메뉴 건너뛰기




Volumn 21, Issue 1, 2003, Pages 131-136

Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis

Author keywords

Bioimpedance analysis; Body fluid; Dialysis; Dry weight; Resistivity

Indexed keywords

ADULT; BODY FLUID; BODY WEIGHT; CLINICAL ARTICLE; CONFERENCE PAPER; CONTROLLED STUDY; CUFF; DRY WEIGHT; ELECTRODE; EXTRACELLULAR FLUID; GASTROCNEMIUS MUSCLE; HEMODIALYSIS; HUMAN; HUMAN EXPERIMENT; HYDRATION; INTERMETHOD COMPARISON; MEASUREMENT; PRIORITY JOURNAL; REGIONAL BIOIMPEDANCE ANALYSIS; REPRODUCIBILITY; REST; SYSTOLIC BLOOD PRESSURE; TECHNIQUE;

EID: 0037256790     PISSN: 02535068     EISSN: None     Source Type: Journal    
DOI: 10.1159/000067855     Document Type: Conference Paper
Times cited : (40)

References (26)
  • 1
    • 0000234744 scopus 로고
    • Bio-impedance properties of tissue impedance measurements
    • Thomasset, AL: Bio-impedance properties of tissue impedance measurements. Lyon Med 1962;201:101-118.
    • (1962) Lyon Med , vol.201 , pp. 101-118
    • Thomasset, A.L.1
  • 2
    • 0014592694 scopus 로고
    • Correlation of whole-body impedance with total body water volume
    • Hoffer EC, Meador CK, Simpson DC: Correlation of whole-body impedance with total body water volume. J Appl Physiol 1969;27:531-534.
    • (1969) J Appl Physiol , vol.27 , pp. 531-534
    • Hoffer, E.C.1    Meador, C.K.2    Simpson, D.C.3
  • 5
    • 0026591568 scopus 로고
    • Bioelectrical impedance analysis: A review of principles and applications
    • Kushner RF: Bioelectrical impedance analysis: A review of principles and applications. J Am Coll Nutr 1992;11:199-209.
    • (1992) J Am Coll Nutr , vol.11 , pp. 199-209
    • Kushner, R.F.1
  • 6
    • 0030250253 scopus 로고    scopus 로고
    • Extracellular and intracellular fluid volume monitoring during dialysis by multifrequency impedancemetry
    • Jaffrin MY, Maasran M, Boudailliez B, Le Gourrier A: Extracellular and intracellular fluid volume monitoring during dialysis by multifrequency impedancemetry. ASAIO J 1996;42:M533-M538.
    • (1996) ASAIO J , vol.42
    • Jaffrin, M.Y.1    Maasran, M.2    Boudailliez, B.3    Le Gourrier, A.4
  • 7
    • 0030978220 scopus 로고    scopus 로고
    • Effect of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data
    • Scharfetter H, Monif M, Laszlo Z, Lambauer T, Hutten H, Hinghofer-Szalkay H: Effect of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data. Kidney Int 1997;51:1078-1087.
    • (1997) Kidney Int , vol.51 , pp. 1078-1087
    • Scharfetter, H.1    Monif, M.2    Laszlo, Z.3    Lambauer, T.4    Hutten, H.5    Hinghofer-Szalkay, H.6
  • 8
    • 0032170001 scopus 로고    scopus 로고
    • Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique
    • Zhu F, Schneditz D, Wang E, Martin K, Morris AT, Levin NW: Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique. ASAIO J 1998;44:M541-M545.
    • (1998) ASAIO J , vol.44
    • Zhu, F.1    Schneditz, D.2    Wang, E.3    Martin, K.4    Morris, A.T.5    Levin, N.W.6
  • 9
    • 0034219144 scopus 로고    scopus 로고
    • Use of bioelectrical impedance techniques for monitoring nutritional status in patients on maintenance dialysis
    • Dumler F, Kilates C: Use of bioelectrical impedance techniques for monitoring nutritional status in patients on maintenance dialysis. J Ren Nutr 2000;10:116-124.
    • (2000) J Ren Nutr , vol.10 , pp. 116-124
    • Dumler, F.1    Kilates, C.2
  • 10
    • 0028338537 scopus 로고
    • Segmental bioelectrical impedance analysis: Theory and application of a new technique
    • Organ LW, Bradham GB, Gore DT, Lozier SL: Segmental bioelectrical impedance analysis: Theory and application of a new technique. J Appl Physiol 1994;77:98-112.
    • (1994) J Appl Physiol , vol.77 , pp. 98-112
    • Organ, L.W.1    Bradham, G.B.2    Gore, D.T.3    Lozier, S.L.4
  • 11
    • 0031928649 scopus 로고    scopus 로고
    • Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis
    • Zhu F, Schneditz D, Wang E, Levin NW: Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis. J Appl Physiol 1998;85:497-504.
    • (1998) J Appl Physiol , vol.85 , pp. 497-504
    • Zhu, F.1    Schneditz, D.2    Wang, E.3    Levin, N.W.4
  • 12
    • 0032079339 scopus 로고    scopus 로고
    • Bioimpedance spectrometry in the determination of body water compartments: Accuracy and clinical significance
