO J 1996; 42:M530-M532.
-
(1996)
ASAIO J
, vol.42
-
-
Sands, J.1
Glidden, D.2
Miranda, C.3
-
20
-
-
0029846352
-
Cardiac output and urea kinetics in dialysis patients: Evidence supporting the regional blood flow model
-
George TO, Priester-Coary A, Dunea G, Schneditz D, Tarif N, Daugirdas JT: Cardiac output and urea kinetics in dialysis patients: Evidence supporting the regional blood flow model. Kidney Int 1996;50:1273-1277.
-
(1996)
Kidney Int
, vol.50
, pp. 1273-1277
-
-
George, T.O.1
Priester-Coary, A.2
Dunea, G.3
Schneditz, D.4
Tarif, N.5
Daugirdas, J.T.6
-
21
-
-
0031959646
-
Effects of controlled blood cooling on hemodynamic stability and urea kinetics during high-efficiency hemodialysis
-
Kaufman AM, Morris AT, Lavarias VA, Wang Y, Leung JF, Glabman MB, Yusuf SA, Levoci AL, Polaschegg HD, Levin NW: Effects of controlled blood cooling on hemodynamic stability and urea kinetics during high-efficiency hemodialysis. J Am Soc Nephrol 1998;9:877-883.
-
(1998)
J Am Soc Nephrol
, vol.9
, pp. 877-883
-
-
Kaufman, A.M.1
Morris, A.T.2
Lavarias, V.A.3
Wang, Y.4
Leung, J.F.5
Glabman, M.B.6
Yusuf, S.A.7
Levoci, A.L.8
Polaschegg, H.D.9
Levin, N.W.10
|