    • Thomas BJ, Ward LC, Cornish BH: Bioimpedance spectrometry in the determination of body water compartments: Accuracy and clinical significance. Appl Radiat Isot 1998;49:447-455.
    • (1998) Appl Radiat Isot , vol.49 , pp. 447-455
    • Thomas, B.J.1    Ward, L.C.2    Cornish, B.H.3
  • 14
    • 0031933854 scopus 로고    scopus 로고
    • Evaluating volume status in hemodialysis patients
    • Leypoldt JK, Cheung AK: Evaluating volume status in hemodialysis patients. Adv Ren Replace Ther 1998;5:64-74.
    • (1998) Adv Ren Replace Ther , vol.5 , pp. 64-74
    • Leypoldt, J.K.1    Cheung, A.K.2
  • 15
    • 0032936433 scopus 로고    scopus 로고
    • Assessment of dry weight in hemodialysis: An overview
    • Jaeger JQ, Mehta RL: Assessment of dry weight in hemodialysis: An overview. J Am Soc Nephrol 1999;10:392-403.
    • (1999) J Am Soc Nephrol , vol.10 , pp. 392-403
    • Jaeger, J.Q.1    Mehta, R.L.2
  • 17
    • 0031970239 scopus 로고    scopus 로고
    • Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis
    • Piccoli A: Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis. Kidney Int 1998;53:1036-1043.
    • (1998) Kidney Int , vol.53 , pp. 1036-1043
    • Piccoli, A.1
  • 18
    • 0033972819 scopus 로고    scopus 로고
    • Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis
    • Spiegel DM, Bashir K, Fisch B: Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis. Clin Nephrol 2000;53:108-114.
    • (2000) Clin Nephrol , vol.53 , pp. 108-114
    • Spiegel, D.M.1    Bashir, K.2    Fisch, B.3
  • 19
    • 0036113534 scopus 로고    scopus 로고
    • A new technique for establishing dry weight in hemodialysis patients via whole-body bioimpedance
    • Chamney PW, Kramer M, Rode C, Kleinekofort W, Wizemann V: A new technique for establishing dry weight in hemodialysis patients via whole-body bioimpedance. Kidney Int 2002;61:2250-2258.
    • (2002) Kidney Int , vol.61 , pp. 2250-2258
    • Chamney, P.W.1    Kramer, M.2    Rode, C.3    Kleinekofort, W.4    Wizemann, V.5
  • 20
    • 0036377061 scopus 로고    scopus 로고
    • Adjusting dry weight by extracellular volume and body composition in hemodialysis patients
    • Chen YC, Chen HH, Yeh JC, Chen SY: Adjusting dry weight by extracellular volume and body composition in hemodialysis patients. Nephron 2002;92:91-96.
    • (2002) Nephron , vol.92 , pp. 91-96
    • Chen, Y.C.1    Chen, H.H.2    Yeh, J.C.3    Chen, S.Y.4
  • 21
    • 0036698579 scopus 로고    scopus 로고
    • Age-related extracellular to total body water volume ratio (ECV/TBW) - Can it be used for 'dry weight' determination in dialysis patients? Application of multifrequency bioimpedance measurement
    • Lopot F, Nejedly B, Novotna H, Mackova M, Sulkova S: Age-related extracellular to total body water volume ratio (ECV/TBW) - Can it be used for 'dry weight' determination in dialysis patients? Application of multifrequency bioimpedance measurement. Int J Artif Organs 2002;25:762-769.
    • (2002) Int J Artif Organs , vol.25 , pp. 762-769
    • Lopot, F.1    Nejedly, B.2    Novotna, H.3    Mackova, M.4    Sulkova, S.5
  • 23
    • 0036172583 scopus 로고    scopus 로고
    • Comparison of segmental and global bioimpedance spectroscopy errors using generalizability theory
    • Turner AA, Lozano-Nieto A, Bouffard M: Comparison of segmental and global bioimpedance spectroscopy errors using generalizability theory. Physiol Meas 2002;23:43-57.
    • (2002) Physiol Meas , vol.23 , pp. 43-57
    • Turner, A.A.1    Lozano-Nieto, A.2    Bouffard, M.3
  • 24
    • 0035162645 scopus 로고    scopus 로고
    • Preserving central blood volume: Changes in body fluid compartments during hemodialysis
    • Shulman T, Heidenheim AP, Kianfar C, Shulman SM, Lindsay RM: Preserving central blood volume: Changes in body fluid compartments during hemodialysis. ASAIO J 2001;47:615-618.
    • (2001) ASAIO J , vol.47 , pp. 615-618
    • Shulman, T.1    Heidenheim, A.P.2    Kianfar, C.3    Shulman, S.M.4    Lindsay, R.M.5
  • 26
    • 0035173903 scopus 로고    scopus 로고
    • Interdialytic weight gain and dry weight
    • Levin NW, Zhu F, Keen M: Interdialytic weight gain and dry weight. Blood Purif 2001;19:217-221.
    • (2001) Blood Purif , vol.19 , pp. 217-221
    • Levin, N.W.1    Zhu, F.2    Keen, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.